Common Name: PCM18
Manufacturer: MICROTEK LABORATORIES
SDS Revision Date: 2/1/2015
SDS Format: GHS-US
   
Item Number(s): 49CT37, 49CT38
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1. PRODUCT AND COMPANY IDENTIFICATION 
2. HAZARDS IDENTIFICATION 
3. COMPOSITION/INFORMATION ON INGREDIENTS 
4. FIRST AID MEASURES 
5. FIRE FIGHTING MEASURES 
6. ACCIDENTAL RELEASE MEASURES 
7. HANDLING AND STORAGE 
8. EXPOSURE CONTROLS / PERSONAL PROTECTION 
9. PHYSICAL AND CHEMICAL PROPERTIES 
10. STABILITY AND REACTIVITY 
11. TOXICOLOGICAL INFORMATION 
12. ECOLOGICAL INFORMATION 
13. DISPOSAL CONSIDERATIONS 
14. TRANSPORT INFORMATION 
15. REGULATORY INFORMATION 
16. OTHER INFORMATION 



MICROTEK LABORATORIES, INC.

SAFETY DATA FOR PCM18


1. PRODUCT AND COMPANY IDENTIFICATION 


PRODUCT NAME: PCM18

DATE: FEBRUARY 2015

SYNONYM: NONE

CHEMICAL NAME: HYDROCARBON BLEND

COMPANY:
ERGODYNE 1021
BANDANA BOULEVARD EAST SUITE 220
SAINT PAUL, MN 55108
USA

PHONE: 651 642 9889 // 800 225 8238


2. HAZARDS IDENTIFICATION 


EMERGENCY OVERVIEW:

OSHA HAZARDS/GHS CLASSIFICATION:
ASPIRATION HAZARD (CATEGORY 1), H304 (SEE SECTION 16)

PICTOGRAM: EXCLAMATION MARK

SIGNAL WORD: DANGER

HAZARD STATEMENTS:
H304: MAY BE FATAL IF SWALLOWED AND ENTERS AIRWAYS

PRECAUTIONARY STATEMENTS:

P301, P310:
IF SWALLOWED: IMMEDIATELY CALL A POISON CENTER OR DOCTOR/PHYSICIAN

P331: DO NOT INDUCE VOMITING.

P405: STORE LOCKED UP.

P501: DISPOSE OF CONTENTS/CONTAINER TO AN APPROVED WASTE DISPOSAL PLANT.

HMIS CLASSIFICATION:
HEALTH HAZARD    0
FLAMMABILITY     1
PHYSICAL HAZARDS 0

NFPA RATING:
HEALTH HAZARD     0
FIRE              1
REACTIVITY HAZARD 0

POTENTIAL HEALTH EFFECTS:

INHALATION:
MAY BE HARMFUL IF INHALED. MAY CAUSE RESPIRATORY TRACT IRRITATION.

SKIN:
MAY BE HARMFUL IF ABSORBED THROUGH SKIN. MAY CAUSE SKIN IRRITATION OR
DRYNESS/CRACKING WITH REPEATED EXPOSURE.

EYES: MAY CAUSE EYE IRRITATION

INGESTION: MAY BE FATAL IF SWALLOWED AND ENTERS AIRWAYS.


3. COMPOSITION/INFORMATION ON INGREDIENTS 


NAME               CAS NUMBER  % BY WEIGHT

HYDROCARBON BLEND  8002-74-2   99 - 100


4. FIRST AID MEASURES 


GENERAL ADVICE:
CONSULT A PHYSICIAN. SHOW THIS SAFETY DATA SHEET TO THE DOCTOR IN
ATTENDANCE

IF INHALED:
MOVE PERSON INTO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION.

IN CASE OF SKIN CONTACT: WASH OFF WITH SOAP AND PLENTY OF WATER.

IN CASE OF EYE CONTACT: FLUSH EYES WITH WATER AS A PRECAUTION.

IF SWALLOWED:
DO NOT INDUCE VOMITING. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS
PERSON. RINSE MOUTH WITH WATER.


5. FIRE FIGHTING MEASURES 


EXTINGUISHER MEDIA:
USE WATER SPRAY, ALCOHOL-RESISTANT FOAM, DRY CHEMICAL, OR CARBON DIOXIDE.

SPECIAL REMARKS ON FIRE HAZARDS:
MATERIAL WILL FLOAT ON WATER. USE OF WATER ON BURNING MATERIAL MAY SPREAD
FIRE.

SPECIAL REMARKS ON EXPLOSION HAZARDS: NONE

SPECIAL HAZARDS ARISING FROM THE SUBSTANCE OR MIXTURE: CARBON OXIDES

ADVICE FOR FIREFIGHTERS:
WEAR SELF-CONTAINED BREATHING APPARATUS FOR FIREFIGHTING IF NECESSARY.


6. ACCIDENTAL RELEASE MEASURES 


PERSONAL PRECAUTIONS:
AVOID BREATHING VAPORS, MIST, OR GAS. USE PERSONAL PROTECTIVE EQUIPMENT.
ENSURE ADEQUATE VENTILATION. EVACUATE PERSONNEL TO SAFE AREAS. FOR PPE SEE
SECTION 8.

ENVIRONMENTAL PRECAUTIONS:
DO NOT LET PRODUCT ENTER DRAINS. PREVENT FURTHER LEAKAGE OR SPILLAGE IF
SAFE TO DO SO.

METHODS AND MATERIALS FOR CONTAINMENT AND CLEANING UP:
CONTAIN SPILLAGE, AND THEN COLLECT WITH NON-COMBUSTIBLE ABSORBENT MATERIAL
(SAND, EARTH, DIATOMACEOUS EARTH, VERMICULITE), AND PLACE IN CONTAINER FOR
DISPOSAL ACCORDING TO LOCAL/NATIONAL REGULATIONS (SEE SECTION 13). KEEP IN
SUITABLE, CLOSED CONTAINERS FOR DISPOSAL.


7. HANDLING AND STORAGE 


PRECAUTIONS:
AVOID CONTACT WITH SKIN AND EYES. AVOID INHALATION OF VAPOR OR MIST. KEEP
AWAY FROM SOURCES OF IGNITION. NO SMOKING. TAKE MEASURES TO PREVENT THE
BUILDUP OF ELECTROSTATIC CHARGE. KEEP CONTAINER TIGHTLY CLOSED IN A DRY AND
WELL-VENTILATED PLACE. CONTAINERS WHICH ARE OPENED MUST BE CAREFULLY
RESEALED AND KEPT UPRIGHT TO PREVENT LEAKAGE.


8. EXPOSURE CONTROLS / PERSONAL PROTECTION 


CONTAINS NO SUBSTANCES WITH OCCUPATIONAL EXPOSURE LIMIT VALUES.

APPROPRIATE ENGINEERING CONTROLS:
HANDLE IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE AND SAFETY PRACTICE. WASH
HANDS BEFORE BREAKS AND THE END OF WORKDAY.

PERSONAL PROTECTIVE EQUIPMENT:

RESPIRATORY PROTECTION:
WHERE RISK ASSESSMENT SHOWS AIR-PURIFYING RESPIRATORS ARE APPROPRIATE USE A
FULL-FACE RESPIRATOR WITH MULTI-PURPOSE COMBINATION (US) OR TYPE ABEK (EN
14387) RESPIRATOR CARTRIDGES AS A BACKUP TO ENGINEERING CONTROLS. IF THE
RESPIRATOR IS THE SOLE MEANS OF PROTECTION, USE A FULL-FACE SUPPLIED AIR
RESPIRATOR. USE RESPIRATORS AND COMPONENTS TESTED AND APPROVED UNDER
APPROPRIATE GOVERNMENT STANDARDS SUCH AS NIOSH (US) OR CEN (EU).

HAND PROTECTION:
HANDLE WITH GLOVES. GLOVES MUST BE INSPECTED PRIOR TO USE. USE PROPER GLOVE
REMOVAL TECHNIQUE (WITHOUT TOUCHING GLOVE'S OUTER SURFACE) TO AVOID SKIN
CONTACT WITH THIS PRODUCT. DISPOSE OF CONTAMINATED GLOVES AFTER USE IN
ACCORDANCE WITH APPLICABLE LAWS AND GOOD LABORATORY PRACTICES. WASH AND DRY
HANDS.

FACE/EYE PROTECTION:
FACE SHIELD AND SAFETY GLASSES. USE EQUIPMENT FOR EYE PROTECTION TESTED AND
APPROVED UNDER APPROPRIATE GOVERNMENT STANDARDS SUCH AS NIOSH (US) OR EN
166 (EU).

SKIN AND BODY PROTECTION:
HANDLE WITH GLOVES. CHOOSE BODY PROTECTION IN RELATION TO ITS TYPE, TO THE
CONCENTRATION AND AMOUNT OF DANGEROUS SUBSTANCES, AND TO THE SPECIFIC
WORKPLACE.


9. PHYSICAL AND CHEMICAL PROPERTIES 


APPEARANCE: COLORLESS LIQUID ABOVE APPROX. 18 DEG. C (64 DEG. F)

ODOR: SLIGHT WAXY ODOR

SOLUBILITY: INSOLUBLE TO VERY SLIGHT WATER SOLUBILITY

MELTING POINT: APPROX. 18 DEG. C (64 DEG. F)

THE FOLLOWING DATA ARE BASED UPON LITERATURE VALUES FOR SIMILAR COMPOUNDS;
PCM18 NOT TESTED FOR THE FOLLOWING:

BOILING POINT: 286 DEG. C

FLASH POINT: 135 DEG. C (275 DEG. F)

IGNITION TEMPERATURE: 215 DEG. C (419 DEG. F)

DENSITY: 0.77 G/CM3 AT 25 DEG. C (77 DEG. F)

VAPOR PRESSURE: <0.1 MBAR AT 20 DEG. C


10. STABILITY AND REACTIVITY 


STABILITY:
THIS PRODUCT IS STABLE UNDER NORMAL CONDITIONS OF HANDLING AND STORAGE.

INSTABILITY TEMPERATURE: NOT AVAILABLE

CONDITIONS OF INSTABILITY: HEAT, IGNITION SOURCES (FLAMES, SPARKS, ETC.)

INCOMPATIBILITY WITH VARIOUS SUBSTANCES: REACTIVE WITH OXIDIZING AGENTS

SPECIAL REMARKS ON REACTIVITY: NONE

CORROSIVITY: NOT AVAILABLE

POLYMERIZATION: WILL NOT OCCUR


11. TOXICOLOGICAL INFORMATION 


ACUTE TOXICITY: NO DATA AVAILABLE

SKIN CORROSION/IRRITATION: NO DATA AVAILABLE

SERIOUS EYE DAMAGE/EYE IRRITATION: NO DATA AVAILABLE

RESPIRATORY OR SKIN SENSITIZATION: NO DATA AVAILABLE

GERM CELL MUTAGENICITY: NO DATA AVAILABLE

CARCINOGENICITY:

IARC:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS PROBABLY, POSSIBLE, OR CONFIRMED HUMAN CARCINOGEN BY
IARC.

ACGIH:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY ACGIH.

NTP:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A KNOWN OR ANTICIPATED CARCINOGEN BY NTP.

OSHA:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY OSHA.

REPRODUCTIVE TOXICITY: NO DATA AVAILABLE.

SPECIFIC ORGAN TOXICITY - SINGLE EXPOSURE (GHS): NO DATA AVAILABLE

SPECIFIC ORGAN TOXICITY - REPEATED EXPOSURE (GHS): NO DATA AVAILABLE

ASPIRATION HAZARD: NO DATA AVAILABLE

POTENTIAL HEALTH EFFECTS:

INHALATION:
MAY BE HARMFUL IF INHALED. MAY CAUSE RESPIRATORY TRACT IRRITATION.

INGESTION: MAY BE HARMFUL IF SWALLOWED.

SKIN: MAY BE HARMFUL IF ABSORBED THROUGH SKIN. MAY CAUSE SKIN IRRITATION.

EYES: MAY CAUSE EYE IRRITATION.


12. ECOLOGICAL INFORMATION 


TOXICITY: NO DATA AVAILABLE

PERSISTENCE AND DEGRADABILITY: NO DATA AVAILABLE

BIOACCUMULATIVE POTENTIAL: NO DATA AVAILABLE

MOBILITY IN SOIL: NO DATA AVAILABLE

PBT AND VPVB ASSESSMENT: NO DATA AVAILABLE

OTHER ADVERSE EFFECTS: NO DATA AVAILABLE


13. DISPOSAL CONSIDERATIONS 


WASTE DISPOSAL:
OFFER SURPLUS AND NON-RECYCLABLE SOLUTIONS TO A LICENSED DISPOSAL COMPANY.

CONTAMINATED PACKAGING: DISPOSE OF AS UNUSED PRODUCT.


14. TRANSPORT INFORMATION 


DOT (US): NOT REGULATED AS DANGEROUS GOODS

IMDG: NOT REGULATED AS DANGEROUS GOODS

IATA: NOT REGULATED AS DANGEROUS GOODS


15. REGULATORY INFORMATION 


OSHA HAZARDS: COMBUSTIBLE LIQUID, TARGET ORGAN EFFECTS

DSL STATUS: ALL COMPONENTS OF THIS PRODUCT ARE ON THE CANADIAN DSL.

SARA 302 COMPONENTS:
NO CHEMICALS IN THIS MATERIAL ARE SUBJECT TO THE REPORTING REQUIREMENTS OF
SARA TITLE III, SECTION 302.

SARA 313 COMPONENTS:
THIS MATERIAL DOES NOT CONTAIN ANY CHEMICAL COMPONENTS WITH KNOWN CAS
NUMBERS THAT EXCEED THE THRESHOLD (DE MINIMIS) REPORTING LEVELS ESTABLISHED
BY SARA TITLE III, SECTION 313.

EUROPE REACH: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY.

USA TSCA: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY.

AUSTRALIA AICS: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY.

NEW ZEALAND NAIOC: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY.

JAPAN ENCS: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY.

KOREA KECI: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY.

PHILIPPINES PICCS: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY.

CHINA IECSC: ON THE INVENTORY, OR IN COMPLIANCE WITH THE INVENTORY.

MASSACHUSETTS RIGHT TO KNOW COMPONENTS:
NO COMPONENTS ARE SUBJECT TO THE MASSACHUSETTS RIGHT TO KNOW ACT

CALIFORNIA PROP. 65 COMPONENTS:
THIS PRODUCT DOES NOT CONTAIN ANY CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, OR ANY OTHER REPRODUCTIVE HARM.


16. OTHER INFORMATION 


FULL TEXT OF H-STATEMENTS REFERRED TO UNDER SECTION 2:
H304: MAY BE FATAL IF SWALLOWED AND ENTERS AIRWAYS

TO BEST OF OUR KNOWLEDGE, THE ABOVE INFORMATION IS CORRECT, BUT NO
GUARANTEE IS TO BE IMPLIED. THE PRODUCTS DISCUSSED ARE SOLD WITHOUT
WARRANTY, EXPRESS OR IMPLIED, ON THE CONDITION THAT THE PURCHASERS SHALL
MAKE THEIR OWN DETERMINATIONS OF SUITABILITY OF THE PRODUCT FOR THEIR
PURPOSES. NOTHING IN THIS BULLETIN SHALL BE CONSTRUED AS GRANTING
PERMISSION TO USE OR PRACTICE ANY INVENTION COVERED BY ANY PATENT.