SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. PANASONIC SAFETY DATA SHEET DATE ISSUED: FEB. 23 1998 DATE REVISED: AUG. 20 2015
PRODUCT: VALVE REGULATED LEAD ACID BATTERY PANASONIC LC, UP AND EC SERIES COMPANY NAME: PANASONIC STORAGE BATTERY (SHENYANG) CO., LTD. ADDRESS: NO. 17 HUNHE 20TH STREET SHENYANG ECONOMIC & TECHNICAL DEVELOPMENT ZONE CHINA DIVISION: SALES & PLANNING DEPARTMENT TELEPHONE: 024-62786318 FAX.: 024-62786210 CONTACT: VIAN JIAO E-MAIL ADDRESS: IIAOWEI@CN.DANASONIC.COM ISSUED NO.: 002-2015 PANASONIC DEVICES CO. 1701 GOLF ROAD SUITE 3-1100 ROLLING MEADOWS, IL 60008 (800) 793-3772 FOR CHEMICAL EMERGENCY SPILL, LEAK, FIRE, EXPOSURE OR ACCIDENT-CHEMTREC: 1-800-424-9300 OR 1-703-527-3887
AS LONG AS USING IN A RANGE OF CONDITIONS SPECIFIED IN THE MANUFACTURER'S SPECIFICATIONS, VALVE REGULATED LEAD ACID BATTERIES ARE ARTICLES THAT DOES NOT CHANGE THEIR SHAPE AND NATURE FROM THE BEGINNING TO THE END. THIS IDENTIFICATION IS DESCRIBED ASSUMING THAT WHEN HANDLING THESE PRODUCTS, IF THE CONTENTS ARE SPILLED OUT BY DROPPING DAMAGE ETC. FROM THEM, IF THE USED BATTERIES ARE RECYCLED AND IF THE GENERAL USER TOUCHES THE LEAD TERMINALS. GHS CLASSIFICATION ITEM CLASSIFIED RESULT VRLA DISASSEMBLED HAZARD TO HEALTH ACUTE TOXICITY N/A CATEGORY 5 (ORAL) (SULFURIC ACID) ACUTE TOXICITY N/A CATEGORY 2 (INHALATION: (SULFURIC ACID) DUST, MIST) SKIN CORROSION / N/A CATEGORY 1A / 1C IRRITATION (SULFURIC ACID) SERIOUS EYE N/A CATEGORY 1 DAMAGE / EYE (SULFURIC ACID) IRRITATION CATEGORY 2A (LEAD DIOXIDE) GERM CELL CATEGORY 2 CATEGORY 2 MUTAGENICITY (LEAD TERMINAL) (LEAD) CARCINOGENICITY CATEGORY 2 CATEGORY 1B (LEAD TERMINAL) (LEAD SULFIDE) CATEGORY 2 (LEAD & LEAD DIOXIDE) TOXIC TO CATEGORY 1A CATEGORY 1A REPRODUCTION (LEAD TERMINAL) (LEAD, LEAD DIOXIDE & LEAD SULFIDE) SPECIFIC TARGET N/A CATEGORY 1 ORGAN TOXICITY RESPIRATORY TRACT (SINGLE EXPOSURE) (LEAD DIOXIDE & LEAD SULFIDE) SPECIFIC TARGET CATEGORY 1 CATEGORY 1 ORGAN TOXICITY RESPIRATORY RESPIRATORY TRACT (REPEATED TRACT (LEAD, LEAD EXPOSURE) (LEAD TERMINAL) DIOXIDE & LEAD SULFIDE) HAZARD TO AQUATIC HAZARD N/A CATEGORY 1 ENVIRONMENT (ACUTE) (LEAD SULFIDE) CATEGORY 3 (SULFURIC ACID) AQUATIC HAZARD N/A CATEGORY 1 (LONG-TERM) (LEAD SULFIDE) CATEGORY 3 (SULFURIC ACID) GHS LABEL ELEMENTS SKULLS AND HEALTH HAZARD ENVIRONMENT CROSSBONES EXCLAMATION MARK CORROSION ADDITIONAL INFORMATION AT DISASSEMBLED STATE: SIGNAL WORDS: DANGER HAZARD AND TOXICITY INFORMATION: SUSPECTED OF CAUSING GENETIC DEFECTS MAY CAUSE CANCER MAY DAMAGE FERTILITY OR THE UNBORN CHILD CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE NOTE OF CAUTION: SECURITY MEASURES: TO GET THE INSTRUCTION MANUAL BEFORE USE. DO NOT HANDLE UNTIL READ AND UNDERSTOOD ALL SAFETY PRECAUTIONS. TO WEAR PROTECTIVE GLOVES / PROTECTIVE CLOTHING / PROTECTIVE GLASSES / FACE PROTECTION. DO NOT INHALE MIST AND / OR VAPORS. DO NOT EAT, DRINK OR SMOKE WHEN USING THIS PRODUCT. CONCERNING ABOUT THE EXPOSURE OR EXPOSURE, GET MEDICAL ADVICE OR ATTENTION. WHEN I FEEL BAD, OBTAIN MEDICAL ADVICE/ATTENTION. KEEP AWAY FROM IGNITION SOURCES SUCH AS HEAT, SPARKS, OPEN FLAMES AND HIGH TEMPERATURE THINGS. NON SMOKING. DO NOT SPARK OR SHORT WITH TOOLS OR THE LIKE. CHARGE BATTERIES IN A PLACE WHERE IS WELL-VENTILATED. AFTER HANDLING, WASH HANDS THOROUGHLY, RINSE YOUR MOUTH WELL. FIRST AID MEASURES: IF THE ELECTROLYTE (DILUTE SULFURIC ACID) SHOULD COME IN CONTACT WITH YOUR EYES, FLUSH EYES IMMEDIATELY WITH PLENTY OF CLEAR WATER FOR AT LEAST 15 MINUTES THEN TO GET MEDICAL ADVICE OR ATTENTION OF OPHTHALMOLOGIST IF THE ELECTROLYTE (DILUTE SULFURIC ACID) IS ATTACHED TO THE SKIN, TO RINSE IMMEDIATELY WITH PLENTY OF WATER THEN WASH THOROUGHLY WITH SOAP. IF SWALLOWED ELECTROLYTE (DILUTE SULFURIC ACID), WASH YOUR MOUTH WITH PLENTY OF WATER IMMEDIATELY THEN TO DRINK PLENTY OF WATER AND OBTAIN MEDICAL ADVICE OR ATTENTION. DO NOT INDUCE VOMITING WHEN SWALLOWED. IN ADDITION, NOT PERFORM ANY ACTION, SUCH AS NEUTRALIZATION PROCESS. IF THE ELECTROLYTE (DILUTED SULFURIC ACID) IS ATTACHED TO THE GARMENT, IT TOOK OFF ALL CONTAMINATED CLOTHING IMMEDIATELY. BEFORE REUSE THE CLOTHING TO WASH THEM WITHOUT FAIL. RECOVERING THE SPILLED MATERIAL. STORAGE: KEEP LOCKED UP. TO STORE WHERE FREE FROM TO RECEIVE HIGH TEMPERATURE, HIGH HUMIDITY, DOURO, DIRECT SUNLIGHT AND / OR A PLACE THAT IS NOT POTENTIALLY HAZARDOUS GASES, DROPLETS, DUST GENERATION AND INGRESSION OR SUBMERGED. STORE IN A PLACE WHERE THERE IS NO FIRE. DISPOSAL: BE RECYCLED BY THE LAWS OR REGULATIONS OF EACH COUNTRY.
HAZARDS INGREDIENTS: SPECIFIC CHEMICAL IDENTITY % BY WT. CHEMICAL SYMBOL CAS NO. LEAD 55 - 85 Pb 7439-92-1 LEAD DIOXIDE " PbO2 1309-60-0 LEAD SULFATE " PbSO4 7446-14-2 SULFURIC ACID 10 - 30 H2SO4 + H2O 7664-93-9
INHALATION: SULFURIC ACID: TO WRAP IN A BLANKET THE PATIENT IMMEDIATELY, WHEN THE INHALATION OF SULFURIC ACID MIST OR VAPOR, THEN TRANSFER FROM THE INHALED LOCATION TO A PLACE WHERE FRESH AIR CAN BE OBTAINED. TO GET MEDICAL ADVICE / ATTENTION IMMEDIATELY. SKIN: SULFURIC ACID: IF THIS LIQUID IS ATTACHED TO THE SKIN, WASH IMMEDIATELY WITH PLENTY OF WATER THEN WASH THOROUGHLY WITH SOAP. THE PARTS WHERE LIQUID IS ATTACHED TAKE OFF SUCH CLOTHING, SHOES AND SOCKS, THEN KEEP AWAY THEM. THE BODY PARTS OF CONTACT WITH THE LIQUID IS WASHED WATER CONTINUOUSLY, THEN RAPPED IN A STERILE DRESSING (NOT BE USED FOR BURN DRESSINGS). LEAD: THE PARTS WHERE LIQUID IS ATTACHED TAKE OFF SUCH CLOTHING, SHOES AND SOCKS, THEN KEEP AWAY THEM. THE BODY PARTS IN CONTACT WITH THIS SUBSTANCE IS RINSED WITH WATER CONTINUOUSLY. EYE: SULFURIC ACID: IMMEDIATELY RINSE WITH PLENTY OF CLEAR WATER FOR AT LEAST 15 MINUTES WITH THUMB AND FOREFINGER AND SPREAD THE EYELIDS, AT THE SAME TIME, THE EYES MOVE IN ALL DIRECTIONS. IF EYE IRRITATION PERSISTS, OBTAIN MEDICAL ADVICE AND TREATMENT. LEAD: IMMEDIATELY RINSE WITH PLENTY OF CLEAR WATER FOR AT LEAST 10-15 MINUTES WITH THUMB AND FOREFINGER AND SPREAD THE EYELIDS, AT THE SAME TIME, THE EYES MOVE IN ALL DIRECTIONS. INGESTION: SULFURIC ACID: IF SWALLOWED THIS LIQUID, WASH YOUR MOUTH WITH PLENTY OF WATER IMMEDIATELY THEN TO DRINK PLENTY OF WATER AND OBTAIN MEDICAL ADVICE OR ATTENTION. DO NOT INDUCE VOMITING WHEN SWALLOWED. IN ADDITION, NOT PERFORM ANY ACTION, SUCH AS NEUTRALIZATION PROCESS.
EXTINGUISHING MEDIA: SMALL FIRE: FOAM HALOGEN AND/OR NONINFLAMMABLE GAS FIRE EXTINGUISHER BIG FIRE: LARGE QUANTITIES OF SPRINKLED AND/OR ATOMIZED WATER. (IN THIS CASE TO PREVENT ENVIRONMENTAL DAMAGE, FLUSH WATER HAS TO TREAT APPROPRIATELY.) PARTICULAR HAZARDS: IRRITATE, CORROSIVE AND/OR TOXICITY GASES MAY BREAK OUT FROM THE BURNING BATTERY. PROPER FIRE FIGHTING: IF POSSIBLE, TURN OFF THEIR POWER FIRST WHEN BATTERIES ARE ON CHARGE OR REMOVE IGNITION SOURCE AND REMOVE BATTERIES FROM THE FIRE PLACE. EXTINGUISH OUT THE FIRE FROM WHERE WELL AIR FLOW AND WINDWARD. EXTINCTION WATER HAS TO TREAT APPROPRIATELY FOR PREVENTING ENVIRONMENTAL DAMAGE. COOL DOWN ENOUGH THE BURNT BATTERIES WITH PLENTY AMOUNT OF WATER. TRY TO PUT OUT FIRE IN EARLY STAGE. IN THIS CASE TO USE PROTECTORS WRITTEN BELOW. PROTECTION FOR FIRE-FIGHTER: USE POSITIVE PRESSURE, SELF-CONTAINED BREATHING APPARATUS AND WEAR ACID-RESISTANT FACE SHIELD, GLOVES AND BOOTS IN FIGHTING FIRE.
SPILLAGE OF ELECTROLYTE (SULFURIC ACID): HUMAN BODY: DO NOT TOUCH THE SPILLED ELECTROLYTE, AND WALK AROUND THE SPILLAGE PLACE. KEEP OUT OUTSIDERS FROM THE SPILLAGE PLACE. ENVIRONMENT: SPILLED ELECTROLYTE HAS TO TREAT APPROPRIATELY FOR PREVENTING ENVIRONMENTAL DAMAGE, SUCH AS DIRECT OUT FLOWING OF THE SPILLED ELECTROLYTE INTO THE RIVER, DRAIN, ETC.. NEUTRALIZATION: NEUTRALIZE SPILLED ELECTROLYTE WITH SODIUM BICARBONATE, LIME, ETC. AND FLUSH WITH LARGE QUANTITIES OF WATER. IN THIS CASE TO USE PROTECTORS PROPERLY.
HANDLING: KEEP AWAY FROM FIRE AND SPARKS. HANDLE WITH CARE AND KEEP AWAY FROM SHOCK, UPSET, ETC.. DO NOT SHORT-CIRCUIT BOTH BATTERY TERMINALS. CHARGE LEAD ACID STARTER BATTERY IN WELL VENTILATED AREAS. STORAGE: STORE LEAD ACID STARTER BATTERY IN COOL AND DRY AREAS. BATTERIES SHOULD ALSO BE STORED UNDER PROTECTION AGAINST RAIN, DEW AND SUNLIGHT. KEEP AWAY FROM FIRE, DUST SOURCE, HARMFUL GAS AND IMMERSION.
NOT APPLICABLE FOR VALVE REGULATED LEAD ACID BATTERY.
NOT APPLICABLE FOR VALVE REGULATED LEAD ACID BATTERY. REFERENCE (COMPONENT): ELECTROLYTE (SULFURIC ACID) LEAD APPEARANCE CLEAR SILVERY SOLID SPECIFIC GRAVITY 1.280 - 1.380 (38 - 48%) 11.3 BOILING POINT 112 DEG. C (38%) 1740 DEG. C MELTING POINT - 40 DEG. C OR BELOW 327 DEG. C SOLIDIFYING POINT - 56.4 DEG. C (34.6 %) VAPOR PRESSURE 3.17 KPA (30%) 0.1 PA OR LESS (25 DEG. C)
STABILITY: DILUTE SULFURIC ACID: WHEN RAPIDLY IN CONTACT WITH WATER, LARGE AMOUNT OF HEAT GENERATION MAY BE SCATTERED ACID REACTIVITY: DILUTE SULFURIC ACID: THE CONCENTRATION, THE TEMPERATURE AND TYPE OF METAL, SULFURIC ACID THE PRODUCES H2O, H2S, SO2, S AND A SULFIDE OR SULFATE OF METAL. TO GENERATE HYDROGEN BY REACTING WITH THE METAL IONIZATION TENDENCY LARGER THAN HYDROGEN. LEAD: MAY REACT WITH ACIDS AND STRONG ACIDS. DECOMPOSITION PRODUCTS: H2S, SOX CAUSE VERY HARMFUL GAS BY HEATING AND CHEMICAL REACTIONS.
CORRESPOND TO SECTION 2
CORRESPOND TO SECTION 2
SEND IDLE BATTERY TO LEAD SMELTER FOR MATERIAL RECYCLING UNDER APPLICABLE STATE AND/OR LOCAL LAW AND REGULATIONS.
SPECIAL CARE: IT IS DESIRABLE TO DEVOTE EFFORT TO KEEP BATTERY TEMPERATURE BELOW 40 DEG. C THROUGH THE TRANSPORTATION. KEEP AWAY FROM FIRE, HOT AIR, HIGH HUMIDITY, RAIN AND DEW AND DIRECT SUNLIGHT. IF POSSIBLE, AVOID CONSOLIDATED TRANSPORTATION WITH OTHER MATERIAL. HANDLE WITH CARE TO AVOID ACID SPILLAGE DUE TO DROP AND/OR UPSET. BE AWARE OF BATTERY WEIGHT AND TAKE CARE OF BATTERY HANDLING. UN RECOMMENDATION ON TRANSPORTATION: IMO ICAO/IATA UN NUMBER 2800 DANGEROUS GOODS 8 SPECIAL PROVISION 238 A48, A67, A164, A183 US DOT REGULATION LABELING 49 CFR 173.159 (D) NONSPILLABLE HS CODE: 8507.20 (OTHER LEAD ACID BATTERIES) COUNTRY OF ORIGIN: JAPAN / REPUBLIC OF CHINA
CALIFORNIA PROPOSITION 65: THE STATE OF CALIFORNIA HAS DETERMINED THAT CERTAIN BATTERY TERMINALS CONTAIN LEAD AND LEAD COMPOUNDS, CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND REPRODUCTIVE HARM. IMPORTANT: WASH HANDS THOROUGHLY AFTER WORKING WITH BATTERIES AND BEFORE EATING, DRINKING OR SMOKING. TSCA: NOT APPLICABLE FOR VALVE REGULATED LEAD ACID BATTERY
NOTICE TO READERS: THIS INFORMATION HAS BEEN COMPLIED FROM SOURCES CONSIDERED TO BE DEPENDABLE AND IS, TO THE BEST OF OUR KNOWLEDGE AND BELIEF, ACCURATE AND RELIABLE AS OF THE DATE COMPLIED. HOWEVER, NO REPRESENTATION, WARRANTY (EITHER EXPRESSED OR IMPLIED) OR GUARANTEE IS MADE TO THE ACCURACY, RELIABILITY OR COMPLETENESS OF THE INFORMATION CONTAINED HEREIN. THIS INFORMATION RELATES TO THE SPECIFIC MATERIAL DESIGNATED AND MAY NOT BE VALID FOR SUCH MATERIAL USED IN COMBINATION WITH ANY OTHER MATERIALS OR IN ANY PROCESS. IT IS THE USE'S RESPONSIBILITY TO SATISFY HIMSELF AS TO THE SUITABILITY AND COMPLETENESS OF THIS INFORMATION FOR HIS OWN PARTICULAR USE. ELECTROCHEMICAL EQUATION: POSI. ELECTROLYTE NEGA. PbO2 + 2H2SO4 + Pb CHG.<--- --->DISCHG. LEAD DIOXIDE SULFURIC ACID LEAD POSI. ELECTROLYTE NEGA. PbSO4 + 2H2O + PbSO4 LEAD SULFATE WATER LEAD SULFATE |