Common Name: KRYTOX 157FS OILS
Manufacturer: DU PONT
SDS Revision Date: 4/3/2015
SDS Format: GHS-US
   
Item Number(s): 35RR06, 35RR08, 35RR09, 35RR10, 35RR12, 35RR13, 35RR15, 35RR16
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION 
SECTION 2. HAZARDS IDENTIFICATION 
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION 4. FIRST AID MEASURES 
SECTION 5. FIREFIGHTING MEASURES 
SECTION 6. ACCIDENTAL RELEASE MEASURES 
SECTION 7. HANDLING AND STORAGE 
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10. STABILITY AND REACTIVITY 
SECTION 11. TOXICOLOGICAL INFORMATION 
SECTION 12. ECOLOGICAL INFORMATION 
SECTION 13. DISPOSAL CONSIDERATIONS 
SECTION 14. TRANSPORT INFORMATION 
SECTION 15. REGULATORY INFORMATION 
SECTION 16. OTHER INFORMATION 



DUPONT(R*)

SAFETY DATA SHEET

DUPONT(TM) KRYTOX(R*) 157FS OILS

VERSION: 0.0

REVISION DATE: 04/03/2015

REF.: 150000002944

THIS SDS ADHERES TO THE STANDARDS AND REGULATORY REQUIREMENTS OF THE UNITED
STATES AND MAY NOT MEET THE REGULATORY REQUIREMENTS IN OTHER COUNTRIES.


SECTION 1. PRODUCT AND COMPANY IDENTIFICATION 


PRODUCT NAME: DUPONT(TM) KRYTOX(R*) 157FS OILS

TRADENAME/SYNONYM: FLUOROGUARD FSM

PRODUCT GRADE/TYPE:
157: FSL, FSM, FSH

PRODUCT USE: LUBRICANT, FOR INDUSTRIAL USE ONLY.

RESTRICTIONS ON USE:
DO NOT USE PRODUCT FOR ANYTHING OUTSIDE OF THE ABOVE SPECIFIED USES

MANUFACTURER/SUPPLIER:
DUPONT
1007 MARKET STREET
WILMINGTON, DE 19898
UNITED STATES OF AMERICA

PRODUCT INFORMATION: 1-800-441-7515 (OUTSIDE THE U.S. 1-302-774-1000)

MEDICAL EMERGENCY: 1-800-441-3637 (OUTSIDE THE U.S. 1-302-774-1139)

TRANSPORT EMERGENCY:
CHEMTREC: +1-800-424-9300 (OUTSIDE THE U.S. +1-703-527-3887)

OTHER INFORMATION: PROFESSIONAL USE


SECTION 2. HAZARDS IDENTIFICATION 


PRODUCT HAZARD CATEGORY:
SERIOUS EYE DAMAGE/EYE IRRITATION: CATEGORY 2B
SKIN SENSITISATION: CATEGORY 1

LABEL CONTENT:
PICTOGRAM: EXCLAMATION MARK

SIGNAL WORD: WARNING

HAZARDOUS WARNINGS:
MAY CAUSE AN ALLERGIC SKIN REACTION.
CAUSES EYE IRRITATION.

HAZARDOUS PREVENTION MEASURES:
AVOID BREATHING DUST/FUME/GAS/MIST/VAPOURS/SPRAY.
WASH SKIN THOROUGHLY AFTER HANDLING.
CONTAMINATED WORK CLOTHING SHOULD NOT BE ALLOWED OUT OF THE WORKPLACE.
WEAR PROTECTIVE GLOVES.

IF ON SKIN: WASH WITH PLENTY OF SOAP AND WATER.

IF IN EYES:
RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES. REMOVE CONTACT LENSES, IF
PRESENT AND EASY TO DO. CONTINUE RINSING.

IF SKIN IRRITATION OR RASH OCCURS: GET MEDICAL ADVICE/ATTENTION.

IF EYE IRRITATION PERSISTS: GET MEDICAL ADVICE/ATTENTION.

WASH CONTAMINATED CLOTHING BEFORE REUSE.

DISPOSE OF CONTENTS/CONTAINER TO AN APPROVED WASTE DISPOSAL PLANT.

OTHER HAZARDS:
REPEATED OR PROLONGED SKIN CONTACT MAY CAUSE ALLERGIC REACTIONS WITH
SUSCEPTIBLE PERSONS., INHALATION OF DECOMPOSITION PRODUCTS FROM OVERHEATING
MAY CAUSE LUNG IRRITATION OR SHORTNESS OF BREATH.


SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS 


COMPONENT                    CAS-NO.             CONCENTRATION

FLUOROCOMPOUND                                   100%


SECTION 4. FIRST AID MEASURES 


GENERAL ADVICE:
WHEN SYMPTOMS PERSIST OR IN ALL CASES OF DOUBT SEEK MEDICAL ADVICE.

INHALATION:
MOVE TO FRESH AIR IN CASE OF ACCIDENTAL INHALATION OF FUMES FROM
OVERHEATING OR COMBUSTION.

SKIN CONTACT: WASH OFF WITH SOAP AND PLENTY OF WATER.

EYE CONTACT:
RINSE WITH PLENTY OF WATER. IF EYE IRRITATION PERSISTS, CONSULT A
SPECIALIST.

INGESTION:
NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO NOT INDUCE
VOMITING UNLESS DIRECTED TO DO SO BY A PHYSICIAN OR POISON CONTROL CENTER.

MOST IMPORTANT SYMPTOMS/EFFECTS, ACUTE AND DELAYED:
NO APPLICABLE DATA AVAILABLE.

PROTECTION OF FIRST-AIDERS:
IF POTENTIAL FOR EXPOSURE EXISTS REFER TO SECTION 8 FOR SPECIFIC PERSONAL
PROTECTIVE EQUIPMENT.

NOTES TO PHYSICIAN: NO APPLICABLE DATA AVAILABLE.


SECTION 5. FIREFIGHTING MEASURES 


SUITABLE EXTINGUISHING MEDIA:
THE PRODUCT ITSELF DOES NOT BURN.

USE EXTINGUISHING MEASURES THAT ARE APPROPRIATE TO LOCAL CIRCUMSTANCES AND
THE SURROUNDING ENVIRONMENT.

UNSUITABLE EXTINGUISHING MEDIA: NO APPLICABLE DATA AVAILABLE.

SPECIFIC HAZARDS:
IN FIRE CONDITIONS, TOXIC DECOMPOSITION PRODUCTS MAY BE FORMED.
(SEE ALSO SECTION 10)

SPECIAL PROTECTIVE EQUIPMENT FOR FIREFIGHTERS:
WEAR SELF-CONTAINED BREATHING APPARATUS (SCBA). WEAR SUITABLE PROTECTIVE
EQUIPMENT.

FURTHER INFORMATION: STANDARD PROCEDURE FOR CHEMICAL FIRES.


SECTION 6. ACCIDENTAL RELEASE MEASURES 


NOTE:
REVIEW FIRE FIGHTING MEASURES AND HANDLING (PERSONNEL) SECTIONS BEFORE
PROCEEDING WITH CLEAN-UP USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT
DURING CLEAN-UP.

SAFEGUARDS (PERSONNEL): NO APPLICABLE DATA AVAILABLE.

ENVIRONMENTAL PRECAUTIONS:
PREVENT MATERIAL FROM ENTERING SEWERS, WATERWAYS, OR LOW AREAS.

SPILL CLEANUP:
SOAK UP WITH INERT ABSORBENT MATERIAL (E.G. SAND, SILICA GEL, ACID BINDER,
UNIVERSAL BINDER, SAWDUST).

ACCIDENTAL RELEASE MEASURES: NO APPLICABLE DATA AVAILABLE.


SECTION 7. HANDLING AND STORAGE 


HANDLING (PERSONNEL):
AVOID BREATHING VAPORS FROM OVERHEATED MATERIAL. AVOID CONTACT WITH SKIN,
EYES AND CLOTHING. WASH HANDS THOROUGHLY AFTER HANDLING.

GENERAL INDUSTRIAL HYGIENE PRACTICE.

HANDLING (PHYSICAL ASPECTS): NO APPLICABLE DATA AVAILABLE.

DUST EXPLOSION CLASS: NO APPLICABLE DATA AVAILABLE.

STORAGE:
NO SPECIAL STORAGE CONDITIONS REQUIRED. KEEP CONTAINER CLOSED TO PREVENT
CONTAMINATION.

NO DECOMPOSITION IF STORED AND APPLIED AS DIRECTED.

STORAGE PERIOD: NO APPLICABLE DATA AVAILABLE.

STORAGE TEMPERATURE: NO APPLICABLE DATA AVAILABLE.


SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION 


ENGINEERING CONTROLS:
IN THE EVENT THAT THE POLYMER IS HEATED ABOVE 350 DEG. C (662 DEG. F),
LOCAL VENTILATION SHOULD BE USED TO AVOID EXPOSURE TO FUMES.

PERSONAL PROTECTIVE EQUIPMENT:

RESPIRATORY PROTECTION:
NO PERSONAL RESPIRATORY PROTECTIVE EQUIPMENT NORMALLY REQUIRED. IN THE CASE
OF HAZARDOUS FUMES CAUSED BY OVERHEATING, WEAR SELF-CONTAINED BREATHING
APPARATUS.

HAND PROTECTION:
ADDITIONAL PROTECTION: IMPERVIOUS GLOVES

EYE PROTECTION: SAFETY GLASSES

SKIN AND BODY PROTECTION:
NO PPE IS SPECIFIED HOWEVER, AVOID CONTACT WITH SKIN, EYES, AND CLOTHING.

PREVENTIVE SKIN PROTECTION:

EXPOSURE GUIDELINES:

EXPOSURE LIMIT VALUES:

FLUOROCOMPOUND: NO APPLICABLE DATA AVAILABLE.

THIS PRODUCT DOES NOT CONTAIN ANY EXPOSURE LIMITS THAT REQUIRE DISCLOSURE
ACCORDING TO OSHA HAZARD COMMUNICATION STANDARD 2012.


SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES 


APPEARANCE:

PHYSICAL STATE: LIQUID

FORM: VISCOUS LIQUID

COLOR: CLEAR, AMBER, DARK GREY

ODOR: NONE

ODOR THRESHOLD: NO APPLICABLE DATA AVAILABLE.

PH: ACIDIC

MELTING POINT/RANGE: NO APPLICABLE DATA AVAILABLE.

BOILING POINT/BOILING RANGE: NO APPLICABLE DATA AVAILABLE.

FLASH POINT:
METHOD: PENSKY-MARTENS OPEN CUP - PMOC DOES NOT FLASH

EVAPORATION RATE: NO APPLICABLE DATA AVAILABLE.

FLAMMABILITY (SOLID, GAS): NO APPLICABLE DATA AVAILABLE.

UPPER EXPLOSION LIMIT: NO APPLICABLE DATA AVAILABLE.
LOWER EXPLOSION LIMIT: NO APPLICABLE DATA AVAILABLE.

VAPOUR PRESSURE: NO APPLICABLE DATA AVAILABLE.

VAPOUR DENSITY: NO APPLICABLE DATA AVAILABLE.

SPECIFIC GRAVITY (RELATIVE DENSITY): CA. 1.9

WATER SOLUBILITY: INSOLUBLE

SOLUBILITY(IES): NO APPLICABLE DATA AVAILABLE.

PARTITION COEFFICIENT N-OCTANOL/WATER: NO APPLICABLE DATA AVAILABLE.

AUTO-IGNITION TEMPERATURE: NO APPLICABLE DATA AVAILABLE.

DECOMPOSITION TEMPERATURE: 170 - 200 DEG. C

VISCOSITY, KINEMATIC: NO APPLICABLE DATA AVAILABLE.

VISCOSITY: NO APPLICABLE DATA AVAILABLE.


SECTION 10. STABILITY AND REACTIVITY 


REACTIVITY: STABLE UNDER RECOMMENDED STORAGE CONDITIONS.

CHEMICAL STABILITY: STABLE UNDER NORMAL CONDITIONS.

POSSIBILITY OF HAZARDOUS REACTIONS: NO APPLICABLE DATA AVAILABLE.

CONDITIONS TO AVOID:
TEMPERATURE: >350 DEG. C (>662 DEG. F)

INCOMPATIBLE MATERIALS: NO APPLICABLE DATA AVAILABLE.

HAZARDOUS DECOMPOSITION PRODUCTS:
HAZARDOUS THERMAL DECOMPOSITION PRODUCTS: FLUORINATED COMPOUNDS


SECTION 11. TOXICOLOGICAL INFORMATION 


FLUOROCOMPOUND:

DERMAL LD50: >5,000 MG/KG, RAT

ORAL LD50: >5,000 MG/KG, RAT

ORAL LD50: >5,000 MG/KG, MOUSE

SKIN IRRITATION: SLIGHT IRRITATION, RABBIT

EYE IRRITATION: MILD EYE IRRITATION, RABBIT

SKIN SENSITIZATION: CAUSES SENSITISATION., MOUSE

REPEATED DOSE TOXICITY:
ORAL - GAVAGE
RAT

NOAEL: 1,000 MG/KG
NO TOXICOLOGICALLY SIGNIFICANT EFFECTS WERE FOUND.

MUTAGENICITY:
TESTS ON BACTERIAL OR MAMMALIAN CELL CULTURES DID NOT SHOW MUTAGENIC
EFFECTS.

CARCINOGENICITY:
THE CARCINOGENICITY CLASSIFICATIONS FOR THIS PRODUCT AND/OR ITS INGREDIENTS
HAVE BEEN DETERMINED ACCORDING TO HAZCOM 2012, APPENDIX A.6. THE
CLASSIFICATIONS MAY DIFFER FROM THOSE LISTED IN THE NATIONAL TOXICOLOGY
PROGRAM (NTP) REPORT ON CARCINOGENS (LATEST EDITION) OR THOSE FOUND TO BE
A POTENTIAL CARCINOGEN IN THE INTERNATIONAL AGENCY FOR RESEARCH ON CANCER
(IARC) MONOGRAPHS (LATEST EDITION).

NONE OF THE COMPONENTS PRESENT IN THIS MATERIAL AT CONCENTRATIONS EQUAL TO
OR GREATER THAN 0.1% ARE LISTED BY IARC, NTP, OR OSHA, AS A CARCINOGEN.


SECTION 12. ECOLOGICAL INFORMATION 


ADDITIONAL ECOLOGICAL INFORMATION:
NO DATA IS AVAILABLE ON THE PRODUCT ITSELF.


SECTION 13. DISPOSAL CONSIDERATIONS 


WASTE DISPOSAL METHODS - PRODUCT:
IN ACCORDANCE WITH LOCAL AND NATIONAL REGULATIONS.

CONTAMINATED PACKAGING:
DISPOSE OF CONTAINER PROPERLY.

IF RECYCLING IS NOT PRACTICABLE, DISPOSE OF IN COMPLIANCE WITH LOCAL
REGULATIONS.


SECTION 14. TRANSPORT INFORMATION 


NOT CLASSIFIED AS DANGEROUS IN THE MEANING OF TRANSPORT REGULATIONS.


SECTION 15. REGULATORY INFORMATION 


TSCA: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY

CALIFORNIA PROP. 65:
CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS
OR ANY OTHER HARM: NONE KNOWN


SECTION 16. OTHER INFORMATION 


RESTRICTIONS FOR USE:
DO NOT USE DUPONT MATERIALS IN MEDICAL APPLICATIONS INVOLVING IMPLANTATION
IN THE HUMAN BODY OR CONTACT WITH INTERNAL BODY FLUIDS OR TISSUES UNLESS
THE MATERIAL HAS BEEN PROVIDED FROM DUPONT UNDER A WRITTEN CONTRACT THAT IS
CONSISTENT WITH DUPONT POLICY REGARDING MEDICAL APPLICATIONS AND EXPRESSLY
ACKNOWLEDGES THE CONTEMPLATED USE. FOR FURTHER INFORMATION, PLEASE CONTACT
YOUR DUPONT REPRESENTATIVE. YOU MAY ALSO REQUEST A COPY OF THE DUPONT
POLICY REGARDING MEDICAL APPLICATIONS AND DUPONT CAUTION REGARDING MEDICAL
APPLICATIONS.

DUPONT(TM) AND KRYTOX(R*) ARE TRADEMARKS OF E. I. DU PONT DE NEMOURS AND
COMPANY

REVISION DATE: 04/03/2015

CONTACT PERSON:
MSDS COORDINATOR, DUPONT CHEMICALS AND FLUOROPRODUCTS, WILMINGTON, DE
19898, (800) 441-7515

THE INFORMATION PROVIDED IN THIS SAFETY DATA SHEET IS CORRECT TO THE BEST
OF OUR KNOWLEDGE, INFORMATION AND BELIEF AT THE DATE OF ITS PUBLICATION.
THE INFORMATION GIVEN IS DESIGNED ONLY AS A GUIDANCE FOR SAFE HANDLING,
USE, PROCESSING, STORAGE, TRANSPORTATION, DISPOSAL AND RELEASE AND IS NOT
TO BE CONSIDERED A WARRANTY OR QUALITY SPECIFICATION. THE INFORMATION
RELATES ONLY TO THE SPECIFIC MATERIAL DESIGNATED AND MAY NOT BE VALID FOR
SUCH MATERIAL USED IN COMBINATION WITH ANY OTHER MATERIALS OR IN ANY
PROCESS, UNLESS SPECIFIED IN THE TEXT.

SIGNIFICANT CHANGE FROM PREVIOUS VERSION IS DENOTED WITH A DOUBLE BAR.