SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. GASCO(R*) MATERIAL SAFETY DATA SHEET CALIBRATION CHECK GAS PRODUCT NAME: CARBON DIOXIDE (1 PPM - 35%) IN NITROGEN MSDS NO: 34 VERSION: 3 DATE: MARCH, 2012
GASCO AFFILIATES, LLC 320 SCARLETT BLVD. OLDSMAR, FL 34677 TELEPHONE NUMBER: (800) 910-0051 24-HOUR EMERGENCY NUMBER: 1-800-424-9300 FAX NUMBER: (866) 755-8920 E-MAIL: INFO@GASCOGAS.COM PRODUCT NAME: CARBON DIOXIDE (1 PPM - 35%) IN NITROGEN CHEMICAL NAME: CARBON DIOXIDE IN NITROGEN COMMON NAMES/ SYNONYMS: NONE TDG (CANADA) CLASSIFICATION: 2.2 WHIMIS CLASSIFICATION: A
INGREDIENT %VOLUME PEL-OSHA TLV-ACGIH LD50 OR LC50 ROUTE/SPECIES CARBON DIOXIDE 0.0001-35 5000 PPM TWA 5000 PPM TWA N/A FORMULA: CO2 30,000 PPM STEL NITROGEN 65.0 TO SIMPLE SIMPLE N/A FORMULA: N2 99.9999 ASPHYXIATE ASPHYXIATE
EMERGENCY OVERVIEW: CARBON DIOXIDE EXPOSURE CAN CAUSE NAUSEA AND RESPIRATORY PROBLEMS. HIGH CONCENTRATIONS MAY CAUSE VASODILATATION LEADING TO CIRCULATORY COLLAPSE. ROUTE OF ENTRY: SKIN CONTACT: NO SKIN ABSORPTION: NO EYE CONTACT: NO INHALATION: YES INGESTION: NO HEALTH EFFECTS: EXPOSURE LIMITS: YES IRRITANT: NO SENSITIZATION: NO REPRODUCTIVE HAZARD: NO MUTAGEN: NO CARCINOGENICITY: NTP: NO IARC: NO OSHA: NO EYE EFFECTS: N/A SKIN EFFECTS: N/A INGESTION EFFECTS: INGESTION UNLIKELY. GAS AT ROOM TEMPERATURE. INHALATION EFFECTS: CARBON DIOXIDE IS THE MOST POWERFUL CEREBRAL VASODILATOR KNOWN. INHALING LARGE CONCENTRATIONS CAUSES RAPID CIRCULATORY INSUFFICIENCY LEADING TO COMA AND DEATH. ASPHYXIATION IS LIKELY TO OCCUR BEFORE THE EFFECTS OF CARBON DIOXIDE OVEREXPOSURE. CHRONIC, HARMFUL EFFECTS ARE NOT KNOWN FORM REPEATED INHALATION OF LOW CONCENTRATIONS. LOW CONCENTRATIONS OF CARBON DIOXIDE CAUSE INCREASED RESPIRATION AND HEADACHE. EFFECTS OF OXYGEN DEFICIENCY RESULTING FORM SIMPLE ASPHYXIATION MAY INCLUDE: RAPID BREATHING, DIMINISHED MENTAL ALERTNESS, IMPAIRED MUSCULAR COORDINATION, FAULTY JUDGEMENT, DEPRESSION OF ALL SENSATIONS, EMOTIONAL INSTABILITY, AND FATIGUE. AS ASPHYXIATION PROGRESSES, NAUSEA, VOMITING, PROSTRATION, AND LOSS OF CONSCIOUSNESS MAY RESULT, EVENTUALLY LEADING TO CONVULSIONS, COMA, AND DEATH. NFPA HAZARD CODES: HEALTH 1 FLAMMABILITY 0 REACTIVITY 0 HMIS HAZARD CODES: HEALTH 1 FLAMMABILITY 0 REACTIVITY 0 RATING SYSTEM: 0= NO HAZARD 1= SLIGHT HAZARD 2= MODERATE HAZARD 3= SERIOUS HAZARD 4= SEVERE HAZARD
EYES: N/A SKIN: N/A INGESTION: NOT REQUIRED INHALATION: PROMPT MEDICAL ATTENTION IS MANDATORY IN ALL CASED OF OVEREXPOSURE. RESCUE PERSONNEL SHOULD BE EQUIPPED THE SELF-CONTAINED BREATHING APPARATUS. VICTIMS SHOULD BE ASSISTED TO AN UNCONTAMINATED AREA AND INHALE FRESH AIR. QUICK REMOVAL FROM THE CONTAMINATED AREA IS MOST IMPORTANT. IF BREATHING HAS STOPPED ADMINISTER ARTIFICIAL RESUSCITATION AND SUPPLEMENTAL OXYGEN. FURTHER TREATMENT SHOULD BE SYMPTOMATIC AND SUPPORTIVE.
THESE CONTAINERS HOLD GAS UNDER PRESSURE, WITH NO LIQUID PHASE. IF INVOLVED IN A MAJOR FIRE, THEY SHOULD BE SPRAYED WITH WATER TO AVOID PRESSURE INCREASES, OTHERWISE PRESSURES WILL RISE AND ULTIMATELY THEY MAY DISTORT OR BURST TO RELEASE THE CONTENTS. THE GASES WILL NOT ADD SIGNIFICANTLY TO THE FIRE, BUT CONTAINERS OR FRAGMENTS MAY BE PROJECTED CONSIDERABLE DISTANCES - THEREBY HAMPERING FIRE FIGHTING EFFORTS.
IN TERMS OF WEIGHT, THESE CONTAINERS HOLD VERY LITTLE CONTENTS, SUCH THAT ANY ACCIDENTAL RELEASE BY PUNCTURING ETC. WILL BE OF NO PRACTICAL CONCERN.
SUCK BACK OF WATER INTO THE CONTAINER MUST BE PREVENTED. DO NOT ALLOW BACKFEED INTO THE CONTAINER. USE ONLY PROPERLY SPECIFIED EQUIPMENT WHICH IS SUITABLE FOR THIS PRODUCT, ITS SUPPLY PRESSURE AND TEMPERATURE. USE ONLY IN WELL-VENTILATED AREAS. DO NOT HEAT CYLINDER BY ANY MEANS TO INCREASE RATE OF PRODUCT FROM THE CYLINDER. DO NOT ALLOW THE TEMPERATURE WHERE CYLINDERS ARE STORED TO EXCEED 130 DEG. F (54 DEG. C).
USE ADEQUATE VENTILATION FOR EXTENDED USE OF GAS.
PARAMETER VALUE PHYSICAL STATE GAS EVAPORATION POINT N/A PH N/A ODOR AND APPEARANCE COLORLESS, ODORLESS GAS
STABLE UNDER NORMAL CONDITIONS. EXPECTED SHELF LIFE 48 MONTHS.
CARBON DIOXIDE IS THE MOST POWERFUL CEREBRAL VASODILATOR KNOWN. INHALING LARGE CONCENTRATIONS CAUSES RAPID CIRCULATORY INSUFFICIENCY LEADING TO COMA AND DEATH. CHRONIC, HARMFUL EFFECTS ARE NOT KNOWN FORM REPEATED INHALATION OF LOW (3 TO 5 MOLAR %) CONCENTRATIONS.
NO ECOLOGICAL DAMAGE CAUSED BY THIS PRODUCT.
DO NOT DISCHARGE INTO ANY PLACE WHERE ITS ACCUMULATION COULD BE DANGEROUS. USED CONTAINERS ARE ACCEPTABLE FOR DISPOSAL IN THE NORMAL WASTE STREAM AS LONG AS THE CYLINDER IS EMPTY AND VALVE REMOVED OR CYLINDER WALL IS PUNCTURED; BUT GASCO ENCOURAGES THE CONSUMER TO RETURN CYLINDERS.
UNITED STATES DOT CANADA TDG PROPER SHIPPING NAME COMPRESSED GAS N.O.S. COMPRESSED GAS N.O.S. (CARBON DIOXIDE IN (CARBON DIOXIDE IN NITROGEN) NITROGEN) HAZARD CLASS 2.2 2.2 IDENTIFICATION NUMBER UN1956 UN1956 SHIPPING LABEL NONFLAMMABLE GAS NONFLAMMABLE GAS
CLASSIFIED NON-FLAMMABLE/NON-TOXIC ACCORDING TO DIRECTIVES 88/379/EEC, 67/548/EEC AND THE UK'S CHIP 96 REGULATIONS.
THIS MSDS HAS BEEN PREPARED IN ACCORDANCE WITH THE CHEMICALS (HAZARD INFORMATION AND PACKAGING FOR SUPPLY (AMENDMENT) REGULATION 1996. THE INFORMATION IS BASED ON THE BEST KNOWLEDGE OF GASCO, AND ITS ADVISORS AND IS GIVEN IN GOOD FAITH, BUT WE CANNOT GUARANTEE ITS ACCURACY, RELIABILITY OR COMPLETENESS AND THEREFORE DISCLAIM ANY LIABILITY FOR LOSS OR DAMAGE ARISING OUT OF USE OF THIS DATA. SINCE CONDITIONS OF USE ARE OUTSIDE THE CONTROL OF THE COMPANY AND ITS ADVISORS WE DISCLAIM ANY LIABILITY FOR LOSS OR DAMAGE WHEN THE PRODUCT IS USED FOR OTHER PURPOSES THAN IT IS INTENDED. MSDS/S010/34/ MARCH, 2012 |