SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. SAFETY DATA SHEET (SDS) COMPLIES WITH EC NO. 1907/2006 DATE OF ISSUE: 10/30/1995 DATE OF REVISION: 12/31/2021R
CAT#: 1002, 1003, 1004, 1005 PART NAME: CONTRAD 70 SUPPLIER: DECON LABORATORIES INC. 460 GLENNIE CIRCLE KING OF PRUSSIA, PA 19406 SDS TELEPHONE # (610) 755-0800 IDENTIFIED USES: LABORATORY USE EMERGENCY TELEPHONE NUMBERS: US CHEMTREC: (800) 424-9300 CANADA: (703) 527-3887
HAZARD OVERVIEW: CAUSES EYE BURNS CAUSES SKIN AND EYE IRRITATION CAUSES SKIN IRRITATION HARMFUL IF SWALLOWED. GHS CLASSIFICATION: ACUTE TOXICITY ORAL CATEGORY 4 SERIOUS EYE DAMAGE CATEGORY 1C SKIN IRRITANT CATEGORY 2 SIGNAL WORD: DANGER EXCLAMATION MARK CORROSION HAZARD AND PRECAUTIONARY STATEMENTS: H320: CAUSES EYE IRRITATION H302: HARMFUL IF SWALLOWED H315: CAUSES SKIN IRRITATION. P285: IN CASE OF INADEQUATE VENTILATION WEAR RESPIRATORY PROTECTION. P302+P352: IF ON SKIN: WASH WITH PLENTY OF SOAP AND WATER. P305B: IF IN EYES: SEPARATE EYELIDS WITH FINGER TIPS. P351: RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES. P361: REMOVE/TAKE OFF IMMEDIATELY ALL CONTAMINATED CLOTHING. NFPA RATING: HAZARD RATINGS: THESE RATINGS ARE DECON LABORATORIES INC.'S OWN ASSESSMENTS OF THE PROPERTIES OF THE MATERIAL USING THE ANSI/NFPA 704 STANDARD. ADDITIONAL INFORMATION CAN BE FOUND BY CONSULTING IN THE NFPA PUBLISHED RATINGS LISTS (LIST 325 AND LIST 49). IF NO DATA IS LISTED THE INFORMATION IS NOT AVAILABLE HEALTH 2 FLAMMABILITY 0 REACTIVITY 0
NOTE: ITEMS LISTED WITH A CASRN NUMBER HAVE NO CAS# AVAILABLE ITEM# NAME EINECS CAS# % IN PRODUCT 1 POTASSIUM HYDROXIDE 215-181-3 0001310583 0 - 5 2 TRISODIUM CITRATE DIHYDRATE UNKNOWN 0006132043 6 - 10 3 WATER 231-791-2 0007732185 81 - 90
FLUSH EYES WITH FLOWING WATER FOR AT LEAST 15 MINTUES. REMOVE CONTAMINATED CLOTHING. SEPARATE EYELIDS WITH FINGER TIPS. WASH SKIN WITH DELUGE OF WATER FOR AT LEAST 15 MINUTES.
FLASH POINT, DEG. F: NO DATA METHOD: NO DATA UEL: NO DATA LEL: NO DATA AUTOIGNITION TEMPERATURE, DEG. F: NO DATA FLAMMABILITY CLASSIFICATION: NO DATA FLAME PROPAGATION RATE: NO DATA HAZARDOUS COMBUSTION PRODUCTS: NO DATA
ANY INFORMATION LISTED BELOW IS TO BE CONSIDERED IN ADDITION TO INTERNAL GUIDELINES FOR ISOLATION OF SPILL, CONTAINMENT OF SPILL, REMOVAL OF IGNITION SOURCES FROM IMMEDIATE AREA, AND COLLECTION FOR DISPOSAL OF SPILL BY TRAINED, PROPERLY PROTECTED CLEAN UP PERSONNEL. NO SPECIAL MEAURES INDICATED.
STORE AT ROOM TEMPERATURE
OSHA (ACGIH) EXPOSURE LIMITS: TWA STEL CEILING PPM MG/ PPM MG/ PPM MG/ CAS # 0000102716 IDLH: OSHA NOT CLASSIFIED ACGIH 5 CAS # 0001310583 IDLH: OSHA NOT CLASSIFIED ACGIH 2 CAS # 0006132043 IDLH: NE OSHA NE NE NE NE NE NE ACGIH NE NE NE NE NE NE CAS # 0007732185 IDLH: NE OSHA NE NE NE NE NE NE ACGIH NE NE NE NE NE NE CAS # 0027176870 IDLH: NE OSHA NE NE NE NE NE NE ACGIH NE NE NE NE NE NE CAS # 0068154972 IDLH: NE OSHA NE NE NE NE NE NE ACGIH NE NE NE NE NE NE THE USE OF EYE PROTECTION IN THE FORM OF SAFETY GLASSES WITH SIDE SHIELDS AND THE USE OF SKIN PROTECTION FOR HANDS IN THE FORM OF GLOVES ARE CONSIDERED MINIMUM AND NON-DISCRETIONARY IN WORK PLACES AND LABORATORIES. ANY RECOMMENDED PERSONAL PROTECTION EQUIPMENT OR ENVIRONMENTAL EQUIPMENT IS TO BE CONSIDERED AS ADDITIONAL TO SAFETY GLASSES AND GLOVES. USE PROCESS ENCLOSURES, LOCAL EXHAUST VENTILATION, OR OTHER ENGINEERING CONTROLS. CHEMICAL-RESISTANT GLOVES SHOULD BE WORN WHENEVER THIS MATERIAL IS HANDLED. THE GLOVE MATERIAL HAS TO BE IMPERMEABLE AND RESISTANT TO THE PRODUCT. GLOVES SHOULD BE REMOVED AND REPLACED IMMEDIATELY IF THERE IS ANY INDICATION OF DEGRADATION OR CHEMICAL BREAKTHROUGH. RINSE AND REMOVE GLOVES IMMEDIATELY AFTER USE. WASH HANDS WITH SOAP AND WATER. ALL GLOVE RECOMMENDATIONS PRESUME THAT THE RISK OF EXPOSURE IS THROUGH SPLASH AND NOT INTENTIONAL IMMERSION OF THE HANDS INTO THE PRODUCT. SINCE GLOVE PERMEATION DATA DOES NOT EXIST FOR THIS MATERIAL, NO RECOMMENDATION FOR THE GLOVE MATERIAL CAN BE GIVEN FOR THE PRODUCT. PERMEATION DATA MUST BE OBTAINED FROM THE GLOVE MANUFACTURER TO DETERMINE IF THE GLOVE IS SUITABLE FOR THE TASK.
FORMULA: NO DATA VAPOR PRESSURE: NO DATA FORMULA WEIGHT: NO DATA VAPOR DENSITY: NO DATA BOILING POINT: 212 DEG. F SPECIFIC GRAVITY: 1.05 MELTING POINT: 32 DEG. F PH: 12-14 SOLUBILITY: MISCIBLE APPEARANCE: MILKY MOBILE LIQUID
CHEMICAL STABILITY: STABLE CONDITIONS TO AVOID: NONE INCOMPATIBILITY WITH OTHER MATERIALS: STRONG ACIDS HAZARDOUS DECOMPOSITION PRODUCTS: NO DATA HAZARDOUS POLYMERIZATION: WILL NOT OCCUR
ACUTE DATA: NO DATA SUB CHRONIC DATA: NO DATA
NO DATA.
THE FOLLOWING CHART LISTS THE STATUS OF THE CHEMICAL AND ITS COMPONENTS IN REFERENCE TO 40 CFR PART 261.33. IF THE PRODUCT IS LISTED BY CODE NUMBER THE SUBSTANCE MAY BE SUBJECT TO SPECIAL FEDERAL AND STATE DISPOSAL REGULATIONS. IF NO CODES ARE LISTED THE MATERIAL MUST BE DISPOSED IN COMPLIANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS. CAS # WASTE CODE REGULATED NAME 0000102716 NOT LISTED NOT LISTED 0001310583 NOT LISTED NOT LISTED 0006132043 NOT LISTED NOT LISTED 0007732185 NOT LISTED NOT LISTED 0027176870 NOT LISTED NOT LISTED 0068154972 NOT LISTED NOT LISTED
PROPER SHIPPING NAME: POTASSIUM HYDROXIDE, SOLUTION NOTE: 1 LITER & SAMPLE SIZE: ORM-D OR LTD QTY CHEMICAL NAME: UN #: UN1814 CLASS: 8 PACKING GROUP: LL
ALL COMPONENTS OF THIS PRODUCT ARE ON THE TSCA PUBLIC INVENTORY. PROP 65 - COLUMN A IDENTIFIES THOSE ITEMS WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER. COLUMN B IDENTIFIED ITEMS WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE REPRODUCTIVE TOXICITY. CAS# COLUMN A COLUMN B 0000102716 NO NO 0001310583 NO NO 0006132043 NO NO 0007732185 NO NO 0027176870 NO NO 0068154972 NO NO STATE REGULATORY INFORMATION: IF A CAS# IS LISTED BELOW THIS MATERIAL IS SUBJECT TO THE LISTED STATE RIGHT-TO-KNOW REQUIREMENTS. CAS#: CAS#: 0000102716 NOT LISTED 0001310583 NOT LISTED 0006132043 NOT LISTED 0007732185 NOT LISTED 0027176870 NOT LISTED 0068154972 NOT LISTED SARA TOXIC RELEASE CHEMICALS(AS DEFINED IN SECTION 313 OF SARA TITLE III) THIS LIST IDENTIFIES THE TOXIC CHEMICALS, INCLUDING THEIR DE MINIMIS CONCENTRATIONS FOR WHICH REPORTING IS REQUIRED UNDER SECTION 313 OF THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW ACT (EPCRA). THE LIST IS ALSO REFERRED TO AS THE TOXICS RELEASE INVENTORY (TRI) LIST. CAS# REGULATED NAME DE MINIMUS CONC. % REP THRES. 0000102716 NOT LISTED NOT LISTED NOT LISTED 0001310583 NOT LISTED NOT LISTED NOT LISTED 0006132043 NOT LISTED NOT LISTED NOT LISTED 0007732185 NOT LISTED NOT LISTED NOT LISTED 0027176870 NOT LISTED NOT LISTED NOT LISTED 0068154972 NOT LISTED NOT LISTED NOT LISTED SARA EXTREMELY HAZARDOUS SUBSTANCES AND TPQS THIS LIST INCLUDES HAZARDOUS CHEMICALS AS DEFINED IN 29 CFR 1910.1200(C); AND EXTREMELY HAZARDOUS SUBSTANCES REGULATED UNDER SECTION 302 OF SARA TITLE III WITH THEIR TPQS (IN POUNDS), AS LISTED IN 40 CFR 355, APPENDICES A AND B. CAS# REGULATED NAME TPQ (POUNDS) EHS RQ (POUNDS) 0000102716 NOT LISTED NOT LISTED NOT LISTED 0001310583 NOT LISTED NOT LISTED NOT LISTED 0006132043 NOT LISTED NOT LISTED NOT LISTED 0007732185 NOT LISTED NOT LISTED NOT LISTED 0027176870 NOT LISTED NOT LISTED NOT LISTED 0068154972 NOT LISTED NOT LISTED NOT LISTED CERCLA: THE HAZARDOUS SUBSTANCES, AND THEIR REPORTABLE QUANTITIES (RQS) ARE LISTED IN THE FEDERAL REGULATIONS AT 40 CFR PART 302, TABLE 302.4. RELEASE OF A CERCLA HAZARDOUS SUBSTANCE IN AN AMOUNT EQUAL TO OR GREATER THAN ITS RQ, IN ANY 24-HOUR PERIOD, MUST BE REPORTED TO THE NATIONAL RESPONSE CENTER AT (800) 424-8802. CAS# REGULATED NAME RQ (POUNDS) 0000102716 NOT LISTED NOT LISTED 0001310583 NOT LISTED NOT LISTED 0001310583 POTASSIUM HYDROXIDE 1,000 0006132043 NOT LISTED NOT LISTED 0007732185 NOT LISTED NOT LISTED 0027176870 NOT LISTED NOT LISTED 0027176870 DODECYL BENZENESULFONIC ACID 1,000 0068154972 NOT LISTED NOT LISTED
DATE OF ISSUE: 10/30/1995 DATE OF REVISION: 12/31/2021R DECON LABORATORIES, INC. PROVIDES THE INFORMATION CONTAINED HEREIN IN GOOD FAITH BUT MAKES NO REPRESENTATION AS TO ITS COMPREHENSIVENESS OR ACCURACY. INDIVIDUALS RECEIVING THIS INFORMATION MUST EXERCISE THEIR INDEPENDENT JUDGMENT IN DETERMINING ITS APPROPRIATENESS FOR A PARTICULAR PURPOSE. DECON LABORATORIES, INC. MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESSED OR IMPLIED OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR TO WHICH THE INFORMATION REFERS. ACCORDINGLY, DECON LABORATORIES, INC. WILL NOT BE RESPONSIBLE FOR DAMAGES RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. |