Common Name: GER6M,GER03M, SUPER HEAVY DUTY CARBON BATTERY
Manufacturer: GOLDEN POWER HONG KONG
SDS Revision Date: 1/3/2017
SDS Format: ANSI-OSHA
   
Item Number(s): 328YL1, 328YL2, 55NP06, 55NP08, 55NP09, 56HN59, 56HN60, 56HN61, 56HN62, 56HN63, 56HN64, 56HN65, 56HN66, 56HN67, 56HN68, 794CF0
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION I - IDENTIFICATION OF THE SUBSTANCE/PREPARATION 
SECTION II - COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION III - PHYSICAL AND CHEMICAL PROPERTIES 
SECTION IV - FIRE-FIGHTING MEASURES 
SECTION V - STABILITY AND REACTIVITY 
SECTION VI - TOXICOLOGICAL INFORMATION 
SECTION VII - ECOLOGICAL INFORMATION 
SECTION VIII - FIRST-AID MEASURES 
SECTION IX - ACCIDENTAL RELEASE MEASURES 
SECTION X - DISPOSAL CONSIDERATIONS 
SECTION XI - HANDLING AND STORAGE 
SECTION XII - HAZARDS IDENTIFICATION 
SECTION XIII - EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION XIV - REGULATORY INFORMATION 
SECTION XV - OTHER INFORMATION 
SECTION XVI - TRANSPORTATION INFORMATION 



GOLDEN POWER(R*)

GOLDEN POWER CORPORATION (HK) LTD.

SAFETY DATA SHEET SDS

REF.NO.: GPSDS-CARBON-2017A

IDENTITY (AS READ ON LABEL AND LINE):
GER6M, GER03M SUPER HEAVY DUTY CARBON BATTERY

NOTICE:
BLANK SPACES ARE NOT PERMITTED. IF ANY ITEM IS NOT APPLICABLE, OR NO
INFORMATION IS AVAILABLE, THE SPACE MUST BE MARKED TO INDICATE THAT.


SECTION I - IDENTIFICATION OF THE SUBSTANCE/PREPARATION 

                       AND OF THE COMPANY/UNDERTAKING

MANUFACTURER'S NAME: GOLDEN POWER CORPORATION (HK) LTD.

ADDRESS (NUMBER, SHEET, CITY, STATE, AND ZIP CODE):
FLAT C, 20/F., BLOCK 1, TAI PING INDUSTRIAL CENTRE
57 TING KOK ROAD, TAI PO, N.T.
HONG KONG

TELEPHONE NUMBER: (852) 3125 2288

FAX NUMBER: (852) 3125 2000 / 3125 2001

DATE PREPARED: 3 JANUARY 2017

SIGNATURE OF PREPARER (OPTIONAL):


SECTION II - COMPOSITION/INFORMATION ON INGREDIENTS 


HAZARDOUS COMPONENTS       (CONTENTS, %/WT)  CAS NO.
(SPECIFIC CHEMICAL
IDENTITY, COMMON NAMES)

MANGANESE DIOXIDE (MnO2)   21.45%             1313-13-9

ZINC (Zn)                  21.63%             7440-66-6

ZINE CHLORIDE (ZnCL2)       6.16%             7646-85-7

AMMONIUM CHLORIDE (NH4CL)   0.22%            12125-02-9

GRAPHITE (C)               10.46%             7782-42-5

WATER (H2O)                14.86%             7732-18-5

FERRUM (Fe)                20.42%             8053-60-9

POLYETHYLENE (Pe)           1.76%               74-85-1

POLYVINYL CHLORIDE (PVC)    1.20%            93050-82-9

OTHER                       1.84%

EU BATTERY DIRECTIVE 2006-66-EC(2013-56-EU) & US104-142

MERCURY (Hg)              <0.0001%            7439-97-6

LEAD (Pb)                 <0.0010%            7439-92-1

CADMIUM (Cd)              <0.0005%            7440-43-9


SECTION III - PHYSICAL AND CHEMICAL PROPERTIES 


BOILING POINT: KOH AQUA SOLUTION = 140 DEG. C

SPECIFIC GRAVITY (H2O=1): MnO2 = 4.4, Zn = 7.1, KOH = 2.0

VAPOR PRESSURE (MMHg): KOH AQUA SOLUTION = 3MMHg AT 20 DEG. C

MELTING POINT:
MnO2 DECOMPOSE AT 535 DEG. C
Zn = 420 DEG. C, KOH AQUA = -35 DEG. C

VAPOR DENSITY (AIR = 1):

EVAPORATION RATE (BUTYL ACETATE = 1):

SOLUBILITY IN WATER: KOH - COMPLETE

APPEARANCE AND COLOR:

MnO2 IS A BLACK POWDER, GRAPHITE IS ALSO A BLACK POWDER, ZINC IS A SILVER
METAL.

KOH AQUA IS A COLORLESS LIQUID WITH STIMULATIVE ORDER.


SECTION IV - FIRE-FIGHTING MEASURES 


FLASH POINT (METHOD USED): INCOMBUSTIBLE

FLAMMABLE LIMITS: NOT AVAILABLE

LEL:
UEL:

EXTINGUISHING MEDIA: SEE SPECIAL FIRE FIGHTING PROCEDURE

SPECIAL FIRE FIGHTING PROCEDURE:
IN CASE OF FIRE IN AN ADJACENT AREA, USE WATER, CO2 OR DRY CHEMICAL
EXTINGUISHERS IF CELLS ARE PACKED IN THEIR ORIGINAL CONTAINERS SINCE
THE FUEL OF THE FIRE IS BASICALLY PAPER PRODUCTS. FOR BULK QUANTITIES
OF UNPACKAGED CELLS USE LITH-X (GRAPHITE BASE). IN THIS CASE, DO NOT
USE WATER.

AS WITH ANY FIRE, WEAR SELF-CONTAINED BREATHING APPARATUS TO AVOID
INHALATION OF HAZARDOUS DECOMPOSITION PRODUCTS.

UNUSUAL FIRE AND EXPLOSION HAZARDS


SECTION V - STABILITY AND REACTIVITY 


STABILITY:
UNSTABLE ( )
STABLE   (X)

CONDITIONS TO AVOID: DO NOT SHORT CIRCUIT, CHARGE OR DISPOSE OF IN FIRE.

INCOMPATIBILITY (MATERIALS TO AVOID):
HAZARDOUS POLYMERIZATION WILL NOT OCCUR.

HAZARDOUS DECOMPOSITION OR BYPRODUCTS: NOT AVAILABLE

HAZARDOUS POLYMERIZATION:
MAY OCCUR      ( )
WILL NOT OCCUR (X)

CONDITIONS TO AVOID:


SECTION VI - TOXICOLOGICAL INFORMATION 


ROUTE(S) OF ENTRY.:
INHALATION?: YES
SKIN?: YES
INGESTION?: YES

HEALTH HAZARDS (ACUTE AND CHRONIC):
THESE CHEMICALS ARE CONTAINED IN A SEALED CAN. RISK OF EXPOSURE OCCURS,
ONLY IF BATTERY IS MECHANICALLY OR ELECTRICALLY ABUSED. THE MOST LIKELY
RISK IS ACUTE EXPOSURE WHEN A CELL VENTS KOH IS CAUSTIC ALKALI AND ATTACK
THE SKIN AND EYES. CONTACT OF ELECTROLYTE WITH SKIN AND EYES SHOULD BE
AVOIDED.


SECTION VII - ECOLOGICAL INFORMATION 


CARCINOGENICITY:
NTP?: NOT AVAILABLE
IARC MONOGRAPHS?: NOT AVAILABLE
OSHA REGULATED?: NOT AVAILABLE

SIGNS AND SYMPTOMS OF EXPOSURE:
KOH CAN CAUSE CHEMICAL BURN UPON CONTACT WITH SKIN.

MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE:
AN ACUTE EXPOSURE WILL NOT GENERALLY AGGRAVATE ANY MEDICAL HELP.


SECTION VIII - FIRST-AID MEASURES 


IN CASE OF SKIN CONTACT WITH CONTENT OF BATTERY, FLUSH IMMEDIATELY WITH
WATER.

FOR EYE CONTACT, FLUSH WITH COPIOUS AMOUNT OF WATER FOR 10 MINUTES. IF
IMITATION PERSISTS, GET MEDICAL HELP.


SECTION IX - ACCIDENTAL RELEASE MEASURES 


STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED WIPE OUT BY WET
DUSTER.


SECTION X - DISPOSAL CONSIDERATIONS 


GENERAL ABANDONMENT


SECTION XI - HANDLING AND STORAGE 


AVOID MECHANICAL OR ELECTRICAL ABUSE.


SECTION XII - HAZARDS IDENTIFICATION 


DO NOT SHORT CIRCUIT, CHARGE OR DISPOSE OF IN FIRE. BATTERY MAY EXPLODE OR
LEAK.


SECTION XIII - EXPOSURE CONTROLS/PERSONAL PROTECTION 


RESPIRATORY PROTECTION (SPECIFY TYPE): NOT AVAILABLE

VENTILATION:
LOCAL EXHAUST: NOT AVAILABLE
MECHANICAL (GENERAL): NOT AVAILABLE
SPECIAL: NOT AVAILABLE
OTHER: NOT AVAILABLE

PROTECTIVE GLOVES: BUTYL

EYE PROTECTION: SAFETY GLASSES

OTHER PROTECTIVE CLOTHING OR EQUIPMENT: NOT AVAILABLE

WORK / HYGIENIC PRACTICES: NOT AVAILABLE


SECTION XIV - REGULATORY INFORMATION 


NOT AVAILABLE


SECTION XV - OTHER INFORMATION 


NOT AVAILABLE


SECTION XVI - TRANSPORTATION INFORMATION 


GOLDEN POWER "SUPER HEAVY DUTY CARBON BATTERY" ARE CONSIDERED TO BE
"DRY CELL" BATTERIES AND ARE NOT LISTED AS DANGEROUS GOODS UNDER BELOW
REGULATIONS:

1. BATTERIES, DRY FULFILLS THE REQUIREMENT OF U.S. DEPARTMENT OF
TRANSPORTATION (DOT), SPECIAL PROVISION 130, I.E. THEY ARE OFFERED FOR
TRANSPORTATION IN A MANNER THAT PREVENTS THE DANGEROUS EVOLUTION OF HEAT
(FOR EXAMPLE, BY THE EFFECTIVE INSULATION OF EXPOSED TERMINALS OR BATTERIES
TO BE PACKED IN SUCH A WAY TO PREVENT SHORT CIRCUITS OR GENERATION OF A
DANGEROUS QUANTITY OF HEAT.)".

2. INTERNATIONAL CIVIL AVIATION ADMINISTRATION (ICAO) AND INTERNATIONAL AIR
TRANSPORT ASSOCIATION (IATA DANGEROUS GOODS REGULATION 58# EDITION 2017),
SPECIAL PROVISION A123, I.E. "AN ELECTRICAL BATTERY OR BATTERY POWERED
DEVICE HAVING THE POTENTIAL OF DANGEROUS EVOLUTIONS OF HEAT THAT IS NOT
PREPARED SO AS TO PREVENT A SHORT-CIRCUIT (E.G. IN THE CASE OF BATTERIES,
BY THE EFFECTIVE INSULATION OF EXPOSED TERMINALS; OR IN THE CASE OF
EQUIPMENT, BY DISCONNECTION OF THE BATTERY AND PROTECTION OF EXPOSED
TERMINALS OR BATTERIES TO BE PACKED IN SUCH A WAY TO PREVENT SHORT CIRCUITS
OR GENERATION OF A DANGEROUS QUANTITY OF HEAT.) IS FORBIDDEN FROM
TRANSPORTATION."

3. INTERNATIONAL MARITIME DANGEROUS GOODS REGULATIONS (IMDG)2014 EDITION
DOES NOT REGULATE THESE BATTERIES.

EXAMPLES OF SUCH BATTERIES INCLUDE ALKALI-MANGANESE, SILVER OXIDE, ZINC
CARBON, NICKEL METAL HYDRIDE AND NICKEL-CADMIUM BATTERIES.