Common Name: NI-MH RECHARGEABLE BATTERY
Manufacturer: BST POWER CHINA
SDS Revision Date: 4/8/2015
SDS Format: GHS-US
   
Item Number(s): 16U272, 357T69, 357T70, 357T72, 357T73, 357U08, 357U09, 357U10, 357U11
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE 
2. HAZARDS IDENTIFICATION 
3. COMPOSITION/INFORMATION ON INGREDIENTS 
4. FIRST AID MEASURES 
5. FIRE-FIGHTING MEASURES 
6. ACCIDENTAL RELEASE MEASURES 
7. HANDLING AND STORAGE 
8. EXPOSURE CONTROLS/PERSONAL PROTECTION 
9. PHYSICAL AND CHEMICAL PROPERTIES 
10. STABILITY AND REACTIVITY 
11. TOXICOLOGICAL INFORMATION 
12. ECOLOGICAL INFORMATION 
13. DISPOSAL CONSIDERATIONS 
14. TRANSPORT INFORMATION 
15. REGULATORY INFORMATION 
16. OTHER INFORMATION 



SAFETY DATA SHEET

MINISTRY OF EMPLOYMENT AND LABOR PUBLIC NOTICE NO. 2013-37

VERSION: 1

ISSUE DATE: 08-APR-2015

PRODUCT NAME: NI-MH RECHARGEABLE BATTERY

REVISION DATE: 08-APR-2015


1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE 

                   COMPANY/UNDERTAKING

PRODUCT IDENTIFIER:

PRODUCT NAME: Ni-MH RECHARGEABLE BATTERY

OTHER MEANS OF IDENTIFICATION:

SYNONYMS: NO INFORMATION AVAILABLE

RECOMMENDED USE OF THE CHEMICAL AND RESTRICTIONS ON USE:

RECOMMENDED USE: USED FOR ELECTRONIC PRODUCTS

USES ADVISED AGAINST: NO INFORMATION AVAILABLE

DETAILS OF THE SUPPLIER OF THE SAFETY DATA SHEET:

SUPPLIER: BST POWER(SHENZHEN) LIMITED

ADDRESS:
A B C, NO.37 XINLONG ROAD
DAKANG COMMUNTY, HENGGANG TOWN
LONGGANG DISTRICT, SHENZHEN

POSTAL CODE: 518115

PHONE: +86-755-84260300

FAX: +86-755-84260306

E-MAIL: QA@BSTBATTERY.COM

EMERGENCY TELEPHONE NUMBER: +86-755-84260300


2. HAZARDS IDENTIFICATION 


GHS CLASSIFICATION: NOT CLASSIFIED

LABEL ELEMENTS:

SYMBOLS/PICTOGRAMS: NONE

SIGNAL WORD: NONE

HAZARD STATEMENTS: NOT CLASSIFIED

PRECAUTIONARY STATEMENTS:

PREVENTION: NONE

RESPONSE: NONE

STORAGE: NONE

DISPOSAL: NONE

HAZARDS NOT OTHERWISE CLASSIFIED (HNOC):

BATTERIES MAY VENT, IGNITE AND PRODUCE SPARKS WHEN SUBJECTED TO HIGH
TEMPERATURE, WHEN DAMAGED OR ABUSED (E.G., MECHANICAL DAMAGE); MAY BURN
RAPIDLY WITH FLARE-BURNING EFFECT; MAY IGNITE OTHER BATTERIES IN CLOTHES
PROXIMITY.

THIS PRODUCT SHOULD NOT PRESENT A HEALTH HAZARD WHEN USED UNDER REASONABLE
CONDITIONS. IF CONTACT WITH THE INTERNAL COMPONENTS OF THE BATTERY MAY BE
IRRITATING TO SKIN, EYES AND MUCOUS MEMBRANES. FIRE WILL PRODUCE
IRRITATING, CORROSIVE AND/OR TOXIC GASES. BURNING BATTERIES MAY PRODUCE
TOXIC HYDROGEN FLUORIDE GAS. FUMES MAY CAUSE DIZZINESS OR SUFFOCATION.

IF THE BATTERY IS DISCARDED INTO THE ENVIRONMENT, THE HARMFUL CONTENTS
INSIDE MAY BE DANGEROUS.

UNKNOWN ACUTE TOXICITY: NO INFORMATION AVAILABLE


3. COMPOSITION/INFORMATION ON INGREDIENTS 


CHEMICAL NATURE: ARTICLE

CHEMICAL NAME               CAS NO       WEIGHT-%

HYDROGEN ABSORBING ALLOY                 35

NICKEL HYDROXIDE            12054-48-7   30

IRON                         7439-89-6   15

WATER                        7732-18-5   12

COBALT(II) OXIDE             1307-96-6    8


4. FIRST AID MEASURES 


DESCRIPTION OF FIRST AID MEASURES:

GENERAL ADVICE:
NO EFFECT UNDER ROUTINE HANDLING AND USE. IF EXPOSURE TO INTERNAL MATERIALS
WITHIN CELLS DUE TO DAMAGED OUTER METAL CASING, THE FOLLOWING ACTIONS ARE
RECOMMENDED.

INHALATION:
IF INHALED, REMOVE FROM EXPOSURE AND MOVE TO FRESH AIR IMMEDIATELY. RINSE
MOUTH AND NOSE WITH WATER. GET MEDICAL AID IMMEDIATELY. DO NOT USE
MOUTH-TO-MOUTH RESUSCITATION. IF BREATHING HAS CEASED APPLY ARTIFICIAL
RESPIRATION USING OXYGEN AND A SUITABLE MECHANICAL DEVICE.

SKIN CONTACT:
IN CASE OF CONTACT, IMMEDIATELY FLUSH SKIN WITH COPIOUS AMOUNTS OF WATER
FOR AT LEAST 15 MINUTES WHILE REMOVING CONTAMINATED CLOTHING AND SHOES.
WASH CLOTHING AND SHOES BEFORE REUSE. GET MEDICAL AID.

EYE CONTACT:
RINSE IMMEDIATELY WITH PLENTY OF WATER DURING AT LEAST 15-30 MINUTES,
OCCASIONALLY LIFTING THE UPPER AND LOWER EYELIDS. CHECK FOR AND REMOVE ANY
CONTACT LENSES IF EASILY POSSIBLE. DO NOT RUBBING EYES WITH HAND. GET
MEDICAL AID IMMEDIATELY.

INGESTION:
DO NOT INDUCE VOMITING. IF THE INJURED IS FULLY CONSCIOUS: WASH MOUTH OUT
WITH WATER, THEN GIVE 2-4 CUPFULS OF MILK OR WATER. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON. GET MEDICAL AID IMMEDIATELY.

MOST IMPORTANT SYMPTOMS AND EFFECTS, BOTH ACUTE AND DELAYED:
SEE SECTION 11 FOR MORE INFORMATION.

INDICATION OF ANY IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT NEEDED:
TREAT SYMPTOMATICALLY AND SUPPORTIVELY.


5. FIRE-FIGHTING MEASURES 


EXTINGUISHING MEDIA:

SUITABLE EXTINGUISHING MEDIA:
DRY SAND OR CLASS D EXTINGUISHING AGENTS. IF THE BATTERY IS BURNING, WATER
CAN ALSO BE SUBMERGED IGNITION GROUND.

UNSUITABLE EXTINGUISHING MEDIA: NO INFORMATION AVAILABLE.

SPECIFIC HAZARDS ARISING FROM THE CHEMICAL:
TOXIC VAPOR MAY RELEASE IN CASE OF FIRE. THERMAL SHOCK MAY CAUSE BATTERY
CASE TO CRACK OPEN. CONTAINERS MAY EXPLODE WHEN HEATED. FIREFIGHTING WATER
RUNOFF AND DILUTION WATER MAY BE TOXIC AND CORROSIVE AND MAY CAUSE ADVERSE
ENVIRONMENTAL IMPACTS. ON SOME BAD USING CONDITIONS (E.G., MECHANICAL
DAMAGE, EXTERNAL SHORT CIRCUIT.) AND IN CASE OF A BAD FUNCTIONING, SOME
ELECTROLYTE CAN BE REMOVED FROM THE CELL BY THE SECURITY VENT. EXPOSURE TO
THE INGREDIENTS CONTAINED WITHIN THE BATTERY PACK COULD BE HARMFUL UNDER
SOME CIRCUMSTANCES.

PROTECTIVE EQUIPMENT AND PRECAUTIONS FOR FIREFIGHTERS:
AS IN ANY FIRE, WEAR SELF-CONTAINED BREATHING APPARATUS PRESSURE-DEMAND,
MSHA/NIOSH (APPROVED OR EQUIVALENT) AND FULL PROTECTIVE GEAR.


6. ACCIDENTAL RELEASE MEASURES 


PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:

NO ACTION SHALL BE TAKEN INVOLVING ANY PERSONAL RISK OR WITHOUT SUITABLE
TRAINING. REVIEW SECTION 5 AND SECTION 7 SECTIONS BEFORE PROCEEDING WITH
CLEAN-UP. USE PROPER PERSONAL PROTECTIVE EQUIPMENT AS INDICATED IN SECTION
8. APPROPRIATE VENTILATION.

EVACUATE AND VENTILATE SPILL AREA. REMOVE ALL SOURCES OF IGNITION OR HEAT.
STOP LEAK IF SAFE TO DO SO. MOVE CONTAINERS FROM SPILL AREA. KEEP
UNNECESSARY AND UNPROTECTED PERSONNEL FROM ENTERING. REVIEW SECTION 5 AND
SECTION 7 SECTIONS BEFORE PROCEEDING WITH CLEAN-UP.

METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP:

AVOID DISPERSAL OF SPILLED MATERIAL AND RUNOFF AND CONTACT WITH SOIL, WATER
WAYS, DRAINS AND SEWERS.

REMOVE ALL SOURCES OF IGNITION OR HEAT. STOP LEAK IF SAFE TO DO SO. MOVE
CONTAINERS FROM SPILL AREA. CAREFULLY COLLECT UNDAMAGED BATTERIES IN A
CLEAN, DRY AND APPROPRIATE CONTAINER FOR REUSE OR DISPOSAL. IF ELECTROLYTE
LEAKS OR SPILLS, COLLECT ALL RELEASED MATERIAL IN AN APPROPRIATE CONTAINER
BEFORE PROPER DISPOSAL.


7. HANDLING AND STORAGE 


PRECAUTIONS FOR SAFE HANDLING
THIS PRODUCT SHOULD BE STORED, HANDLED AND USED IN ACCORDANCE WITH GOOD
INDUSTRIAL HYGIENE PRACTICES AND IN CONFORMITY WITH ANY LEGAL REGULATION.
EATING, DRINKING AND SMOKING SHOULD BE PROHIBITED IN AREAS WHERE THIS
MATERIAL IS HANDLED, STORED AND PROCESSED. WASH HANDS, FOREARMS AND FACE
THOROUGHLY AFTER HANDLING CHEMICAL PRODUCTS, BEFORE EATING, SMOKING AND
USING THE LAVATORY AND AT THE END OF THE WORKING PERIOD.

CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES:
STORE IN A COOL AND DRY AREA, BUT PREVENT CONDENSATION ON CELL OR BATTERY
TERMINALS. HIGH TEMPERATURE MAY DAMAGE THE PERFORMANCE OF THE BATTERY.
PROTECT FROM PHYSICAL DAMAGE AND SHORT CIRCUITS. TO AVOID RISK OF FIRE OR
EXPLOSION, KEEP SPARKS AND OTHER SOURCES OF IGNITION AWAY FROM THE BATTERY.
DO NOT ALLOW METAL OBJECTS TO SIMULTANEOUSLY CONTACT BOTH POSITIVE AND
NEGATIVE TERMINAL OF BATTERIES. DO NOT STACK BATTERY DIRECTLY ON ANOTHER
BATTERY. DO NOT STORE BATTERIES ON ELECTRICALLY CONDUCTIVE SURFACES.


8. EXPOSURE CONTROLS/PERSONAL PROTECTION 


CONTROL PARAMETERS:

CHEMICAL NAME     ACGIH TLV   OSHA PEL    NIOSH IDLH   DENMARK     EUROPEAN
                                                                   UNION

NICKEL HYDROXIDE  TWA:        TWA:        IDLH:        TWA:
(CAS #:           0.2 MG/M3   1 MG/M3 Ni  10 MG/M3     0.05 MG/M3
12054-48-7)       Ni          (VACATED)   Ni
                  INHALABLE   TWA:        TWA:
                  FRACTION    1 MG/M3 Ni  0.015 MG/M3
                                          EXCEPT
                                          NICKEL
                                          CARBONYL Ni

COBALT(II) OXIDE  TWA:                                 TWA:
(CAS #:           0.02 MG/M3                           0.01 MG/M3
1307-96-6)        Co

CHEMICAL NAME        LATVIA       FRANCE    FINLAND     GERMANY   ITALY

NICKEL HYDROXIDE     TWA:         TWA:      TWA:        SKIN
(CAS #: 12054-48-7)  0.05 MG/M3   1 MG/M3   0.1 MG/M3

COBALT(II) OXIDE     TWA:                   TWA:        SKIN
(CAS #: 1307-96-6)   0.5 MG/M3              0.02 MG/M3

CHEMICAL NAME        POLAND      PORTUGAL   SPAIN       SWITZERLAND  NETHER
                                                                     -LANDS
NICKEL HYDROXIDE     TWA:        TWA:        TWA:        TWA:
(CAS #: 12054-48-7)  0.25 MG/M3  0.2 MG/M3   0.2 MG/M3   0.05 MG/M3

COBALT(II) OXIDE     TWA:        TWA:        TWA:        SKIN
(CAS #: 1307-96-6)   0.02 MG/M3  0.02 MG/M3  0.02 MG/M3  TWA:
                                                         0.05 MG/M3

CHEMICAL NAME        NORWAY       UNITED       AUSTRALIA   AUSTRIA  BELGIUM
                                  KINGDOM

NICKEL HYDROXIDE     TWA:         TWA:
(CAS #: 12054-48-7)  0.05 MG/M3   0.5 MG/M3
                     STEL:
                     0.15 MG/M3

COBALT(II) OXIDE     TWA:         TWA:                     SKIN
(CAS #: 1307-96-6)   0.02 MG/M3   0.1 MG/M3
                     STEL:
                     0.06 MG/M3

APPROPRIATE ENGINEERING CONTROLS:

GENERAL ROOM VENTILATION IS SUFFICIENT DURING NORMAL USE AND HANDING. DO
NOT INSTALL THESE BATTERIES IN SEALED, UNVENTILATED AREAS. FACILITIES
STORING OR UTILIZING THIS MATERIAL SHOULD BE EQUIPPED WITH AN EYEWASH
FACILITY AND A SAFETY SHOWER.

REMOVE JEWELRY, RINGS, WATCHES AND ANY OTHER METALLIC OBJECTS WHILE WORKING
ON BATTERY. ALL TOOLS SHOULD INSULATE TO AVOID THE POSSIBILITY OF SHORTING
CONNECTIONS. DO NOT LAY TOOLS ON TOP OF THE BATTERY. THE WORK AREA SHOULD
BE EQUIPPED WITH THE CORRESPONDING SPECIES AND QUANTITY OF FIRE EQUIPMENT
AND LEAKAGE EMERGENCY EQUIPMENT.

INDIVIDUAL PROTECTION MEASURES, SUCH AS PERSONAL PROTECTIVE EQUIPMENT:

RESPIRATORY PROTECTION:
IF EXPOSURE LIMITS ARE EXCEEDED OR IRRITATION IS EXPERIENCED, NIOSH/MSHA
APPROVED RESPIRATORY PROTECTION SHOULD BE WORN. POSITIVE-PRESSURE SUPPLIED
AIR RESPIRATORS MAY BE REQUIRED FOR HIGH AIRBORNE CONTAMINANT
CONCENTRATIONS. RESPIRATORY PROTECTION MUST BE PROVIDED IN ACCORDANCE WITH
CURRENT LOCAL REGULATIONS.

HAND PROTECTION:
UNDER NORMAL CONDITION OF USE AND HANDLING NO SPECIAL PROTECTION IS
REQUIRED FOR SEALED BATTERY. IN THE EVENT OF BATTERY CASE BREAKAGE, SHOULD
BE WEAR APPROPRIATE SAFETY GLOVES.

EYE/FACE PROTECTION:
UNDER NORMAL CONDITION OF USE AND HANDLING NO SPECIAL PROTECTION IS
REQUIRED FOR SEALED BATTERY. USE APPROPRIATE SAFETY GLASSES WHEN THERE IS
THE RISK OF SPLASH.

SKIN AND BODY PROTECTION:
UNDER NORMAL CONDITION OF USE AND HANDLING NO SPECIAL PROTECTION IS
REQUIRED FOR SEALED BATTERY. IT IS RECOMMENDED TO WEAR APPROPRIATE
PROTECTIVE CLOTHING WHEN THE BATTERY CASE IS BROKEN.


9. PHYSICAL AND CHEMICAL PROPERTIES 


INFORMATION ON BASIC PHYSICAL AND CHEMICAL PROPERTIES:

APPEARANCE: SOLID

COLOR: WHITE

ODOR: ODORLESS

ODOR THRESHOLD: NOT DETERMINED

PH: NOT DETERMINED

MELTING POINT/FREEZING POINT: NOT DETERMINED

BOILING POINT/BOILING RANGE: NOT DETERMINED

FLASH POINT: NOT APPLICABLE

EVAPORATION RATE: NOT DETERMINED

FLAMMABILITY (SOLID, GAS): NOT FLAMMABLE

FLAMMABILITY LIMIT IN AIR: NOT APPLICABLE

VAPOR PRESSURE: NOT DETERMINED

VAPOR DENSITY: NOT APPLICABLE

DENSITY: NOT DETERMINED

RELATIVE DENSITY: NOT DETERMINED

BULK DENSITY: NOT DETERMINED

SPECIFIC GRAVITY: NOT DETERMINED

WATER SOLUBILITY: INSOLUBLE IN WATER

PARTITION COEFFICIENT (LOGPOW): NOT DETERMINED

AUTOIGNITION TEMPERATURE: NOT APPLICABLE

DECOMPOSITION TEMPERATURE: NOT DETERMINED

KINEMATIC VISCOSITY: NOT DETERMINED

DYNAMIC VISCOSITY: NOT DETERMINED

EXPLOSIVE PROPERTIES: NOT AN EXPLOSIVE

OXIDIZING PROPERTIES: NOT DETERMINED

OTHER INFORMATION: NO INFORMATION AVAILABLE


10. STABILITY AND REACTIVITY 


REACTIVITY:
STABLE UNDER RECOMMENDED STORAGE AND HANDLING CONDITIONS (SEE SECTION 7,
HANDLING AND STORAGE).

CHEMICAL STABILITY: STABLE UNDER NORMAL CONDITIONS

POSSIBILITY OF HAZARDOUS REACTIONS:
WHEN A BATTERY CELL IS EXPOSED TO AN EXTERNAL SHORT-CIRCUIT, CRUSHED,
MODIFICATION, HIGH TEMPERATURE, OPEN FLAMES, IT WILL BE THE CAUSE OF HEAT
GENERATION AND IGNITION.

CONDITIONS TO AVOID:
EXPOSED TO AN EXTERNAL SHORT-CIRCUIT, CRUSHED, MODIFICATION, HIGH
TEMPERATURE, OPEN FLAMES, INCOMPATIBLE MATERIALS, DIRECT SUNLIGHT AND HIGH
HUMIDITY.

INCOMPATIBLE MATERIALS:
CONDUCTIVE MATERIALS, WATER, SEAWATER, STRONG OXIDANTS, STRONG ACID, STRONG
BASES, ETC.

HAZARDOUS DECOMPOSITION PRODUCTS:
IN CASE OF A FIRE OR HIGH TEMPERATURE, METAL OXIDES AND IRRITATING/HARMFUL
FUMES/SMOKE MAY BE GENERATED.


11. TOXICOLOGICAL INFORMATION 


INFORMATION ON LIKELY ROUTES OF EXPOSURE:

INHALATION:
NO EFFECT UNDER ROUTINE HANDLING AND USE FOR SEALED BATTERY. IF BATTERY IS
BROKEN, INHALE FUME AND DUST MAY CAUSE UPPER RESPIRATORY IRRITATION AND
LUNG IRRITATION.

EYE CONTACT:
NO EFFECT UNDER ROUTINE HANDLING AND USE FOR SEALED BATTERY. EXPOSURE TO
THE ELECTROLYTE CONTAINED INSIDE THE BATTERY MAY RESULT IN IRRITATION.

SKIN CONTACT:
NO EFFECT UNDER ROUTINE HANDLING AND USE FOR SEALED BATTERY. EXPOSURE TO
THE ELECTROLYTE CONTAINED INSIDE THE BATTERY MAY RESULT IN CHEMICAL BURNS.

INGESTION:
NO EFFECT UNDER ROUTINE HANDLING AND USE FOR SEALED BATTERY. HARMFUL IF
SWALLOWED THE ELECTROLYTE CONTAINED INSIDE THE BATTERY. EXPOSURE TO THE
ELECTROLYTE CONTAINED INSIDE THE BATTERY MAY CAUSE IRRITATION TO MOUTH,
ESOPHAGUS AND GASTROINTESTINAL SYSTEM.

INFORMATION ON TOXICOLOGICAL EFFECTS:

ACUTE TOXICITY:

CHEMICAL NAME          ORAL LD50           DERMAL LD50  INHALATION LC50

NICKEL HYDROXIDE                                        1200 MG/M3 (RAT)
(CAS #: 12054-48-7)                                     4 H

IRON                   98.6 G/KG BW (RAT)
(CAS #: 7439-89-6)

SKIN CORROSION/IRRITATION:
NO EFFECT UNDER ROUTINE HANDLING AND USE FOR SEALED BATTERY. EXPOSURE TO
THE ELECTROLYTE CONTAINED INSIDE THE BATTERY MAY RESULT IN CHEMICAL BURNS.

SERIOUS EYE DAMAGE/EYE IRRITATION:
NO EFFECT UNDER ROUTINE HANDLING AND USE FOR SEALED BATTERY. EXPOSURE TO
THE ELECTROLYTE CONTAINED INSIDE THE BATTERY MAY RESULT IN IRRITATION.

SENSITIZATION: NO SENSITIZATION RESPONSES WERE OBSERVED.

GERM CELL MUTAGENICITY: NO INFORMATION AVAILABLE

CARCINOGENICITY:

CHEMICAL NAME        ACGIH  IARC      NTP    OSHA

NICKEL HYDROXIDE     A1     GROUP 1   KNOWN  X
(CAS #: 12054-48-7)

COBALT(II) OXIDE     A3     GROUP 2B         X
(CAS #: 1307-96-6)

REPRODUCTIVE TOXICITY: NO INFORMATION AVAILABLE

STOT - SINGLE EXPOSURE: NO INFORMATION AVAILABLE

STOT - REPEATED EXPOSURE: NO INFORMATION AVAILABLE

ASPIRATION HAZARD: NO INFORMATION AVAILABLE


12. ECOLOGICAL INFORMATION 


ECOTOXICITY:

CHEMICAL NAME       ALGAE/AQUATIC PLANTS EC50   FISH LC50   CRUSTACEA EC50

IRON                                                        >100 MG/L/48H
(CAS #: 7439-89-6)                                          (DAPHNIA MAGNA)

PERSISTENCE AND DEGRADABILITY: NO INFORMATION AVAILABLE

BIOACCUMULATIVE POTENTIAL: NO INFORMATION AVAILABLE

MOBILITY IN SOIL: NO INFORMATION AVAILABLE

OTHER ADVERSE EFFECTS: NO INFORMATION AVAILABLE


13. DISPOSAL CONSIDERATIONS 


WASTE TREATMENT METHODS:

DISPOSAL OF WASTES:
CHEMICAL WASTE GENERATORS MUST DETERMINE WHETHER A DISCARDED CHEMICAL IS
CLASSIFIED AS A HAZARDOUS WASTE. DISPOSAL SHOULD BE IN ACCORDANCE WITH
APPLICABLE REGIONAL, NATIONAL AND LOCAL LAWS AND REGULATIONS.

CONTAMINATED PACKAGING:
CONTAMINATED PACKAGING MATERIAL SHOULD BE TREATED EQUIVALENT TO RESIDUAL
CHEMICAL. CLEAN PACKAGING MATERIAL SHOULD BE SUBJECTED TO WASTE MANAGEMENT
SCHEMES (RECOVERY RECYCLING, REUSE) ACCORDING TO LOCAL LEGISLATION. AVOID
DISPERSAL OF SPILLED MATERIAL AND RUNOFF AND CONTACT WITH SOIL, WATERWAYS,
DRAINS AND SEWERS.

CHEMICAL NAME       CALIFORNIA HAZARDOUS WASTE STATUS

COBALT(II) OXIDE    TOXIC
1307-96-6


14. TRANSPORT INFORMATION 


DOT:

UN/ID NO.: NOT REGULATED

PROPER SHIPPING NAME: NOT REGULATED

HAZARD CLASS: NOT REGULATED

PACKING GROUP: NOT REGULATED

SPECIAL PRECAUTIONS:
BATTERIES MUST BE SEPARATED FROM EACH OTHER AND PREVENT MOVEMENT THAT COULD
LEAD TO SHORT-CIRCUITS. PRODUCTS MUST ALSO BE PACKED IN STRONG PACKAGING
THAT CAN WITHSTAND THE RIGORS NORMAL TO TRANSPORTATION.

MARINE POLLUTANT: NOT APPLICABLE


15. REGULATORY INFORMATION 


INTERNATIONAL INVENTORIES:

COMPONENT         AICS  DSL/  EINECS/  ENCS    IECSC  KECL  PICCS  TSCA
                        NDSL  ELINCS

NICKEL HYDROXIDE  X     X     X        X       X      X     X      X
12054-48-7 (30%)

IRON              X     X     X        EXPECT  X      X     X      X
7439-89-6 (15%)

WATER             X     X     X        EXPECT  X      X     X      X
7732-18-5 (12%)

COBALT(II) OXIDE  X     X     X        X       X      X     X      X
1307-96-6 (8%)

"-" NOT LISTED
"X" LISTED

US FEDERAL REGULATIONS:

SARA 313:

CHEMICAL NAME                  SARA 313 - THRESHOLD VALUES %

CADMIUM OXIDE - 1306-19-0      0.1

NICKEL HYDROXIDE - 12054-48-7  0.1

COBALT(II) OXIDE - 1307-96-6   0.1

SARA 311/312 HAZARD CATEGORIES: NO INFORMATION AVAILABLE

CWA (CLEAN WATER ACT):

CHEMICAL NAME      CWA -       CWA - TOXIC  CWA - PRIORITY  CWA -
                   REPORTABLE  POLLUTANTS   POLLUTANTS      HAZARDOUS
                   QUANTITIES                               SUBSTANCES

CADMIUM OXIDE                  X
1306-19-0

NICKEL HYDROXIDE               X                            X
12054-48-7

CERCLA:

CHEMICAL NAME     HAZARDOUS       CERCLA/SARA RQ  REPORTABLE QUANTITY (RQ)
                  SUBSTANCES RQS

CADMIUM OXIDE                     100 LB
1306-19-0

NICKEL HYDROXIDE  10 LB                           RQ 10 LB FINAL RQ
12054-48-7                                        RQ 4.54 KG FINAL RQ

US STATE REGULATIONS:

CALIFORNIA PROPOSITION 65:

CHEMICAL NAME                  CALIFORNIA PROPOSITION 65

CADMIUM OXIDE - 1306-19-0      CARCINOGEN

NICKEL HYDROXIDE - 12054-48-7  CARCINOGEN

COBALT(II) OXIDE - 1307-96-6   CARCINOGEN

U.S. STATE RIGHT-TO-KNOW REGULATIONS:

CHEMICAL NAME      NEW JERSEY   MASSACHUSETTS  PENNSYLVANIA

CADMIUM OXIDE      X            X              X
1306-19-0

NICKEL HYDROXIDE   X            X              X
12054-48-7

COBALT(II) OXIDE   X                           X
1307-96-6


16. OTHER INFORMATION 


REVISION NOTE:

ISSUE DATE: 08-APR-2015

REVISION DATE: 08-APR-2015

REVISION NOTE: NOT APPLICABLE

KEY OR LEGEND TO ABBREVIATIONS AND ACRONYMS USED IN THE SAFETY DATA SHEET:

TWA: TWA (TIME-WEIGHTED AVERAGE)

STEL: STEL (SHORT TERM EXPOSURE LIMIT)

CEILING: MAXIMUM LIMIT VALUE

TSCA: UNITED STATES TOXIC SUBSTANCES CONTROL ACT SECTION 8(B) INVENTORY

DSL/NDSL: CANADIAN DOMESTIC SUBSTANCES LIST/NON-DOMESTIC SUBSTANCES LIST

EINECS/ELINCS:
EUROPEAN INVENTORY OF EXISTING CHEMICAL SUBSTANCES/EUROPEAN LIST OF
NOTIFIED CHEMICAL SUBSTANCES

ENCS: JAPAN EXISTING AND NEW CHEMICAL SUBSTANCES

IECSC: CHINA INVENTORY OF EXISTING CHEMICAL SUBSTANCES

KECL: KOREAN EXISTING AND EVALUATED CHEMICAL SUBSTANCES

PICCS: PHILIPPINES INVENTORY OF CHEMICALS AND CHEMICAL SUBSTANCES

AICS: AUSTRALIAN INVENTORY OF CHEMICAL SUBSTANCES

DISCLAIMER:
THE INFORMATION PROVIDED IN THIS MATERIAL SAFETY DATA SHEET IS CORRECT TO
THE BEST OF OUR KNOWLEDGE, INFORMATION AND BELIEF AT THE DATE OF ITS
PUBLICATION. THE INFORMATION GIVEN IS DESIGNED ONLY AS A GUIDANCE FOR SAFE
HANDLING, USE, PROCESSING, STORAGE, TRANSPORTATION, DISPOSAL AND RELEASE
AND IS NOT TO BE CONSIDERED A WARRANTY OR QUALITY SPECIFICATION. THE
INFORMATION RELATES ONLY TO THE SPECIFIC MATERIAL DESIGNATED AND MAY NOT BE
VALID FOR SUCH MATERIAL USED IN COMBINATION WITH ANY OTHER MATERIALS OR IN
ANY PROCESS, UNLESS SPECIFIED IN THE TEXT.

CENTRE TESTING INTERNATIONAL CORPORATION
BUILD C, HONGWEI INDUSTRIAL ZONE
BAOAN 70 DISTRICT, SHENZHEN
CHINA

WWW.CTI-CERT.COM

E-MAIL: INFO@CTI-CERT.COM

HOTLINE: 400-6788-333