Common Name: CONTRAD 100
Manufacturer: DECON LABORATORIES
SDS Revision Date: 5/8/2015
SDS Format: GHS-US
   
Item Number(s): 42X068, 42X069, 42X070, 42X071
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 
SECTION 2: HAZARDS IDENTIFICATION 
SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION 4: FIRST AID MEASURES 
SECTION 5: FIRE-FIGHTING MEASURES 
SECTION 6: ACCIDENTAL RELEASE MEASURES 
SECTION 7: HANDLING AND STORAGE 
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10: STABILITY AND REACTIVITY 
SECTION 11: TOXICOLOGICAL INFORMATION 
SECTION 12: ECOLOGICAL INFORMATION 
SECTION 13: DISPOSAL CONSIDERATIONS 
SECTION 14: TRANSPORTATION INFORMATION 
SECTION 15: REGULATORY INFORMATION 
SECTION 16: OTHER INFORMATION 



SAFETY DATA SHEET (SDS)

COMPLIES WITH EC NO. 1907/2006

DATE OF ISSUE: 01/01/1998

DATE OF REVISION: 05/08/2015


SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 


CAT#: 1503, 1504, 1505, 1506

PART NAME: CONTRAD 100

SUPPLIER:
DECON LABORATORIES INC.
460 GLENNIE CIRCLE KING OF PRUSSIA, PA 19406

SDS TELEPHONE #: (610) 755-0800

EMERGENCY TELEPHONE NUMBERS:
US CHEMTREC: (800) 424-9300
CANADA: (703) 527-3887

IDENTIFIED USES: LABORATORY USE

EMAIL CONTACT: CVELOSKI@DECONLABS.COM


SECTION 2: HAZARDS IDENTIFICATION 


HAZARD OVERVIEW: CAUSES SKIN AND EYE BURNS

GHS CLASSIFICATION:
SERIOUS EYE DAMAGE CAT 1C, SKIN CORROSION CAT 1C, EYE IRRITATION CAT 2B

SIGNAL WORD: DANGER

CORROSION

HAZARD AND PRECAUTIONARY STATEMENTS:

H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE

P280:
WEAR PROTECTIVE GLOVES/PROTECTIVE CLOTHING/EYE PROTECTION/FACE PROTECTION.

P280D:
WEAR PROTECTIVE GLOVES. USE BUTYL RUBBER GLOVES. LATEX IS NOT ADEQUATE

P302+P352:
IF ON SKIN: WASH WITH PLENTY OF SOAP AND WATER.

P305B:
IF IN EYES: SEPARATE EYELIDS WITH FINGER TIPS.

P314: GET MEDICAL ADVICE/ATTENTION IF YOU FEEL UNWELL

P351: RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES.

NFPA RATING:

HAZARD RATINGS:
THESE RATINGS ARE DECON LABORATORIES INC.'S OWN ASSESSMENTS OF THE
PROPERTIES OF THE MATERIAL USING THE ANSI/NFPA 704 STANDARD. ADDITIONAL
INFORMATION CAN BE FOUND BY CONSULTING IN THE NFPA PUBLISHED RATINGS LISTS
(LIST 325 AND LIST 49).

IF NO DATA IS LISTED THE INFORMATION IS NOT AVAILABLE

HEALTH       3
FLAMMABILITY 0
REACTIVITY   0


SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 


NOTE: ITEMS LISTED WITH A CASRN NUMBER HAVE NO CAS# AVAILABLE

ITEM#  NAME                             EINECS     CAS #       % IN PRODUCT

1      2-PROPENOIC ACID, HOMOPOLYMER    UNKNOWN    0009003014   0 - 5

2      GLYCINE, N,N'-1,2-ETHANEDIYLBIS  205-358-3  0000139333   0 - 5
       [N-(CARBOXYMETHYL)-, DISODIUM
       SALT

3      POTASSIUM HYDROXIDE              215-181-3  0001310583  21 - 30

4      WATER                            231-791-2  0007732185  71 - 80


SECTION 4: FIRST AID MEASURES 


CONTACT MEDICAL PERSONNEL IF DISCOMFORT PERSISTS

FLUSH EYES WITH FLOWING WATER FOR AT LEAST 15 MINUTES.

SEPARATE EYELIDS WITH FINGER TIPS.

WASH SKIN WITH DELUGE OF WATER FOR AT LEAST 15 MINUTES.


SECTION 5: FIRE-FIGHTING MEASURES 


FLASH POINT, DEG. F: >200
METHOD:

UEL: NO DATA
LEL: NO DATA

AUTOIGNITION TEMPERATURE, DEG. F: NO DATA

FLAMMABILITY CLASSIFICATION: NO DATA

FLAME PROPAGATION RATE: NO DATA

HAZARDOUS COMBUSTION PRODUCTS: NO DATA


SECTION 6: ACCIDENTAL RELEASE MEASURES 


ANY INFORMATION LISTED BELOW IS TO BE CONSIDERED IN ADDITION TO INTERNAL
GUIDELINES FOR ISOLATION OF SPILL, CONTAINMENT OF SPILL, REMOVAL OF
IGNITION SOURCES FROM IMMEDIATE AREA, AND COLLECTION FOR DISPOSAL OF SPILL
BY TRAINED, PROPERLY PROTECTED CLEAN UP PERSONNEL.

ABSORBS LIQUIDS ON ABSORBENT MATERIAL.

CONTAIN SPILLED LIQUIDS.

PROTECT PERSONNEL FROM EXPOSURE.


SECTION 7: HANDLING AND STORAGE 


STORE AT ROOM TEMPERATURE


SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 


OSHA (ACGIH) EXPOSURE LIMITS:

                             TWA               STEL            CEILING
                       PPM         MG/      PPM     MG/    PPM    MG/

CAS #: 0000139333

IDLH: NE

OSHA                   NE          NE       NE     NE      NE     NE

ACGIH                  NE          NE       NE     NE      NE     NE

CAS #: 0001310583

IDLH:

OSHA                   NOT
                       CLASSIFIED

ACGIH                                                             2

CAS #: 0007732185

IDLH: NE

OSHA                   NE          NE       NE     NE      NE     NE

ACGIH                  NE          NE       NE     NE      NE     NE

CAS #: 0009003014

IDLH: NE

OSHA                   NE          NE       NE     NE      NE     NE

ACGIH                  NE          NE       NE     NE      NE     NE

THE USE OF EYE PROTECTION IN THE FORM OF SAFETY GLASSES WITH SIDE SHIELDS
AND THE USE OF SKIN PROTECTION FOR HANDS IN THE FORM OF GLOVES ARE
CONSIDERED MINIMUM AND NON-DISCRETIONARY IN WORK PLACES AND LABORATORIES.
ANY RECOMMENDED PERSONAL PROTECTION EQUIPMENT OR ENVIRONMENTAL EQUIPMENT
IS TO BE CONSIDERED AS ADDITIONAL TO SAFETY GLASSES AND GLOVES.

USE BUTYL RUBBER GLOVES. LATEX IS NOT ADEQUATE

USE CHEMICAL SPLASH GOGGLES AND FACE SHIELD.

CHEMICAL-RESISTANT GLOVES SHOULD BE WORN WHENEVER THIS MATERIAL IS HANDLED.
THE GLOVE MATERIAL HAS TO BE IMPERMEABLE AND RESISTANT TO THE PRODUCT.
GLOVES SHOULD BE REMOVED AND REPLACED IMMEDIATELY IF THERE IS ANY
INDICATION OF DEGRADATION OR CHEMICAL BREAKTHROUGH. RINSE AND REMOVE
GLOVES IMMEDIATELY AFTER USE. WASH HANDS WITH SOAP AND WATER. ALL GLOVE
RECOMMENDATIONS PRESUME THAT THE RISK OF EXPOSURE IS THROUGH SPLASH AND
NOT INTENTIONAL IMMERSION OF THE HANDS INTO THE PRODUCT. SINCE GLOVE
PERMEATION DATA DOES NOT EXIST FOR THIS MATERIAL, NO RECOMMENDATION FOR
THE GLOVE MATERIAL CAN BE GIVEN FOR THE PRODUCT. PERMIATION DATA MUST BE
OBTAINED FROM THE GLOVE MANUFACTURER TO DETERMINE IF THE GLOVE IS SUITABLE
FOR THE TASK.


SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 


FORMULA: NO DATA

VAPOR PRESSURE: NO DATA

FORMULA WEIGHT: NO DATA

VAPOR DENSITY: NO DATA

BOILING POINT: 212 DEG. F

SPECIFIC GRAVITY: 1.27

MELTING POINT: 32 DEG. F

PH: >13

SOLUBILITY: MISCIBLE

APPEARANCE: CLEAR COLORLESS LIQUID


SECTION 10: STABILITY AND REACTIVITY 


CHEMICAL STABILITY: STABLE

CONDITIONS TO AVOID: NONE

INCOMPATIBILITY WITH OTHER MATERIALS: ACIDS

HAZARDOUS DECOMPOSITION PRODUCTS: NONE

HAZARDOUS POLYMERIZATION: WILL NOT OCCUR


SECTION 11: TOXICOLOGICAL INFORMATION 


ACUTE DATA: NO DATA

SUBCHRONIC DATA: NO DATA


SECTION 12: ECOLOGICAL INFORMATION 


NO DATA.


SECTION 13: DISPOSAL CONSIDERATIONS 


THE FOLLOWING CHART LISTS THE STATUS OF THE CHEMICAL AND ITS COMPONENTS IN
REFERENCE TO 40 CFR PART 261.33. IF THE PRODUCT IS LISTED BY CODE NUMBER
THE SUBSTANCE MAY BE SUBJECT TO SPECIAL FEDERAL AND STATE DISPOSAL
REGULATIONS. IF NO CODES ARE LISTED THE MATERIAL MUST BE DISPOSED IN
COMPLIANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

CAS #                    WASTE CODE              REGULATED NAME

0000139333               NOT LISTED              NOT LISTED

0001310583               NOT LISTED              NOT LISTED

0007732185               NOT LISTED              NOT LISTED

0009003014               NOT LISTED              NOT LISTED


SECTION 14: TRANSPORTATION INFORMATION 


PROPER SHIPPING NAME: POTASSIUM HYDROXIDE, SOLUTION

CHEMICAL NAME:
UN #: UN1814
CLASS: 8

PACKING GROUP: II


SECTION 15: REGULATORY INFORMATION 


ALL COMPONENTS OF THIS PRODUCT ARE ON THE TSCA PUBLIC INVENTORY.

PROP 65:
COLUMN A IDENTIFIES THOSE ITEMS WHICH ARE KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER. COLUMN B IDENTIFIED ITEMS WHICH ARE KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE REPRODUCTIVE TOXICITY.

CAS#                      COLUMN A                 COLUMN B

0000139333                NO                       NO

0001310583                NO                       NO

0007732185                NO                       NO

0009003014                NO                       NO

STATE REGULATORY INFORMATION:
IF A CAS# IS LISTED BELOW THIS MATERIAL IS SUBJECT TO THE LISTED STATE
RIGHT-TO-KNOW REQUIREMENTS.

CAS#

CAS#

0000139333             NOT LISTED

0001310583             NOT LISTED

0007732185             NOT LISTED

0009003014             NOT LISTED

SARA TOXIC RELEASE CHEMICALS(AS DEFINED IN SECTION 313 OF SARA TITLE III):
THIS LIST IDENTIFIES THE TOXIC CHEMICALS, INCLUDING THEIR DE MINIMIS
CONCENTRATIONS FOR WHICH REPORTING IS REQUIRED UNDER SECTION 313 OF THE
EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW ACT (EPCRA). THE LIST IS
ALSO REFERRED TO AS THE TOXICS RELEASE INVENTORY (TRI) LIST.

CAS#             REGULATED NAME     DE MINIMUS CONC. %     REP THRES.

0000139333       NOT LISTED         NOT LISTED             NOT LISTED

0001310583       NOT LISTED         NOT LISTED             NOT LISTED

0007732185       NOT LISTED         NOT LISTED             NOT LISTED

0009003014       NOT LISTED         NOT LISTED             NOT LISTED

SARA EXTREMELY HAZARDOUS SUBSTANCES AND TPQS:
THIS LIST INCLUDES HAZARDOUS CHEMICALS AS DEFINED IN 29 CFR 1910.1200(C);
AND EXTREMELY HAZARDOUS SUBSTANCES REGULATED UNDER SECTION 302 OF SARA
TITLE III WITH THEIR TPQS (IN POUNDS), AS LISTED IN 40 CFR 355, APPENDICES
A AND B.

CAS#            REGULATED NAME      TPQ (POUNDS)    EHS RQ (POUNDS)

0000139333      NOT LISTED          NOT LISTED      NOT LISTED

0001310583      NOT LISTED          NOT LISTED      NOT LISTED

0007732185      NOT LISTED          NOT LISTED      NOT LISTED

0009003014      NOT LISTED          NOT LISTED      NOT LISTED

CERCLA:
THE HAZARDOUS SUBSTANCES, AND THEIR REPORTABLE QUANTITIES (RQS) ARE LISTED
IN THE FEDERAL REGULATIONS AT 40 CFR PART 302, TABLE 302.4. RELEASE OF A
CERCLA HAZARDOUS SUBSTANCE IN AN AMOUNT EQUAL TO OR GREATER THAN ITS RQ,
IN ANY 24-HOUR PERIOD, MUST BE REPORTED TO THE NATIONAL RESPONSE CENTER AT
(800) 424-8802.

CAS#                 REGULATED NAME             RQ (POUNDS)

0000139333           NOT LISTED                 NOT LISTED

0001310583           NOT LISTED                 NOT LISTED

0001310583           POTASSIUM HYDROXIDE        1,000

0007732185           NOT LISTED                 NOT LISTED

0009003014           NOT LISTED                 NOT LISTED


SECTION 16: OTHER INFORMATION 


DATE OF ISSUE: 01/01/1998

DATE OF REVISION: 05/08/2015

DECON LABORATORIES, INC. PROVIDES THE INFORMATION CONTAINED HEREIN IN GOOD
FAITH BUT MAKES NO REPRESENTATION AS TO ITS COMPREHENSIVENESS OR ACCURACY.
INDIVIDUALS RECEIVING THIS INFORMATION MUST EXERCISE THEIR INDEPENDENT
JUDGMENT IN DETERMINING ITS APPROPRIATENESS FOR A PARTICULAR PURPOSE.
DECON LABORATORIES, INC. MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER
EXPRESSED OR IMPLIED OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES
WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR TO WHICH THE
INFORMATION REFERS. ACCORDINGLY, DECON LABORATORIES, INC. WILL NOT BE
RESPONSIBLE FOR DAMAGES RESULTING FROM THE USE OF OR RELIANCE UPON THIS
INFORMATION.