Common Name: UP SERIES VALVE REGULATED LEAD ACID BATTERY
Manufacturer: UNIVERSAL POWER TECHNOLOGY CHINA
SDS Revision Date: 3/15/2017
SDS Format: ANSI-OSHA
   
Item Number(s): 4PG76
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1: PRODUCT AND COMPANY IDENTIFICATION 
SECTION 2: COMPOSITION / INFORMATION ON MAIN INGREDIENTS 
SECTION 3: PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 4: HAZARDS INDENTIFICATION 
SECTION 5: FIRST-AID MEASURES 
SECTION 6: FIRE FIGHTING MEASURES 
SECTION 7: ACCIDENTAL RELEASE MEASURES 
SECTION 8: HANDLING AND USE 
SECTION 9: EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION 10: TOXICOLOGICAL INFORMATION 
SECTION 11: ECOLOGICAL INFORMATION 
SECTION 12: DISPOSAL CONSIDERATIONS 
SECTION 13: STABILITY AND REACTIVITY 
SECTION 14: TRANSPORTATION INFORMATION 
SECTION 15: REGULATORY INFORMATION 
SECTION 16: OTHER INFORMATION 



SAFETY DATA SHEET

VALVE REGULATED LEAD ACID BATTERY

FILE VER: 2.0

MSDS DATE: MAR 15, 2017


SECTION 1: PRODUCT AND COMPANY IDENTIFICATION 


CHEMICAL/TRADE NAME (AS USED LABEL):
+BATTERYCENTER-
INCLUDING RANGES AS
UP SERIES VALVE REGULATED LEAD ACID BATTERY

VALVE REGULATED LEAD ACID BATTERY IS FILLED WITH DILUTE SULPHURIC ACID.

MANUFACTURER'S NAME/ADDRESS:

MANUFACTURER: UNIVERSAL POWER TECHNOLOGY CO., LTD.

ADDRESS:
MEILONG ROAD, LONG HUA TOWN, BAO'AN DISTRICT
SHENZHEN CHINA 518131

TELEPHONE:
EMERGENCY PHONE: +86 755 28094189
FAX PHONE: +86 755 83722565

CHEMICAL FAMILY/CLASSIFICATION: UP SERIES VALVE REGULATED LEAD ACID BATTERY


SECTION 2: COMPOSITION / INFORMATION ON MAIN INGREDIENTS 


EINECS#     CAS NR.     DESCRIPTION        CONTENT(UNIT)*1   SYMBOL AND
                                                             CLASSIFICATION

231-100-4   7439-92-1   LEAD GRID          APPROX. 34 WT%    T (TOXIC)
                        (PURE LEAD AND                       R50/53
                        LEAD ALLOYS WITH
                        TRACES OF AS)

215-267-0   7439-92-1   ACTIVE MASS        APPROX. 31 WT%    T (TOXIC)
                        (LEAD CONTAINING                     R61-20/22-
                        BATTERY PASTE)                       33-62
                                                             R50/53

231-639-5   7664-93-9   ELECTROLYE         APPROX. 34 WT%    C (CORROSIVE)
                        (SULPHURIC ACID                      R35
                        WITH ADDITIVES)

*1) CONTENTS MAY VARY


SECTION 3: PHYSICAL AND CHEMICAL PROPERTIES 


                        LEAD             SULPHURIC ACID (30% TO 38.5 WT%)

APPEARANCE:

FORM                    SOLID            LIQUID

COLOR                   GREY             COLOURLESS

ODOUR                   ODOURLESS        ODOURLESS

SAFETY- RELATED DATA:

SOLIDIFICATION POINT    327 DEG. C       -35 TO -60 DEG. C

BOILING POINT           1740 DEG. C      APPROX. 108 TO 114 DEG. C

SOLUBILITY IN WATER     VERY LOW         COMPLETE
                        (0.15 MG/L)

DENSITY (20 DEG. C)     11.35 G/CM3      1.2 TO 1.3 G/CM3

VAPOUR PRESSURE         N.A.             N.A.
(20 DEG. C)

LEAD AND LEAD-CONTAINING BATTERY PASTE ARE POORLY SOLUBLE IN WATER.

LEAD CAN BE DISSOLVED IN AN ACIDIC OR ALKALINE ENVIRONMENT.


SECTION 4: HAZARDS INDENTIFICATION 


NO HAZARDS IN CASE OF AN INTACT BATTERY AND OBSERVATION OF THE INSTRUCTIONS
FOR USE.

VALVE REGULATED LEAD/ACID BATTERIES HAVE THREE SIGNIFICANT CHARACTERISTICS:
THEY CONTAIN DILUTE SULPHURIC ACID, WHICH MAY CAUSE SEVERE ACID BURNS;

DURING THE CHARGING PROCESS THEY DEVELOP HYDROGEN GAS AND OXYGEN, WHICH
UNDER CERTAIN CIRCUMSTANCES MAY RESULT IN AN EXPLOSIVE MIXTURE

THEY CAN CONTAIN A CONSIDERABLE AMOUNT OF ENERGY WHICH MAY BE A SOURCE OF
HIGH ELECTRICAL CURRENT AND SEVERE ELECTRICAL SHOCK IN THE EVENT OF A SHORT
CIRCUIT.


SECTION 5: FIRST-AID MEASURES 


THIS INFORMATION IS OF RELEVANCE ONLY IF THE BATTERY IS BROKEN AND DIRECT
CONTACT WITH THE COMPOUNDS OCCURS.

GENERAL INFORMATION:
SULPHURIC ACID ACTS CORROSIVELY AND DAMAGES SKIN.

LEAD-CONTAINING BATTERY PASTE IS CLASSIFIED AS TOXIC REPRODUCTION IF
SWALLOWED).

LEAD-CONTAINING BATTERY PASTE:
AFTER CONTACT WITH SKIN: CLEAN WITH WATER AND SOAP

SULPHURIC ACID:
AFTER INHALATION OF ACID MIST*): INHALE FRESH AIR

AFTER CONTACT WITH THE EYES*):
RINSE WITH WATER, REMOVE AND WASH WETTED CLOTHING

AFTER SWALLOWING*):
DRINK A LOT OF WATER INNEDIATELY, AND SWALLOW ACTIVATED CARBON, DO NOT
INDUCE VOMITING

*) SEEK THE ADVICE OF A DOCTOR


SECTION 6: FIRE FIGHTING MEASURES 


SUITABLE FIRE EXTINGUISHING AGENTS: CO2 OR DRY POWDER EXTINGUISHING AGENT

UNSUITABLE EXTINGUISHING AGENTS:
WATER IN THE CASE OF BATTERY VOLTAGES OF OVER 120 V

SPECIAL PROTECTIVE EQUIPMENT:
PROTECTIVE GOGGLES, RESPIRATORY PROTECTIVE EQUIPMENT, ACID PROTECTIVE
EQUIPMENT, ACID-PROOF CLOTHING IN CASE OF LARGER STATIONARY BATTERY PLANTS
OR WHERE LARGER QUANTITIES ARE STORED.


SECTION 7: ACCIDENTAL RELEASE MEASURES 


CLEANING / TAKE-UP PROCEDURES:
USE A BONDING AGENT, SUCH AS SAND, TO ABSORB SPILT ACID; USE LIME / SODIUM
CARBONATE FOR NEUTRALISATION; DISPOSE OF WITH DUE REGARD TO THE OFFICIAL
LOCAL REGULATIONS; DO NOT PERMIT PENETRATION INTO THE SEWAGE SYSTEM, THE
EARTH OR WATER BODIES.


SECTION 8: HANDLING AND USE 


SPILL OR LEAK PROCEDURES:
STOP FLOW OF MATERIAL, CONTAIN/ABSORB SMALL SPILLS WITH DRY SAND, EARTH,
OR VERMICULITE. DO NOT USE COMBUSTIBLE MATERIALS. IF POSSIBLE, CAREFULLY
NEUTRALIZE SPILLED ELECTROLYTE WITH SODA ASH, SODIUM BICARBONATE, LIME,
ETC. WEAR ACID-RESISTANT CLOTHING, BOOTS, GLOVES, AND FACE SHIELD. DO NOT
ALLOW DISCHARGE OF UNNEUTRALIZED ACID TO SEWER.

WASTE DISPOSAL METHODS:

SPENT BATTERIES: SEND TO SECONDARY LEAD SMELTER FOR RECYCLING.

PLACE NEUTRALIZED SLURRY INTO SEALED CONTAINERS AND HANDLE AS APPLICABLE
WITH STATE AND FEDERAL REGULATIONS. LARGE WATER-DILUTED SPILLS, AFTER
NEUTRALIZATION AND TESTING, SHOULD BE MANAGED IN ACCORDANCE WITH APPROVED
LOCAL, STATE, AND FEDERAL REQUIREMENTS. CONSULT STATE ENVIRONMENTAL AGENCY
AND/OR FEDERAL EPA.

HANDLING AND STORAGE:
STORE BATTERIES IN COOL, DRY, WELL-VENTILATED AREAS WITH IMPERVIOUS
SURFACES AND ADEQUATE CONTAINMENT IN THE EVENT OF SPILLS. BATTERIES SHOULD
ALSO BE STORED UNDER ROOF FOR PROTECTION AGAINST ADVERSE WEATHER
CONDITIONS. SEPARATE FROM INCOMPATIBLE MATERIALS. STORE AND HANDLE ONLY
IN AREAS WITH ADEQUATE WATER SUPPLY AND SPILL CONTROL. AVOID DAMAGE TO
CONTAINERS. KEEP AWAY FROM FIRE, SPARKS, AND HEAT.


SECTION 9: EXPOSURE CONTROLS/PERSONAL PROTECTION 


NO EXPOSURE TO LEAD AND LEAD-CONTAINING BATTERY PASTE DURING NORMAL
CONDITIONS OF USE.

POSSIBLE EXPOSURE TO SULPHURIC ACID AND ACID MIST DURING FILLING AND
CHARGING.

THRESHOLD VALUE IN WORKPLACE:
THE OCCUPATIONAL EXPOSURE LIMIT TO SULPHURIC ACID MIST IS REGULATED ON
A NATIONAL BASIS

HAZARD SYMBOL: C, CORROSIVE

PERSONAL PROTECTIVE EQUIPMENT:
RUBBER OR PVC GLOVES, ACID-PROOF GOGGLES, ACID-PROOF CLOTHING, SAFETY
BOOTS.


SECTION 10: TOXICOLOGICAL INFORMATION 


TOXICOLOGICAL INFORMATION:

SULFURIC ACID:
IS INTENSELY CORROSIVE TO SKIN AND MUCOUS MEMBRANES; THE INHALATION OF
MISTS MAY CAUSE DAMAGE TO THE RESPIRATORY TRACT.

ACUTE TOXICITY DATA:
LD50 (ORAL, RAT): 2140 MG/KG
LC50 (INHALATION, RAT): 510 MG/MV2H.

LEAD AND LEAD COMPOUNDS:
MAY CAUSE DAMAGE TO THE BLOOD, NERVES, AND KIDNEYS WHEN INGESTED;
LEAD-CONTAINING BATTERY PASTE IS CLASSIFIED AS TOXIC FOR REPRODUCTION.

SECTION 10 NOTES:
NOT APPLICABLE TO THE FINISHED PRODUCT 'LEAD-ACID' BATTERY, ONLY APPLICABLE
TO ITS COMPOUNDS IN CASE OF A BROKEN BATTERY. DIFFERENT EXPOSURE LIMITS
EXIST ON NATIONAL LEVEL.


SECTION 11: ECOLOGICAL INFORMATION 


THIS INFORMATION IS OF RELEVANCE IF THE BATTERY IS BROKEN AND THE CONTENTS
ARE RELEASED TO THE ENVIRONMENT.

LEAD AND LEAD COMPOUNDS:
CHEMICAL AND PHYSICAL TREATMENT IS REQUIRED FOR ELIMINATION FROM WATER.
WASTE WATER CONTAINING LEAD MUST NOT BE DISPOSED OF IN AN UNTREATED
CONDITION.

SULPHURIC ACID:
IN ORDER TO AVOID DAMAGE TO THE SEWAGE SYSTEM, THE ACID HAS TO BE
NEUTRALISED BY MEANS OF LIME OR SODIUM CARBONATE BEFORE DISPOSAL.
ECOLOGICAL DAMAGE IS POSSIBLE BY CHANGE OF PH.

THE ELECTROLYTE SOLUTION REACTS WITH WATER AND ORGANIC SUBSTANCES, CAUSING
DAMAGE TO FLORA AND FAUNA. THE BATTERIES ALSO CONTAIN SOLUBLE COMPONENTS OF
LEAD THAT CAN BE TOXIC TO AQUATIC ENVIRONMENTS.


SECTION 12: DISPOSAL CONSIDERATIONS 


THE POINTS OF SALE, THE MANUFACTURERS AND IMPORTERS OF BATTERIES,
RESPECTIVELY THE METAL DEALERS TAKE BACK SPENT BATTERIES, AND RENDER THEM
TO THE SECONDARY LEAD SMELTERS FOR PROCESSING.

SPENT LEAD-ACID BATTERIES (EUC 160601) ARE SUBJECT TO REGULATION 91/157/EC
(BATTERY DIRECTIVE) AND NATIONAL REGULATIONS ON THE COLLECTION OF
BATTERIES.


SECTION 13: STABILITY AND REACTIVITY 

            OF SULPHURIC ACID(30-38.5%)

CORROSIVE, NON-FLAMMABLE LIQUID

THERMAL DECOMPOSITION AT 338 DEG. C

DESTROYS ORGANIC MATERIALS, SUCH AS CARDBOARD, WOOD, TEXTILES.

REACTS WITH METALS PRODUCING HYDROGEN.

VIGOROUS REACTIONS WITH ALKALIS.


SECTION 14: TRANSPORTATION INFORMATION 


LAND TRANSPORT:
LAND TRANSPORT (ADR/RID, U.S. DOT):
UN NO: UN2800
CLASSIFICATION ADR/RID: CLASS 8
PROPER SHIPPING NAME: BATTERIES, WET, NON SPILLABLE ELECTRIC STORAGE
PACKING GROUP ADR: NOT ASSIGNED
LABEL REQUIRED: CORROSIVE
ADR/RID: NEW BATTERIES ARE EXEMPT FROM ALL ADR/RID (SPECIAL PROVISION 598).

SEA TRANSPORT:
SEA TRANSPORT (IMDG CODE):
UN NO: UN2800
CLASSIFICATION: CLASS 8
PROPER SHIPPING NAME: BATTERIES, WET, NON SPILLABLE ELECTRIC STORAGE
PACKING GROUP: III
EMS: F-A, S-B
LABEL REQUIRED: CORROSIVE

IF NON-SPIILABLE BATTERIES MEET THE SPECIAL PROVISION 238, THEY ARE EXEMPT
FROM ALL IMDG CODES PROVIDED THAT THE BATTERIES' TERMINALS ARE PROTECTED
AGAINST SHORT CIRCUITS.

AIR TRANSPORT (IATA-DGR):
AIR TRANSPORT (IATA-DGR):
UN NO: UN2800
CLASSIFICATION: CLASS 8
PROPER SHIPPING NAME: BATTERIES, WET, NON SPILLABLE ELECTRIC STORAGE
PACKING GROUP: III
LABEL REQUIRED: CORROSIVE

IF NON-SPILIABLE BATTERIES MEET THE SPECIAL PROVISION A67, THEY ARE EXEMPT
FROM ALL IATA DGR PROVIDED THAT THE BATTERIES' TERMINALS ARE PROTECTED
AGAINST SHORT


SECTION 15: REGULATORY INFORMATION 


IN ACCORDANCE WITH EU AND NATIONAL LAW, LEAD-ACID BATTERIES HAVE TO BE
MARKED BY A CROSSED OUT REFUSE BIN WITH THE CHEMICAL SYMBOL FOR LEAD PB
SHOWN BELOW., TOGETHER WITH THE ISO RETURN/RECYCLING SYMBOL.

PB

IN ADDITION THE 6 HAZARDOUS SYMBOLS DESCRIBED BELOW HAVE TO BE PRESENT:
NO SMOKING, NO OPEN FLAMES, NO SPARKS
WEAR SAFETY GOGGLES
KEEP AWAY FROM CHILDREN
SULPHURIC ACID
OBSERVE OPERATING INSTRUCTIONS
EXPLOSICE GAS MIXTURE

THE MANUFACTURER, RESPECTIVELY THE IMPORTER OF THE BATTERIES SHALL BE
RESPONSIBLE FOR THE ATTACHMENT OF THE SYMBOLS (A MINIMUM SIZE IS
SPECIFIED). IN ADDITION, CONSUMER/USER INFORMATION ON THE SIGNIFICANCE
OF THE SYMBOLS MAY BE ATTACHED.


SECTION 16: OTHER INFORMATION 


THE INFORMATION GIVEN ABOVE IS PROVIDED IN GOOD FAITH BASED ON EXISTING
KNOWLEDGE AND DOES NOT CONSTITUTE AN ASSURANCE OF SAFETY UNDER ALL
CONDITIONS. IT IS THE USER'S RESPONSIBILITY TO OBSERVE ALL LAWS AND
REGULATIONS APPLICABLE FOR STORAGE, USE, MAINTENANCE OR DISPOSAL OF THE
PRODUCT. IF THERE ARE ANY QUERIES, UNIVERSAL POWER TECHNOLOGY CO., LTD
AND THE AGENTS SHOULD BE CONSULTED.