Common Name: NON-FLAMMABLE GAS MIXTURE, 50120MSA
Manufacturer: AIR LIQUIDE
SDS Revision Date: 10/17/2014
SDS Format: No Format Specified
   
Item Number(s): 33RJ57
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1 - IDENTIFICATION OF THE SUBSTANCE/MIXTURE 
SECTION 2 - HAZARDS IDENTIFICATION 
SECTION 3 - COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION 4 - FIRST AID MEASURES 
SECTION 5 - FIREFIGHTING MEASURES 
SECTION 6 - ACCIDENTAL RELEASE MEASURES 
SECTION 7 - HANDLING AND STORAGE 
SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10 - STABILITY AND REACTIVITY 
SECTION 11 - TOXICOLOGICAL INFORMATION 
SECTION 12 - ECOLOGICAL INFORMATION 
SECTION 13 - DISPOSAL CONSIDERATIONS 
SECTION 14 - TRANSPORT INFORMATION 
SECTION 15 - REGULATORY INFORMATION 
SECTION 16 - OTHER INFORMATION 



NON-FLAMMABLE GAS MIXTURE CONTAINING SULFUR DIOXIDE 0.0001%, HYDROGEN
SULFIDE 0.001-0.025%, PENTANE 0.0-0.75%, OXYGEN 0.0-23.5% IN NITROGEN
BALANCE

MSA

THE SAFETY COMPANY

SAFETY DATA SHEET

50120MSA


SECTION 1 - IDENTIFICATION OF THE SUBSTANCE/MIXTURE 

                         AND OF THE COMPANY/UNDERTAKING

1.1 PRODUCT IDENTIFIER:

PRODUCT NAME:
NON-FLAMMABLE GAS MIXTURE CONTAINING SULFUR DIOXIDE 0.0001%, HYDROGEN
SULFIDE 0.001-0.025%, PENTANE 0.0-0.75%, OXYGEN 0.0-23.5% IN NITROGEN
BALANCE

MSA P/N: 10153806, 10153807, 10153808, 10154996

1.2 RELEVANT IDENTIFIED USES OF THE SUBSTANCE OR MIXTURE AND USES ADVISED
AGAINST:

RELEVANT IDENTIFIED USE(S):
CALIBRATION OF MONITORING AND RESEARCH EQUIPMENT

1.3 DETAILS OF THE SUPPLIER OF THE SAFETY DATA SHEET:

MANUFACTURER:
AIR LIQUIDE
2700 POST OAK BLVD.
HOUSTON, TX 77056
UNITED STATES

WWW.US.AIRLIQUIDE.COM

SDS@AIRLIQUIDE.COM

U.S. SUPPLIER:
MINE SAFETY APPLIANCES COMPANY
100 CRANBERRY WOODS DRIVE
CRANBERRY TOWNSHIP
PENNSYLVANIA U.S.A. 16066
1-800-MSA-2222

WWW.MSANET.COM/PRISM

TELEPHONE (TECHNICAL): 713-896-2896
TELEPHONE (TECHNICAL): 800-819-1704

1.4 EMERGENCY TELEPHONE NUMBER:
MANUFACTURER: 800-424-9300 - CHEMTREC
MANUFACTURER: +1 703-527-3887 - OUTSIDE UNITED STATES


SECTION 2 - HAZARDS IDENTIFICATION 


EU/EEC:
ACCORDING TO REGULATION (EC) NO 1272/2008 (CLP)/REACH 1907/2006 [AMENDED BY
453/2010] ACCORDING TO EU DIRECTIVE 67/548/EEC (DSD) OR 1999/45/EC (DPD):

2.1 CLASSIFICATION OF THE SUBSTANCE OR MIXTURE:
CLP: COMPRESSED GAS - H280
DSD/DPD: NOT CLASSIFIED

2.2 LABEL ELEMENTS:

CLP: WARNING

GAS CYLINDER

HAZARD STATEMENTS:
H280: CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED

PRECAUTIONARY STATEMENTS:

STORAGE/DISPOSAL:
P403: STORE IN A WELL-VENTILATED PLACE.

DSD/DPD:
RISK PHRASES: NO LABEL ELEMENT(S) REQUIRED

2.3 OTHER HAZARDS:

CLP:
THIS MATERIAL IS A SIMPLE ASPHYXIANT. MAY DISPLACE OR REDUCE OXYGEN
AVAILABLE FOR BREATHING ESPECIALLY IN CONFINED SPACES.

ACCORDING TO REGULATION (EC) NO. 1272/2008 (CLP) THIS MATERIAL IS
CONSIDERED HAZARDOUS.

DSD/DPD:
THIS MATERIAL IS A SIMPLE ASPHYXIANT. MAY DISPLACE OR REDUCE OXYGEN
AVAILABLE FOR BREATHING ESPECIALLY IN CONFINED SPACES.

ACCORDING TO EUROPEAN DIRECTIVE 1999/45/EC THIS PREPARATION IS NOT
CONSIDERED DANGEROUS.

UNITED STATES (US):

ACCORDING TO OSHA 29 CFR 1910.1200 HCS:

2.1 CLASSIFICATION OF THE SUBSTANCE OR MIXTURE:

OSHA HCS 2012:
COMPRESSED GAS -H280
SIMPLE ASPHYXIANT

2.2 LABEL ELEMENTS:

OSHA HCS 2012: WARNING

GAS CYLINDER

HAZARD STATEMENTS:
CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED - H280 MAY DISPLACE
OXYGEN AND CAUSE RAPID SUFFOCATION.

PRECAUTIONARY STATEMENTS:
STORAGE/DISPOSAL: STORE IN A WELL-VENTILATED PLACE. - P403

2.3 OTHER HAZARDS:

OSHA HCS 2012:
UNDER UNITED STATES REGULATIONS (29 CFR 1910.1200 - HAZARD COMMUNICATION
STANDARD), THIS PRODUCT IS CONSIDERED HAZARDOUS.

CANADA:

ACCORDING TO WHMIS:

2.1 CLASSIFICATION OF THE SUBSTANCE OR MIXTURE:
WHMIS: COMPRESSED GAS - A

2.2 LABEL ELEMENTS:
WHMIS: COMPRESSED GAS - A

2.3 OTHER HAZARDS:

WHMIS:
THIS MATERIAL IS A SIMPLE ASPHYXIANT. MAY DISPLACE OR REDUCE OXYGEN
AVAILABLE FOR BREATHING ESPECIALLY IN CONFINED SPACES.

IN CANADA, THE PRODUCT MENTIONED ABOVE IS CONSIDERED HAZARDOUS UNDER THE
WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS).


SECTION 3 - COMPOSITION/INFORMATION ON INGREDIENTS 


3.1 SUBSTANCES:
MATERIAL DOES NOT MEET THE CRITERIA OF A SUBSTANCE IN ACCORDANCE WITH
REGULATION (EC) NO 1272/2008.

3.2 MIXTURES:

COMPOSITION:

CHEMICAL NAME          IDENTIFIERS                    %

OXYGEN                 CAS: 7782-44-7                 0% TO 23.5%
                       EC NUMBER: 231-956-9
                       EU INDEX: 008-001-00-8

PENTANE                CAS: 109-66-0                  0% TO 0.75
                       EC NUMBER: 203-692-4
                       EU INDEX: 601-006-00-1

HYDROGEN SULFIDE       CAS: 7783-06-4                 0.001% TO 0.025%
                       EC NUMBER: 231-977-3
                       EU INDEX: 016-001-00-4

SULFUR DIOXIDE         CAS: 7446-09-5                 0.0001%
                       EC NUMBER: 231-195-2
                       EU INDEX: 016-011-00-9

NITROGEN               CAS: 7727-37-9                 BALANCE
                       EINECS: 231-783-9


CHEMICAL              LD50/LC50      CLASSIFICATIONS ACCORDING
NAME                                 TO REGULATION/DIRECTIVE

OXYGEN                NDA            EU DSD/DPD: ANNEX VI, TABLE 3.2: O R8

                                     EU CLP:
                                     ANNEX VI, TABLE 3.1:
                                     OX. GAS 1, H270; PRESS. GAS - COMP.,
                                     H280

                                     OSHA HCS 2012:
                                     OX. GAS 1; PRESS. GAS - COMP.

PENTANE               INHALATION-    EU DSD/DPD:
                      RAT LC50:      ANNEX VI, TABLE 3.2:
                      364 G/M3       F+ R12 N R51-53 XN R65 R66 R67
                      4 HOUR(S)
                                     EU CLP:
                      INGESTION/     ANNEX VI, TABLE 3.1:
                      ORAL-RAT       FLAM. LIQ. 1, H224; ASP. TOX. 1, H304;
                      LD50:
                      >2000 MG/KG    STOT SE 3:
                                     NARC., H336; AQUATIC CHRONIC 2, H411;
                                     EUH066

                                     OSHA HCS 2012:
                                     FLAM. LIQ. 1; ASP TOX. 1; EYE IRRIT.
                                     2A; SKIN IRRIT. 2

                                     STOT SE 3: NARC.

HYDROGEN SULFIDE      INHALATION-    EU DSD/DPD:
                      RAT LC50:      ANNEX VI, TABLE 3.2:
                      700 MG/M3      F+ R12 T+ R26 N R50
                      4 HOUR(S)
                                     EU CLP:
                                     ANNEX VI, TABLE 3.1:
                                     FLAM. GAS 1, H220; PRESS. GAS - COMP.,
                                     H280

                                     ACUTE TOX. 2 *H330:
                                     AQUATIC ACUTE 1, H400

                                     OSHA HCS 2012:
                                     FLAM. GAS; PRESS. GAS - COMP.; ACUTE
                                     TOX. 2 (INHL)

SULFUR DIOXIDE        INHALATION-    EU DSD/DPD:
                      RAT LC50:      ANNEX VI, TABLE 3.2: T R23 C R34
                      2168 MG/M3
                                     EU CLP:
                                     ANNEX VI, TABLE 3.1:
                                     PRESS. GAS - COMP., H280; ACUTE TOX.
                                     3*, H331; SKIN CORR. 1B, H314

                                     OSHA HCS 2012:
                                     PRESS. GAS - COMP.; MUTA. 2; ACUTE
                                     TOX. 3 (INHL); REPR. 2; SKIN CORR. 1B;
                                     EYE DAM. 1

NITROGEN              NDA            EU DSD/DPD: NOT CLASSIFIED

                                     EU CLP:
                                     SELF CLASSIFIED:
                                     PRESS. GAS - COMP. H280

                                     OSHA HCS 2012:
                                     PRESS. GAS - COMP.; SIMP. ASPHYX.

SEE SECTION 16 FOR FULL TEXT OF H-STATEMENTS AND R-PHRASES.


SECTION 4 - FIRST AID MEASURES 


4.1 DESCRIPTION OF FIRST AID MEASURES:

INHALATION:

IF INHALED:
REMOVE VICTIM TO FRESH AIR AND KEEP AT REST IN A POSITION COMFORTABLE FOR
BREATHING. ADMINISTER OXYGEN IF BREATHING IS DIFFICULT. GIVE ARTIFICIAL
RESPIRATION IF VICTIM IS NOT BREATHING. IF SIGNS/SYMPTOMS CONTINUE, GET
MEDICAL ATTENTION.

SKIN:
ALTHOUGH EXPOSURE IS UNLIKELY, IN CASE OF CONTACT IMMEDIATELY FLUSH SKIN
WITH RUNNING WATER. IF SKIN IRRITATION DEVELOPS GET MEDICAL
ADVICE/ATTENTION.

EYE:
FIRST AID IS NOT EXPECTED TO BE NECESSARY IF MATERIAL IS USED UNDER
ORDINARY CONDITIONS AND AS RECOMMENDED. IF IRRITATION DEVELOPS AND
PERSISTS, GET MEDICAL ATTENTION. INGESTION. INGESTION IS NOT CONSIDERED A
POTENTIAL ROUTE OF EXPOSURE.

4.2 MOST IMPORTANT SYMPTOMS AND EFFECTS, BOTH ACUTE AND DELAYED:
REFER TO SECTION 11 - TOXICOLOGICAL INFORMATION.

4.3 INDICATION OF ANY IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT
NEEDED:

NOTES TO PHYSICIAN:
ALL TREATMENTS SHOULD BE BASED ON OBSERVED SIGNS AND SYMPTOMS OF DISTRESS
IN THE PATIENT. CONSIDERATION SHOULD BE GIVEN TO THE POSSIBILITY THAT
OVEREXPOSURE TO MATERIALS OTHER THAN THIS PRODUCT MAY HAVE OCCURRED. A
POTENTIAL HEALTH HAZARD ASSOCIATED WITH THIS GAS IS ANOXIA.

4.4 OTHER INFORMATION:
ENSURE THAT MEDICAL PERSONNEL ARE AWARE OF THE MATERIAL(S) INVOLVED AND
TAKE PRECAUTIONS TO PROTECT THEMSELVES. RESCUERS SHOULD NOT ATTEMPT TO
RETRIEVE VICTIMS OF EXPOSURE TO GASES WITHOUT ADEQUATE PERSONAL PROTECTIVE
EQUIPMENT. AT A MINIMUM, SELF-CONTAINED BREATHING APPARATUS MUST BE WORN.
VICTIM(S) WHO EXPERIENCE ANY ADVERSE EFFECT AFTER OVEREXPOSURE TO THIS GAS
MIXTURE MUST BE TAKEN FOR MEDICAL ATTENTION. RESCUERS SHOULD BE TAKEN FOR
MEDICAL ATTENTION IF NECESSARY. TAKE A COPY OF THE LABEL AND THE MSDS TO
PHYSICIAN OR OTHER HEALTH PROFESSIONAL WITH VICTIM(S).


SECTION 5 - FIREFIGHTING MEASURES 


5.1 EXTINGUISHING MEDIA:

SUITABLE EXTINGUISHING MEDIA:
USE EXTINGUISHING AGENT SUITABLE FOR TYPE OF SURROUNDING FIRE.

UNSUITABLE EXTINGUISHING MEDIA: NO DATA AVAILABLE

5.2 SPECIAL HAZARDS ARISING FROM THE SUBSTANCE OR MIXTURE:

UNUSUAL FIRE AND EXPLOSION HAZARDS:
CONTAINERS MAY EXPLODE WHEN HEATED.
RUPTURED CYLINDERS MAY ROCKET.

HAZARDOUS COMBUSTION PRODUCTS: NO DATA AVAILABLE

5.3 ADVICE FOR FIREFIGHTERS:
STRUCTURAL FIREFIGHTERS' PROTECTIVE CLOTHING PROVIDES LIMITED PROTECTION IN
FIRE SITUATIONS ONLY; IT IS NOT EFFECTIVE IN SPILL SITUATIONS WHERE DIRECT
CONTACT WITH THE SUBSTANCE IS POSSIBLE.

WEAR POSITIVE PRESSURE SELF-CONTAINED BREATHING APPARATUS (SCBA).

MOVE CONTAINERS FROM FIRE AREA IF YOU CAN DO IT WITHOUT RISK.

FIRE:
IF TANK, RAIL CAR OR TANK TRUCK IS INVOLVED IN A FIRE, ISOLATE FOR 800
METERS (1/2 MILE) IN ALL DIRECTIONS; ALSO, CONSIDER INITIAL EVACUATION FOR
800 METERS (1/2 MILE) IN ALL DIRECTIONS.

FIRE INVOLVING TANKS:
FIGHT FIRE FROM MAXIMUM DISTANCE OR USE UNMANNED HOSE HOLDERS OR MONITOR
NOZZLES.

FIRE INVOLVING TANKS:
COOL CONTAINERS WITH FLOODING QUANTITIES OF WATER UNTIL WELL AFTER FIRE IS
OUT.

FIRE INVOLVING TANKS:
DO NOT DIRECT WATER AT SOURCE OF LEAK OR SAFETY DEVICES; ICING MAY OCCUR.

FIRE INVOLVING TANKS:
WITHDRAW IMMEDIATELY IN CASE OF RISING SOUND FROM VENTING SAFETY DEVICES OR
DISCOLORATION OF TANK.

FIRE INVOLVING TANKS: ALWAYS STAY AWAY FROM TANKS ENGULFED IN FIRE.


SECTION 6 - ACCIDENTAL RELEASE MEASURES 


6.1 PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:

PERSONAL PRECAUTIONS:
VENTILATE THE AREA BEFORE ENTRY. DO NOT WALK THROUGH SPILLED MATERIAL.
DO NOT TOUCH DAMAGED CONTAINERS OR SPILLED MATERIAL UNLESS WEARING
APPROPRIATE PROTECTIVE CLOTHING.

EMERGENCY PROCEDURES:
KEEP UNAUTHORIZED PERSONNEL AWAY. KEEP OUT OF LOW AREAS. STAY UPWIND.
DO NOT DIRECT WATER AT SPILL OR SOURCE OF LEAK.

LARGE SPILL:
CONSIDER INITIAL DOWNWIND EVACUATION FOR AT LEAST 500 METERS (1/3 MILE)

6.2 ENVIRONMENTAL PRECAUTIONS:
PREVENT SPREADING OF VAPORS THROUGH SEWERS, VENTILATION SYSTEMS AND
CONFINED AREAS.

6.3 METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP:

CONTAINMENT/CLEAN-UP MEASURES:
STOP LEAK IF YOU CAN DO IT WITHOUT RISK.

VENTILATE THE AREA.

ISOLATE AREA UNTIL GAS HAS DISPERSED.

USE WATER SPRAY TO REDUCE VAPORS; DO NOT PUT WATER DIRECTLY ON LEAK, SPILL
AREA OR INSIDE CONTAINER.

IF POSSIBLE, TURN LEAKING CONTAINERS SO THAT GAS ESCAPES RATHER THAN
LIQUID.

6.4 REFERENCE TO OTHER SECTIONS:
REFER TO SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION AND
SECTION 13 - DISPOSAL CONSIDERATIONS.


SECTION 7 - HANDLING AND STORAGE 


7.1 PRECAUTIONS FOR SAFE HANDLING:

HANDLING:
USE ONLY WITH ADEQUATE VENTILATION. VENTILATE CLOSED SPACES BEFORE
ENTERING. BE AWARE OF ANY SIGNS OF DIZZINESS OR FATIGUE, ESPECIALLY IF WORK
IS DONE IN A POORLY VENTILATED AREA; EXPOSURES TO FATAL CONCENTRATIONS OF
THIS GAS MIXTURE COULD OCCUR WITHOUT ANY SIGNIFICANT WARNING SYMPTOMS, DUE
TO OLFACTORY FATIGUE OR OXYGEN DEFICIENCY. CYLINDERS SHOULD BE FIRMLY
SECURED TO PREVENT FALLING OR BEING KNOCKED-OVER. DO NOT ATTEMPT TO REPAIR,
ADJUST, OR IN ANY OTHER WAY MODIFY CYLINDERS. IF THERE IS A MALFUNCTION OR
ANOTHER TYPE OF OPERATIONAL PROBLEM, CONTACT NEAREST DISTRIBUTOR
IMMEDIATELY. EMPTY CONTAINERS RETAIN PRODUCT RESIDUE AND CAN BE HAZARDOUS.
DO NOT CUT, WELD, PUNCTURE OR INCINERATE CONTAINER.

7.2 CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES:

STORAGE:
STORE IN A COOL, DRY, WELL-VENTILATED PLACE. PROTECT CYLINDERS AGAINST
PHYSICAL DAMAGE. CYLINDERS SHOULD BE FIRMLY SECURED TO PREVENT FALLING OR
BEING KNOCKED-OVER. DO NOT ALLOW AREA WHERE CYLINDERS ARE STORED TO EXCEED
52C (125F).

7.3 SPECIFIC END USE(S): REFER TO SECTION 1.2 - RELEVANT IDENTIFIED USES.


SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION 


8.1 CONTROL PARAMETERS:

EXPOSURE LIMITS/GUIDELINES:

              RESULT    ACGIH              CANADA ONTARIO   CANADA QUEBEC

PENTANE       STELS     NOT ESTABLISHED    NOT ESTABLISHED  NOT ESTABLISHED
(109-66-0)

              TWAS      600 PPM TWA        600 PPM TWA      120 PPM TWAEV
                        (LISTED UNDER                       350 MG/M3 TWAEV
                        PENTANE, ALL
                        ISOMERS)

SULFUR        STELS     0.25 PPM STEL      5 PPM STEL       5 PPM STEV
DIOXIDE                                    10.4 MG/M3 STEL  13 MG/M3 STEV
(7446-09-5)

              TWAS      NOT ESTABLISHED    2 PPM TWA        2 PPM TWAEV
                                           5.2 MG/M3 TWA    5.2 MG/M3 TWAEV

HYDROGEN      CEILINGS  NOT ESTABLISHED    NOT ESTABLISHED  NOT ESTABLISHED
SULFIDE
(7783-06-4)   STELS     5 PPM STEL         15 PPM STEL      15 PPM STEV
                                                            21 MG/M3 STEV

              TWAS      1 PPM TWA          10 PPM TWA       10 PPM TWAEV
                                                            14 MG/M3 TWAEV


              RESULT      CHINA                    CHINA HIGHLY TOXIC GOODS

PENTANE       STELS       1000 MG/M3 STEL          NOT ESTABLISHED
                          (LISTED UNDER PENTANE
                          (ALL ISOMERS))

              TWAS        500 MG/M3 TWA            NOT ESTABLISHED
                          (LISTED UNDER PENTANE
                          (ALL ISOMERS))

SULFUR        STELS       10 MG/M3 STEL            NOT ESTABLISHED
DIOXIDE
              TWAS        5 MG/M3 TWA              NOT ESTABLISHED

HYDROGEN      CEILINGS    10 MG/M3 CEILING         10 MG/M3 CEILING
SULFIDE                   [MAC]

              STELS       NOT ESTABLISHED          NOT ESTABLISHED

              TWAS        NOT ESTABLISHED          NOT ESTABLISHED

              RESULT      EUROPE           FRANCE           GERMANY DFG

PENTANE       TWAS        1000 PPM TWA     1000 PPM TWA     NOT ESTABLISHED
(109-66-0)                3000 MG/M3 TWA   [VME]
                                           (RESTRICTIVE
                                           LIMIT)

                                           3000 MG/M3 TWA
                                           [VME]
                                           (RESTRICTIVE
                                           LIMIT)

              STELS       NOT ESTABLISHED  NOT ESTABLISHED  NOT ESTABLISHED

              CEILINGS    NOT ESTABLISHED  NOT ESTABLISHED  2000 PPM PEAK
                                                            (LISTED UNDER
                                                            PENTANE)

                                                            6000 MG/M3 PEAK
                                                            (LISTED UNDER
                                                            PENTANE)

              MAKS        NOT ESTABLISHED  NOT ESTABLISHED  1000 PPM TWA
                                                            MAK

                                                            3000 MG/M3 TWA
                                                            MAK

SULFUR        STELS       NOT ESTABLISHED  5 PPM STEL       NOT ESTABLISHED
DIOXIDE                                    [VLCT]
(7446-09-5)
                                           10 MG/M3 STEL
                                           [VLCT]

SULFUR        TWAS        NOT ESTABLISHED  2 PPM TWA [VME]  NOT ESTABLISHED
DIOXIDE
(7446-09-5)                                5 MG/M3 TWA
                                           [VME]

              CEILINGS    NOT ESTABLISHED  NOT ESTABLISHED  1 PPM PEAK
                                                            (A CEILING
                                                            VALUE 1 ML/M3
                                                            OR 2.7 MG/M3
                                                            MUST NOT BE
                                                            EXCEEDED)

                                                            2.7 MG/M3 PEAK
                                                            (A CEILING
                                                            VALUE 1 ML/M3
                                                            OR 2.7 MG/M3
                                                            MUST NOT BE
                                                            EXCEEDED)

              MAKS        NOT ESTABLISHED  NOT ESTABLISHED  1 PPM TWA MAK

                                                            2.7 MG/M3 TWA
                                                            MAK

HYDROGEN      STELS       NOT ESTABLISHED  10 PPM STEL      NOT ESTABLISHED
SULFIDE                                    [VLCT]
(7783-06-4)
                                           14 MG/M3 STEL
                                           [VLCT]

              TWAS        NOT ESTABLISHED  5 PPM TWA [VME]  NOT ESTABLISHED

                                           7 MG/M3 TWA
                                           [VME]

              CEILINGS    NOT ESTABLISHED  NOT ESTABLISHED  10 PPM PEAK
                                                            14.2 MG/M3 PEAK

              MAKS        NOT ESTABLISHED  NOT ESTABLISHED  5 PPM TWA MAK

                                                            7.1 MG/M3 TWA
                                                            MAK


              RESULT       GERMANY TRGS                     IRELAND

PENTANE       TWAS         1000 PPM TWA AGW (THE RISK       1000 PPM TWA
                           OF DAMAGE TO THE EMBRYO OR       3000 MG/M3 TWA
                           FETUS CAN BE EXCLUDED WHEN
                           AGW AND BGW VALUES ARE
                           OBSERVED, EXPOSURE FACTOR 2)

                           3000 MG/M3 TWA AGW
                           (THE RISK OF DAMAGE TO THE
                           EMBRYO OR FETUS CAN BE
                           EXCLUDED WHEN AGW AND BGW
                           VALUES ARE OBSERVED,
                           EXPOSURE FACTOR 2)

              STELS        NOT ESTABLISHED                  750 PPM STEL
                                                            2250 MG/M3 STEL

              CEILINGS     NOT ESTABLISHED                  NOT ESTABLISHED

              MAKS         NOT ESTABLISHED                  NOT ESTABLISHED

SULFUR        STELS        NOT ESTABLISHED                  1 PPM STEL
DIOXIDE                                                     2.6 MG/M3 STEL

              TWAS         1 PPM TWA AGW (THE RISK OF       0.5 PPM TWA
                           DAMAGE TO THE EMBRYO OR FETUS    1.3 MG/M3 TWA
                           CAN BE EXCLUDED WHEN AGW AND
                           BGW VALUES ARE OBSERVED,
                           EXPOSURE FACTOR 1)

                           2.5 MG/M3 TWA AGW (THE RISK
                           OF DAMAGE TO THE EMBRYO OR
                           FETUS CAN BE EXCLUDED WHEN
                           AGW AND BGW VALUES ARE
                           OBSERVED, EXPOSURE FACTOR 1)

              CEILINGS     NOT ESTABLISHED                  NOT ESTABLISHED

              MAKS         NOT ESTABLISHED                  NOT ESTABLISHED

HYDROGEN      STELS        NOT ESTABLISHED                  10 PPM STEL
SULFIDE                                                     14 MG/M3 STEL

              TWAS         5 PPM TWA AGW (THE RISK OF       5 PPM TWA
                           DAMAGE TO THE EMBRYO OR FETUS    7 MG/M3 TWA
                           CAN BE EXCLUDED WHEN AGW AND
                           BGW VALUES ARE OBSERVED,
                           EXPOSURE FACTOR 2)

                           7.1 MG/M3 TWA AGW (THE RISK
                           OF DAMAGE TO THE EMBRYO OR
                           FETUS CAN BE EXCLUDED WHEN
                           AGW AND BGW VALUES ARE
                           OBSERVED, EXPOSURE FACTOR 2)

              CEILINGS     NOT ESTABLISHED                  NOT ESTABLISHED

              MAKS         NOT ESTABLISHED                  NOT ESTABLISHED


              RESULT      ISRAEL           ITALY            NIOSH

PENTANE       TWAS        600 PPM TWA      667 PPM TWA      120 PPM TWA
(109-66-0)                (LISTED UNDER    2000 MG/M3 TWA   350 MG/M3 TWA
                          PENTANE, ALL
                          ISOMERS)

              CEILINGS    NOT ESTABLISHED  NOT ESTABLISHED  610 PPM CEILING
                                                            (15 MIN)

                                                            1800 MG/M3
                                                            CEILING
                                                            (15 MIN)

              STELS       NOT ESTABLISHED  NOT ESTABLISHED  NOT ESTABLISHED

SULFUR        STELS       0.25 PPM STEL    NOT ESTABLISHED  5 PPM STEL
DIOXIDE                                                     13 MG/M3 STEL
(7446-09-5)

              TWAS        NOT ESTABLISHED  NOT ESTABLISHED  2 PPM TWA
                                                            5 MG/M3 TWA

HYDROGEN      STELS       5 PPM STEL       NOT ESTABLISHED  NOT ESTABLISHED
SULFIDE
(7783-06-4)   TWAS        1 PPM TWA        NOT ESTABLISHED  NOT ESTABLISHED

              CEILINGS    NOT ESTABLISHED  NOT ESTABLISHED  10 PPM CEILING
                                                            (10 MIN)

                                                            15 MG/M3
                                                            CEILING
                                                            (10 MIN)


              RESULT      OSHA                      OSHA VACATED

PENTANE       TWAS        1000 PPM TWA              600 PPM TWA
                          2950 MG/M3 TWA            1800 MG/M3 TWA

              CEILINGS    NOT ESTABLISHED           NOT ESTABLISHED

              STELS       NOT ESTABLISHED           750 PPM STEL
                                                    2250 MG/M3 STEL

SULFUR        STELS       NOT ESTABLISHED           5 PPM STEL
DIOXIDE                                             15 MG/M3 STEL

              TWAS        5 PPM TWA                 2 PPM TWA
                          13 MG/M3 TWA              5 MG/M3 TWA

HYDROGEN      STELS       NOT ESTABLISHED           15 PPM STEL
SULFIDE                                             21 MG/M3 STEL

              TWAS        NOT ESTABLISHED           10 PPM TWA
                                                    14 MG/M3 TWA

              CEILINGS    20 PPM CEILING            NOT ESTABLISHED

              RESULT    PORTUGAL         SPAIN              SWEDEN

PENTANE       TWAS      600 PPM TWA      1000 PPM TWA       600 PPM LLV
(109-66-0)              [VLE-MP]         [VLA-E[D] VALUE)   1800 MG/M3 LLV

                                         3000 MG/M3 TWA
                                         [VLA-ED]
                                         (INDICATIVE LIMIT
                                         VALUE)

              STELS     NOT ESTABLISHED  NOT ESTABLISHED    750 PPM STV
                                                            2000 MG/M3 STV

SULFUR        STELS     5 PPM STEL       2 PPM STEL         NOT ESTABLISHED
DIOXIDE                 [VLE-CD]         [VLA-EC]
(7446-09-5)
                                         5.28 MG/M3 STEL
                                         [VLA-EC]

              TWAS      2 PPM TWA        1 PPM TWA          2 PPM LLV
                        [VLE-MP]         [VLA-ED]           5 MG/M3 LLV
                                         (IT IS PROHIBITED
                                         THE PARTIAL OR
                                         COMPLETE
                                         COMMERCIALIZATION
                                         OR USE OF THIS
                                         SUBSTANCE AS A
                                         PHYTOSANITARY OR
                                         BIOCIDE COMPOUND)

                                         2.64 MG/M3 TWA
                                         [VLA-ED] (IT IS
                                         PROHIBITED THE
                                         PARTIAL OR
                                         COMPLETE
                                         COMMERCIALIZATION
                                         OR USE OF THIS
                                         SUBSTANCE AS A
                                         PHYTOSANITARY OR
                                         BIOCIDE COMPOUND)

              CEILINGS  NOT ESTABLISHED  NOT ESTABLISHED    5 PPM CLV
                                                            13 MG/M3 CLV

HYDROGEN      STELS     15 PPM STEL      10 PPM STEL        NOT ESTABLISHED
SULFIDE                 [VLE-CD]         [VLA-EC]
(7783-06-4)
                                         14 MG/M3 STEL
                                         [VLA-EC]

              TWAS      10 PPM TWA       5 PPM TWA          10 PPM LLV
                        [VLE-MP]         [VLA-ED]           14 MG/M3 LLV

                                         7 MG/M3 TWA
                                         [VLA-ED]

              CEILINGS  NOT ESTABLISHED  NOT ESTABLISHED    15 PPM CLV
                                                            20 MG/M3 CLV

EXPOSURE CONTROL NOTATIONS:

PORTUGAL:

SULFUR DIOXIDE (7446-09-5):
CARCINOGENS: (A4 - NOT CLASSIFIABLE AS A HUMAN CARCINOGEN)

NITROGEN (7727-37-9):
SIMPLE ASPHYXIANTS: (SIMPLE ASPHYXIANT)

IRELAND:

NITROGEN (7727-37-9):
SIMPLE ASPHYXIANTS: (ASPHYXIANT)

SPAIN:

NITROGEN (7727-37-9):
SIMPLE ASPHYXIANTS: (SIMPLE ASPHYXIANT)

GERMANY DFG:

SULFUR DIOXIDE (7446-09-5):
PREGNANCY: (NO RISK TO EMBRYO/FETUS IF EXPOSURE LIMITS ADHERED TO)

HYDROGEN SULFIDE (7783-06-4):
PREGNANCY: (NO RISK TO EMBRYO/FETUS IF EXPOSURE LIMITS ADHERED TO)

PENTANE (109-66-0):
PREGNANCY: (NO RISK TO EMBRYO/FETUS IF EXPOSURE LIMITS ADHERED TO)

EXPOSURE LIMITS SUPPLEMENTAL:

SPAIN:

SULFUR DIOXIDE (7446-09-5):

UNDER REVIEW:
(0.5 PPM VLA-ED; 1 PPM VLA-EC; IT IS PROHIBITED THE PARTIAL OR COMPLETE
COMMERCIALIZATION OR USE OF THIS SUBSTANCE AS A PHYTOSANITARY O BIOCIDE
COMPOUND)

8.2 EXPOSURE CONTROLS:

ENGINEERING MEASURES/CONTROLS:
GOOD GENERAL VENTILATION SHOULD BE USED. VENTILATION RATES SHOULD BE
MATCHED TO CONDITIONS. IF APPLICABLE, USE PROCESS ENCLOSURES, LOCAL EXHAUST
VENTILATION, OR OTHER ENGINEERING CONTROLS TO MAINTAIN AIRBORNE LEVELS
BELOW RECOMMENDED EXPOSURE LIMITS. IF EXPOSURE LIMITS HAVE NOT BEEN
ESTABLISHED, MAINTAIN AIRBORNE LEVELS TO AN ACCEPTABLE LEVEL.

PERSONAL PROTECTIVE EQUIPMENT:

RESPIRATORY:
FOLLOW THE OSHA RESPIRATOR REGULATIONS FOUND IN 29 CFR 1910.134 OR EUROPEAN
STANDARD EN 149. USE A NIOSH/MSHA OR EUROPEAN STANDARD EN 149 APPROVED
RESPIRATOR IF EXPOSURE LIMITS ARE EXCEEDED OR SYMPTOMS ARE EXPERIENCED.

EYE/FACE: WEAR SAFETY GLASSES.

SKIN/BODY: WEAR LEATHER GLOVES WHEN HANDLING CYLINDERS.

ENVIRONMENTAL EXPOSURE CONTROLS:
FOLLOW BEST PRACTICE FOR SITE MANAGEMENT AND DISPOSAL OF WASTE. CONTROLS
SHOULD BE ENGINEERED TO PREVENT RELEASE TO THE ENVIRONMENT, INCLUDING
PROCEDURES TO PREVENT SPILLS, ATMOSPHERIC RELEASE AND RELEASE TO WATERWAYS.

KEY TO ABBREVIATIONS:

ACGIH: AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENE

LLV: LIMIT LEVEL VALUE IS THE EXPOSURE LIMIT FOR 8-HOUR WORK DAY

MAK:
MAXIMALE ARBEITSPLATZ KONZENTRATION IS THE MAXIMUM PERMISSIBLE
CONCENTRATION

NIOSH: NATIONAL INSTITUTE OF OCCUPATIONAL SAFETY AND HEALTH

OSHA: OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION

STEL: SHORT TERM EXPOSURE LIMITS ARE BASED ON 15-MINUTE EXPOSURES

STEV: SHORT TERM EXPOSURE VALUE

TWAEV: TIME-WEIGHTED AVERAGE EXPOSURE VALUE

TWA: TIME-WEIGHTED AVERAGES ARE BASED ON 8H/DAY, 40H/WEEK EXPOSURES


SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES 


9.1 INFORMATION ON PHYSICAL AND CHEMICAL PROPERTIES:

MATERIAL DESCRIPTION:

PHYSICAL FORM: GAS

APPEARANCE/DESCRIPTION: COLORLESS GAS WITH ROTTEN EGG ODOR.

COLOR: COLORLESS

ODOR: ROTTEN-EGG

ODOR THRESHOLD: 013 PPM (HYDROGEN SULFIDE)

GENERAL PROPERTIES:

BOILING POINT: -195.8 C (-320.44 F) (NITROGEN)

MELTING POINT: -210 C (-346 F) (NITROGEN)

DECOMPOSITION TEMPERATURE: DATA LACKING

PH: NOT RELEVANT

SPECIFIC GRAVITY/RELATIVE DENSITY: 0.906 WATER=1 (NITROGEN)

DENSITY: 0.072 LB(S)/FT3 @ 0 C(32 F) (NITROGEN)

WATER SOLUBILITY: DATA LACKING

VISCOSITY: DATA LACKING

EXPLOSIVE PROPERTIES: DATA LACKING

OXIDIZING PROPERTIES: DATA LACKING

VOLATILITY:

VAPOR PRESSURE: DATA LACKING

VAPOR DENSITY: DATA LACKING

EVAPORATION RATE: DATA LACKING

FLAMMABILITY:

FLASH POINT: NOT RELEVANT

UEL: NOT RELEVANT
LEL: NOT RELEVANT

AUTOIGNITION: DATA LACKING

FLAMMABILITY (SOLID, GAS): NONFLAMMABLE GAS.

ENVIRONMENTAL:
OCTANOL/WATER PARTITION COEFFICIENT: DATA LACKING

9.2 OTHER INFORMATION:
NO ADDITIONAL PHYSICAL AND CHEMICAL PARAMETERS NOTED.


SECTION 10 - STABILITY AND REACTIVITY 


10.1 REACTIVITY:
NO DANGEROUS REACTION KNOWN UNDER CONDITIONS OF NORMAL USE.

10.2 CHEMICAL STABILITY: STABLE UNDER NORMAL TEMPERATURES AND PRESSURES.

10.3 POSSIBILITY OF HAZARDOUS REACTIONS:
HAZARDOUS POLYMERIZATION WILL NOT OCCUR.

10.4 CONDITIONS TO AVOID: EXCESS HEAT.

10.5 INCOMPATIBLE MATERIALS:
TITANIUM WILL BURN IN NITROGEN (THE MAIN COMPONENT OF THIS GAS MIXTURE).
LITHIUM REACTS SLOWLY WITH NITROGEN AT AMBIENT TEMPERATURES. DUE TO THE
PRESENCE OF PENTANE AND HYDROGEN SULFIDE, THIS GAS MIXTURE MAY BE
INCOMPATIBLE WITH STRONG OXIDIZERS. HYDROGEN SULFIDE IS CORROSIVE TO MOST
METALS DUE TO REACTION WITH METALS TO FORM METAL SULFIDES. PENTANE IS
INCOMPATIBLE WITH HALOGENS.

THE TRACE SULFUR DIOXIDE COMPONENT IS INCOMPATIBLE WITH THE FOLLOWING
MATERIALS:
CHLORATES, FLUORINE, INTERHALOGENS, SODIUM HYDRIDE, SODIUM, BASES, SILVER
AZIDE, BARIUM PEROXIDE, DIETHYL ZINC, NITRYL CHLORIDE, POWDERED METALS,
POTASSIUM, ACROLEIN, LITHIUM NITRATE AND PROPENE, MONOLITHIUM
ACETYLIDE-AMMONIA (LITHIUM ACETYLENE CARBIDE DIAMMINO), CESIUM AZIDE, METAL
OXIDES, METAL ACETYLIDES, AND CARBIDE. ALTHOUGH THE SULFUR DIOXIDE
COMPONENT IS IN LOW CONCENTRATION AND SIGNIFICANT REACTION IS NOT EXPECTED,
CAUTION SHOULD BE USED IF CONTACT WITH THIS GAS MIXTURE AND THESE MATERIALS
CAN OCCUR.

10.6 HAZARDOUS DECOMPOSITION PRODUCTS:
COMBUSTION: SULFUR OXIDES, CARBON OXIDES.

HYDROLYSIS: SULFUROUS ACID.


SECTION 11 - TOXICOLOGICAL INFORMATION 


11.1 INFORMATION ON TOXICOLOGICAL EFFECTS:

COMPONENTS:

SULFUR DIOXIDE      7446-09-05     ACUTE TOXICITY:
                                   INHALATION-RAT LC50: 2520 PPM 1 HOUR(S)

                                   IRRITATION:
                                   EYE-RABBIT:
                                   6 PPM 32 DAY(S)
                                   MILD IRRITATION

                                   MUTAGEN:
                                   CYTOGENETIC ANALYSIS:
                                   INHALATION-MOUSE:
                                   14 (MICRO)G/L 4 HOUR(S) 7 DAY(S)

                                   MICRONUCLEUS TEST:
                                   INHALATION-MOUSE:
                                   28 (MICRO)G/L 5 DAY(S)-INTERMITTENT

                                   DNA ADDUCT:
                                   INHALATION-RAT:
                                   72 MG/KG 300 DAY(S)-INTERMITTENT

                                   REPRODUCTIVE:
                                   INHALATION-MOUSE TCLO:
                                   25 PPM 7 HOUR(S)(6-15D PREG)

                                   REPRODUCTIVE EFFECTS:
                                   SPECIFIC DEVELOPMENTAL ABNORMALITIES:
                                   MUSCULOSKELETAL SYSTEM

                                   INHALATION-RABBIT TCLO:
                                   70 PPM 7 HOUR(S)(6-18D PREG)

                                   REPRODUCTIVE EFFECTS:
                                   SPECIFIC DEVELOPMENTAL ABNORMALITIES:
                                   MUSCULOSKELETAL SYSTEM

HYDROGEN SULFIDE    7783-06-4      ACUTE TOXICITY:
(0.001% TO 0.025%)                 INHALATION-RAT LC50: 700 MG/M3 4 HOUR(S)

                                   IRRITATION:
                                   EYE-HUMAN: 0.000125 PPM 5 HOUR(S)

                                   REPRODUCTIVE:
                                   INHALATION-RAT TCLO:
                                   10 MG/M3 (48D PRE/1-22D PREG)

                                   REPRODUCTIVE EFFECTS:
                                   EFFECTS ON FERTILITY.
                                   PRE-IMPLANTATION MORTALITY

                                   REPRODUCTIVE EFFECTS:
                                   EFFECTS ON FERTILITY:
                                   POST-IMPLANTATION MORTALITY

                                   REPRODUCTIVE EFFECTS:
                                   SPECIFIC DEVELOPMENTAL ABNORMALITIES:
                                   UROGENITAL SYSTEM

PENTANE              109-66-0      ACUTE TOXICITY:
(0% TO 0.75%)                      INGESTION/ORAL-RAT LD50: >2000 MG/KG

                                   INHALATION-RAT LC50: 364 G/M3 4 HOUR(S)

OXYGEN              7782-44-7      REPRODUCTIVE:
(0% TO 23.5%)                      INHALATION-RAT TCLO:
                                   10 PPH 9 HOUR(S)(22D PREG)

                                   REPRODUCTIVE EFFECTS:
                                   SPECIFIC DEVELOPMENTAL ABNORMALITIES:
                                   RESPIRATORY SYSTEM

                                   REPRODUCTIVE EFFECTS:
                                   EFFECTS ON NEWBORN: PHYSICAL

GHS PROPERTIES                     CLASSIFICATION

ACUTE TOXICITY                     EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

ASPIRATION HAZARD                  EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

CARCINOGENICITY                    EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

GERM CELL MUTAGENICITY             EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

SKIN CORROSION/IRRITATION          EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

SKIN SENSITIZATION                 EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

STOT-RE                            EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

STOT-SE                            EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

TOXICITY FOR REPRODUCTION          EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

RESPIRATORY SENSITIZATION          EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

SERIOUS EYE DAMAGE/IRRITATION      EU/CLP: DATA LACKING
                                   OSHA HCS 2012: DATA LACKING

POTENTIAL HEALTH EFFECTS:

INHALATION:

ACUTE (IMMEDIATE):
THIS MATERIAL IS A SIMPLE ASPHYXIANT. MAY DISPLACE OR REDUCE OXYGEN
AVAILABLE FOR BREATHING ESPECIALLY IN CONFINED SPACES. IF THIS MATERIAL IS
RELEASED IN A SMALL, POORLY VENTILATED AREA (I.E. AN ENCLOSED OR CONFINED
SPACE), AN OXYGEN-DEFICIENT ENVIRONMENT MAY OCCUR. INDIVIDUALS BREATHING
SUCH AN ATMOSPHERE MAY EXPERIENCE SYMPTOMS WHICH INCLUDE HEADACHES, RINGING
IN EARS, DIZZINESS, DROWSINESS, UNCONSCIOUSNESS, NAUSEA, VOMITING, AND
DEPRESSION OF ALL THE SENSES. UNDER SOME CIRCUMSTANCES OF OVER-EXPOSURE,
DEATH MAY OCCUR. THE FOLLOWING EFFECTS ASSOCIATED WITH DECREASED LEVELS OF
OXYGEN: INCREASE IN BREATHING AND PULSE RATE, EMOTIONAL UPSET, ABNORMAL
FATIGUE, NAUSEA, VOMITING, COLLAPSE, LOSS OF CONSCIOUSNESS, CONVULSIVE
MOVEMENTS, RESPIRATORY COLLAPSE AND DEATH.

CHRONIC (DELAYED): NO DATA AVAILABLE

SKIN:

ACUTE (IMMEDIATE):
UNDER NORMAL CONDITIONS OF USE, NO HEALTH EFFECTS ARE EXPECTED.

CHRONIC (DELAYED):
UNDER NORMAL CONDITIONS OF USE, NO HEALTH EFFECTS ARE EXPECTED.

EYE:

ACUTE (IMMEDIATE):
UNDER NORMAL CONDITIONS OF USE, NO HEALTH EFFECTS ARE EXPECTED.

CHRONIC (DELAYED):
UNDER NORMAL CONDITIONS OF USE, NO HEALTH EFFECTS ARE EXPECTED.

INGESTION:

ACUTE (IMMEDIATE):
INGESTION IS NOT ANTICIPATED TO BE A LIKELY ROUTE OF EXPOSURE TO THIS
PRODUCT.

CHRONIC (DELAYED):
INGESTION IS NOT ANTICIPATED TO BE A LIKELY ROUTE OF EXPOSURE TO THIS
PRODUCT.

KEY TO ABBREVIATIONS:
LC = LETHAL CONCENTRATION
LD = LETHAL DOSE
TC = TOXIC CONCENTRATION


SECTION 12 - ECOLOGICAL INFORMATION 


12.1 TOXICITY: MATERIAL DATA LACKING.

12.2 PERSISTENCE AND DEGRADABILITY: MATERIAL DATA LACKING.

12.3 BIOACCUMULATIVE POTENTIAL: MATERIAL DATA LACKING.

12.4 MOBILITY IN SOIL: MATERIAL DATA LACKING.

12.5 RESULTS OF PBT AND VPVB ASSESSMENT:
PBT AND VPVB ASSESSMENT HAS NOT BEEN CONDUCTED FOR THIS MATERIAL.

12.6 OTHER ADVERSE EFFECTS: NO STUDIES HAVE BEEN FOUND.


SECTION 13 - DISPOSAL CONSIDERATIONS 


13.1 WASTE TREATMENT METHODS:

PRODUCT WASTE:
DISPOSE OF CONTENT AND/OR CONTAINER IN ACCORDANCE WITH LOCAL, REGIONAL,
NATIONAL, AND/OR INTERNATIONAL REGULATIONS.

PACKAGING WASTE:
DISPOSE OF CONTENT AND/OR CONTAINER IN ACCORDANCE WITH LOCAL, REGIONAL,
NATIONAL, AND/OR INTERNATIONAL REGULATIONS.


SECTION 14 - TRANSPORT INFORMATION 


            14.1 UN  14.2 UN PROPER      14.3        14.4     14.5
            NUMBER   SHIPPING NAME       TRANSPORT   PACKING  ENVIRONMENTAL
                                         HAZARDS     GROUP    HAZARD
                                         CLASS(ES)

DOT         UN1956   COMPRESSED GASES,   2.2         NDA      NDA
                     N.O.S. (NITROGEN,
                     OXYGEN)

TDG         UN1956   COMPRESSED GASES,   2.2         NDA      NDA
                     N.O.S. (NITROGEN,
                     OXYGEN)

IMO/IMDG    UN1956   COMPRESSED GASES,   2.2         NDA      NDA
                     N.O.S. (NITROGEN,
                     OXYGEN)

IATA/ICAO   UN1956   COMPRESSED GASES,   2.2         NDA      NDA
                     N.O.S. (NITROGEN,
                     OXYGEN)

14.6 SPECIAL PRECAUTIONS FOR USER:
CYLINDERS SHOULD BE TRANSPORTED IN A SECURE POSITION, IN A WELL-VENTILATED
VEHICLE. THE TRANSPORTATION OF COMPRESSED GAS CYLINDERS IN AUTOMOBILES OR
IN CLOSED-BODY VEHICLES CAN PRESENT SERIOUS SAFETY HAZARDS. IF TRANSPORTING
THESE CYLINDERS IN VEHICLES, ENSURE THESE CYLINDERS ARE NOT EXPOSED TO
EXTREMELY HIGH TEMPERATURES (AS MAY OCCUR IN AN ENCLOSED VEHICLE ON A HOT
DAY). ADDITIONALLY, THE VEHICLE SHOULD BE WELL-VENTILATED DURING
TRANSPORTATION.

14.7 TRANSPORT IN BULK ACCORDING TO ANNEX II OF MARPOL 73/78 AND THE IBC
CODE: DATA LACKING.


SECTION 15 - REGULATORY INFORMATION 


15.1 SAFETY, HEALTH AND ENVIRONMENTAL REGULATIONS/LEGISLATION SPECIFIC FOR
THE SUBSTANCE OR MIXTURE:

SARA HAZARD CLASSIFICATIONS: PRESSURE(SUDDEN RELEASE OF), ACUTE

STATE RIGHT TO KNOW:

COMPONENT               CAS             MA         NJ           PA

HYDROGEN SULFIDE        7783-06-4       YES        YES          YES

NITROGEN                7727-37-9       YES        YES          YES

OXYGEN                  7782-44-7       YES        YES          YES

PENTANE                  109-66-0       YES        YES          YES

SULFUR DIOXIDE          7446-09-5       YES        YES          YES

INVENTORY:

COMPONENT    CAS        CANADA DSL  CANADA NDSL  CHINA  EU EINECS EU ELNICS

HYDROGEN     7783-06-4  YES         NO           YES    YES       NO
SULFIDE

NITROGEN     7727-37-9  YES         NO           YES    YES       NO

OXYGEN       7782-44-7  YES         NO           YES    YES       NO

PENTANE       109-66-0  YES         NO           YES    YES       NO

SULFUR       7446-09-5  YES         NO           YES    YES       NO
DIOXIDE

COMPONENT                    CAS                  TSCA

HYDROGEN SULFIDE             7783-06-4            YES

NITROGEN                     7727-37-9            YES

OXYGEN                       7782-44-7            YES

PENTANE                       109-66-0            YES

SULFUR DIOXIDE               7446-09-5            YES

CANADA:

LABOR:

CANADA - WHMIS - CLASSIFICATIONS OF SUBSTANCES:

HYDROGEN SULFIDE                        7783-06-4         A, B1, D1 A, D2B

PENTANE                                  109-66-0         B2

OXYGEN                                  7782-44-7         A, C

SULFUR DIOXIDE                          7446-09-5         A, D1A, D2B, E

NITROGEN                                7727-37-9         A

CANADA - WHMIS - INGREDIENT DISCLOSURE LIST:

HYDROGEN SULFIDE                        7783-06-4         1%

PENTANE                                  109-66-0         1%

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         1%

NITROGEN                                7727-37-9         NOT LISTED

ENVIRONMENT:

CANADA - CEPA - PRIORITY SUBSTANCES LIST:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

CHINA:

ENVIRONMENT:

CHINA - OZONE DEPLETING SUBSTANCES - FIRST SCHEDULE:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

CHINA - OZONE DEPLETING SUBSTANCES - SECOND SCHEDULE:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

CHINA - OZONE DEPLETING SUBSTANCES - THIRD SCHEDULE:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

OTHER:

CHINA - ANNEX I & II - CONTROLLED CHEMICALS LISTS:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

CHINA - DANGEROUS GOODS LIST:

HYDROGEN SULFIDE                        7783-06-4

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         (COMPRESSED OR
                                                          REFRIGERATED
                                                          LIQUID)

SULFUR DIOXIDE                          7446-09-5

NITROGEN                                7727-37-9         (COMPRESSED OR
                                                          REFRIGERATED
                                                          LIQUID)

CHINA - EXPORT CONTROL LIST - PART I CHEMICALS:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

EUROPE:

OTHER:

EU - CLP (1272/2008) - ANNEX VI - TABLE 3.2 - CLASSIFICATION:

HYDROGEN SULFIDE                        7783-06-4         F+; R12 T+;
                                                          R26 N; R50

PENTANE                                  109-66-0         F+; R12 N; R51-53
                                                          XN; R65 R66 R67

OXYGEN                                  7782-44-7         O; R8

SULFUR DIOXIDE                          7446-09-5         T; R23 C; R34

NITROGEN                                7727-37-9         NOT LISTED

EU - CLP (1272/2008) - ANNEX VI - TABLE 3.2 - CONCENTRATION LIMITS:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         20% <=C: T;
                                                          R: 23
                                                          5% <=C<20%: XN;
                                                          R: 20

NITROGEN                                7727-37-9         NOT LISTED

EU - CLP (1272/2008) - ANNEX VI - TABLE 3.2 - LABELING:

HYDROGEN SULFIDE                        7783-06-4         F+ T+ N R:
                                                          12-26-50

                                                          S:
                                                          (1/2)-9-16-
                                                          36-38-45-61

PENTANE                                  109-66-0         F+ XN N
                                                          R:
                                                          12-51/53-65-66-67

                                                          S:
                                                          (2)-9-16-29-
                                                          33-61-62

OXYGEN                                  7782-44-7         O R: 8
                                                          S: (2)-17

SULFUR DIOXIDE                          7446-09-5         T R: 23-34

                                                          S:
                                                          (1/2)-9-26-
                                                          36/37/39-45

NITROGEN                                7727-37-9         NOT LISTED

EU - CLP (1272/2008) - ANNEX VI - TABLE 3.2 - NOTES - SUBSTANCES AND
PREPARATIONS:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         C

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         5

NITROGEN                                7727-37-9         NOT LISTED

EU - CLP (1272/2008) - ANNEX VI - TABLE 3.2 - SAFETY PHRASES:

HYDROGEN SULFIDE                        7783-06-4         S:
                                                          (1/2)-9-16-36-
                                                          38-45-61

PENTANE                                  109-66-0         S:
                                                          (2)-9-16-29-
                                                          33-61-62

OXYGEN                                  7782-44-7         S: (2)-17

SULFUR DIOXIDE                          7446-09-5         S:
                                                          (1/2)-9-26-
                                                          36/37/39-45

NITROGEN                                7727-37-9         NOT LISTED

GERMANY:

ENVIRONMENT:

GERMANY - TA LUFT - TYPES AND CLASSES:

HYDROGEN SULFIDE                        7783-06-4         INORGANIC GAS
                                                          SUBSTANCE:
                                                          5.2.4, CLASS II

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         INORGANIC GAS
                                                          SUBSTANCE:
                                                          5.2.4, CLASS IV

NITROGEN                                7727-37-9         NOT LISTED

GERMANY - WATER CLASSIFICATION (VWVWS) - ANNEX 1:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         ID NUMBER 743,
                                                          NOT CONSIDERED
                                                          HAZARDOUS TO
                                                          WATER

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         ID NUMBER 1351,
                                                          NOT CONSIDERED
                                                          HAZARDOUS TO
                                                          WATER

GERMANY - WATER CLASSIFICATION (VWVWS) - ANNEX 2 - WATER HAZARD CLASSES:

HYDROGEN SULFIDE                        7783-06-4         ID NUMBER 283,
                                                          HAZARD CLASS 2 -
                                                          HAZARD TO WATERS

PENTANE                                  109-66-0         ID NUMBER 452,
                                                          HAZARD CLASS 2 -
                                                          HAZARD TO WATERS

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         ID NUMBER 416,
                                                          HAZARD CLASS 1 -
                                                          LOW HAZARD TO
                                                          WATERS
                                                          (FOOTNOTE 8)

NITROGEN                                7727-37-9         NOT LISTED

GERMANY - WATER CLASSIFICATION (VWVWS) - ANNEX 3:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

OTHER:

GERMANY - SPECIFICALLY REGULATED CHEMICALS IN TRGS:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

PORTUGAL:

OTHER:

PORTUGAL - PROHIBITED SUBSTANCES:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

UNITED KINGDOM:

ENVIRONMENT:

UNITED KINGDOM - POLLUTION INVENTORY - SCHEDULE 1 - THRESHOLDS FOR RELEASES
TO AIR:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

OTHER:

UNITED KINGDOM - WORKPLACE EXPOSURE LIMITS (WELS) - SUBSTANCES IN REVIEW:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

UNITED KINGDOM - LIST OF DANGEROUS SUBSTANCES IN WATER:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

UNITED STATES:

LABOR:

U.S. - OSHA - PROCESS SAFETY MANAGEMENT - HIGHLY HAZARDOUS CHEMICALS:

HYDROGEN SULFIDE                        7783-06-4         1500 LB TQ

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         1000 LB TQ
                                                          (LIQUID)

NITROGEN                                7727-37-9         NOT LISTED

U.S. - OSHA - SPECIFICALLY REGULATED CHEMICALS:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

ENVIRONMENT:

U.S. - CAA (CLEAN AIR ACT) - 1990 HAZARDOUS AIR POLLUTANTS:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CERCLA/SARA - HAZARDOUS SUBSTANCES AND THEIR REPORTABLE QUANTITIES:

HYDROGEN SULFIDE                        7783-06-4         100 LB FINAL RQ
                                                          45.4 KG FINAL RQ

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CERCLA/SARA - RADIONUCLIDES AND THEIR REPORTABLE QUANTITIES:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CERCLA/SARA - SECTION 302 EXTREMELY HAZARDOUS SUBSTANCES EPCRA RQS:

HYDROGEN SULFIDE                        7783-06-4         100 LB EPCRA RQ

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         500 LB EPCRA RQ

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CERCLA/SARA - SECTION 302 EXTREMELY HAZARDOUS SUBSTANCES TPQS:

HYDROGEN SULFIDE                        7783-06-4         500 LB TPQ

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         500 LB TPQ

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CERCLA/SARA - SECTION 313 - EMISSION REPORTING:

HYDROGEN SULFIDE                        7783-06-4         1.0 % DE MINIMIS
                                                          CONCENTRATION

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CERCLA/SARA - SECTION 313 - PBT CHEMICAL LISTING:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - RCRA (RESOURCE CONSERVATION & RECOVERY ACT) - HAZARDOUS
CONSTITUENTS - APPENDIX VIII TO 40 CFR 261:

HYDROGEN SULFIDE                        7783-06-4         WASTE NUMBER U135

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - RCRA (RESOURCE CONSERVATION & RECOVERY ACT) - U SERIES WASTES -
ACUTELY TOXIC WASTES & OTHER HAZARDOUS CHARACTERISTICS:

HYDROGEN SULFIDE                        7783-06-4         WASTE NUMBER U135

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

UNITED STATES - CALIFORNIA:

ENVIRONMENT:

U.S. - CALIFORNIA - PROPOSITION 65 - CARCINOGENS LIST:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CALIFORNIA - PROPOSITION 65 - DEVELOPMENTAL TOXICITY:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         DEVELOPMENTAL
                                                          TOXICITY, INITIAL
                                                          DATE 7/29/11

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CALIFORNIA - PROPOSITION 65 - MAXIMUM ALLOWABLE DOSE LEVELS (MADL):

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CALIFORNIA - PROPOSITION 65 - NO SIGNIFICANT RISK LEVELS (NSRL):

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CALIFORNIA - PROPOSITION 65 - REPRODUCTIVE TOXICITY - FEMALE:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

U.S. - CALIFORNIA - PROPOSITION 65 - REPRODUCTIVE TOXICITY - MALE:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

UNITED STATES - PENNSYLVANIA:

LABOR:

U.S. - PENNSYLVANIA - RTK (RIGHT TO KNOW) - ENVIRONMENTAL HAZARD LIST:

HYDROGEN SULFIDE                        7783-06-4

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5

NITROGEN                                7727-37-9         NOT LISTED

U.S. - PENNSYLVANIA - RTK (RIGHT TO KNOW) - SPECIAL HAZARDOUS SUBSTANCES:

HYDROGEN SULFIDE                        7783-06-4         NOT LISTED

PENTANE                                  109-66-0         NOT LISTED

OXYGEN                                  7782-44-7         NOT LISTED

SULFUR DIOXIDE                          7446-09-5         NOT LISTED

NITROGEN                                7727-37-9         NOT LISTED

15.2 CHEMICAL SAFETY ASSESSMENT:
NO CHEMICAL SAFETY ASSESSMENT HAS BEEN CARRIED OUT.

15.3 OTHER INFORMATION:

WARNING:
THIS PRODUCT CONTAINS A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE
BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.


SECTION 16 - OTHER INFORMATION 


RELEVANT PHRASES (CODE & FULL TEXT):

H220: EXTREMELY FLAMMABLE GAS

H224: EXTREMELY FLAMMABLE LIQUID AND VAPOUR

H270: MAY CAUSE OR INTENSIFY FIRE; OXIDIZER

H304: MAY BE FATAL IF SWALLOWED AND ENTERS AIRWAYS

H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.

H330: FATAL IF INHALED

H331: TOXIC IF INHALED

H400: VERY TOXIC TO AQUATIC LIFE

R8: CONTACT WITH COMBUSTIBLE MATERIAL MAY CAUSE FIRE.

R12: EXTREMELY FLAMMABLE.

R23: TOXIC BY INHALATION.

R26: VERY TOXIC BY INHALATION.

R34: CAUSES BURNS.

R50: VERY TOXIC TO AQUATIC ORGANISMS.

R51: TOXIC TO AQUATIC ORGANISMS.

R53: MAY CAUSE LONG-TERM ADVERSE EFFECTS IN THE AQUATIC ENVIRONMENT.

R65:
HARMFUL: MAY CAUSE LUNG DAMAGE IF SWALLOWED.

R66: REPEATED EXPOSURE MAY CAUSE SKIN DRYNESS OR CRACKING.

R67: VAPOURS MAY CAUSE DROWSINESS AND DIZZINESS.

LAST REVISION DATE: 17/OCTOBER/2014

PREPARATION DATE: 17/OCTOBER/2014

DISCLAIMER/STATEMENT OF LIABILITY:
TO THE BEST OF AIR LIQUIDE'S KNOWLEDGE, THE INFORMATION CONTAINED HEREIN IS
RELIABLE AND ACCURATE AS OF THIS DATE; HOWEVER, ACCURACY, SUITABILITY OR
COMPLETENESS ARE NOT GUARANTEED AND NO WARRANTIES OF ANY TYPE, EITHER
EXPRESS OR IMPLIED, ARE PROVIDED. THE INFORMATION CONTAINED HEREIN RELATES
ONLY TO THIS SPECIFIC PRODUCT. IF THIS GAS MIXTURE IS COMBINED WITH OTHER
MATERIALS, ALL COMPONENT PROPERTIES MUST BE CONSIDERED. DATA MAY BE CHANGED
FROM TIME TO TIME. BE SURE TO CONSULT THE LATEST EDITION.

KEY TO ABBREVIATIONS:
NDA = NO DATA AVAILABLE

REVISION DATE: 17/OCTOBER/2014

FORMAT: EU CLP/REACH

LANGUAGE: ENGLISH (US)

WHMIS, EU CLP, EU DSD/DPD, OSHA HCS 2012