Common Name: NICKEL CADMIUM BATTERY
Manufacturer: JIANGSU HIGHSTAR BATTERY MANUFACTURING CHINA
SDS Revision Date: 1/21/2015
SDS Format: GHS-US
   
Item Number(s): 2HNX5, 2HNX6, 2XLE7
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE 
2. HAZARDS IDENTIFICATION 
3. COMPOSITION/INFORMATION ON INGREDIENTS 
4. FIRST AID MEASURES 
5. FIRE-FIGHTING MEASURES 
6. ACCIDENTAL RELEASE MEASURES 
7. HANDLING AND STORAGE 
8. EXPOSURE CONTROLS/PERSONAL PROTECTION 
9. PHYSICAL AND CHEMICAL PROPERTIES 
10. STABILITY AND REACTIVITY 
11. TOXICOLOGICAL INFORMATION 
12. ECOLOGICAL INFORMATION 
13. DISPOSAL CONSIDERATIONS 
14. TRANSPORT INFORMATION 
15. REGULATORY INFORMATION 
16. OTHER INFORMATION 



ITW RAMSET GAS TOOL BATTERY

SAFETY DATA SHEET

HCS-2012 APPENDIX D TO SUBSECTION 1910.1200

VERSION: 1

ISSUE DATE: 21-JAN-2015

PRODUCT NAME: NICKEL CADMIUM BATTERY

REVISION DATE: 21-JAN-2015


1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE 

               AND OF THE COMPANY/UNDERTAKING

PRODUCT IDENTIFIER:

PRODUCT NAME: NICKEL CADMIUM BATTERY

CHEMICAL NAME: NICKEL CADMIUM BATTERY

OTHER MEANS OF IDENTIFICATION:

RECOMMENDED USE OF THE CHEMICAL AND RESTRICTIONS ON USE:
RECOMMENDED USE: USED IN ELECTRIC TOOLS
USES ADVISED AGAINST: NO INFORMATION AVAILABLE

DETAILS OF THE SUPPLIER OF THE SAFETY DATA SHEET:

SUPPLIER: JIANGSU HIGHSTAR BATTERY MANUFACTURING CO.,LTD.

ADDRESS:
NO. 306 HEPING ROAD(S)
QIDONG CITY, JIANGSU
CHINA

POSTAL CODE: 226200

PHONE: 0086-513-80795666

FAX: 0086-513-83312306

E-MAIL: CHENJ@HIGHSTAR.NET.CN

EMERGENCY TELEPHONE NUMBER: 0086-513-80795666


2. HAZARDS IDENTIFICATION 


GHS CLASSIFICATION:
NOT A DANGEROUS SUBSTANCE OR MIXTURE ACCORDING TO THE GLOBALLY HARMONIZED
SYSTEM (GHS)

LABEL ELEMENTS:
SYMBOLS/PICTOGRAMS: NONE
SIGNAL WORD: NONE
HAZARD STATEMENTS: NONE

PRECAUTIONARY STATEMENTS:
PREVENTION: NONE
RESPONSE: NONE
STORAGE: NONE
DISPOSAL: NONE

HAZARDS NOT OTHERWISE CLASSIFIED (HNOC): NO INFORMATION AVAILABLE

UNKNOWN ACUTE TOXICITY:
.?% OF THE MIXTURE CONSISTS OF INGREDIENT(S) OF UNKNOWN TOXICITY


3. COMPOSITION/INFORMATION ON INGREDIENTS 


CHEMICAL NATURE: MIXTURE

CHEMICAL NAME                       CAS NO              WEIGHT-%

NICKEL                               7440-02-0          10 - 25

CADMIUM AND COMPOUNDS (AS Cd)        7440-43-9          10 - 25

CADMIUM HYDROXIDE (Cd(OH)2)         21041-95-2          12 - 23

NICKEL HYDROXIDE                    12054-48-7           6 - 14

IRON                                 7439-89-6          10 - 13


4. FIRST AID MEASURES 


DESCRIPTION OF FIRST AID MEASURES:

GENERAL ADVICE:
REMOVE CONTAMINATED CLOTHING AND SHOES. IF SYMPTOMS PERSIST, CALL A
PHYSICIAN.

INHALATION: NOT AN EXPECTED ROUTE OF EXPOSURE.

IF INHALED:
REMOVE VICTIM TO FRESH AIR AND KEEP AT REST IN A POSITION COMFORTABLE FOR
BREATHING.

SKIN CONTACT: WASH HANDS THOROUGHLY AFTER HANDLING..

EYE CONTACT: NOT AN EXPECTED ROUTE OF EXPOSURE..

INGESTION:
RINSE MOUTH GET MEDICAL ATTENTION NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON

MOST IMPORTANT SYMPTOMS AND EFFECTS, BOTH ACUTE AND DELAYED:
NO INFORMATION AVAILABLE.

INDICATION OF ANY IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT NEEDED:
TREAT SYMPTOMATICALLY.


5. FIRE-FIGHTING MEASURES 


EXTINGUISHING MEDIA:

SUITABLE EXTINGUISHING MEDIA:
USE EXTINGUISHING MEASURES THAT ARE APPROPRIATE TO LOCAL CIRCUMSTANCES AND
THE SURROUNDING ENVIRONMENT.

UNSUITABLE EXTINGUISHING MEDIA: NO INFORMATION AVAILABLE.

SPECIFIC HAZARDS ARISING FROM THE CHEMICAL:
THERMAL DECOMPOSITION CAN LEAD TO RELEASE OF IRRITATING AND TOXIC GASES AND
VAPORS

PROTECTIVE EQUIPMENT AND PRECAUTIONS FOR FIREFIGHTERS:
AS IN ANY FIRE, WEAR SELF-CONTAINED BREATHING APPARATUS PRESSURE-DEMAND,
MSHA/NIOSH (APPROVED OR EQUIVALENT) AND FULL PROTECTIVE GEAR.


6. ACCIDENTAL RELEASE MEASURES 


PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:
EVACUATE PERSONNEL TO SAFE AREAS
ENSURE ADEQUATE VENTILATION, ESPECIALLY IN CONFINED AREAS
REMOVE ALL SOURCES OF IGNITION
USE PERSONAL PROTECTION RECOMMENDED IN SECTION 8

METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP:
PREVENT FURTHER LEAKAGE OR SPILLAGE IF SAFE TO DO SO
PICK UP AND TRANSFER TO PROPERLY LABELED CONTAINERS

AVOID RELEASE TO THE ENVIRONMENT


7. HANDLING AND STORAGE 


PRECAUTIONS FOR SAFE HANDLING:
HANDLE IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE AND SAFETY PRACTICE
ENSURE ADEQUATE VENTILATION, ESPECIALLY IN CONFINED AREAS
AVOID CREATING DUST
AVOID CONTACT WITH EYES
WASH THOROUGHLY AFTER HANDLING
USE PERSONAL PROTECTION RECOMMENDED IN SECTION 8

CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES:
KEEP CONTAINERS TIGHTLY CLOSED IN A DRY, COOL AND WELL-VENTILATED PLACE
KEEP AWAY FROM HEAT


8. EXPOSURE CONTROLS/PERSONAL PROTECTION 


CONTROL PARAMETERS:

CHEMICAL NAME  ACGIH TLV    OSHA PEL      NIOSH IDLH   DENMARK     EUROPEAN
                                                                   UNION

NICKEL         TWA:         TWA:          IDLH:        TWA:
(CAS #:        1.5 MG/M3    1 MG/M3       10 MG/M3     0.05 MG/M3
7440-02-0)     INHALABLE    (VACATED)
               FRACTION                   IDLH:
                            TWA:          10 MG/M3
                            1 MG/M3       Ni

                                          TWA:
                                          0.015 MG/M3

                                          TWA:
                                          0.015 MG/M3
                                          EXCEPT
                                          NICKEL
                                          CARBONYL Ni

CADMIUM AND    TWA:         TWA:          IDLH:        TWA:
COMPOUNDS      0.01 MG/M3   0.1 MG/M3     9 MG/M3      0.005
(CAS #:                     FUME          DUST         MG/M3
7440-43-9)     TWA:         APPLIES
(AS Cd)        0.002        TO ANY        IDLH:
               MG/M3        OPERATIONS    9 MG/M3 Cd
               RESPIRABLE   OR SECTORS    DUST AND
               FRACTION     FOR WHICH     FUME
                            THE
               TWA:         CADMIUM
               0.01 MG/M3   STANDARD
               Cd           IS STAYED
                            OR
               TWA:         OTHERWISE
               0.002 MG/M3  NOT IN
               Cd           EFFECT
               RESPIRABLE
               FRACTION     TWA:
                            0.2 MG/M3
                            DUST
                            APPLIES TO
                            ANY
                            OPERATIONS
                            OR SECTORS
                            FOR WHICH
                            THE
                            CADMIUM
                            STANDARD
                            IS STAYED
                            OR
                            OTHERWISE
                            NOT IN
                            EFFECT

                            TWA:
                            5
                            (MICRO)G/M3

                            (VACATED)
                            STEL:
                            0.3 PPM
                            FUME

                            CEILING:
                            0.3 MG/M3
                            FUME
                            APPLIES TO
                            ANY
                            OPERATIONS
                            OR SECTORS
                            FOR WHICH
                            THE CADMIUM
                            STANDARD IS
                            STAYED OR
                            OTHERWISE
                            NOT IN
                            EFFECT

                            CEILING:
                            0.6 MG/M3
                            DUST
                            APPLIES TO
                            ANY
                            OPERATIONS
                            OR SECTORS
                            FOR WHICH
                            THE CADMIUM
                            STANDARD
                            IS STAYED
                            OR
                            OTHERWISE
                            NOT IN
                            EFFECT

CADMIUM        TWA:                                    TWA:
HYDROXIDE      0.01 MG/M3                              0.005
(Cd(OH)2)      Cd                                      MG/M3
(CAS #:
21041-95-2)    TWA:
               0.002
               MG/M3 Cd
               RESPIRABLE
               FRACTION

NICKEL         TWA:         TWA:          IDLH:        TWA:
HYDROXIDE      0.2 MG/M3    1 MG/M3 Ni    10 MG/M3     0.05
(CAS #:        Ni                         Ni           MG/M3
12054-48-7)    INHALABLE    (VACATED)
               FRACTION     TWA:          TWA:
                            1 MG/M3 Ni    0.015 MG/M3
                                          EXCEPT
                                          NICKEL
                                          CARBONYL Ni

CHEMICAL NAME   LATVIA      FRANCE      FINLAND         GERMANY      ITALY

NICKEL          TWA:        TWA:        TWA: 1 MG/M3    SKIN
(CAS #:         0.05        1 MG/M3
7440-02-0)      MG/M3                   TWA:
                                        0.1 MG/M3

CADMIUM AND     TWA:        TWA:        TWA:            SKIN
COMPOUNDS       0.01 MG/M3  0.05 MG/M3  0.02 MG/M3
(AS Cd)                                 SKIN
(CAS #:         STEL:
7440-43-9)      0.05 MG/M3

NICKEL          TWA:        TWA:        TWA: 0.1 MG/M3  SKIN
HYDROXIDE       0.05 MG/M3  1 MG/M3
(CAS #:
12054-48-7)

CHEMICAL NAME   POLAND       PORTUGAL   SPAIN    SWITZERLAND    NETHERLANDS

NICKEL          TWA:         TWA:       TWA:     TWA:
(CAS #:         0.25 MG/M3   1.5 MG/M3  1 MG/M3  0.5 MG/M3
7440-02-0)

CADMIUM AND     TWA:         TWA:       TWA:     SKIN
COMPOUNDS       0.01 MG/M3   0.01       0.01
(AS Cd)                      MG/M3      MG/M3
CAS #:          TWA:
7440-43-9)      0.002 MG/M3  TWA:       TWA:     TWA:
                             0.002      0.002    0.015 MG/M3
                             MG/M3      MG/M3

NICKEL          TWA:         TWA:       TWA:     TWA:
HYDROXIDE       0.25 MG/M3   0.2 MG/M3  0.2      0.05 MG/M3
(CAS #:                                 MG/M3
12054-48-7)

CHEMICAL NAME   NORWAY       UNITED KINGDOM   AUSTRALIA    AUSTRIA  BELGIUM

NICKEL          TWA:         STEL: 1.5 MG/M3  1 MG/M3
(CAS #:         0.05 MG/M3   TWA: 0.5 MG/M3
7440-02-0)
                STEL:
                0.15 MG/M3

CADMIUM AND     TWA:         STEL:            0.01 MG/M3
COMPOUNDS       0.05 MG/M3   0.075 MG/M3
(AS Cd)
(CAS #:         STEL:        TWA:
7440-43-9)      0.15 MG/M3   0.025 MG/M3

CADMIUM                                       0.01 MG/M3
HYDROXIDE
(Cd(OH)2)
(CAS #:
21041-95-2)

NICKEL          TWA:         TWA:
HYDROXIDE       0.05 MG/M3   0.5 MG/M3
(CAS #:
12054-48-7)     STEL:
                0.15 MG/M3

APPROPRIATE ENGINEERING CONTROLS:
SHOWERS
EYEWASH STATIONS
VENTILATION SYSTEMS

INDIVIDUAL PROTECTION MEASURES, SUCH AS PERSONAL PROTECTIVE EQUIPMENT:

RESPIRATORY PROTECTION:
IF EXPOSURE LIMITS ARE EXCEEDED OR IRRITATION IS EXPERIENCED, NIOSH/MSHA
APPROVED RESPIRATORY PROTECTION SHOULD BE WORN. POSITIVE-PRESSURE SUPPLIED
AIR RESPIRATORS MAY BE REQUIRED FOR HIGH AIRBORNE CONTAMINANT
CONCENTRATIONS. RESPIRATORY PROTECTION MUST BE PROVIDED IN ACCORDANCE WITH
CURRENT LOCAL REGULATIONS.

HAND PROTECTION: WEAR PROTECTIVE GLOVES.

EYE/FACE PROTECTION:
NO SPECIAL TECHNICAL PROTECTIVE MEASURES ARE NECESSARY.

SKIN AND BODY PROTECTION: WEAR SUITABLE PROTECTIVE CLOTHING.


9. PHYSICAL AND CHEMICAL PROPERTIES 


INFORMATION ON BASIC PHYSICAL AND CHEMICAL PROPERTIES:

APPEARANCE: SOLID

COLOR: NO INFORMATION AVAILABLE

ODOR: ODORLESS

ODOR THRESHOLD: NOT DETERMINED

PH: NOT DETERMINED

MELTING POINT/FREEZING POINT: NOT DETERMINED

BOILING POINT / BOILING RANGE: NOT DETERMINED

FLASH POINT: NOT APPLICABLE

EVAPORATION RATE: NOT DETERMINED

FLAMMABILITY (SOLID, GAS): NOT DETERMINED

FLAMMABILITY LIMIT IN AIR: NOT DETERMINED

VAPOR PRESSURE: NOT APPLICABLE

VAPOR DENSITY: NOT DETERMINED

DENSITY: NOT DETERMINED

RELATIVE DENSITY: NOT DETERMINED

BULK DENSITY: NOT DETERMINED

SPECIFIC GRAVITY: NOT DETERMINED

WATER SOLUBILITY: NOT DETERMINED

PARTITION COEFFICIENT (LOGPOW): NOT DETERMINED

AUTOIGNITION TEMPERATURE: NOT DETERMINED

DECOMPOSITION TEMPERATURE: NOT DETERMINED

KINEMATIC VISCOSITY: NOT DETERMINED

DYNAMIC VISCOSITY: NOT DETERMINED

EXPLOSIVE PROPERTIES: NOT AN EXPLOSIVE

OXIDIZING PROPERTIES: NOT DETERMINED

OTHER INFORMATION: NO INFORMATION AVAILABLE


10. STABILITY AND REACTIVITY 


REACTIVITY:
STABLE UNDER RECOMMENDED STORAGE AND HANDLING CONDITIONS (SEE SECTION 7,
HANDLING AND STORAGE).

CHEMICAL STABILITY: STABLE UNDER NORMAL CONDITIONS

POSSIBILITY OF HAZARDOUS REACTIONS: NONE UNDER NORMAL PROCESSING

CONDITIONS TO AVOID: STRONG HEATING. INCOMPATIBLE MATERIALS

INCOMPATIBLE MATERIALS: STRONG ACIDS STRONG BASES STRONG OXIDIZING AGENTS

HAZARDOUS DECOMPOSITION PRODUCTS: NONE KNOWN BASED ON INFORMATION SUPPLIED


11. TOXICOLOGICAL INFORMATION 


INFORMATION ON LIKELY ROUTES OF EXPOSURE:

INHALATION:
INHALATION OF VAPORS IN HIGH CONCENTRATION MAY CAUSE IRRITATION OF
RESPIRATORY SYSTEM

EYE CONTACT: CONTACT WITH EYES MAY CAUSE IRRITATION

SKIN CONTACT: SUBSTANCE MAY CAUSE SLIGHT SKIN IRRITATION

INGESTION: MAY CAUSE IRRITATION TO MUCOUS MEMBRANES

INFORMATION ON TOXICOLOGICAL EFFECTS:

ACUTE TOXICITY:

CHEMICAL NAME        ORAL LD50       DERMAL LD50       INHALATION LC50

NICKEL               >9000 MG/KG
(CAS #: 7440-02-0)   (RAT)

CADMIUM AND          = 2330 MG/KG                      = 25 MG/M3 (RAT)
COMPOUNDS (AS Cd)    (RAT)                             30 MIN
(CAS #: 7440-43-9)

NICKEL HYDROXIDE                                       = 1200 MG/M3 (RAT)
(CAS #: 12054-48-7)                                    4 H

IRON                 98.6 G/KG BW
(CAS #: 7439-89-6)   (RAT)

SKIN CORROSION/IRRITATION: NON-IRRITATING TO THE SKIN

SERIOUS EYE DAMAGE/EYE IRRITATION: NO EYE IRRITATION

SENSITIZATION: NO INFORMATION AVAILABLE

GERM CELL MUTAGENICITY: NO INFORMATION AVAILABLE

CARCINOGENICITY:
THIS PRODUCT DOES NOT CONTAIN ANY CARCINOGENS OR POTENTIAL CARCINOGENS AS
LISTED BY OSHA IARC OR NTP

CHEMICAL NAME           ACGIH       IARC            NTP                OSHA

NICKEL                              GROUP 2B        KNOWN REASONABLY   X
(CAS #: 7440-02-0)                                  ANTICIPATED

CADMIUM AND             A2          GROUP 1         KNOWN              X
COMPOUNDS (AS Cd)
(CAS #: 7440-43-9)

CADMIUM HYDROXIDE       A2
(Cd(OH)2)
(CAS #: 21041-95-2)

NICKEL HYDROXIDE        A1          GROUP 1         KNOWN              X
(CAS #: 12054-48-7)

REPRODUCTIVE TOXICITY: NO INFORMATION AVAILABLE

STOT - SINGLE EXPOSURE: NO INFORMATION AVAILABLE

STOT - REPEATED EXPOSURE: NO INFORMATION AVAILABLE

ASPIRATION HAZARD: NO INFORMATION AVAILABLE


12. ECOLOGICAL INFORMATION 


ECOTOXICITY:

CHEMICAL NAME  ALGAE/AQUATIC          FISH LC50          CRUSTACEA EC50
               PLANTS EC50

NICKEL         0.18 MG/L/72H          100 MG/L/96H       100 MG/L/48H
(CAS #:        PSEUDOKIRCHNERIELLA    BRACHYDANIO        DAPHNIA MAGNA
7440-02-0)     SUBCAPITATA            RERIO
                                                         1 MG/L/48H DAPHNIA
               0.174 - 0.311          1.3 MG/L/96H       MAGNA STATIC
               MG/L/96H               CYPRINUS CARPIO
               PSEUDOKIRCHNERIELLA    SEMI-STATIC
               SUBCAPITATA STATIC
                                      10.4 MG/L/96H
                                      CYPRINUS CARPIO
                                      STATIC

CADMIUM AND                           0.003:             0.0244:
COMPOUNDS                             96 H               48 H DAPHNIA MAGNA
(AS Cd)                               ONCORHYNCHUS       MG/L EC50 STATIC
(CAS #:                               MYKISS MG/L LC50
7440-43-9)                            FLOW-THROUGH

                                      0.006:
                                      96 H
                                      ONCORHYNCHUS
                                      MYKISS MG/L
                                      LC50 STATIC

                                      0.002:
                                      96 H CYPRINUS
                                      CARPIO MG/L
                                      LC50

                                      4.26:
                                      96 H CYPRINUS
                                      CARPIO MG/L
                                      LC50 SEMI-
                                      STATIC

                                      0.24:
                                      96 H CYPRINUS
                                      CARPIO MG/L
                                      LC50 STATIC

                                      21.1:
                                      96 H LEPOMIS
                                      MACROCHIRUS
                                      MG/L LC50
                                      FLOW-THROUGH

                                      0.016:
                                      96 H ORYZIAS
                                      LATIPES MG/L
                                      LC50

                                      0.0004 - 0.003:
                                      96 H PIMEPHALES
                                      PROMELAS MG/L
                                      LC50

IRON                                                     >100 MG/L/48H
(CAS #:                                                  (DAPHNIA MAGNA)
7439-89-6)

PERSISTENCE AND DEGRADABILITY: NO INFORMATION AVAILABLE

BIOACCUMULATIVE POTENTIAL: NO INFORMATION AVAILABLE

MOBILITY IN SOIL: NO INFORMATION AVAILABLE

OTHER ADVERSE EFFECTS: NO INFORMATION AVAILABLE


13. DISPOSAL CONSIDERATIONS 


WASTE TREATMENT METHODS:

DISPOSAL OF WASTES:
DISPOSAL SHOULD BE IN ACCORDANCE WITH APPLICABLE REGIONAL, NATIONAL AND
LOCAL LAWS AND REGULATIONS

CONTAMINATED PACKAGING:
DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS

CHEMICAL NAME   RCRA      RCRA - BASIS     RCRA - D          RCRA - U
                          FOR LISTING      SERIES WASTES     SERIES WASTES

NICKEL                    INCLUDED IN
7440-02-0                 WASTE
                          STREAMS:
                          F006, F039

CADMIUM AND               INCLUDED IN      1.0 MG/L
COMPOUNDS                 WASTE            REGULATORY
(AS Cd)                   STREAMS:         LEVEL
7440-43-9                 F006, F039,
                          K061, K069,
                          K100

CHEMICAL NAME                   CALIFORNIA HAZARDOUS WASTE STATUS

NICKEL                          TOXIC POWDER
7440-02-0                       IGNITABLE POWDER


14. TRANSPORT INFORMATION 


IT IS CONSIDERED AS NON-DANGEROUS GOOD BY THE ICAO, IATA, IMDG AND TDG.

ACCORDING TO IATA DGR 56TH EDITION FOR TRANSPORTATION AND INTERNATIONAL
MARITIME DANGEROUS GOODS (IMDG CODE 36TH) AND THE RECOMMENDATION ON THE
TRANSPORTATION OF DANGEROUS GOODS-MODEL REGULATION (18TH) / THE PRODUCTS
ARE NOT SUBJECTS/SUBJECT TO DANGEROUS.

DOT / IMDG / IATA:
UN/ID NO.: NOT REGULATED
PROPER SHIPPING NAME: NOT REGULATED
HAZARD CLASS: NOT REGULATED
PACKING GROUP: NOT REGULATED
SPECIAL PRECAUTIONS: NO INFORMATION AVAILABLE
MARINE POLLUTANT: NOT APPLICABLE


15. REGULATORY INFORMATION 


INTERNATIONAL INVENTORIES:

COMPONENT         AICS  DSL/NDSL  EINECS/  ENCS  IECSC  KECL  PICCS  TSCA
                                  ELINCS

NICKEL            X     X         X        -     X      X     X      X
7440-02-0
(10 - 30)

CADMIUM AND       X     X         X        -     X      X     X      X
COMPOUNDS
(AS Cd)
7440-43-9
(10 - 30)

CADMIUM           X     X         -        -     X      -     -      -
HYDROXIDE
(Cd(OH)2)
21041-95-2
(10 - 30)

NICKEL            X     X         X        X     X      X     X      X
HYDROXIDE
12054-48-7
(10 - 30)

IRON              X     X         X        -     X      X     X      X
7439-89-6
(10 - 30)

"-" NOT LISTED
"X" LISTED

US FEDERAL REGULATIONS:

SARA 313:
SECTION 313 OF TITLE III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION
ACT OF 1986 (SARA). THIS PRODUCT CONTAINS A CHEMICAL OR CHEMICALS WHICH ARE
SUBJECT TO THE REPORTING REQUIREMENTS OF THE ACT AND TITLE 40 OF THE CODE
OF FEDERAL REGULATIONS, PART 372

CHEMICAL NAME                        SARA 313 - THRESHOLD VALUES %

NICKEL - 7440-02-0                   0.1

CADMIUM AND COMPOUNDS (AS Cd)        0.1
- 7440-43-9

NICKEL HYDROXIDE - 12054-48-7        0.1

SARA 311/312 HAZARD CATEGORIES: DOES NOT APPLY

CWA (CLEAN WATER ACT):
THIS PRODUCT CONTAINS THE FOLLOWING SUBSTANCES WHICH ARE REGULATED
POLLUTANTS PURSUANT TO THE CLEAN WATER ACT (40 CFR 122.21 AND 40 CFR
122.42)

CHEMICAL NAME  CWA - REPORTABLE   CWA - TOXIC  CWA - PRIORITY  CWA -
               QUANTITIES         POLLUTANTS   POLLUTANTS      HAZARDOUS
                                                               SUBSTANCES

NICKEL                            X            X
7440-02-0

CADMIUM AND                       X            X
COMPOUNDS
(AS Cd)
7440-43-9

CADMIUM                           X
HYDROXIDE
(Cd(OH)2)
21041-95-2

NICKEL                            X                            X
HYDROXIDE
12054-48-7

CERCLA:
THIS MATERIAL, AS SUPPLIED, CONTAINS ONE OR MORE SUBSTANCES REGULATED AS A
HAZARDOUS SUBSTANCE UNDER THE COMPREHENSIVE ENVIRONMENTAL RESPONSE
COMPENSATION AND LIABILITY ACT (CERCLA) (40 CFR 302)

CHEMICAL NAME  HAZARDOUS SUBSTANCES  CERCLA/SARA RQ   REPORTABLE QUANTITY
               RQS                                    (RQ)

NICKEL         100 LB                                 RQ: 100 LB FINAL RQ
7440-02-0                                             RQ: 45.4 KG FINAL RQ

CADMIUM AND    10 LB                                  RQ: 10 LB FINAL RQ
COMPOUNDS                                             RQ: 4.54 KG FINAL RQ
(AS Cd)
7440-43-9

NICKEL         10 LB                                  RQ: 10 LB FINAL RQ
HYDROXIDE                                             RQ: 4.54 KG FINAL RQ
12054-48-7

US STATE REGULATIONS:

CALIFORNIA PROPOSITION 65:
THIS PRODUCT CONTAINS THE FOLLOWING PROPOSITION 65 CHEMICALS

CHEMICAL NAME                            CALIFORNIA PROPOSITION 65

NICKEL - 7440-02-0                       CARCINOGEN

CADMIUM AND COMPOUNDS (AS Cd) -          CARCINOGEN
7440-43-9                                DEVELOPMENTAL
                                         MALE REPRODUCTIVE

CADMIUM HYDROXIDE (Cd(OH)2) -            CARCINOGEN
21041-95-2

NICKEL HYDROXIDE - 12054-48-7            CARCINOGEN

U.S. STATE RIGHT-TO-KNOW REGULATIONS:
THIS PRODUCT MAY CONTAIN SUBSTANCES REGULATED BY STATE RIGHT-TO-KNOW
REGULATIONS

CHEMICAL NAME         NEW JERSEY      MASSACHUSETTS       PENNSYLVANIA

NICKEL                X               X                   X
7440-02-0

CADMIUM AND           X               X                   X
COMPOUNDS (AS Cd)
7440-43-9

NICKEL HYDROXIDE      X               X                   X
12054-48-7


16. OTHER INFORMATION 


REVISION NOTE:

ISSUE DATE: 21-JAN-2015

REVISION DATE: 21-JAN-2015

REVISION NOTE: NOT APPLICABLE

KEY OR LEGEND TO ABBREVIATIONS AND ACRONYMS USED IN THE SAFETY DATA SHEET:

TWA: TWA (TIME-WEIGHTED AVERAGE)

STEL: STEL (SHORT TERM EXPOSURE LIMIT)

CEILING: MAXIMUM LIMIT VALUE

TSCA: UNITED STATES TOXIC SUBSTANCES CONTROL ACT SECTION 8(B) INVENTORY

DSL/NDSL: CANADIAN DOMESTIC SUBSTANCES LIST/NON-DOMESTIC SUBSTANCES LIST

EINECS/ELINCS:
EUROPEAN INVENTORY OF EXISTING CHEMICAL SUBSTANCES/EUROPEAN LIST OF
NOTIFIED CHEMICAL SUBSTANCES

ENCS: JAPAN EXISTING AND NEW CHEMICAL SUBSTANCES

IECSC: CHINA INVENTORY OF EXISTING CHEMICAL SUBSTANCES

KECL: KOREAN EXISTING AND EVALUATED CHEMICAL SUBSTANCES

PICCS: PHILIPPINES INVENTORY OF CHEMICALS AND CHEMICAL SUBSTANCES

AICS: AUSTRALIAN INVENTORY OF CHEMICAL SUBSTANCES

DISCLAIMER:
THE INFORMATION PROVIDED IN THIS MATERIAL SAFETY DATA SHEET IS CORRECT TO
THE BEST OF OUR KNOWLEDGE, INFORMATION AND BELIEF AT THE DATE OF ITS
PUBLICATION. THE INFORMATION GIVEN IS DESIGNED ONLY AS A GUIDANCE FOR SAFE
HANDLING, USE, PROCESSING, STORAGE, TRANSPORTATION, DISPOSAL AND RELEASE
AND IS NOT TO BE CONSIDERED A WARRANTY OR QUALITY SPECIFICATION. THE
INFORMATION RELATES ONLY TO THE SPECIFIC MATERIAL DESIGNATED AND MAY NOT BE
VALID FOR SUCH MATERIAL USED IN COMBINATION WITH ANY OTHER MATERIALS OR IN
ANY PROCESS, UNLESS SPECIFIED IN THE TEXT.

CENTRE TESTING INTERNATIONAL CORPORATION

BUILD C. HONGWEL INDUSTRIAL ZONE
BAOAN 70 DISTRICT, SHENZHEN
CHINA

WWW.CTI-CERT.COM

E-MAIL: INFO@CTI-CERT.COM

HOTLINE: 400-6788-333