Common Name: GE5070
Manufacturer: MOMENTIVE PERFORMANCE MATERIALS
SDS Revision Date: 7/28/2016
SDS Format: GHS-US
   
Item Number(s): 3LA49
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1. IDENTIFICATION 
2. HAZARD(S) IDENTIFICATION 
3. COMPOSITION/INFORMATION ON INGREDIENTS 
4. FIRST-AID MEASURES 
5. FIRE-FIGHTING MEASURES 
6. ACCIDENTAL RELEASE MEASURES 
7. HANDLING AND STORAGE 
8. EXPOSURE CONTROLS/PERSONAL PROTECTION 
9. PHYSICAL AND CHEMICAL PROPERTIES 
10. STABILITY AND REACTIVITY 
11. TOXICOLOGICAL INFORMATION 
12. ECOLOGICAL INFORMATION 
13. DISPOSAL CONSIDERATIONS 
14. TRANSPORT INFORMATION 
15. REGULATORY INFORMATION 
16. OTHER INFORMATION, INCLUDING DATE OF PREPARATION 



MOMENTIVE(TM)

GE5070

SAFETY DATA SHEET

VERSION: 1.10

REVISION DATE: 07/28/2016


1. IDENTIFICATION 


PRODUCT IDENTIFIER: GE5070

OTHER MEANS OF IDENTIFICATION:

SYNONYMS: SILICONE SEALANT

RECOMMENDED USE AND RESTRICTION ON USE:

RECOMMENDED USE: SILICONE ELASTOMER

RESTRICTIONS ON USE: NOT KNOWN.

MANUFACTURER/IMPORTER/DISTRIBUTOR INFORMATION:
MOMENTIVE PERFORMANCE MATERIALS LLC
260 HUDSON RIVER ROAD
WATERFORD, NY 12188

CONTACT PERSON: COMMERCIAL.SERVICES@MOMENTIVE.COM

TELEPHONE:
GENERAL INFORMATION: +1-800-295-2392

EMERGENCY TELEPHONE NUMBER:

SUPPLIER:
CHEMTREC: 1-800-424-9300


2. HAZARD(S) IDENTIFICATION 


HAZARD CLASSIFICATION:

HEALTH HAZARDS:
SKIN CORROSION/IRRITATION: CATEGORY 2
SERIOUS EYE DAMAGE/EYE IRRITATION: CATEGORY 2A
SKIN SENSITIZER: CATEGORY 1
TOXIC TO REPRODUCTION: CATEGORY 1B

LABEL ELEMENTS:

HAZARD SYMBOL:
HEALTH HAZARD
EXCLAMATION MARK

SIGNAL WORD: NO SIGNAL WORD.

HAZARD STATEMENT:
CAUSES SERIOUS EYE IRRITATION.
CAUSES SKIN IRRITATION.
MAY CAUSE AN ALLERGIC SKIN REACTION.
MAY DAMAGE FERTILITY OR THE UNBORN CHILD.

PRECAUTIONARY STATEMENT:

PREVENTION:
OBTAIN SPECIAL INSTRUCTIONS BEFORE USE. DO NOT HANDLE UNTIL ALL SAFETY
PRECAUTIONS HAVE BEEN READ AND UNDERSTOOD. USE PERSONAL PROTECTIVE
EQUIPMENT AS REQUIRED. WEAR PROTECTIVE GLOVES. WEAR EYE PROTECTION/FACE
PROTECTION. AVOID BREATHING DUST. WASH HANDS THOROUGHLY AFTER HANDLING.
CONTAMINATED WORK CLOTHING SHOULD NOT BE ALLOWED OUT OF THE WORKPLACE.

RESPONSE:
IF EXPOSED OR CONCERNED: GET MEDICAL ADVICE/ATTENTION.

IF ON SKIN:
WASH WITH PLENTY OF WATER.
TAKE OFF CONTAMINATED CLOTHING.
WASH CONTAMINATED CLOTHING BEFORE REUSE.

IF SKIN IRRITATION OR RASH OCCURS:

IF IN EYES:
RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES. REMOVE CONTACT LENSES, IF
PRESENT AND EASY TO DO. CONTINUE RINSING.

IF EYE IRRITATION PERSISTS:

STORAGE: STORE LOCKED UP.

DISPOSAL:
DISPOSE OF CONTENTS/CONTAINER TO AN APPROPRIATE TREATMENT AND DISPOSAL
FACILITY IN ACCORDANCE WITH APPLICABLE LAWS AND REGULATIONS, AND PRODUCT
CHARACTERISTICS AT TIME OF DISPOSAL.

OTHER HAZARDS WHICH DO NOT RESULT IN GHS CLASSIFICATION: NONE.


3. COMPOSITION/INFORMATION ON INGREDIENTS 


MIXTURES:

CHEMICAL IDENTITY         CAS NUMBER   CONTENT IN      NOTES
                                       PERCENT (%)*

DISTILLATES, PETROLEUM,   64742-46-7     7 - 13%       # THIS SUBSTANCE
HYDROTREATED MIDDLE                                    HAS WORKPLACE
                                                       EXPOSURE LIMIT(S).

HEXAMETHYLDISILAZANE        999-97-3     1 - 5%        NO DATA AVAILABLE.

TITANIUM DIOXIDE          13463-67-7     1 - 5%        # THIS SUBSTANCE
                                                       HAS WORKPLACE
                                                       EXPOSURE LIMIT(S).

DIBUTYL TIN BIS           22673-19-4   0.1 - 1% #      THIS SUBSTANCE
ACETYLACETONATE                                        HAS WORKPLACE
                                                       EXPOSURE LIMIT(S).

SILICA                     7631-86-9   0.1 - 1%        # THIS SUBSTANCE
                                                       HAS WORKPLACE
                                                       EXPOSURE LIMIT(S).

* ALL CONCENTRATIONS ARE PERCENT BY WEIGHT UNLESS INGREDIENT IS A GAS.
GAS CONCENTRATIONS ARE IN PERCENT BY VOLUME.

THE RESPIRABLE PARTICLE(S) LISTED ABOVE ARE INEXTRICABLY BOUND WITHIN THE
POLYMER MATRIX, AND THEREFORE DOES NOT PRESENT AN INHALATION HAZARD DURING
NORMAL USE OF THIS PRODUCT. TOOLING OR MACHINING OF THE CURED PRODUCT
(SANDING, CUTTING, MILLING) MAY RELEASE HAZARDOUS, RESPIRABLE SUBSTANCES.


4. FIRST-AID MEASURES 


INGESTION: IF SWALLOWED, DO NOT INDUCE VOMITING. GIVE A GLASS OF WATER.

INHALATION:
IF INHALED, REMOVE TO FRESH AIR. IF NOT BREATHING GIVE ARTIFICIAL
RESPIRATION USING A BARRIER DEVICE. IF BREATHING IS DIFFICULT GIVE OXYGEN.
GET MEDICAL ATTENTION.

SKIN CONTACT:
TO CLEAN FROM SKIN, REMOVE COMPLETELY WITH A DRY CLOTH OR PAPER TOWEL,
BEFORE WASHING WITH DETERGENT AND WATER.

IF SKIN IRRITATION OCCURS: GET MEDICAL ADVICE/ATTENTION.

EYE CONTACT:
IN CASE OF CONTACT WITH EYES, RINSE IMMEDIATELY WITH PLENTY OF WATER AND
SEEK MEDICAL ADVICE.

MOST IMPORTANT SYMPTOMS/EFFECTS, ACUTE AND DELAYED:
SYMPTOMS: TREATMENT IS SYMPTOMATIC AND SUPPORTIVE.
HAZARDS: NO DATA AVAILABLE.

INDICATION OF IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT NEEDED:
TREATMENT: NO DATA AVAILABLE.


5. FIRE-FIGHTING MEASURES 


GENERAL FIRE HAZARDS: NO DATA AVAILABLE.

SUITABLE (AND UNSUITABLE) EXTINGUISHING MEDIA:

SUITABLE EXTINGUISHING MEDIA:
ALL STANDARD EXTINGUISHING AGENTS ARE SUITABLE.

UNSUITABLE EXTINGUISHING MEDIA: NO DATA AVAILABLE.

SPECIFIC HAZARDS ARISING FROM THE CHEMICAL: NO DATA AVAILABLE.

SPECIAL PROTECTIVE EQUIPMENT AND PRECAUTIONS FOR FIREFIGHTERS:

SPECIAL FIRE FIGHTING PROCEDURES: NO DATA AVAILABLE.

SPECIAL PROTECTIVE EQUIPMENT FOR FIRE-FIGHTERS:
FIREFIGHTERS MUST WEAR NIOSH/MSHA APPROVED POSITIVE PRESSURE SELF-CONTAINED
BREATHING APPARATUS WITH FULL FACE MASK AND FULL PROTECTIVE CLOTHING.


6. ACCIDENTAL RELEASE MEASURES 


PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:
AVOID CONTACT WITH SKIN AND EYES. KEEP OUT OF REACH OF CHILDREN. KEEP
CONTAINER TIGHTLY CLOSED. ADEQUATE VENTILATION SHOULD BE PROVIDED SO THAT
EXPOSURE LIMITS ARE NOT EXCEEDED.

METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP:
WIPE, SCRAPE OR SOAK UP IN AN INERT MATERIAL AND PUT IN A CONTAINER FOR
DISPOSAL. WASH WALKING SURFACES WITH DETERGENT AND WATER TO REDUCE SLIPPING
HAZARD. WEAR PROPER PROTECTIVE EQUIPMENT AS SPECIFIED IN THE PROTECTIVE
EQUIPMENT SECTION.


7. HANDLING AND STORAGE 


PRECAUTIONS FOR SAFE HANDLING:
SENSITIVITY TO STATIC DISCHARGE IS NOT EXPECTED.

CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES:
NO DATA AVAILABLE.


8. EXPOSURE CONTROLS/PERSONAL PROTECTION 


CONTROL PARAMETERS:

OCCUPATIONAL EXPOSURE LIMITS:

CHEMICAL IDENTITY         TYPE   EXPOSURE       SOURCE
                                 LIMIT VALUES

DISTILLATES, PETROLEUM,   TWA    5 MG/M3        US. ACGIH THRESHOLD LIMIT
HYDROTREATED MIDDLE -                           VALUES (03 2015)
INHALABLE FRACTION.

DISTILLATES, PETROLEUM,   REL    5 MG/M3        US. NIOSH:
HYDROTREATED MIDDLE -                           POCKET GUIDE TO CHEMICAL
MIST.                                           HAZARDS (2010)

                          STEL   10 MG/M3       US. NIOSH:
                                                POCKET GUIDE TO CHEMICAL
                                                HAZARDS (2010)

                          PEL    5 MG/M3        US. OSHA TABLE Z-1 LIMITS
                                                FOR AIR CONTAMINANTS (29
                                                CFR 1910.1000) (02 2006)

                          TWA    5 MG/M3        US. OSHA TABLE Z-1-A (29
                                                CFR 1910.1000) (1989)

TITANIUM DIOXIDE          TWA    10 MG/M3       US. ACGIH THRESHOLD LIMIT
                                                VALUES (03 2015)

TITANIUM DIOXIDE - TOTAL  PEL    15 MG/M3       US. OSHA TABLE Z-1 LIMITS
DUST.                                           FOR AIR CONTAMINANTS (29
                                                CFR 1910.1000) (02 2006)

                          TWA    10 MG/M3       US. OSHA TABLE Z-1-A (29
                                                CFR 1910.1000) (1989)

DIBUTYL TIN BIS           STEL   0.2 MG/M3      US. ACGIH THRESHOLD LIMIT
ACETYLACETONATE - AS Sn                         VALUES (03 2015)

                          TWA    0.1 MG/M3      US. ACGIH THRESHOLD LIMIT
                                                VALUES (03 2015)

                          REL    0.1 MG/M3      US. NIOSH:
                                                POCKET GUIDE TO CHEMICAL
                                                HAZARDS (2010)

                          PEL    0.1 MG/M3      US. OSHA TABLE Z-1 LIMITS
                                                FOR AIR CONTAMINANTS (29
                                                CFR 1910.1000) (02 2006)

                          TWA    0.1 MG/M3      US. OSHA TABLE Z-1-A (29
                                                CFR 1910.1000) (1989)

SILICA                    REL    6 MG/M3        US. NIOSH:
                                                POCKET GUIDE TO CHEMICAL
                                                HAZARDS (2010)

                          TWA    6 MG/M3        US. OSHA TABLE Z-1-A (29
                                                CFR 1910.1000) (1989)

                          TWA    20 MILLIONS    US. OSHA TABLE Z-3 (29 CFR
                                 OF PARTICLES   1910.1000) (2000)
                                 PER CUBIC
                                 FOOT OF AIR

                          TWA    0.8 MG/M3      US. OSHA TABLE Z-3 (29 CFR
                                                1910.1000) (2000)

THIS PRODUCT CONTAINS ONE OR MORE SUBSTANCES WITH AN OCCUPATIONAL EXPOSURE
LIMIT. HOWEVER, THE RESPIRABLE PARTICLE(S) OF THIS/THESE SUBSTANCE(S) ARE
INEXTRICABLY BOUND WITHIN THE POLYMER MATRIX. THEREFORE, WE DO NOT EXPECT
AN EXPOSURE TO THIS/THESE SUBSTANCE(S) DURING NORMAL USE OF THIS PRODUCT.
TOOLING OR MACHINING OF THE CURED PRODUCT (SANDING, CUTTING, MILLING) MAY
RELEASE HAZARDOUS, RESPIRABLE SUBSTANCES.

APPROPRIATE ENGINEERING CONTROLS:
EYE WASH FACILITIES AND EMERGENCY SHOWER MUST BE AVAILABLE WHEN HANDLING
THIS PRODUCT.

INDIVIDUAL PROTECTION MEASURES, SUCH AS PERSONAL PROTECTIVE EQUIPMENT:

GENERAL INFORMATION:
VENTILATION AND OTHER FORMS OF ENGINEERING CONTROLS ARE PREFERRED FOR
CONTROLLING EXPOSURES. RESPIRATORY PROTECTION MAY BE NEEDED FOR NON-ROUTINE
OR EMERGENCY SITUATIONS.

EYE/FACE PROTECTION: SAFETY GLASSES WITH SIDE SHIELDS

SKIN PROTECTION:

HAND PROTECTION: CLOTH GLOVES.

OTHER: WEAR SUITABLE PROTECTIVE CLOTHING AND EYE/FACE PROTECTION.

RESPIRATORY PROTECTION:
IF EXPOSURE LIMITS ARE EXCEEDED OR RESPIRATORY IRRITATION IS EXPERIENCED,
NIOSH/MSHA APPROVED RESPIRATORY PROTECTION SHOULD BE WORN. SUPPLIED AIR
RESPIRATORS MAY BE REQUIRED FOR NON-ROUTINE OR EMERGENCY SITUATIONS.
RESPIRATORY PROTECTION MUST BE PROVIDED IN ACCORDANCE WITH OSHA REGULATIONS
(SEE 29CFR 1910.134).

HYGIENE MEASURES: NO DATA AVAILABLE.


9. PHYSICAL AND CHEMICAL PROPERTIES 


APPEARANCE:

PHYSICAL STATE: SOLID

FORM: SOLID

COLOR: WHITE

ODOR: AMMONIA.

ODOR THRESHOLD: NO DATA AVAILABLE.

PH: NOT APPLICABLE

MELTING POINT/FREEZING POINT: NOT APPLICABLE

INITIAL BOILING POINT AND BOILING RANGE: NOT APPLICABLE

FLASH POINT: >93.3 DEG. C (ESTIMATED)

EVAPORATION RATE: NO DATA AVAILABLE.

FLAMMABILITY (SOLID, GAS): NO DATA AVAILABLE.

UPPER/LOWER LIMIT ON FLAMMABILITY OR EXPLOSIVE LIMITS:
FLAMMABILITY LIMIT - UPPER (%): NO DATA AVAILABLE.
FLAMMABILITY LIMIT - LOWER (%): NO DATA AVAILABLE.

EXPLOSIVE LIMIT - UPPER (%): NO DATA AVAILABLE.
EXPLOSIVE LIMIT - LOWER (%): NO DATA AVAILABLE.

VAPOR PRESSURE: NOT APPLICABLE

VAPOR DENSITY: NO DATA AVAILABLE.

DENSITY: NO DATA AVAILABLE.

RELATIVE DENSITY: 1.02

SOLUBILITY(IES):
SOLUBILITY IN WATER: INSOLUBLE
SOLUBILITY (OTHER): PARTIAL IN TOLUENE

PARTITION COEFFICIENT (N-OCTANOL/WATER) LOG POW: NO DATA AVAILABLE.

AUTO-IGNITION TEMPERATURE: NO DATA AVAILABLE.

DECOMPOSITION TEMPERATURE: NO DATA AVAILABLE.

SADT: NO DATA AVAILABLE.

VISCOSITY, DYNAMIC: NO DATA AVAILABLE.

VISCOSITY, KINEMATIC: NO DATA AVAILABLE.

VOC: 27 G/L


10. STABILITY AND REACTIVITY 


REACTIVITY: NO DATA AVAILABLE.

CHEMICAL STABILITY: NO DATA AVAILABLE.

POSSIBILITY OF HAZARDOUS REACTIONS:
HAZARDOUS POLYMERISATION DOES NOT OCCUR.

CONDITIONS TO AVOID: NONE KNOWN.

INCOMPATIBLE MATERIALS: NONE KNOWN.

HAZARDOUS DECOMPOSITION PRODUCTS:
CARBON DIOXIDE AMMONIA. SILICON DIOXIDE. MEASUREMENTS AT TEMPERATURES
ABOVE 150 DEG. C IN PRESENCE OF AIR (OXYGEN) HAVE SHOWN THAT SMALL AMOUNTS
OF FORMALDEHYDE ARE FORMED DUE TO OXIDATIVE DEGRADATION.


11. TOXICOLOGICAL INFORMATION 


INFORMATION ON LIKELY ROUTES OF EXPOSURE:
INGESTION: NO DATA AVAILABLE.
INHALATION: NO DATA AVAILABLE.
SKIN CONTACT: NO DATA AVAILABLE.
EYE CONTACT: NO DATA AVAILABLE.

SYMPTOMS RELATED TO THE PHYSICAL, CHEMICAL AND TOXICOLOGICAL
CHARACTERISTICS:
INGESTION: NO DATA AVAILABLE.
INHALATION: NO DATA AVAILABLE.
SKIN CONTACT: NO DATA AVAILABLE.
EYE CONTACT: NO DATA AVAILABLE.

INFORMATION ON TOXICOLOGICAL EFFECTS:

ACUTE TOXICITY (LIST ALL POSSIBLE ROUTES OF EXPOSURE):

ORAL:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):

HEXAMETHYLDISILAZANE:
LD50 (RAT): 870 MG/KG

TITANIUM DIOXIDE:
LD50 (RAT): >10,000 MG/KG

SILICA:
LD50 (RAT): >15,000 MG/KG

DERMAL:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):

TITANIUM DIOXIDE:
LD50 (RABBIT): >10,000 MG/KG

INHALATION:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):

TITANIUM DIOXIDE:
LC50 (RAT): >6.8 MG/L

REPEATED DOSE TOXICITY:
PRODUCT: NO DATA AVAILABLE.

SKIN CORROSION/IRRITATION:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):
HEXAMETHYLDISILAZANE: NO DATA AVAILABLE.
(RABBIT): CORROSIVE

SPECIFIED SUBSTANCE(S):
SILICA:
(RABBIT): NO SKIN IRRITATION

SERIOUS EYE DAMAGE/EYE IRRITATION:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):
TITANIUM DIOXIDE: NO EYE IRRITATION

RESPIRATORY OR SKIN SENSITIZATION:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):
TITANIUM DIOXIDE: NEGATIVE

CARCINOGENICITY:
PRODUCT: NO DATA AVAILABLE.

IARC MONOGRAPHS ON THE EVALUATION OF CARCINOGENIC RISKS TO HUMANS:

TITANIUM DIOXIDE:
OVERALL EVALUATION: 2B. POSSIBLY CARCINOGENIC TO HUMANS.

US. NATIONAL TOXICOLOGY PROGRAM (NTP) REPORT ON CARCINOGENS:
NO CARCINOGENIC COMPONENTS IDENTIFIED

US. OSHA SPECIFICALLY REGULATED SUBSTANCES (29 CFR 1910.1001-1050):
NO CARCINOGENIC COMPONENTS IDENTIFIED

GERM CELL MUTAGENICITY:

IN VITRO:
PRODUCT: NO DATA AVAILABLE.

IN VIVO:
PRODUCT: NO DATA AVAILABLE.

REPRODUCTIVE TOXICITY:
PRODUCT: NO DATA AVAILABLE.

SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE:
PRODUCT: NO DATA AVAILABLE.

SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE:
PRODUCT: NO DATA AVAILABLE.

ASPIRATION HAZARD:
PRODUCT: NO DATA AVAILABLE.

OTHER EFFECTS:
CONTAINS DIBUTYLTIN COMPOUND(S) - MAY IMPAIR FERTILITY. MAY CAUSE HARM TO
UNBORN CHILD.


12. ECOLOGICAL INFORMATION 


ECOTOXICITY:

ACUTE HAZARDS TO THE AQUATIC ENVIRONMENT:

FISH:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):

TITANIUM DIOXIDE:
LC0 (LEUCISCUS IDUS, 48 H): >1,000 MG/L

SILICA:
LC0 (BRACHYDANIO RERIO, 96 H): 5,000 MG/L

AQUATIC INVERTEBRATES:
PRODUCT: NO DATA AVAILABLE.

CHRONIC HAZARDS TO THE AQUATIC ENVIRONMENT:

FISH:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):

SILICA:
LC0 (BRACHYDANIO RERIO, 4 D): 5,000 MG/L

AQUATIC INVERTEBRATES:
PRODUCT: NO DATA AVAILABLE.

TOXICITY TO AQUATIC PLANTS:
PRODUCT: NO DATA AVAILABLE.

PERSISTENCE AND DEGRADABILITY:

BIODEGRADATION:
PRODUCT: NO DATA AVAILABLE.

SPECIFIED SUBSTANCE(S):
TITANIUM DIOXIDE: 0%

BOD/COD RATIO:
PRODUCT: NO DATA AVAILABLE.

BIOACCUMULATIVE POTENTIAL:

BIOCONCENTRATION FACTOR (BCF):
PRODUCT: NO DATA AVAILABLE.

PARTITION COEFFICIENT N-OCTANOL / WATER (LOG KOW):
PRODUCT: NO DATA AVAILABLE.

MOBILITY IN SOIL: NO DATA AVAILABLE.

KNOWN OR PREDICTED DISTRIBUTION TO ENVIRONMENTAL COMPARTMENTS:
DISTILLATES, PETROLEUM, HYDROTREATED MIDDLE: NO DATA AVAILABLE.
HEXAMETHYLDISILAZANE: NO DATA AVAILABLE.
TITANIUM DIOXIDE: NO DATA AVAILABLE.
DIBUTYL TIN BIS ACETYLACETONATE: NO DATA AVAILABLE.
SILICA: NO DATA AVAILABLE.

KNOWN OR PREDICTED DISTRIBUTION TO ENVIRONMENTAL COMPARTMENTS:
METHYLPOLYSILOXANE: NO DATA AVAILABLE.

SILANE, DICHLORODIMETHYL-, REAKTION PRODUCTS WITH SILICA, SILANE,
DICHLORODIMETHYL-, REACTION PRODUCTS WITH SILICA: NO DATA AVAILABLE.

SILOXANES AND SILICONES, DI-ME: NO DATA AVAILABLE.

OTHER ADVERSE EFFECTS: NO DATA AVAILABLE.


13. DISPOSAL CONSIDERATIONS 


DISPOSAL INSTRUCTIONS:
DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REGULATIONS.

CONTAMINATED PACKAGING: NO DATA AVAILABLE.


14. TRANSPORT INFORMATION 


DOT: NOT REGULATED.

IMDG: NOT REGULATED.

IATA: NOT REGULATED.

SPECIAL PRECAUTIONS FOR USER:
THIS PRODUCT IS NOT REGARDED AS DANGEROUS GOODS ACCORDING TO THE NATIONAL
AND INTERNATIONAL REGULATIONS ON THE TRANSPORT OF DANGEROUS GOODS.


15. REGULATORY INFORMATION 


US FEDERAL REGULATIONS:

TSCA SECTION 12(B) EXPORT NOTIFICATION (40 CFR 707, SUBPT. D):
NONE PRESENT OR NONE PRESENT IN REGULATED QUANTITIES.

CERCLA HAZARDOUS SUBSTANCE LIST (40 CFR 302.4):
NONE PRESENT OR NONE PRESENT IN REGULATED QUANTITIES.

SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA):

HAZARD CATEGORIES:
IMMEDIATE (ACUTE) HEALTH HAZARDS
DELAYED (CHRONIC) HEALTH HAZARD

SARA 302 EXTREMELY HAZARDOUS SUBSTANCE:
NONE PRESENT OR NONE PRESENT IN REGULATED QUANTITIES.

SARA 304 EMERGENCY RELEASE NOTIFICATION:
NONE PRESENT OR NONE PRESENT IN REGULATED QUANTITIES.

SARA 311/312 HAZARDOUS CHEMICAL:

CHEMICAL IDENTITY                               THRESHOLD PLANNING QUANTITY

DISTILLATES, PETROLEUM, HYDROTREATED MIDDLE     10000 LBS

HEXAMETHYLDISILAZANE                            10000 LBS

TITANIUM DIOXIDE                                10000 LBS

DIBUTYL TIN BIS ACETYLACETONATE                 10000 LBS

SILICA                                          10000 LBS

SARA 313 (TRI REPORTING):
NONE PRESENT OR NONE PRESENT IN REGULATED QUANTITIES.

CLEAN WATER ACT SECTION 311 HAZARDOUS SUBSTANCES (40 CFR 117.3):
NONE PRESENT OR NONE PRESENT IN REGULATED QUANTITIES.

CLEAN AIR ACT (CAA) SECTION 112(R) ACCIDENTAL RELEASE PREVENTION (40 CFR
68.130): NONE PRESENT OR NONE PRESENT IN REGULATED QUANTITIES.

US STATE REGULATIONS:

US. CALIFORNIA PROPOSITION 65:
THIS PRODUCT CONTAINS CHEMICAL(S) KNOWN TO THE STATE OF CALIFORNIA TO
CAUSE CANCER AND/OR TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

TITANIUM DIOXIDE: CARCINOGENIC.

METHANOL: DEVELOPMENTAL TOXIN.

US. NEW JERSEY WORKER AND COMMUNITY RIGHT-TO-KNOW ACT:

CHEMICAL IDENTITY:
METHYLPOLYSILOXANE

SILANE, DICHLORODIMETHYL-, REAKTION PRODUCTS WITH SILICA, SILANE,
DICHLORODIMETHYL-, REACTION PRODUCTS WITH SILICA

DISTILLATES, PETROLEUM, HYDROTREATED MIDDLE

SILOXANES AND SILICONES, DI-ME

HEXAMETHYLDISILAZANE

US. MASSACHUSETTS RTK - SUBSTANCE LIST:

CHEMICAL IDENTITY:
DISTILLATES, PETROLEUM, HYDROTREATED MIDDLE
10,10'-OXYBISPHENOXARSINE

US. PENNSYLVANIA RTK - HAZARDOUS SUBSTANCES:

CHEMICAL IDENTITY:
DISTILLATES, PETROLEUM, HYDROTREATED MIDDLE
TITANIUM DIOXIDE

US. RHODE ISLAND RTK:
NO INGREDIENT REGULATED BY RI RIGHT-TO-KNOW LAW PRESENT.

INVENTORY STATUS:

AUSTRALIA AICS: N (NEGATIVE LISTING)
REMARKS: NONE.

CANADA DSL INVENTORY LIST: Y (POSITIVE LISTING)
REMARKS: NONE.

EU EINECS LIST: Y (POSITIVE LISTING)
REMARKS: NONE.

JAPAN (ENCS) LIST: N (NEGATIVE LISTING)
REMARKS: NONE.

CHINA INVENTORY OF EXISTING CHEMICAL SUBSTANCES: Y (POSITIVE LISTING)
REMARKS: NONE.

KOREA EXISTING CHEMICALS INV. (KECI): N (NEGATIVE LISTING)
REMARKS: NONE.

CANADA NDSL INVENTORY: N (NEGATIVE LISTING)
REMARKS: NONE.

PHILIPPINES PICCS: N (NEGATIVE LISTING)
REMARKS: NONE.

US TSCA INVENTORY: Y (POSITIVE LISTING)
REMARKS: ALL COMPONENTS ARE LISTED OR EXEMPTED ON TSCA

NEW ZEALAND INVENTORY OF CHEMICALS: N (NEGATIVE LISTING)
REMARKS: NONE.

TAIWAN. TAIWAN INVENTORY (CSNN): Y (POSITIVE LISTING)
REMARKS: NONE.


16. OTHER INFORMATION, INCLUDING DATE OF PREPARATION 

                             OR LAST REVISION

HMIS HAZARD ID:
HEALTH              2*
FLAMMABILITY        1
PHYSICAL HAZARDS    0
PERSONAL PROTECTION

HAZARD RATING:
0 - MINIMAL
1 - SLIGHT
2 - MODERATE
3 - SERIOUS
4 - SEVERE

RNP - RATING NOT POSSIBLE
*CHRONIC HEALTH EFFECT

ISSUE DATE: 07/28/2016

REVISION DATE: NO DATA AVAILABLE.

VERSION #: 1.10

FURTHER INFORMATION: NO DATA AVAILABLE.

DISCLAIMER:

NOTICE TO READER:
UNLESS OTHERWISE SPECIFIED IN SECTION 1, MOMENTIVE PRODUCTS ARE INTENDED
FOR USE IN THE MANUFACTURE AND/OR FORMULATION OF PRODUCTS AND ARE NOT
INTENDED FOR DIRECT CONSUMER USE. THESE PRODUCTS ARE NOT INTENDED FOR
LONG-LASTING (>30 DAYS) IMPLANTATION, INJECTION OR DIRECT INGESTION INTO
THE HUMAN BODY, NOR FOR USE IN THE MANUFACTURE OF MULTIPLE USE
CONTRACEPTIVES. KEEP OUT OF THE REACH OF CHILDREN.

FURTHER INFORMATION:
THE INFORMATION PROVIDED IN THIS SAFETY DATA SHEET IS CORRECT TO THE BEST
OF OUR KNOWLEDGE, INFORMATION AND BELIEF AT THE DATE OF ITS PUBLICATION.
THE INFORMATION GIVEN IS DESIGNED ONLY AS A GUIDANCE FOR SAFE HANDLING,
USE, PROCESSING, STORAGE, TRANSPORTATION, DISPOSAL AND RELEASE AND IS NOT
TO BE CONSIDERED A WARRANTY OR QUALITY SPECIFICATION. THE INFORMATION
RELATES ONLY TO THE SPECIFIC MATERIAL DESIGNATED AND MAY NOT BE VALID FOR
SUCH MATERIAL USED IN COMBINATION WITH ANY OTHER MATERIALS OR IN ANY
PROCESS, UNLESS SPECIFIED IN THE TEXT.

(R*),*, AND TM INDICATE TRADEMARKS OWNED BY OR LICENSED TO MOMENTIVE.

SDS_US