SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. DUPONT(R*) SAFETY DATA SHEET DUPONT(TM) KRYTOX(R*) 157FS OILS VERSION: 0.0 REVISION DATE: 04/03/2015 REF.: 150000002944 THIS SDS ADHERES TO THE STANDARDS AND REGULATORY REQUIREMENTS OF THE UNITED STATES AND MAY NOT MEET THE REGULATORY REQUIREMENTS IN OTHER COUNTRIES.
PRODUCT NAME: DUPONT(TM) KRYTOX(R*) 157FS OILS TRADENAME/SYNONYM: FLUOROGUARD FSM PRODUCT GRADE/TYPE: 157: FSL, FSM, FSH PRODUCT USE: LUBRICANT, FOR INDUSTRIAL USE ONLY. RESTRICTIONS ON USE: DO NOT USE PRODUCT FOR ANYTHING OUTSIDE OF THE ABOVE SPECIFIED USES MANUFACTURER/SUPPLIER: DUPONT 1007 MARKET STREET WILMINGTON, DE 19898 UNITED STATES OF AMERICA PRODUCT INFORMATION: 1-800-441-7515 (OUTSIDE THE U.S. 1-302-774-1000) MEDICAL EMERGENCY: 1-800-441-3637 (OUTSIDE THE U.S. 1-302-774-1139) TRANSPORT EMERGENCY: CHEMTREC: +1-800-424-9300 (OUTSIDE THE U.S. +1-703-527-3887) OTHER INFORMATION: PROFESSIONAL USE
PRODUCT HAZARD CATEGORY: SERIOUS EYE DAMAGE/EYE IRRITATION: CATEGORY 2B SKIN SENSITISATION: CATEGORY 1 LABEL CONTENT: PICTOGRAM: EXCLAMATION MARK SIGNAL WORD: WARNING HAZARDOUS WARNINGS: MAY CAUSE AN ALLERGIC SKIN REACTION. CAUSES EYE IRRITATION. HAZARDOUS PREVENTION MEASURES: AVOID BREATHING DUST/FUME/GAS/MIST/VAPOURS/SPRAY. WASH SKIN THOROUGHLY AFTER HANDLING. CONTAMINATED WORK CLOTHING SHOULD NOT BE ALLOWED OUT OF THE WORKPLACE. WEAR PROTECTIVE GLOVES. IF ON SKIN: WASH WITH PLENTY OF SOAP AND WATER. IF IN EYES: RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES. REMOVE CONTACT LENSES, IF PRESENT AND EASY TO DO. CONTINUE RINSING. IF SKIN IRRITATION OR RASH OCCURS: GET MEDICAL ADVICE/ATTENTION. IF EYE IRRITATION PERSISTS: GET MEDICAL ADVICE/ATTENTION. WASH CONTAMINATED CLOTHING BEFORE REUSE. DISPOSE OF CONTENTS/CONTAINER TO AN APPROVED WASTE DISPOSAL PLANT. OTHER HAZARDS: REPEATED OR PROLONGED SKIN CONTACT MAY CAUSE ALLERGIC REACTIONS WITH SUSCEPTIBLE PERSONS., INHALATION OF DECOMPOSITION PRODUCTS FROM OVERHEATING MAY CAUSE LUNG IRRITATION OR SHORTNESS OF BREATH.
COMPONENT CAS-NO. CONCENTRATION FLUOROCOMPOUND 100%
GENERAL ADVICE: WHEN SYMPTOMS PERSIST OR IN ALL CASES OF DOUBT SEEK MEDICAL ADVICE. INHALATION: MOVE TO FRESH AIR IN CASE OF ACCIDENTAL INHALATION OF FUMES FROM OVERHEATING OR COMBUSTION. SKIN CONTACT: WASH OFF WITH SOAP AND PLENTY OF WATER. EYE CONTACT: RINSE WITH PLENTY OF WATER. IF EYE IRRITATION PERSISTS, CONSULT A SPECIALIST. INGESTION: NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO NOT INDUCE VOMITING UNLESS DIRECTED TO DO SO BY A PHYSICIAN OR POISON CONTROL CENTER. MOST IMPORTANT SYMPTOMS/EFFECTS, ACUTE AND DELAYED: NO APPLICABLE DATA AVAILABLE. PROTECTION OF FIRST-AIDERS: IF POTENTIAL FOR EXPOSURE EXISTS REFER TO SECTION 8 FOR SPECIFIC PERSONAL PROTECTIVE EQUIPMENT. NOTES TO PHYSICIAN: NO APPLICABLE DATA AVAILABLE.
SUITABLE EXTINGUISHING MEDIA: THE PRODUCT ITSELF DOES NOT BURN. USE EXTINGUISHING MEASURES THAT ARE APPROPRIATE TO LOCAL CIRCUMSTANCES AND THE SURROUNDING ENVIRONMENT. UNSUITABLE EXTINGUISHING MEDIA: NO APPLICABLE DATA AVAILABLE. SPECIFIC HAZARDS: IN FIRE CONDITIONS, TOXIC DECOMPOSITION PRODUCTS MAY BE FORMED. (SEE ALSO SECTION 10) SPECIAL PROTECTIVE EQUIPMENT FOR FIREFIGHTERS: WEAR SELF-CONTAINED BREATHING APPARATUS (SCBA). WEAR SUITABLE PROTECTIVE EQUIPMENT. FURTHER INFORMATION: STANDARD PROCEDURE FOR CHEMICAL FIRES.
NOTE: REVIEW FIRE FIGHTING MEASURES AND HANDLING (PERSONNEL) SECTIONS BEFORE PROCEEDING WITH CLEAN-UP USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT DURING CLEAN-UP. SAFEGUARDS (PERSONNEL): NO APPLICABLE DATA AVAILABLE. ENVIRONMENTAL PRECAUTIONS: PREVENT MATERIAL FROM ENTERING SEWERS, WATERWAYS, OR LOW AREAS. SPILL CLEANUP: SOAK UP WITH INERT ABSORBENT MATERIAL (E.G. SAND, SILICA GEL, ACID BINDER, UNIVERSAL BINDER, SAWDUST). ACCIDENTAL RELEASE MEASURES: NO APPLICABLE DATA AVAILABLE.
HANDLING (PERSONNEL): AVOID BREATHING VAPORS FROM OVERHEATED MATERIAL. AVOID CONTACT WITH SKIN, EYES AND CLOTHING. WASH HANDS THOROUGHLY AFTER HANDLING. GENERAL INDUSTRIAL HYGIENE PRACTICE. HANDLING (PHYSICAL ASPECTS): NO APPLICABLE DATA AVAILABLE. DUST EXPLOSION CLASS: NO APPLICABLE DATA AVAILABLE. STORAGE: NO SPECIAL STORAGE CONDITIONS REQUIRED. KEEP CONTAINER CLOSED TO PREVENT CONTAMINATION. NO DECOMPOSITION IF STORED AND APPLIED AS DIRECTED. STORAGE PERIOD: NO APPLICABLE DATA AVAILABLE. STORAGE TEMPERATURE: NO APPLICABLE DATA AVAILABLE.
ENGINEERING CONTROLS: IN THE EVENT THAT THE POLYMER IS HEATED ABOVE 350 DEG. C (662 DEG. F), LOCAL VENTILATION SHOULD BE USED TO AVOID EXPOSURE TO FUMES. PERSONAL PROTECTIVE EQUIPMENT: RESPIRATORY PROTECTION: NO PERSONAL RESPIRATORY PROTECTIVE EQUIPMENT NORMALLY REQUIRED. IN THE CASE OF HAZARDOUS FUMES CAUSED BY OVERHEATING, WEAR SELF-CONTAINED BREATHING APPARATUS. HAND PROTECTION: ADDITIONAL PROTECTION: IMPERVIOUS GLOVES EYE PROTECTION: SAFETY GLASSES SKIN AND BODY PROTECTION: NO PPE IS SPECIFIED HOWEVER, AVOID CONTACT WITH SKIN, EYES, AND CLOTHING. PREVENTIVE SKIN PROTECTION: EXPOSURE GUIDELINES: EXPOSURE LIMIT VALUES: FLUOROCOMPOUND: NO APPLICABLE DATA AVAILABLE. THIS PRODUCT DOES NOT CONTAIN ANY EXPOSURE LIMITS THAT REQUIRE DISCLOSURE ACCORDING TO OSHA HAZARD COMMUNICATION STANDARD 2012.
APPEARANCE: PHYSICAL STATE: LIQUID FORM: VISCOUS LIQUID COLOR: CLEAR, AMBER, DARK GREY ODOR: NONE ODOR THRESHOLD: NO APPLICABLE DATA AVAILABLE. PH: ACIDIC MELTING POINT/RANGE: NO APPLICABLE DATA AVAILABLE. BOILING POINT/BOILING RANGE: NO APPLICABLE DATA AVAILABLE. FLASH POINT: METHOD: PENSKY-MARTENS OPEN CUP - PMOC DOES NOT FLASH EVAPORATION RATE: NO APPLICABLE DATA AVAILABLE. FLAMMABILITY (SOLID, GAS): NO APPLICABLE DATA AVAILABLE. UPPER EXPLOSION LIMIT: NO APPLICABLE DATA AVAILABLE. LOWER EXPLOSION LIMIT: NO APPLICABLE DATA AVAILABLE. VAPOUR PRESSURE: NO APPLICABLE DATA AVAILABLE. VAPOUR DENSITY: NO APPLICABLE DATA AVAILABLE. SPECIFIC GRAVITY (RELATIVE DENSITY): CA. 1.9 WATER SOLUBILITY: INSOLUBLE SOLUBILITY(IES): NO APPLICABLE DATA AVAILABLE. PARTITION COEFFICIENT N-OCTANOL/WATER: NO APPLICABLE DATA AVAILABLE. AUTO-IGNITION TEMPERATURE: NO APPLICABLE DATA AVAILABLE. DECOMPOSITION TEMPERATURE: 170 - 200 DEG. C VISCOSITY, KINEMATIC: NO APPLICABLE DATA AVAILABLE. VISCOSITY: NO APPLICABLE DATA AVAILABLE.
REACTIVITY: STABLE UNDER RECOMMENDED STORAGE CONDITIONS. CHEMICAL STABILITY: STABLE UNDER NORMAL CONDITIONS. POSSIBILITY OF HAZARDOUS REACTIONS: NO APPLICABLE DATA AVAILABLE. CONDITIONS TO AVOID: TEMPERATURE: >350 DEG. C (>662 DEG. F) INCOMPATIBLE MATERIALS: NO APPLICABLE DATA AVAILABLE. HAZARDOUS DECOMPOSITION PRODUCTS: HAZARDOUS THERMAL DECOMPOSITION PRODUCTS: FLUORINATED COMPOUNDS
FLUOROCOMPOUND: DERMAL LD50: >5,000 MG/KG, RAT ORAL LD50: >5,000 MG/KG, RAT ORAL LD50: >5,000 MG/KG, MOUSE SKIN IRRITATION: SLIGHT IRRITATION, RABBIT EYE IRRITATION: MILD EYE IRRITATION, RABBIT SKIN SENSITIZATION: CAUSES SENSITISATION., MOUSE REPEATED DOSE TOXICITY: ORAL - GAVAGE RAT NOAEL: 1,000 MG/KG NO TOXICOLOGICALLY SIGNIFICANT EFFECTS WERE FOUND. MUTAGENICITY: TESTS ON BACTERIAL OR MAMMALIAN CELL CULTURES DID NOT SHOW MUTAGENIC EFFECTS. CARCINOGENICITY: THE CARCINOGENICITY CLASSIFICATIONS FOR THIS PRODUCT AND/OR ITS INGREDIENTS HAVE BEEN DETERMINED ACCORDING TO HAZCOM 2012, APPENDIX A.6. THE CLASSIFICATIONS MAY DIFFER FROM THOSE LISTED IN THE NATIONAL TOXICOLOGY PROGRAM (NTP) REPORT ON CARCINOGENS (LATEST EDITION) OR THOSE FOUND TO BE A POTENTIAL CARCINOGEN IN THE INTERNATIONAL AGENCY FOR RESEARCH ON CANCER (IARC) MONOGRAPHS (LATEST EDITION). NONE OF THE COMPONENTS PRESENT IN THIS MATERIAL AT CONCENTRATIONS EQUAL TO OR GREATER THAN 0.1% ARE LISTED BY IARC, NTP, OR OSHA, AS A CARCINOGEN.
ADDITIONAL ECOLOGICAL INFORMATION: NO DATA IS AVAILABLE ON THE PRODUCT ITSELF.
WASTE DISPOSAL METHODS - PRODUCT: IN ACCORDANCE WITH LOCAL AND NATIONAL REGULATIONS. CONTAMINATED PACKAGING: DISPOSE OF CONTAINER PROPERLY. IF RECYCLING IS NOT PRACTICABLE, DISPOSE OF IN COMPLIANCE WITH LOCAL REGULATIONS.
NOT CLASSIFIED AS DANGEROUS IN THE MEANING OF TRANSPORT REGULATIONS.
TSCA: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY CALIFORNIA PROP. 65: CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR ANY OTHER HARM: NONE KNOWN
RESTRICTIONS FOR USE: DO NOT USE DUPONT MATERIALS IN MEDICAL APPLICATIONS INVOLVING IMPLANTATION IN THE HUMAN BODY OR CONTACT WITH INTERNAL BODY FLUIDS OR TISSUES UNLESS THE MATERIAL HAS BEEN PROVIDED FROM DUPONT UNDER A WRITTEN CONTRACT THAT IS CONSISTENT WITH DUPONT POLICY REGARDING MEDICAL APPLICATIONS AND EXPRESSLY ACKNOWLEDGES THE CONTEMPLATED USE. FOR FURTHER INFORMATION, PLEASE CONTACT YOUR DUPONT REPRESENTATIVE. YOU MAY ALSO REQUEST A COPY OF THE DUPONT POLICY REGARDING MEDICAL APPLICATIONS AND DUPONT CAUTION REGARDING MEDICAL APPLICATIONS. DUPONT(TM) AND KRYTOX(R*) ARE TRADEMARKS OF E. I. DU PONT DE NEMOURS AND COMPANY REVISION DATE: 04/03/2015 CONTACT PERSON: MSDS COORDINATOR, DUPONT CHEMICALS AND FLUOROPRODUCTS, WILMINGTON, DE 19898, (800) 441-7515 THE INFORMATION PROVIDED IN THIS SAFETY DATA SHEET IS CORRECT TO THE BEST OF OUR KNOWLEDGE, INFORMATION AND BELIEF AT THE DATE OF ITS PUBLICATION. THE INFORMATION GIVEN IS DESIGNED ONLY AS A GUIDANCE FOR SAFE HANDLING, USE, PROCESSING, STORAGE, TRANSPORTATION, DISPOSAL AND RELEASE AND IS NOT TO BE CONSIDERED A WARRANTY OR QUALITY SPECIFICATION. THE INFORMATION RELATES ONLY TO THE SPECIFIC MATERIAL DESIGNATED AND MAY NOT BE VALID FOR SUCH MATERIAL USED IN COMBINATION WITH ANY OTHER MATERIALS OR IN ANY PROCESS, UNLESS SPECIFIED IN THE TEXT. SIGNIFICANT CHANGE FROM PREVIOUS VERSION IS DENOTED WITH A DOUBLE BAR. |