Common Name: CARBON MONOXIDE IN AIR 0.0001% TO 0.0999%
Manufacturer: NORLAB
SDS Revision Date: 5/28/2015
SDS Format: No Format Specified
   
Item Number(s): 35ZD09, 35ZD15
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1 PRODUCT AND COMPANY IDENTIFICATION 
2 HAZARDS IDENTIFICATION 
3 COMPOSITION / INFORMATION ON INGREDIENTS 
4 FIRST AID MEASURES 
5 FIRE FIGHTING MEASURES 
6 ACCIDENTAL RELEASE MEASURES 
7 HANDLING AND STORAGE 
8 EXPOSURE CONTROLS/PERSONAL PROTECTION 
9 PHYSICAL AND CHEMICAL PROPERTIES 
10 STABILITY AND REACTIVITY 
11 TOXICOLOGICAL INFORMATION 
12 ECOLOGICAL INFORMATION 
13 DISPOSAL CONSIDERATIONS 
14 TRANSPORT INFORMATION 
15 REGULATORY INFORMATION 
16 OTHER INFORMATION 



NORLAB
A DIVISION OF NORCO, INC.

SAFETY DATA SHEET (SDS)

NORLAB - A DIVISION OF NORCO, INC.

CARBON MONOXIDE IN AIR 0.0001% TO 0.0999%

SDS NUMBER: 2060

REVISION DATE: 5/28/2015


1 PRODUCT AND COMPANY IDENTIFICATION 


MANUFACTURER:
NORLAB - A DIVISION OF NORCO, INC.
898 W. GOWEN RD.
BOISE, ID 83705

CONTACT: QUALITY DEPARTMENT

PHONE: (208) 336-1643

WEB: WWW.NORLAB-GAS.COM

PRODUCT NAME: CARBON MONOXIDE IN AIR 0.0001% TO 0.0999%

REVISION DATE: 5/28/2015

VERSION: 1

SDS NUMBER: 2060

COMMON NAME: CARBON MONOXIDE IN AIR

CAS NUMBER: MIXTURE

CHEMICAL FAMILY: GAS MIXTURE

CHEMICAL FORMULA: CO 0.0001% TO 0.0999% IN AIR

SYNONYMS: GAS MIXTURE, CAL. GAS, 2

EMERGENCY TELEPHONE NUMBER: (800) 424-9300 (CHEMTREC)


2 HAZARDS IDENTIFICATION 


INHALATION:
DEPENDING ON THE CONCENTRATION OF THE CARBON MONOXIDE PRESENT, THIS PRODUCT
MAY ACT AS A SIMPLE ASPHYXIATE OR A CHEMICAL ASPHYXIATE. THIS MIXTURE
CONTAINS SUFFICIENT OXYGEN TO SUPPORT LIFE.

INHALED CARBON MONOXIDE BINDS WITH BLOOD HEMOGLOBIN TO FORM
CARBOXYHEMOGLOBIN. CARBOXYHEMOGLOBIN CANNOT TAKE PART IN NORMAL OXYGEN
TRANSPORT, GREATLY REDUCING THE BLOOD'S ABILITY TO TRANSPORT OXYGEN.
DEPENDING ON LEVELS AND DURATION OF EXPOSURE, SYMPTOMS MAY INCLUDE
HEADACHE, DIZZINESS, HEART PALPITATIONS, WEAKNESS, CONFUSION, NAUSEA,
AND EVEN CONVULSIONS, EVENTUAL UNCONSCIOUSNESS AND DEATH.

SOME EXPERIMENTAL EVIDENCE INDICATES TERATOGENIC AND REPRODUCTIVE EFFECTS.

SKIN CONTACT:
CONTACT WITH RAPIDLY EXPANDING GAS NEAR THE POINT OF RELEASE MAY CAUSE
FROSTBITE WITH REDNESS, SKIN COLOR CHANGE TO GRAY OR WHITE, AND BLISTERING.

EYE CONTACT:
CONTACT WITH RAPIDLY EXPANDING GAS NEAR THE POINT OF RELEASE MAY CAUSE
FROSTBITE.

INGESTION: NONE KNOWN. INGESTION IS UNLIKELY.

NFPA:
HEALTH     1
FIRE       0
REACTIVITY 0

HMIS III:
H  1
F  0
PH 3

NFPA:
HEALTH          1
FIRE HAZARD     0
REACTIVITY      0
SPECIFIC HAZARD

HMIS III:
HEALTH              1
FLAMMABILITY        0
PHYSICAL HAZARDS    3
PERSONAL PROTECTION B SAFETY GLASSES, GLOVES

PERSONAL PROTECTION INDEX:

A SAFETY GLASSES

B
SAFETY GLASSES
GLOVES

C
SAFETY GLASSES
GLOVES
APRON

D
FACE SHIELD
GLOVES
APRON

E
SAFETY GLASSES
GLOVES
DUST RESPIRATOR

F
SAFETY GLASSES
GLOVES
APRON
DUST RESPIRATOR

G
SAFETY GLASSES
GLOVES
VAPOR RESPIRATOR

H
SPLASH GOGGLES
GLOVES
APRON
VAPOR RESPIRATOR

I
SAFETY GOGGLES
GLOVES
DUST AND VAPOR RESPIRATOR

J
SPLASH GOGGLES
GLOVES
APRON
DUST AND VAPOR RESPIRATOR

K
AIR-LINE HOOD OR MASK
GLOVES
FULL SUIT
BOOTS

X CONSULT YOUR SUPERVISOR OR S.O.P. FOR SPECIAL HANDLING DIRECTIONS

A SAFETY GLASSES

N SPLASH GOGGLES

O FACE SHIELD & EYE PROTECTION

P GLOVES

Q BOOTS

R SYNTHETIC APRON

S FULL SUIT

T DUST RESPIRATOR

U VAPOR RESPIRATOR

W DUST & VAPOR RESPIRATOR

Y FULL FACE RESPIRATOR

Z AIRLINE HOOD OR MASK

GHS SIGNAL WORD: WARNING

GHS HAZARD PICTOGRAMS: GAS CYLINDER

GHS CLASSIFICATIONS:
PHYSICAL, GASES UNDER PRESSURE, COMPRESSED GAS
HEALTH, ACUTE TOXICITY, 5 INHALATION

GHS PHRASES:
H280: CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED
H333: MAY BE HARMFUL IF INHALED
CGA-HG24: SUPPORTS COMBUSTION

GHS PRECAUTIONARY STATEMENTS:
P260: DO NOT BREATHE DUST/FUME/GAS/MIST/VAPORS/SPRAY.

P271: USE ONLY OUTDOORS OR IN A WELL-VENTILATED AREA.

P304+312:
IN INHALED: CALL A POISON CENTER OR DOCTOR/PHYSICIAN IF YOU FEEL UNWELL.

P304+340:
IF INHALED:
REMOVE VICTIM TO FRESH AIR AND KEEP AT REST IN A POSITION COMFORTABLE FOR
BREATHING.

P403+233: STORE IN A WELL VENTILATED PLACE. KEEP CONTAINER TIGHTLY CLOSED.

CGA-PG02:
PROTECT FROM SUNLIGHT WHEN AMBIENT TEMPERATURE EXCEEDS 52 DEG. C (125 DEG.
F).

CGA-PG05: USE A BACK FLOW PREVENTIVE DEVICE IN THE PIPING

CGA-PG06: CLOSE VALVE AFTER EACH USE AND WHEN EMPTY.

CGA-PG10: USE ONLY WITH EQUIPMENT RATED FOR CYLINDER PRESSURE.

CGA-PG20: USE ONLY EQUIPMENT OF COMPATIBLE MATERIALS OF CONSTRUCTIONS.

NON-FLAMMABLE, COLORLESS, ODORLESS GAS. CARBON MONOXIDE ACTS AS A CHEMICAL
ASPHYXIATE, BINDING TO THE BLOOD HEMOGLOBIN, GREATLY REDUCING THE RED BLOOD
CELL'S ABILITY TO TRANSPORT OXYGEN TO BODY TISSUES. EFFECTS MAY INCLUDE
HEADACHES, DIZZINESS, CONVULSIONS, LOSS OF CONSCIOUSNESS AND DEATH.
CONTENTS UNDER PRESSURE. USE AND STORE BELOW 125 DEG. F (52 DEG. C).


3 COMPOSITION / INFORMATION ON INGREDIENTS 


INGREDIENTS:

CAS #     PERCENTAGE         CHEMICAL NAME

N/A       99.9001-99.9999%   AIR

630-08-0   0.0001-0.0999%    CARBON MONOXIDE


4 FIRST AID MEASURES 


INHALATION:
PROMPT MEDICAL ATTENTION IS MANDATORY IN ALL CASES OF OVEREXPOSURE TO THIS
PRODUCT. RESCUE PERSONNEL SHOULD BE EQUIPPED WITH SELF-CONTAINED BREATHING
APPARATUS. CONSCIOUS PERSONS SHOULD BE ASSISTED TO AN UNCONTAMINATED AREA
AND BE TREATED WITH SUPPLEMENTAL OXYGEN. QUICK REMOVAL FROM THE
CONTAMINATED AREA IS MOST IMPORTANT. UNCONSCIOUS PERSONS SHOULD BE MOVED TO
AN UNCONTAMINATED AREA AND BE GIVEN ARTIFICIAL RESPIRATION AND OXYGEN AT
THE SAME TIME. ADMINISTRATION OF 100% OXYGEN BY TIGHT FITTING FACE MASK
REDUCES THE BIOLOGICAL HALF-LIFE OF CO.

FOR SEVERELY POISONED PATIENTS, HYPERBARIC OXYGEN THERAPY SHOULD BE
CONSIDERED. THE ADMINISTERING OF THE OXYGEN AT AN ELEVATED PRESSURE (UP TO
2 TO 2.5 ATMOSPHERES) HAS SHOWN TO BE BENEFICIAL AS HAS TREATMENT IN A
HYPERBARIC CHAMBER. THE PHYSICIAN SHOULD BE INFORMED THAT THE PATIENT HAS
INHALED TOXIC QUANTITIES OF CARBON MONOXIDE.

SKIN CONTACT:
NONE REQUIRED FOR GAS. FOR FROSTBITE, IMMERSE SKIN IN LUKEWARM WATER. DO
NOT USE HOT WATER. OBTAIN MEDICAL ATTENTION.

EYE CONTACT:
NEVER INTRODUCE OINTMENT OR OIL INTO THE EYES WITHOUT MEDICAL ADVICE!
REMOVE VICTIM FROM THE SOURCE OF CONTAMINATION. FLUSH EYES WITH WATER FOR
15 MINUTES. IF PAIN IS PRESENT, REFER THE VICTIM TO AN OPHTHALMOLOGIST FOR
TREATMENT AND FOLLOW UP. IF THE VICTIM CANNOT TOLERATE LIGHT, PROTECT THE
EYES WITH A LIGHT BANDAGE. IF FROSTBITE IS SUSPECTED, FLUSH WITH COOL WATER
FOR 15 MINUTES AND OBTAIN IMMEDIATE MEDICAL ATTENTION.

INGESTION: NONE ANTICIPATED; PRODUCT IS A GAS.

MOST IMPORTANT SYMPTOMS AND EFFECTS, BOTH ACUTE AND DELAYED:
THE MOST IMPORTANT KNOWN SYMPTOMS AND EFFECTS ARE DESCRIBED IN THE LABELING
(SEE SECTION 2) AND/OR SECTION 11.

INDICATION OF ANY IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT NEEDED:
NO DATA AVAILABLE.


5 FIRE FIGHTING MEASURES 


FLAMMABILITY: NOT FLAMMABLE

FLASH POINT: NA

FLASH POINT METHOD: NA

BURNING RATE: NOT DETERMINED

AUTOIGNITION TEMP: NOT DETERMINED

LEL: 12.5% (CO)
UEL: 74.0% (CO)

EXTINGUISHING MEDIA: USE AS APPROPRIATE FOR SURROUNDING MATERIAL.

SPECIAL HAZARDS ARISING FROM THE SUBSTANCE OR MIXTURE:
CARBON OXIDES
NITROGEN GAS
NITROGEN OXIDES (NOx)
OXYGEN GAS

ADVICE FOR FIREFIGHTERS:
IF POSSIBLE, STOP THE FLOW OF GAS SUPPLY. CONTINUE TO COOL HEAT OR FLAME
EXPOSED CONTAINERS UNTIL WELL AFTER THE FLAMES ARE EXTINGUISHED.
FIREFIGHTERS SHOULD WEAR A FULL-FACE PIECE, NIOSH/MSHA-APPROVED
SELF-CONTAINED BREATHING APPARATUS (SCBA) OPERATED IN POSITIVE PRESSURE
MODE AND FULL TURNOUT GEAR.

FURTHER INFORMATION:

IF INCINERATED, MAY RELEASE TOXIC FUMES.

USE WATER SPRAY TO COOL UNOPENED CONTAINERS.

PRODUCT IS NON-FLAMMABLE. CONCENTRATION OF CARBON MONOXIDE IS BELOW THE IEI
OF 12.5% IN AIR. THIS GAS MIXTURE CONTAINS SUFFICIENT OXYGEN TO SUPPORT
COMBUSTION.

CYLINDERS MAY RUPTURE VIOLENTLY FROM PRESSURE WHEN INVOLVED IN A FIRE
SITUATION.

SEE SECTION 7 FOR MORE INFORMATION ON SAFE HANDLING.

SEE SECTION 8 FOR MORE INFORMATION ON PERSONAL PROTECTION EQUIPMENT.

SEE SECTION 13 FOR DISPOSAL INFORMATION.


6 ACCIDENTAL RELEASE MEASURES 


PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:
EVACUATE ALL PERSONNEL FROM AFFECTED AREA. USE APPROPRIATE PROTECTIVE
EQUIPMENT. IF LEAK IS IN USER'S EQUIPMENT, BE CERTAIN TO PURGE PIPING WITH
INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN CONTAINER OR VALVE,
CONTACT THE APPROPRIATE EMERGENCY TELEPHONE NUMBER LISTED IN SECTION 1 OR
CALL YOUR CLOSEST NORCO/NORLAB LOCATION.

ENVIRONMENTAL PRECAUTIONS:
PREVENT FURTHER RELEASE (LEAKAGE/SPILLAGE) IF SAFE TO DO SO.

METHODS AND MATERIALS FOR CONTAINMENTS AND CLEANING UP:
CONTACT THE APPROPRIATE EMERGENCY TELEPHONE NUMBER LISTED IN SECTION 1 OR
CALL YOUR CLOSEST NORCO/NORIAB LOCATION. ENSURE ADEQUATE VENTILATION.

REFERENCE TO OTHER SECTIONS:
SEE SECTION 7 FOR INFORMATION ON SAFE HANDLING.
SEE SECTION 8 FOR INFORMATION ON PERSONAL PROTECTION EQUIPMENT.
SEE SECTION 13 FOR INFORMATION ON PROPER DISPOSAL.


7 HANDLING AND STORAGE 


HANDLING PRECAUTIONS:

CARBON MONOXIDE CAN BE HANDLED IN ALL COMMONLY USED METALS UP TO
APPROXIMATELY 500 PSIG (3450 KPA). ABOVE THAT PRESSURE IT FORMS TOXIC AND
CORROSIVE CARBONYL COMPOUNDS WITH SOME METALS. CARBON STEELS, ALUMINUM
ALLOYS, COPPER AND COPPER ALLOYS, LOW CARBON STAINLESS STEELS AND
NICKEL-BASED ALLOYS SUCH AS HASTELLOY A, B & C ARE RECOMMENDED FOR HIGHER
PRESSURE APPLICATIONS.

USE ONLY IN WELL-VENTILATED AREAS. VALVE PROTECTION CAPS MUST REMAIN IN
PLACE UNLESS CONTAINER IS SECURED WITH VALVE OUTLET PIPED TO USE POINT. DO
NOT DRAG, SLIDE OR ROLL CYLINDERS. USE A SUITABLE HAND TRUCK FOR CYLINDER
MOVEMENT. USE A PRESSURE REDUCING REGULATOR WHEN CONNECTING CYLINDER TO
LOWER PRESSURE (<3000 PSIG) PIPING SYSTEMS. DO NOT HEAT CYLINDER BY ANY
MEANS TO INCREASE THE DISCHARGE RATE OF PRODUCT FROM THE CYLINDER. USE A
CHECK VALVE OR TRAP IN THE DISCHARGE LINE TO PREVENT HAZARDOUS BACKFLOW
INTO THE CYLINDER.

NEVER CARRY A COMPRESSED GAS CYLINDER OR A CONTAINER OF A GAS IN CRYOGENIC
LIQUID FROM IN AN ENCLOSED SPACE SUCH AS A CAR TRUNK, VAN OR STATION WAGON.
A LEAK CAN RESULT IN A FIRE, EXPLOSION, ASPHYXIATION OR A TOXIC EXPOSURE.

STORAGE REQUIREMENTS:

ENSURE ADEQUATE VENTILATION.

PROTECT CYLINDERS FROM PHYSICAL DAMAGE. STORE IN A COOL, DRY, WELL
VENTILATED AREA OF NON-COMBUSTIBLE CONSTRUCTION AWAY FROM HEAVY TRAFFIC
AREAS AND EMERGENCY EXITS. DO NOT ALLOW THE TEMPERATURE WHERE CYLINDERS ARE
STORED TO EXCEED 125 DEG. F (52 DEG. C). CYLINDERS SHOULD BE STORED UPRIGHT
AND FIRMLY SECURED TO PREVENT FALLING OR BEING KNOCKED OVER. FULL AND EMPTY
CYLINDERS SHOULD BE SEGREGATED. USE A "FIRST IN - FIRST OUT" INVENTORY
SYSTEM TO PREVENT FULL CYLINDERS FROM BEING STORED FOR EXCESSIVE PERIODS OF
TIME.

FOR ADDITIONAL RECOMMENDATIONS, CONSULT COMPRESSED GAS ASSOCIATION PAMPHLET
P-1.


8 EXPOSURE CONTROLS/PERSONAL PROTECTION 


ENGINEERING CONTROLS:
ALL VENTILATION SHOULD BE DESIGNED IN ACCORDANCE WITH OSHA STANDARD (29 CFR
1910.94). USE LOCAL EXHAUST AT FILLING ZONES AND WHERE LEAKAGE AND DUST
FORMATION IS PROBABLE. USE MECHANICAL (GENERAL) VENTILATION FOR STORAGE
AREAS. USE APPROPRIATE VENTILATION AS REQUIRED TO KEEP EXPOSURE LIMITS IN
AIR BELOW TLV & PEL LIMITS.

PERSONAL PROTECTIVE EQUIP:

EYE/FACE PROTECTION:
WHEN USING MATERIAL USE A VAPOR RESPIRATOR ACCORDING TO HMIS PP, U. ALL
SAFETY EQUIPMENT SHOULD BE TESTED AND APPROVED UNDER APPROPRIATE GOVERNMENT
STANDARDS SUCH AS NIOSH (US) OR EN 166 (EU).

SKIN PROTECTION:
NOT REQUIRED, BUT MAY BE USED. GLOVES MUST BE INSPECTED PRIOR TO USE.
DISPOSE OF CONTAMINATED GLOVES ACCORDING TO APPLICABLE LAWS AND WORKPLACE
PRACTICES.

BODY PROTECTION:
NOT REQUIRED, BUT MAY BE USED. TYPE OF PROTECTIVE EQUIPMENT SHOULD BE
SELECTED BASED ON CONCENTRATION AMOUNT AND CONDITIONS OF USE OF THIS
MATERIAL. USE SAFETY SHOES.

RESPIRATORY PROTECTION:
USE OF A VAPOR RESPIRATOR IS RECOMMENDED. A VAPOR RESPIRATOR MAY BE
REQUIRED AS BACKUP TO ENGINEERING CONTROLS WHEN PROPER ENGINEERING CONTROLS
ARE NOT IN PLACE TO KEEP TLV AND PEL LIMITS BELOW DEFINED THRESHOLDS. A
NIOSH/MSHA-APPROVED FULL-FACE PIECE SCBA OPERATED IN POSITIVE MODE AND/OR
ANY SUPPLIED AIR RESPIRATOR WITH A FULL-FACE PIECE AND OPERATED IN A
POSITIVE PRESSURE MODE IN COMBINATION WITH AN AUXILIARY SELF CONTAINED
BREATHING APPARATUS OPERATED IN POSITIVE PRESSURE MODE SHOULD BE USED FOR
HIGH OR UNKNOWN CONCENTRATIONS. RESPIRATORS SHOULD BE STORED IN AN AREA NOT
LIKELY TO BE CONTAMINATED.

CONTROL OF ENVIRONMENTAL EXPOSURE:
PREVENT LEAKAGE OR SPILLAGE IF SAFE TO DO SO.

COMPONENTS WITH WORKPLACE CONTROL PARAMETERS:

COMPONENT(S): AIR; CARBON MONOXIDE

CAS NO(S): N/A; 630-08-0

USA NIOSH (TWA/REL): 35 PPM, 40 MG/M3

USA NIOSH (C/REL): 35 PPM, 27 MG/M3

USA ACGIH (TWA/TLV): 25 PPM

USA OSHA OCCUPATIONAL EXPOSURE LIMITS TABLE Z-1 LIMITS FOR AIR CONTAMINANT
(TWA): 50 PPM, 55 MG/M3

BIOLOGICAL OCCUPATIONAL EXPOSURE LIMITS:

COMPONENT: CARBON MONOXIDE

CAS-NO: 630-08-0

PARAMETERS: CARBOXYHEMOGLOBIN; CARBON MONOXIDE

BIOLOGICAL SPECIMEN: IN BLOOD; IN END-EXHALED AIR

USA ACGIH BIOLOGICAL EXPOSURE INDICES: 3.5%; 20.0 PPM


9 PHYSICAL AND CHEMICAL PROPERTIES 


APPEARANCE: CLEAR, COLORLESS GAS

PHYSICAL STATE: GAS

ODOR THRESHOLD: NOT DETERMINED

PARTICLE SIZE: NOT DETERMINED

SPEC GRAV./DENSITY: NO DATA AVAILABLE

VISCOSITY: NOT DETERMINED

SAT. VAP. CONC.: NOT DETERMINED

BOILING POINT: NOT DETERMINED

FLAMMABILITY:
(SOLID, GAS): NOT FLAMMABLE

PARTITION COEFFICIENT: NOT DETERMINED

VAPOR PRESSURE: NOT DETERMINED

PH: NOT DETERMINED

EVAP. RATE: NOT DETERMINED

MOLECULAR WEIGHT: MIXTURE

DECOMP TEMP: NOT DETERMINED

ODOR: ODORLESS

MOLECULAR FORMULA: MIXTURE

SOLUBILITY: VERY SLIGHT

SOFTENING POINT: NOT DETERMINED

PERCENT VOLATILE: 100%

HEAT VALUE: NOT DETERMINED

FREEZING/MELTING PT.: NOT DETERMINED

FLASH POINT: NOT DETERMINED

OCTANOL: NOT DETERMINED

VAPOR DENSITY (AIR = 1): NOT DETERMINED

VOC: NOT DETERMINED

BULK DENSITY: NA

AUTO-IGNITION TEMP: NOT DETERMINED

LFL/UFL (% V/V): 12.5 / 74.0 (CO)


10 STABILITY AND REACTIVITY 


STABILITY: PRODUCT IS STABLE UNDER NORMAL CONDITIONS.

CONDITIONS TO AVOID: INCOMPATIBILITIES, FLAMES, IGNITION SOURCES.

MATERIALS TO AVOID:
STRONG OXIDIZING AGENTS, SODIUM/SODIUM OXIDES, POTASSIUM.

HAZARDOUS DECOMPOSITION: CARBON OXIDES AND NITROGEN OXIDES (NOx).

HAZARDOUS POLYMERIZATION: WILL NOT OCCUR.


11 TOXICOLOGICAL INFORMATION 


COMPONENT(S): AIR; CARBON MONOXIDE

CAS NO(S): N/A; 630-08-0

ACUTE TOXICITY:
LC50 INHALATION - RAT: 1,807 PPM (4 H)

SKIN CORROSION/IRRITATION: NO DATA AVAILABLE.

SERIOUS EYE DAMAGE/EYE IRRITATION: NO DATA AVAILABLE.

RESPIRATORY OR SKIN SENSITIZATION: NO DATA AVAILABLE.

GERM CELL MUTAGENICITY:
GENETIC CHANGES OBSERVED IN MAMMALIAN CELL ASSAY SYSTEMS AT EXPOSURES OF
1500 TO 2500 PPM FOR 10 MINUTES.

CARCINOGENICITY:

IARC:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY IARC.

ACGIH:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY ACGIH.

NTP:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY NTP.

OSHA:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY OSHA.

REPRODUCTIVE TOXICITY:
INHALATION OF 150 PPM OF CARBON MONOXIDE FOR 24 HOURS BY PREGNANT RATS
PRODUCED CARDIOVASCULAR AND BEHAVIORAL DEFECTS IN OFFSPRING. TOXIC EFFECTS
TO FERTILITY WERE OBSERVED IN FEMALE RATS EXPOSED TO 1 MG/M3 FOR 24 HOURS.
SIMILAR EFFECTS WERE OBSERVED FOR OTHER MAMMALIAN SPECIES.

SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE: NO DATA AVAILABLE.

SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE:
INHALATION - CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED
EXPOSURE.

ASPIRATION HAZARD: NO DATA AVAILABLE.

ADDITIONAL INFORMATION:

COMPONENT: AIR

RTECS: N/A

COMPONENT: CARBON MONOXIDE

RTECS: FG3500000


12 ECOLOGICAL INFORMATION 


COMPONENT(S): AIR; CARBON MONOXIDE

CAS NO(S): N/A; 630-08-0

TOXICITY:
TOXICITY TO FISH: NO DATA AVAILABLE.

TOXICITY TO DAPHNIA AND OTHER AQUATIC INVERTEBRATES: NO DATA AVAILABLE.

PERSISTENCE AND DEGRADABILITY: NO DATA AVAILABLE.

BIOACCUMULATIVE POTENTIAL: NO DATA AVAILABLE.

MOBILITY IN SOIL: NO DATA AVAILABLE.

RESULTS OF PBT AND VPVB ASSESSMENT: NOT REQUIRED/CONDUCTED.

OTHER ADVERSE EFFECTS:
AN ENVIRONMENTAL HAZARD CANNOT BE EXCLUDED IN THE EVENT OF UNPROFESSIONAL
HANDLING OR DISPOSAL. PRODUCT DOES NOT CONTAIN CLASS I OR CLASS II OZONE
DEPLETING SUBSTANCES.


13 DISPOSAL CONSIDERATIONS 


PRODUCT AND CONTAMINATED PACKAGING:
DO NOT ATTEMPT TO DISPOSE OF RESIDUAL WASTE OR UNUSED QUANTITIES IN
RETURNABLE CONTAINERS. RETURN IN THE SHIPPING CONTAINER, PROPERLY LABELED,
WITH ANY VALVE OUTLET PLUGS OR CAPS SECURE AND VALVE PROTECTION CAP IN
PLACE TO NORLAB FOR PROPER DISPOSAL. NON-REFILLABLE CONTAINERS SHOULD BE
VENTED IN A WELL-VENTILATED AREA THEN DISPOSED OF IN COMPLIANCE WITH LOCAL
REGULATIONS, OR RETURNED TO NORLAB.


14 TRANSPORT INFORMATION 


DOT CLASS: NON-FLAMMABLE GAS (2.2) #2.2

UN #: UN 1956

CLASS: 2

PROPER SHIPPING NAME: COMPRESSED GAS, N.O.S. (CARBON MONOXIDE, NITROGEN)

DOT (US):
UN NUMBER: 1956
CLASS: 2.2
ERG #: 126
PROPER SHIPPING NAME: COMPRESSED GAS, N.O.S. (CARBON MONOXIDE, NITROGEN)

IMDG:
UN NUMBER: 1956
CLASS: 2.2
EMS-NO: F-C, S-V
PROPER SHIPPING NAME: COMPRESSED GAS, N.O.S. (CARBON MONOXIDE, NITROGEN)

IATA:
UN NUMBER: 1956
CLASS: 2.2
PROPER SHIPPING NAME: COMPRESSED GAS, N.O.S. (CARBON MONOXIDE, NITROGEN)

CANADA TDG:
UN NUMBER: 1956
CLASS: 2.2
PROPER SHIPPING NAME: COMPRESSED GAS, N.O.S. (CARBON MONOXIDE, NITROGEN)

CLASS 2.2, NON-FLAMMABLE AND NON-TOXIC GASES


15 REGULATORY INFORMATION 


COMPONENT         (CAS/PERC)               CODES

*AIR              (N/A 99.9001-99.9999%)   MASS, NJHS, PA, SARA 311/312,
                                           TSCA

*CARBON MONOXIDE  (630080 0.0001-0.0999%)  MASS, NJEHS, NJHS, OSHAWAC, PA,
                                           PROP 65, SARA 311/312, TSCA,
                                           TXAIR

REGULATORY KEY DESCRIPTIONS:
MASS: MA MASSACHUSETTS HAZARDOUS SUBSTANCES LIST
NJEHS: NJ EXTRAORDINARILY HAZARDOUS SUBSTANCES
NJHS: NJ RIGHT-TO-KNOW HAZARDOUS SUBSTANCES
OSHAWAC: OSHA WORKPLACE AIR CONTAMINANTS
PA: PA RIGHT-TO-KNOW LIST OF HAZARDOUS SUBSTANCES
PROP 65: CA PROP 65
SARA 311/312: SARA 311/312 TOXIC CHEMICALS
TSCA: TOXIC SUBSTANCES CONTROL ACT
TXAIR: TX AIR CONTAMINANTS WITH HEALTH EFFECTS SCREENING LEVEL


16 OTHER INFORMATION 


DISCLAIMER:
THE DATA IN THIS SAFETY DATA SHEET RELATES ONLY TO THE SPECIFIC MATERIAL
DESIGNATED HEREIN AND DOES NOT RELATE TO USE IN COMBINATION WITH ANY OTHER
MATERIAL IN ANY PROCESS. THE INFORMATION SET FORTH HEREIN IS FURNISHED FREE
OF CHARGE AND IS BASED ON TECHNICAL DATA THAT NORLAB BELIEVES TO BE
RELIABLE. IT IS INTENDED FOR USE BY PERSONS HAVING TECHNICAL SKILL AND AT
THEIR OWN DISCRETION AND RISK. SINCE CONDITIONS OF USE ARE OUTSIDE OF
NORLAB'S CONTROL, NORLAB MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, AND
ASSUMES NO LIABILITY IN CONNECTION WITH ANY USE OF THIS INFORMATION.
NOTHING HEREIN IS TO BE TAKEN AS A LICENSE TO OPERATE UNDER, OR A
RECOMMENDATION TO INFRINGE UPON, ANY PATENTS.