Common Name: CORK TAPE
Manufacturer: K-FLEX
SDS Revision Date: 2/23/2015
SDS Format: ANSI-OSHA
   
Item Number(s): 45AT32
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1: COMPANY AND PRODUCT IDENTIFICATION 
SECTION 2: COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION 3: HAZARD(S) IDENTIFICATION 
SECTION 4: FIRST AID MEASURES 
SECTION 5: FIRE FIGHTING MEASURES 
SECTION 6: ACCIDENTAL RELEASE MEASURES 
SECTION 7: HANDLING AND STORAGE 
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10: STABILITY AND REACTIVITY 
SECTION 11: TOXICOLOGICAL INFORMATION 
SECTION 12: ECOLOGICAL INFORMATION 
SECTION 13: DISPOSAL CONSIDERATIONS 
SECTION 14: TRANSPORTATION INFORMATION 
SECTION 15: REGULATORY INFORMATION 
SECTION 16: ADDITIONAL INFORMATION 



IK INSULATION GROUP
K-FLEX USA

CORK TAPE

23-FEB-15

SDS12-0215

SAFETY DATA SHEET


SECTION 1: COMPANY AND PRODUCT IDENTIFICATION 


MANUFACTURER'S NAME AND ADDRESS:
K-FLEX USA
100 NOMACO DR
YOUNGSVILLE, NC 27596
USA

SUPPLIER'S NAME AND ADDRESS: REFER TO MANUFACTURER

TELEPHONE NO.: (800) 765-6475

WEBSITE ADDRESS: WWW.KFLEXUSA.COM

PRODUCT IDENTIFIER: CORK TAPE

PRODUCT DESCRIPTION: ASPHALT CORK TAPE


SECTION 2: COMPOSITION/INFORMATION ON INGREDIENTS 


BASED ON DATA AVAILABLE, NONE OF THE COMPONENTS IN THIS PRODUCT ARE
CONSIDERED HAZARDOUS ACCORDING TO OSHA HAZARD COMMUNICATION STANDARD (29
CFR 1910.1200). THE COMPOSITION OF THIS COMPOUND IS PROPRIETARY
INFORMATION. IN THE EVENT OF A MEDICAL EMERGENCY, DETAILED INFORMATION WILL
BE PROVIDED TO A NURSE OR PHYSICIAN.

CHEMICAL NAME  CAS #      PERCENT   OSHA PEL

ASPHALT        8052-43-4  10 - 30   TLV 5 MG/M (FUMES)


SECTION 3: HAZARD(S) IDENTIFICATION 


EMERGENCY OVERVIEW:

HMIS RATING:
HEALTH       1
FLAMMABILITY 1
REACTIVITY   0

SEE SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION FOR PERSONAL
PROTECTIVE EQUIPMENT RECOMMENDATIONS.

POTENTIAL HEALTH EFFECTS BY ROUTE OF ENTRY:

EYE: NO IRRITATION HAZARD IN NORMAL INDUSTRIAL USE.

SKIN: NO IRRITATION HAZARD IN NORMAL INDUSTRIAL USE.

INHALATION:
NO IRRITATION HAZARD IN NORMAL INDUSTRIAL USE. INHALATION OF DUSTS PRODUCED
DURING CUTTING, GRINDING OR SANDING OF THIS PRODUCT MAY CAUSE IRRITATION OF
THE RESPIRATORY TRACT. PROLONGED EXPOSURE MAY LEAD TO INFLAMMATION AND
ULCERATION.

INGESTION: INGESTION IS NOT AN ANTICIPATED ROUTE OF EXPOSURE.

LONG-TERM (CHRONIC) HEALTH EFFECTS:

TARGET ORGAN(S):
NO ORGANS KNOWN TO BE DAMAGED FROM EXPOSURE TO THIS PRODUCT.

REGULATED CARCINOGEN STATUS:
UNLESS NOTED BELOW, THIS PRODUCT DOES NOT CONTAIN REGULATED LEVELS OF NTP,
IARC, ACGIH, OR OSHA LISTED CARCINOGENS.

EXISTING HEALTH CONDITIONS AFFECTED BY EXPOSURE:
NO MEDICAL CONDITIONS AFFECTED BY EXPOSURE.


SECTION 4: FIRST AID MEASURES 


IF IN EYES:
THIS PRODUCT IS AN INERT SOLID. REMOVE THE SUBSTANCE FROM THE EYE(S), AND
IMMEDIATELY FLUSH EYE(S) WITH PLENTY OF WATER WHILE RETRACTING EYELIDS
OFTEN. IF INFLAMMATION OR BLURRED VISION DEVELOPS, SEEK MEDICAL ATTENTION
AND PROVIDE THE MEDICAL CARE PROFESSIONAL WITH THIS MSDS.

IF ON SKIN: WASH WITH SOAP AND WATER.

IF VAPORS INHALED:
NOT AN ANTICIPATED ROUTE OF EXPOSURE. THIS PRODUCT IS AN INERT SOLID. IF
DUSTS ARE PRODUCED BY CUTTING OR SANDING THIS PRODUCT, PLEASE CONSIDER
IMPROVING WORK SITE VENTILATION.

IF SWALLOWED:
NO HAZARD IN NORMAL INDUSTRIAL USE. DO NOT INDUCE VOMITING. SEEK MEDICAL
ATTENTION IF SYMPTOMS DEVELOP. PROVIDE MEDICAL CARE PROVIDER WITH THIS
MSDS.


SECTION 5: FIRE FIGHTING MEASURES 


FLASH POINT: NOT APPLICABLE

AUTOIGNITION TEMPERATURE: NOT ESTABLISHED

LOWER EXPLOSIVE LIMIT (% IN AIR): NOT ESTABLISHED
UPPER EXPLOSIVE LIMIT (% IN AIR): NOT ESTABLISHED

EXTINGUISHING MEDIA: USE WATER SPRAY, FOAM, DRY CHEMICAL OR CARBON DIOXIDE.

UNUSUAL FIRE AND EXPLOSION HAZARDS: MATERIAL WILL BURN IN A FIRE.

SPECIAL FIRE FIGHTING INSTRUCTIONS:
PERSONS EXPOSED TO PRODUCTS OF COMBUSTION SHOULD WEAR SELF-CONTAINED
BREATHING APPARATUS AND FULL PROTECTIVE EQUIPMENT.

HAZARDOUS COMBUSTION PRODUCTS:
CARBON DIOXIDE, CARBON MONOXIDE, BROMINE CONTAINING GASES


SECTION 6: ACCIDENTAL RELEASE MEASURES 


SPECIAL PROTECTION:
NO ADVERSE HEALTH EFFECTS EXPECTED FROM THE CLEAN-UP OF SPILLED MATERIAL.
FOLLOW PERSONAL PROTECTIVE EQUIPMENT RECOMMENDATIONS FOUND IN SECTION 8 OF
THIS MSDS.

TRANSPORT EMERGENCY PHONE NUMBER (CHEMTREC): 1-800-424-9300


SECTION 7: HANDLING AND STORAGE 


HANDLING: NO SPECIAL HANDLING INSTRUCTIONS DUE TO TOXICITY.

STORAGE: STORE IN A COOL, DRY PLACE.

CONSULT THE TECHNICAL DATA SHEET FOR SPECIFIC STORAGE INSTRUCTIONS.


SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 


EYE PROTECTION: WEAR GOGGLES WHEN HANDLING THIS PRODUCT.

SKIN PROTECTION:
PROTECT SKIN ACCORDINGLY IF WORKING IN ENVIRONMENTS WITH ELEVATED
TEMPERATURES.

GLOVES: NOT NORMALLY REQUIRED. USE NITRILE GLOVES IF CONDITIONS WARRANT.

RESPIRATORY PROTECTION: NOT NORMALLY REQUIRED.

VENTILATION: USE LOCAL EXHAUST VENTILATION TO MINIMIZE EXPOSURE.

HYGIENIC PRACTICES:
WASH HANDS BEFORE EATING, SMOKING, OR USING THE RESTROOM.

EXPOSURE LIMITS:
NONE APPLICABLE FOR THIS PRODUCT WHEN USED FOR NORMAL INDUSTRIAL
APPLICATIONS. AVOID EXCESSIVE AND UNNECESSARY EXPOSURE WHENEVER POSSIBLE.
IF DEEMED USEFUL AND ESSENTIAL FOR TREATMENT, SPECIFIC EXPOSURE LIMITS OF
RAW MATERIALS USED DURING THE MANUFACTURING PROCESS WILL BE PROVIDED TO A
NURSE OR PHYSICIAN.


SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 


PHYSICAL STATE: SOLID

COLOR: BLACK

ODOR: ASPHALTIC

ODOR THRESHOLD: NOT ESTABLISHED

SPECIFIC GRAVITY: 0.75 - 0.85

SOLIDS (% BY WEIGHT): 100%

PH: NOT ESTABLISHED

BOILING POINT (DEG. C): NOT ESTABLISHED

FREEZING/MELTING POINT (DEG. C): NOT ESTABLISHED

VAPOR PRESSURE (MM Hg): NOT ESTABLISHED

VAPOR DENSITY: NOT ESTABLISHED

EVAPORATION RATE: NOT ESTABLISHED

OCTANOL/WATER COEFFICIENT: NOT ESTABLISHED


SECTION 10: STABILITY AND REACTIVITY 


STABILITY: STABLE UNDER NORMAL CONDITIONS

CHEMICAL INCOMPATIBILITY: NOT ESTABLISHED

HAZARDOUS POLYMERIZATION: WILL NOT OCCUR

HAZARDOUS DECOMPOSITION PRODUCTS:
CARBON MONOXIDE, CARBON DIOXIDE, BROMINE CONTAINING GASES


SECTION 11: TOXICOLOGICAL INFORMATION 


CHEMICAL NAME       LD50/LC50

CALCIUM CARBONATE   ORAL LD50 RAT: =6450 MG/KG

CARBON BLACK        ORAL LD50 RAT: >15400 MG/KG;
                    DERMAL LD50 RABBIT: > KG

TOXICOLOGY SUMMARY: NO ADDITIONAL HEALTH INFORMATION AVAILABLE.


SECTION 12: ECOLOGICAL INFORMATION 


OVERVIEW: NO ECOLOGICAL INFORMATION AVAILABLE.


SECTION 13: DISPOSAL CONSIDERATIONS 


TO THE BEST OF OUR KNOWLEDGE, THIS PRODUCT DOES NOT MEET THE DEFINITION OF
HAZARDOUS WASTE UNDER THE U.S. EPA HAZARDOUS WASTE REGULATIONS 40 CFR 261.
DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL LAW. CONSULT YOUR
STATE, LOCAL OR PROVINCIAL AUTHORITIES AND YOUR LOCAL WASTE VENDOR FOR MORE
RESTRICTIVE REQUIREMENTS.


SECTION 14: TRANSPORTATION INFORMATION 


CONSULT BILL OF LADING FOR TRANSPORTATION INFORMATION.


SECTION 15: REGULATORY INFORMATION 


INVENTORY STATUS:

U.S. EPA TSCA:
THIS PRODUCT IS IN COMPLIANCE WITH THE TOXIC SUBSTANCES CONTROL ACT'S
INVENTORY REQUIREMENTS.

IF YOU NEED MORE INFORMATION ABOUT THE INVENTORY STATUS OF THIS PRODUCT,
CALL 651-236-5858.

THIS PRODUCT MAY CONTAIN CHEMICAL SUBSTANCES THAT ARE REGULATED FOR EXPORT
BY VARIOUS GOVERNMENT AGENCIES (SUCH AS THE ENVIRONMENTAL PROTECTION
AGENCY, THE BUREAU OF INDUSTRY AND SECURITY, OR THE DRUG ENFORCEMENT
ADMINISTRATION, AMONG OTHERS).

FEDERAL REPORTING:

EPA SARA TITLE III SECTION 313:
UNLESS LISTED BELOW, THIS PRODUCT DOES NOT CONTAIN TOXIC CHEMICAL(S)
SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF TITLE III OF THE
SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (SARA) AND 40 CFR PART
72. EPA HAS ADVISED THAT WHEN A PERCENTAGE RANGE IS LISTED THE MIDPOINT MAY
BE USED TO FULFILL REPORTING OBLIGATIONS.

CHEMICAL NAME      CAS#   %

NONE APPLICABLE

NONE APPLICABLE

NONE APPLICABLE

CANADIAN WHMIS STATUS:
TO THE BEST OF OUR KNOWLEDGE, THIS MATERIAL IS CLASSIFIED AS A
NON-CONTROLLED PRODUCT.


SECTION 16: ADDITIONAL INFORMATION 


THIS MATERIAL SAFETY DATA SHEET IS PREPARED TO COMPLY WITH THE UNITED
STATES OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) HAZARD
COMMUNICATION STANDARD (29 CFR 1910.1200).

PREPARED BY: K-FLEX USA

PHONE: 800-765-6475

THE INFORMATION AND RECOMMENDATIONS SET FORTH HEREIN ARE BELIEVED TO BE
ACCURATE. BECAUSE SOME OF THE INFORMATION IS DERIVED FROM INFORMATION
PROVIDED FROM ITS SUPPLIERS, AND BECAUSE K-FLEX USA HAS NO CONTROL OVER THE
CONDITIONS OF HANDLING AND USE, K-FLEX USA MAKES NO WARRANTY, EXPRESSED OR
IMPLIED, REGARDING THE ACCURACY OF THE DATA OR THE RESULTS TO BE OBTAINED
FROM THE USE THEREOF. THE INFORMATION IS SUPPLIED SOLELY FOR YOUR
INFORMATION AND CONSIDERATION, AND K-FLEX USA ASSUMES NO RESPONSIBILITY FOR
USE OR RELIANCE THEREON. IT IS THE RESPONSIBILITY OF THE USER OF K-FLEX USA
PRODUCTS TO COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND
REGULATIONS.