SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. P+S(R*) POWER-STATIONS POWER STATIONS LIMITED NO.40, SHATIAN NORTH ROAD KENGZI, PINGSHAN NEW AREA, SHENZHEN (PC:518122) CHINA TEL: 86-755-89399681 FAX: 86-755-84278982 REPORT ID: PS-MSDS-NM001 MSDS REPORT SAMPLE DESCRIPTION: NICKEL METAL HYDRIDEBATTERY APPLICANT: POWER STATIONS LIMITED DATE: 2016-01-15 REPORT ID: PS-MSDS-NM001 PRODUCT: NICKEL METAL HYDRIDE BATTERY REV: 0
PRODUCT NAME: NICKEL METAL HYDRIDE BATTERY MODEL: PRISMATIC TYPE CELLS NOMINAL VOLTAGE: 1.2 V CHEMICAL SYSTEM: Ni-MH DESIGNED FOR RECHARGE: YES (X) NO ( )
IMPORTANT NOTE: THE PRODUCT IS A MANUFACTURED ARTICLE AS DESCRIBED IN 29 CFR 1919.1200. THE BATTERY CELL IS CONTAINED IN A HERMETICALLY-SEALED CASE, DESIGNED TO WITHSTAND TEMPERATURES AND PRESSURES ENCOUNTERED DURING NORMAL USE. AS A RESULT, DURING NORMAL USE, HAZARDOUS MATERIALS ARE FULLY CONTAINED INSIDE THE BATTERY CELL. THE BATTERY CELL SHOULD NOT BE OPENED OR EXPOSED TO HEAT BECAUSE EXPOSURE TO THE FOLLOWING INGREDIENTS CONTAINED WITHIN COULD BE HARMFUL UNDER SOME CIRCUMSTANCES. THE FOLLOWING INFORMATION IS PROVIDED FOR THE USER'S INFORMATION ONLY. CHEMICAL NAME CAS NO. OSHA PEL (MG/M3) ACGIH TLV (MG/M3) NICKEL (FOAM) 7440-02-0 1 TWA 1 TWA NICKEL HYDROXIDE 12054-48-7 1 TWA 1 TWA COBALT 7440-48-4 0.1 TWA DUST & FUME 0.005 ZINC 7440-66-6 5 TWA NA COPPER NET 7440-50-8 0.1 (FUME) 1 (DUST) 0.2 (FUME) 1 (DUST) NEODYMIUM 7440-00-8 NA NA POTASSIUM HYDROXIDE 1310-58-3 NA NA LITHIUM HYDROXIDE 1310-65-2 NA NA SODIUM HYDROXIDE 1310-73-2 NA NA NOTES: 1. CONCENTRATIONS VARY DEPENDING ON THE STATE OF CHARGE OR DISCHARGE 2. TWA IS THE TIME WEIGHTED AVERAGE CONCENTRATION OVER AN 8-HOUR PERIOD.
MELTING POINT (DEG. F): NA BOILING POINT (DEG. F): NA % VOLATILE BY VOLUME: NA MELTING POINT (DEG. F): NA BOILING POINT: (DEG. F) NA VAPOR PRESSURE (MM Hg): NA EVAPORATION RATE: VAPOR DENSITY (AIR = 1): NA VAPOR PRESSURE (MM Hg): NA EVAPORATION RATE: SPECIFIC GRAVITY (H2O): NA SOLUBILITY IN WATER: NA APPEARANCE AND ODOR: NO ODOR SPECIFIC GRAVITY (H2O): NA SOLUBILITY IN WATER: NA MELTING POINT (DEG. F): NA BOILING POINT (DEG. F): NA % VOLATILE BY VOLUME: NA MELTING POINT (DEG. F): NA BOILING POINT (DEG. F): NA
FLASH POINT: NA LOWER EXPLOSIVE LIMIT: NA UPPER EXPLOSIVE LIMIT: NA EXTINGUISHING MEDIA: ANY CLASS OF EXTINGUISHING MEDIUM MAY BE USED ON THE BATTERIES OR THEIR PACKING MATERIAL. SPECIAL FIRE FIGHTING PROCEDURES: EXPOSURE TO TEMPERATURES OF ABOVE 212 DEG. F CAN CAUSE VENTING OF THE LIQUID ELECTROLYTE. INTERNAL SHORTING COULD ALSO CAUSE VENTING OF THE ELECTROLYTE. THERE IS POTENTIAL FOR EXPOSURE TO IRON, NICKEL, COBALT, RARE EARTH METALS (CERIUM, LANTHANUM NEODYMIUM, AND PRASEODYMIUM), MANGANESE, AND ALUMINUM FUMES DURING FIRE; USE SELF-CONTAINED BREATHING APPARATUS.
THRESHOLD LIMIT VALUES: SEE SECTION II EFFECTS OF A SINGLE (ACUTE) OVEREXPOSURE: INHALATION: DURING NORMAL USE INHALATION IS AN UNLIKELY ROUTE OF EXPOSURE DUE TO CONTAINMENT OF HAZARDOUS MATERIALS WITHIN THE BATTERY CASE. HOWEVER, SHOULD THE BATTERIES BE EXPOSED TO EXTREME HEAT OR PRESSURES CAUSING A BREACH IN THE BATTERY CELL CASE, EXPOSURE TO THE CONSTITUENTS MAY OCCUR. INHALATION OF COBALT DUSTS MAY RESULT IN PULMONARY CONDITIONS. INGESTION: IF THE BATTERY CASE IS BREACHED IN THE DIGESTIVE TRACT, THE ELECTROLYTE MAY CAUSE LOCALIZED BURNS. SKIN ABSORPTION: NO EVIDENCE OF ADVERSE EFFECTS FROM AVAILABLE DATA. SKIN CONTACT: EXPOSURE TO THE ELECTROLYTE CONTAINED INSIDE THE BATTERY MAY RESULT IN CHEMICAL BURNS. EXPOSURE TO NICKEL MAY CAUSE DERMATITIS IN SOME SENSITIVE INDIVIDUALS. EYE CONTACT: EXPOSURE TO THE ELECTROLYTE CONTAINED INSIDE THE BATTERY MAY RESULT IN SEVERE IRRITATION AND CHEMICAL BURNS. CARCINOGENICITY: NICKEL HAS BEEN IDENTIFIED BY THE NATIONAL TOXICOLOGY PROGRAM (NTP) AS REASONABLY ANTICIPATED TO BE A CARCINOGEN. COBALT HAS BEEN IDENTIFIED BY IARC AS A 2B CARCINOGEN. OTHER EFFECTS OF REPEATED (CHRONIC) EXPOSURE: CHRONIC OVEREXPOSURE TO NICKEL MAY RESULT IN CANCER; DERMAL CONTACT MAY RESULT IN DERMATITIS IN SENSITIVE INDIVIDUALS. MEDICAL CONDITIONS AGGRAVATED BY OVEREXPOSURE: A KNOWLEDGE OF THE AVAILABLE TOXICOLOGY INFORMATION AND OF THE PHYSICAL AND CHEMICAL PROPERTIES OF THE MATERIAL SUGGESTS THAT OVEREXPOSURE IN UNLIKELY TO AGGRAVATE EXISTING MEDICAL CONDITIONS. EMERGENCY AND FIRST AID PROCEDURES: SWALLOWING: DO NOT INDUCE VOMITING. SEEK MEDICAL ATTENTION IMMEDIATELY. SKIN: IF THE INTERNAL CELL MATERIALS OF AN OPENED BATTERY CELL COME INTO CONTACT WITH THE SKIN, IMMEDIATELY FLUSH WITH WATER FOR AT LEAST 15 MINUTES. INHALATION: IF POTENTIAL FOR EXPOSURE TO FUMES OR DUSTS OCCURS, REMOVE IMMEDIATELY TO FRESH AIR AND SEEK MEDICAL ATTENTION. EYES: IF THE CONTENTS FROM AN OPENED BATTERY COME INTO CONTACT WITH THE EYES, IMMEDIATELY FLUSH EYES WITH WATER CONTINUOUSLY FOR AT LEAST 15 MINUTES. SEEK MEDICAL ATTENTION.
THE BATTERIES ARE STABLE UNDER NORMAL OPERATING CONDITIONS. HAZARDOUS POLYMERIZATION WILL NOT OCCUR. HAZARDOUS DECOMPOSITION PRODUCTS: OXIDES OF NICKEL, COBALT, MANGANESE, LANTHANUM, AND CERIUM. CONDITIONS TO AVOID: HEAT, OPEN FLAMES, SPARKS, AND MOISTURE. POTENTIAL INCOMPATIBILITIES (I.E., MATERIALS TO AVOID CONTACT WITH): THE BATTERY CELLS ARE ENCASED IN A NON-REACTIVE CONTAINER; HOWEVER, IF THE CONTAINER IS BREACHED, AVOID CONTACT OF INTERNAL BATTERY COMPONENTS WITH ACIDS, ALDEHYDES, AND CARBAMATE COMPOUNDS.
SPILL AND LEAKS ARE UNLIKELY BECAUSE CELLS ARE CONTAINED IN A HERMETICALLY-SEALED CASE. IF THE BATTERY CASE IS BREACHED, DON PROTECTIVE CLOTHING THAT IS IMPERVIOUS TO CAUSTIC MATERIALS AND ABSORB OR PACK SPILL RESIDUES IN INERT MATERIAL. DISPOSE IN ACCORDANCE WITH APPLICABLE STATE AND FEDERAL REGULATIONS.
VENTILATION REQUIREMENTS: NOT REQUIRED UNDER NORMAL USE. RESPIRATORY PROTECTION: NOT REQUIRED UNDER NORMAL USE. EYE PROTECTION: NOT REQUIRED UNDER NORMAL USE. GLOVES: NOT REQUIRED UNDER NORMAL USE.
STORAGE: STORE IN A COOL PLACE, BUT PREVENT CONDENSATION ON CELL OR BATTERY TERMINALS. ELEVATED TEMPERATURES MAY RESULT IN REDUCED BATTERY LIFE. OPTIMUM STORAGE TEMPERATURES ARE BETWEEN -31 DEG. F AND 95 DEG. F. MECHANICAL CONTAINMENT: IF THERE IS SPECIAL ENCAPSULATION OR SEALING REQUIREMENTS, CONSULT YOUR BFN BATTERY CO., LTD REPRESENTATIVE ABOUT POSSIBLE CELL HAZARD PRECAUTIONS OR LIMITATIONS. HANDLING: ACCIDENTAL SHORT CIRCUIT WILL BRING HIGH TEMPERATURE ELEVATION TO THE BATTERY AS WELL AS SHORTEN THE BATTERY LIFE. BE SURE TO AVOID PROLONGED SHORT CIRCUIT SINCE THE HEAT CAN BURN ATTENDANT SKIN AND EVEN RUPTURE OF THE BATTERY CELL CASE. BATTERIES PACKAGED IN BULK CONTAINERS SHOULD NOT BE SHAKEN. METAL COVERED TABLES OR BELTS USED FOR ASSEMBLY OF BATTERIES INTO DEVICES CAN BE THE SOURCE OF SHORT CIRCUITS; APPLY INSULATING MATERIAL TO ASSEMBLY WORK SURFACE. IF SOLDERING OR WELDING TO THE CASE OF THE BATTERY IS REQUIRED, CONSULT YOUR BFN BATTERY CO., LTD. REPRESENTATIVE FOR PROPER PRECAUTIONS TO PREVENT SEAL DAMAGE OR EXTERNAL SHORT CIRCUIT. CHARGING: THIS BATTERY IS DESIGNED FOR RECHARGING. A LOSS OF VOLTAGE AND CAPACITY OF BATTERIES DUE TO SELF-DISCHARGE DURING PROLONGED STORAGE IS UNAVOIDABLE. CHARGE BATTERY BEFORE USE. OBSERVE THE SPECIFIED CHARGE RATE SINCE HIGHER RATES CAN CAUSE A RISE IN INTERNAL GAS PRESSURE THAT MAY RESULT IN DAMAGING HEAT GENERATION OR CELL RUPTURE AND/OR VENTING. LABELING: IF NORMAL LABEL WARNINGS ARE NOT VISIBLE, IT IS IMPORTANT TO PROVIDE A DEVICE LABEL STATING: CAUTION: DO NOT DISPOSE IN FIRE, MIX WITH OTHER BATTERY TYPES, CHARGE ABOVE SPECIFIED RATE, CONNECT IMPROPERLY, OR SHORT CIRCUIT, WHICH MAY RESULT IN OVERHEATING, EXPLOSION OR LEAKAGE OF CELL CONTENTS.
POWER STATIONS, LTD ENCOURAGES BATTERY RECYCLING. OUR NICKEL METAL HYDRIDE BATTERIES ARE NOT DEFINED BY THE LOCAL GOVERNMENT AS HAZARDOUS WASTE AND ARE SAFE FOR DISPOSAL IN THE NORMAL MUNICIPAL WASTE STREAM. DO NOT INCINERATE OR SUBJECT BATTERY CELLS TO TEMPERATURES IN EXCESS OF 212 DEG. F. SUCH TREATMENT CAN CAUSE CELL RUPTURE.
POWER STATIONS, LTD SEALED NICKEL METAL HYDRIDE BATTERY ARE CONSIDERED TO BE "DRY CELL" BATTERIES AND ARE NOT SUBJECT TO DANGEROUS GOODS REGULATION FOR THE PURPOSE OF TRANSPORTATION BY THE U.S. DEPARTMENT OF TRANSPORTATION (DOT), THE INTERNATIONAL CIVIL AVIATION ORGANIZATION (ICAO), THE INTERNATIONAL AIR TRANSPORT ASSOCIATION (IATA) OR THE INTERNATIONAL MARITIME DANGEROUS GOODS REGULATIONS (IMDG). MORE INFORMATION CONCERNING SHIPPING, TESTING, MARKING AND PACKAGING CAN BE OBTAINED FROM POWER STATIONS LTD. REPRESENTATIVES. THE ONLY DOT REQUIREMENT FOR SHIPPING NICKEL METAL HYDRIDE BATTERIES IS SPECIAL PROVISION A123 WHICH STATES: "BATTERIES, DRY ARE NOT SUBJECT TO THE REQUIREMENTS OF THIS SUBCHAPTER ONLY WHEN THEY ARE OFFERED FOR TRANSPORTATION IN A MANNER THAT PREVENTS THE DANGEROUS EVOLUTION OF HEAT (FOR EXAMPLE, BY THE EFFECTIVE INSULATION OF EXPOSED TERMINALS)." IATA REQUIRES THAT BATTERIES BEING TRANSPORTED BY AIR MUST BE PROTECTED FROM SHORT-CIRCUITING AND PROTECTED FROM MOVEMENT THAT COULD LEAD TO SHORT-CIRCUITING. SUCH BATTERIES HAVE BEEN PACKED IN INNER PACKAGING IN SUCH A MANNER AS TO EFFECTIVELY PREVENT SHORT CIRCUITS AND TO PREVENT MOVEMENT WHICH COULD LEAD TO SHORT CIRCUITS. 304 OF IMDG: BATTERIES, DRY, CONTAINING CORROSIVE ELECTROLYTE WHICH WILL NOT FLOW OUT OF THE BATTERY IF THE BATTERY CASE IS CRACKED ARE NOT SUBJECT TO THE PROVISIONS OF THIS CODE PROVIDED THE BATTERIES ARE SECURELY PACKED AND PROTECTED AGAINST SHORT-CIRCUITS. EXAMPLES OF SUCH BATTERIES ARE: ALKALI-MANGANESE, ZINC-CARBON, NICKEL-METAL HYDRIDE AND NICKEL-CADMIUM BATTERIES.
FIRST AID PROCEDURES: IF ELECTROLYTE LEAKAGE OCCURS AND MAKES CONTACT WITH SKIN, PLEASE WASH IT WIT PLENTY OF WATER IMMEDIATELY IF ELECTROLYTE COMES INTO WITH EYES, WASH EYES WITH COPIOUS AMOUNT OF WATER FOR 15 MINUTES AND CONTACT A PHYSICIAN IF ELECTROLYTE VAPOR ARE INHALED, PROVIDES FRESH AIR AND SEEK MEDICAL ATTENTION IF RESPIRATORY IRRITATION DEVELOPS, VENTILATE THE CONTAMINATED AREA
N.A.
SPECIAL REQUIREMENTS BE ACCORDING TO THE LOCAL REGULATORY
SYMBOL: N/A EC LABELING: NONE RISK PHRASES: NONE SAFETY PHRASES: NONE
IN CASE OF FIRE, IT IS PERMISSIBLE TO USE ANY CLASS OF EXTINGUISHING MEDIUM ON THESE BATTERIES OR THEIR PACK MATERIAL. COOL EXTERIOR IF EXPOSED TO FIRE TO PREVENT RUPTURE. FIRE FIGHTERS SHOULD WEAR SELF-CONTAINED BREATHING APPARATUS FOR AND BEHALF OF: POWER STATIONS LIMITED AUTHORIZED SIGNATURE(S): YOYO LU |