Common Name: LOCTITE SI 5900 INSTANT GASKET MAKER KNOWN AS 5900 FLANGE SEALANT, 20166
Manufacturer: HENKEL
SDS Revision Date: 4/1/2015
SDS Format: GHS-US
   
Item Number(s): 12Z235
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1. PRODUCT AND COMPANY IDENTIFICATION 
2. HAZARDS IDENTIFICATION 
3. COMPOSITION / INFORMATION ON INGREDIENTS 
4. FIRST AID MEASURES 
5. FIRE FIGHTING MEASURES 
6. ACCIDENTAL RELEASE MEASURES 
7. HANDLING AND STORAGE 
8. EXPOSURE CONTROLS / PERSONAL PROTECTION 
9. PHYSICAL AND CHEMICAL PROPERTIES 
10. STABILITY AND REACTIVITY 
11. TOXICOLOGICAL INFORMATION 
12. ECOLOGICAL INFORMATION 
13. DISPOSAL CONSIDERATIONS 
14. TRANSPORT INFORMATION 
15. REGULATORY INFORMATION 
16. OTHER INFORMATION 



SAFETY DATA SHEET

HENKEL

REVISION NUMBER: 006.1

ISSUE DATE: 04/01/2015


1. PRODUCT AND COMPANY IDENTIFICATION 


PRODUCT NAME:
LOCTITE SI 5900 INSTANT GASKET MAKER KNOWN AS 5900 FLANGE SEALANT

IDH NUMBER: 212184

PRODUCT TYPE: SILICONE

ITEM NUMBER: 20166

RESTRICTION OF USE: NONE IDENTIFIED

REGION: UNITED STATES

COMPANY ADDRESS:
HENKEL CORPORATION
ONE HENKEL WAY
ROCKY HILL, CONNECTICUT 06067

CONTACT INFORMATION:

TELEPHONE: (860) 571-5100

MEDICAL EMERGENCY PHONE:
POISON CONTROL CENTER: 1-877-671-4608 (TOLL FREE) OR 1-303-592-1711

TRANSPORT EMERGENCY PHONE:
CHEMTREC: 1-800-424-9300 (TOLL FREE) OR 1-703-527-3887

INTERNET: WWW.HENKELNA.COM


2. HAZARDS IDENTIFICATION 


EMERGENCY OVERVIEW:

WARNING:
CAUSES SKIN IRRITATION.
MAY CAUSE AN ALLERGIC SKIN REACTION.
CAUSES SERIOUS EYE IRRITATION.

HAZARD CLASS                                           HAZARD CATEGORY

SKIN IRRITATION                                        2

EYE IRRITATION                                         2A

SKIN SENSITIZATION                                     1

PICTOGRAM(S): EXCLAMATION MARK

PRECAUTIONARY STATEMENTS:

PREVENTION:
AVOID BREATHING DUST OR FUMES. WASH THOROUGHLY AFTER HANDLING. CONTAMINATED
WORK CLOTHING SHOULD NOT BE ALLOWED OUT OF THE WORKPLACE. WEAR EYE AND FACE
PROTECTION. WEAR PROTECTIVE GLOVES.

RESPONSE:

IF ON SKIN: WASH WITH PLENTY OF SOAP AND WATER.

IF IN EYES:
RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES. REMOVE CONTACT LENSES, IF
PRESENT AND EASY TO REMOVE. CONTINUE RINSING.

IF SKIN IRRITATION OR RASH OCCURS: GET MEDICAL ATTENTION.

IF EYE IRRITATION PERSISTS:
GET MEDICAL ATTENTION. TAKE OFF CONTAMINATED CLOTHING.

STORAGE: NOT PRESCRIBED

DISPOSAL:
DISPOSE OF CONTENTS AND/OR CONTAINER ACCORDING TO FEDERAL, STATE/PROVINCIAL
AND LOCAL GOVERNMENTAL REGULATIONS.

CLASSIFICATION COMPLIES WITH OSHA HAZARD COMMUNICATION STANDARD (29 CFR
1910.1200) AND IS CONSISTENT WITH THE PROVISIONS OF THE UNITED NATIONS
GLOBALLY HARMONIZED SYSTEM OF CLASSIFICATION AND LABELING OF CHEMICALS
(GHS).

SEE SECTION 11 FOR ADDITIONAL TOXICOLOGICAL INFORMATION.


3. COMPOSITION / INFORMATION ON INGREDIENTS 


HAZARDOUS COMPONENT(S)                  CAS NUMBER         PERCENTAGE*

CALCIUM CARBONATE                         471-34-1          30 - 60

SILICONE RESIN                          PROPRIETARY         10 - 30

OXIMINO SILANE                          PROPRIETARY          1 - 5

OCTADECANOIC ACID                          57-11-4           1 - 5

CARBON BLACK                             1333-86-4           1 - 5

ALUMINUM                                 7429-90-5         0.1 - 1

BUTAN-2-ONE O,O',O",O"'-                34206-40-1         0.1 - 1
SILANETETRAYLTETRAOXIME

3-(TRIMETHOXYSILYL)PROPYLAMINE          13822-56-5         0.1 - 1

WHITE MINERAL OIL (PETROLEUM), HIGHLY    8042-47-5         0.1 - 1
REFINED

* EXACT PERCENTAGE IS A TRADE SECRET. CONCENTRATION RANGE IS PROVIDED TO
ASSIST USERS IN PROVIDING APPROPRIATE PROTECTIONS.

METHYL ETHYL KETOXIME IS FORMED DURING CURE.


4. FIRST AID MEASURES 


INHALATION:
MOVE TO FRESH AIR IN CASE OF ACCIDENTAL INHALATION OF VAPOURS OR
DECOMPOSITION PRODUCTS. IF SYMPTOMS DEVELOP AND PERSIST, GET MEDICAL
ATTENTION.

SKIN CONTACT:
WIPE OFF PASTE WITH PAPER TOWEL OR CLOTH. WASH WITH SOAP AND WATER. IF SKIN
IRRITATION PERSISTS, CALL A PHYSICIAN.

EYE CONTACT:
RINSE IMMEDIATELY WITH PLENTY OF WATER, ALSO UNDER THE EYELIDS, FOR AT
LEAST 15 MINUTES. GET MEDICAL ATTENTION.

INGESTION: DO NOT INDUCE VOMITING. GET MEDICAL ATTENTION.

SYMPTOMS: SEE SECTION 11.


5. FIRE FIGHTING MEASURES 


EXTINGUISHING MEDIA: FOAM, DRY CHEMICAL OR CARBON DIOXIDE.

SPECIAL FIREFIGHTING PROCEDURES:
WEAR SELF CONTAINED BREATHING APPARATUS. PREVENT INHALATION OF FUMES AND
GASES.

UNUSUAL FIRE OR EXPLOSION HAZARDS: NONE

HAZARDOUS COMBUSTION PRODUCTS:
OXIDES OF CARBON. OXIDES OF SILICON. FORMALDEHYDE. IRRITATING ORGANIC
VAPOURS.


6. ACCIDENTAL RELEASE MEASURES 


USE PERSONAL PROTECTION RECOMMENDED IN SECTION 8, ISOLATE THE HAZARD AREA
AND DENY ENTRY TO UNNECESSARY AND UNPROTECTED PERSONNEL.

ENVIRONMENTAL PRECAUTIONS:
DO NOT ALLOW PRODUCT TO ENTER SEWER OR WATERWAYS.

CLEAN-UP METHODS:
SCRAPE UP AS MUCH MATERIAL AS POSSIBLE. MAINTAIN GOOD VENTILATION FOR LARGE
SPILLS. PLACE SCRAP MATERIAL IN A WELL VENTILATED AREA AND ALLOW TO CURE TO
RUBBER.


7. HANDLING AND STORAGE 


HANDLING:
PREVENT CONTACT WITH EYES, SKIN AND CLOTHING. DO NOT BREATHE VAPOR AND
MIST. WASH THOROUGHLY AFTER HANDLING. DO NOT HANDLE CONTACT LENSES UNTIL
ALL SEALANT HAS BEEN REMOVED FROM HANDS. RESIDUAL SEALANT MAY TRANSFER TO
LENSES AND CAUSE EYE IRRITATION. DO NOT WEAR CONTACT LENSES.

STORAGE:
FOR SAFE STORAGE, STORE BETWEEN 0 DEG. C (32 DEG. F) AND 32 DEG. C
(89.6 DEG. F)

STORE IN A DRY AREA BELOW 90 DEG. F. KEEP CONTAINER CLOSED.

FOR INFORMATION ON PRODUCT SHELF LIFE CONTACT HENKEL CUSTOMER SERVICE AT
(800) 243-4874.


8. EXPOSURE CONTROLS / PERSONAL PROTECTION 


EMPLOYERS SHOULD COMPLETE AN ASSESSMENT OF ALL WORKPLACES TO DETERMINE THE
NEED FOR, AND SELECTION OF, PROPER EXPOSURE CONTROLS AND PROTECTIVE
EQUIPMENT FOR EACH TASK PERFORMED.

HAZARDOUS COMPONENT(S)  ACGIH TLV     OSHA PEL       AIHA WEEL  OTHER

CALCIUM CARBONATE       10 MG/M3 TWA  5 MG/M3 PEL    NONE       NONE
                        TOTAL DUST.   RESPIRABLE
                                      FRACTION.

                                      15 MG/M3 PEL
                                      TOTAL DUST.

SILICONE RESIN          NONE          NONE           NONE       NONE

OXIMINO SILANE          NONE          NONE           NONE       NONE

OCTADECANOIC ACID       10 MG/M3 TWA  NONE           NONE       NONE

CARBON BLACK            3 MG/M3 TWA   3.5 MG/M3 PEL  NONE       NONE
                        INHALABLE
                        FRACTION.

ALUMINUM                1 MG/M3 TWA   5 MG/M3 PEL    NONE       NONE
                        RESPIRABLE    (AS Al)
                        FRACTION.     RESPIRABLE
                                      DUST.

                                      15 MG/M3 PEL
                                      (AS Al)
                                      TOTAL DUST.

BUTAN-2-ONE O,O',O",    NONE          NONE           NONE       NONE
O"'-SILANETETRAYL-
TETRAOXIME

3-(TRIMETHOXYSILYL)     NONE          NONE           NONE       NONE
PROPYLAMINE

WHITE MINERAL OIL       5 MG/M3 TWA   5 MG/M3 TWA    NONE       NONE
(PETROLEUM), HIGHLY     INHALABLE     MIST
REFINED                 FRACTION.
                                      5 MG/M3 PEL
                                      MIST.

ENGINEERING CONTROLS:
PROVIDE ADEQUATE LOCAL EXHAUST VENTILATION TO MAINTAIN WORKER EXPOSURE
BELOW EXPOSURE LIMITS.

RESPIRATORY PROTECTION:
USE A DUST MASK FOR PARTICULATE CONCENTRATIONS EXCEEDING THE OCCUPATIONAL
EXPOSURE LIMIT. USE AN ORGANIC VAPOR RESPIRATOR FOR CONCENTRATIONS
EXCEEDING THE OCCUPATIONAL EXPOSURE LIMIT.

EYE/FACE PROTECTION:
SAFETY GOGGLES OR SAFETY GLASSES WITH SIDE SHIELDS. SAFETY SHOWERS AND EYE
WASH STATIONS SHOULD BE AVAILABLE.

SKIN PROTECTION:
PERMEATION RESISTANT GLOVES (BUTYL RUBBER, NITRILE RUBBER, POLYVINYL
ALCOHOL).


9. PHYSICAL AND CHEMICAL PROPERTIES 


PHYSICAL STATE: PASTE

COLOR: BLACK

ODOR: MILD

ODOR THRESHOLD: NOT AVAILABLE.

PH: NOT APPLICABLE

VAPOR PRESSURE: <5 MMHg (20 DEG. C (68 DEG. F))

BOILING POINT/RANGE: NOT APPLICABLE

MELTING POINT/ RANGE: NOT AVAILABLE.

SPECIFIC GRAVITY: 1.31 AT 20 DEG. C (68 DEG. F)

VAPOR DENSITY: HEAVIER THAN AIR.

FLASH POINT: >93 DEG. C (>199.4 DEG. F) TAGLIABUE CLOSED CUP

FLAMMABLE/EXPLOSIVE LIMITS - LOWER: NOT APPLICABLE
FLAMMABLE/EXPLOSIVE LIMITS - UPPER: NOT APPLICABLE

AUTOIGNITION TEMPERATURE: NOT AVAILABLE.

EVAPORATION RATE: NOT AVAILABLE.

SOLUBILITY IN WATER: POLYMERISES IN PRESENCE OF WATER.

PARTITION COEFFICIENT (N-OCTANOL/WATER): NOT AVAILABLE.

VOC CONTENT: 3.31%; 44.47 G/L

VISCOSITY: NOT AVAILABLE.

DECOMPOSITION TEMPERATURE: NOT AVAILABLE.


10. STABILITY AND REACTIVITY 


STABILITY: STABLE AT NORMAL CONDITIONS.

HAZARDOUS REACTIONS: NONE UNDER NORMAL PROCESSING.

HAZARDOUS DECOMPOSITION PRODUCTS:
METHYL ETHYL KETOXIME FORMED DURING CURE. OXIDES OF CARBON. OXIDES OF
SILICON. FORMALDEHYDE.

INCOMPATIBLE MATERIALS: POLYMERIZES ON CONTACT WITH WATER.

REACTIVITY: NOT AVAILABLE.

CONDITIONS TO AVOID: MOISTURE.


11. TOXICOLOGICAL INFORMATION 


RELEVANT ROUTES OF EXPOSURE: SKIN, INHALATION, EYES

POTENTIAL HEALTH EFFECTS/SYMPTOMS:

INHALATION:
INHALATION OF VAPORS FROM UNCURED SEALANT MAY CAUSE RESPIRATORY TRACT
IRRITATION. WHEN HEATED TO TEMPERATURES EXCEEDING 300 DEG. F (150 DEG. C)
IN THE PRESENCE OF AIR, SILICONES MAY FORM FORMALDEHYDE VAPORS.
FORMALDEHYDE IS A POTENTIAL CANCER HAZARD AND A KNOWN SKIN AND RESPIRATORY
SENSITIZER. VAPORS IRRITATE THE EYES, NOSE AND THROAT. SAFE HANDLING
CONDITIONS MAY BE MAINTAINED BY KEEPING FORMALDEHYDE VAPOR CONCENTRATIONS
BELOW THE OSHA PERMISSIBLE LIMIT.

SKIN CONTACT: CAUSES SKIN IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION.

EYE CONTACT: CAUSES SERIOUS EYE IRRITATION.

INGESTION:
NOT EXPECTED UNDER NORMAL CONDITIONS OF USE. MAY BE HARMFUL IF SWALLOWED.

HAZARDOUS COMPONENT(S)  LD50S AND LC50S        IMMEDIATE AND DELAYED HEALTH
                                               EFFECTS

CALCIUM CARBONATE       ORAL LD50 (RAT):       NUISANCE DUST
                        6,450 MG/KG

SILICONE RESIN          NONE                   IRRITANT

OXIMINO SILANE          NONE                   IRRITANT, ALLERGEN

OCTADECANOIC ACID       ORAL LD50 (RAT):       IRRITANT
                        4.6 G/KG

CARBON BLACK            ORAL LD50 (RAT):       RESPIRATORY, SOME EVIDENCE
                        >8,000 MG/KG           OF CARCINOGENICITY

ALUMINUM                NONE                   CENTRAL NERVOUS SYSTEM,
                                               IRRITANT, LUNG

BUTAN-2-ONE O,O',O",    NONE                   IRRITANT, ALLERGEN
O"'-SILANETETRAYL-
TETRAOXIME

3-(TRIMETHOXYSILYL)     NONE                   IRRITANT, ALLERGEN
PROPYLAMINE

WHITE MINERAL OIL       NONE                   IRRITANT
(PETROLEUM), HIGHLY
REFINED

HAZARDOUS COMPONENT(S)   NTP CARCINOGEN   IARC CARCINOGEN   OSHA CARCINOGEN
                                                            (SPECIFICALLY
                                                            REGULATED)

CALCIUM CARBONATE        NO               NO                NO

SILICONE RESIN           NO               NO                NO

OXIMINO SILANE           NO               NO                NO

OCTADECANOIC ACID        NO               NO                NO

CARBON BLACK             NO               GROUP 2B          NO

ALUMINUM                 NO               NO                NO

BUTAN-2-ONE O,O',O",     NO               NO                NO
O"'-SILANETETRAYL-
TETRAOXIME

3-(TRIMETHOXYSILYL)      NO               NO                NO
PROPYLAMINE

WHITE MINERAL OIL        NO               NO                NO
(PETROLEUM), HIGHLY
REFINED


12. ECOLOGICAL INFORMATION 


ECOLOGICAL INFORMATION: NOT AVAILABLE.


13. DISPOSAL CONSIDERATIONS 


INFORMATION PROVIDED IS FOR UNUSED PRODUCT ONLY.

RECOMMENDED METHOD OF DISPOSAL:
CURED RUBBER CAN BE INCINERATED OR LANDFILLED FOLLOWING EPA AND LOCAL
REGULATIONS.

HAZARDOUS WASTE NUMBER: NOT A RCRA HAZARDOUS WASTE.


14. TRANSPORT INFORMATION 


THE TRANSPORT INFORMATION PROVIDED IN THIS SECTION ONLY APPLIES TO THE
MATERIAL/FORMULATION ITSELF, AND IS NOT SPECIFIC TO ANY
PACKAGE/CONFIGURATION.

U.S. DEPARTMENT OF TRANSPORTATION GROUND (49 CFR):
PROPER SHIPPING NAME: NOT REGULATED
HAZARD CLASS OR DIVISION: NONE
IDENTIFICATION NUMBER: NONE
PACKING GROUP: NONE

INTERNATIONAL AIR TRANSPORTATION (ICAO/IATA):
PROPER SHIPPING NAME: NOT REGULATED
HAZARD CLASS OR DIVISION: NONE
IDENTIFICATION NUMBER: NONE
PACKING GROUP: NONE

WATER TRANSPORTATION (IMO/IMDG):
PROPER SHIPPING NAME: NOT REGULATED
HAZARD CLASS OR DIVISION: NONE
IDENTIFICATION NUMBER: NONE
PACKING GROUP: NONE
EXCEPTIONS: NONE


15. REGULATORY INFORMATION 


UNITED STATES REGULATORY INFORMATION:

TSCA 8 (B) INVENTORY STATUS:
ALL COMPONENTS ARE LISTED OR ARE EXEMPT FROM LISTING ON THE TOXIC
SUBSTANCES CONTROL ACT INVENTORY.

TSCA 12 (B) EXPORT NOTIFICATION: NONE ABOVE REPORTING DE MINIMIS

CERCLA/SARA SECTION 302 EHS: NONE ABOVE REPORTING DE MINIMIS

CERCLA/SARA SECTION 311/312: IMMEDIATE HEALTH, DELAYED HEALTH

CERCLA/SARA SECTION 313: NONE ABOVE REPORTING DE MINIMIS

CALIFORNIA PROPOSITION 65:
THIS PRODUCT CONTAINS A CHEMICAL KNOWN IN THE STATE OF CALIFORNIA TO CAUSE
CANCER. THIS PRODUCT CONTAINS A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

CANADA REGULATORY INFORMATION:

CEPA DSL/NDSL STATUS:
ALL COMPONENTS ARE LISTED ON OR ARE EXEMPT FROM LISTING ON THE CANADIAN
DOMESTIC SUBSTANCES LIST.


16. OTHER INFORMATION 


THIS SAFETY DATA SHEET CONTAINS CHANGES FROM THE PREVIOUS VERSION IN
SECTIONS: NEW SAFETY DATA SHEET FORMAT.

PREPARED BY: LOU FABRIZIO, REGULATORY AFFAIRS SPECIALIST

ISSUE DATE: 04/01/2015

DISCLAIMER:
THE DATA CONTAINED HEREIN ARE FURNISHED FOR INFORMATION ONLY AND ARE
BELIEVED TO BE RELIABLE. HOWEVER, HENKEL CORPORATION AND ITS AFFILIATES
("HENKEL") DOES NOT ASSUME RESPONSIBILITY FOR ANY RESULTS OBTAINED BY
PERSONS OVER WHOSE METHODS HENKEL HAS NO CONTROL. IT IS THE USER'S
RESPONSIBILITY TO DETERMINE THE SUITABILITY OF HENKEL'S PRODUCTS OR ANY
PRODUCTION METHODS MENTIONED HEREIN FOR A PARTICULAR PURPOSE, AND TO ADOPT
SUCH PRECAUTIONS AS MAY BE ADVISABLE FOR THE PROTECTION OF PROPERTY AND
PERSONS AGAINST ANY HAZARDS THAT MAY BE INVOLVED IN THE HANDLING AND USE OF
ANY HENKEL'S PRODUCTS. IN LIGHT OF THE FOREGOING, HENKEL SPECIFICALLY
DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARISING FROM SALE OR
USE OF HENKEL'S PRODUCTS. HENKEL FURTHER DISCLAIMS ANY LIABILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING LOST PROFITS.