SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. GP BATTERIES SAFETY DATA SHEET MODEL NO.: GN1604S DOCUMENT NUMBER: GPBC-MS-S001 REVISION: 05 IDENTITY (AS USED ON LABEL AND LIST): GN1604S NOTE: BLANK SPACES ARE NOT PERMITTED IF ANY ITEM IS NOT APPLICABLE OR NO INFORMATION IS AVAILABLE, THE SPACE MUST BE MARKED TO INDICATE THAT.
MANUFACTURER'S NAME: GPI INTERNATIONAL LTD. ADDRESS (NUMBER, STREET, CITY STATE, AND ZIP CODE): 7/F , BUILDING 16W, 16 SCIENCE PARK WEST AVENUE HONG KONG SCIENCE PARK, NEW TERRITORIES, HONG KONG EMERGENCY TELEPHONE NUMBER: TELEPHONE NUMBER FOR INFORMATION: 852-2484-3333 DATE OF PREPARED AND REVISION: ISSUE DATE: JAN 01,2020 SIGNATURE OF PREPARER (OPTIONAL):
HAZARDOUS COMPONENTS: DESCRIPTION APPROXIMATE % CAS NO. REMARKS OF TOTAL WEIGHT MERCURY (Hg) <1.0 PPM 7439-97-6 IMPURITY LEAD (Pb) <1000 PPM 7439-92-1 ADDED IN ZINC PLATE CADMIUM (Cd) <10 PPM 7440-43-9 IMPURITY HEXAVALENT CHROMIUM (Cr6+) <10 PPM 7440-47-3 IMPURITY POLYBROMINATED BIPHENYLS N/A (PBBS) POLYBROMINATED DIPHENYL N/A ETHERS (PBDES) ZINC CHLORIDE (ZnCl2) 2-10 WT% 7646-85-7 AMMONIUM CHLORIDE (NH4Cl) 0-10 WT% 2125-02-9 MANGANESE DIOXIDE (MnO2) 25-35 WT% 1313-13-9 ZINC (Zn) 10-20 WT% 7440-66-6 ACETYLENE BLACK 5-15 WT% 1333-86-4
BOILING POINT: N.A. SPECIFIC GRAVITY (H2O=1): N.A. VAPOR PRESSURE (MMHg): N.A. MELTING POINT: N.A. VAPOR DENSITY (AIR=1): N.A. EVAPORATION RATE (BUTYL ACETATE): N.A. SOLUBILITY IN WATER: N.A. APPEARANCE AND ODOR: PRISMATIC SHAPE, ODORLESS
CLASSIFICATION: N.A.
STABILITY: UNSTABLE ( ) STABLE (X) CONDITIONS TO AVOID: INCOMPATIBILITY (MATERIALS TO AVOID): HAZARDOUS DECOMPOSITION OR BYPRODUCTS: HAZARDOUS POLYMERIZATION: MAY OCCUR ( ) WILL NOT OCCUR (X) CONDITIONS TO AVOID:
ROUTE(S) OF ENTRY: INHALATION?: N.A. SKIN?: N.A. INGESTION?: N.A. HEALTH HAZARD (ACUTE AND CHRONIC) / TOXICOLOGICAL INFORMATION: IN CASE OF ELECTROLYTE LEAKAGE, SKIN WILL BE ITCHY WHEN CONTAMINATED WITH ELECTROLYTE. IN CONTACT WITH ELECTROLYTE CAN CAUSE SEVERE IRRITATION AND CHEMICAL BURNS. INHALATION OF ELECTROLYTE VAPORS MAY CAUSE IRRITATION OF THE UPPER RESPIRATORY TRACT AND LUNGS.
FIRST AID PROCEDURES: IF ELECTROLYTE LEAKAGE OCCURS AND MAKES CONTACT WITH SKIN, WASH WITH PLENTY OF WATER IMMEDIATELY. IF ELECTROLYTE COMES INTO CONTACT WITH EYES, WASH WITH COPIOUS AMOUNTS OF WATER FOR FIFTEEN (15) MINUTES, AND CONTACT A PHYSICIAN. IF ELECTROLYTE VAPORS ARE INHALED, PROVIDE FRESH AIR AND SEEK MEDICAL ATTENTION IF RESPIRATORY IRRITATION DEVELOPS. VENTILATE THE CONTAMINATED AREA.
FLASH POINT (METHOD USED): N.A. IGNITION TEMP.: N.A. FLAMMABLE LIMITS: N.A. LEL: N.A. UEL: N.A. EXTINGUISHING MEDIA: CARBON DIOXIDE, DRY CHEMICAL OR FOAM EXTINGUISHERS SPECIAL FIRE FIGHTING PROCEDURES: N.A. UNUSUAL FIRE AND EXPLOSION HAZARDS: DO NOT DISPOSE OF BATTERY IN FIRE - MAY EXPLODE. DO NOT SHORT-CIRCUIT BATTERY - MAY CAUSE BURNS.
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: BATTERIES THAT ARE LEAKAGE SHOULD BE HANDLED WITH RUBBER GLOVES. AVOID DIRECT CONTACT WITH ELECTROLYTE. WEAR PROTECTIVE CLOTHING AND A POSITIVE PRESSURE SELF-CONTAINED BREATHING APPARATUS (SCBA).
SAFE HANDLING AND STORAGE ADVICE: BATTERIES SHOULD BE HANDLED AND STORED CAREFULLY TO AVOID SHORT CIRCUITS. DO NOT STORE IN DISORDERLY FASHION, OR ALLOW METAL OBJECTS TO BE MIXED WITH STORED BATTERIES. NEVER DISASSEMBLE A BATTERY. DO NOT BREATHE CELL VAPORS OR TOUCH INTERNAL MATERIAL WITH BARE HANDS. KEEP BATTERIES BETWEEN -30 DEG. C AND 35 DEG. C FOR PROLONG STORAGE.
ENGINEERING CONTROL: NO ENGINEERING MEASURE IS NECESSARY DURING NORMAL USE. IF INTERNAL CELL MATERIALS ARE LEAKED, THE INFORMATION BELOW WILL BE USEFUL. EXPOSURE CONTROL LIMIT: COMMON CHEMICAL NAME / OSHA PEL ACGIH TLV GENERAL NAME MANGANESE COMPOUNDS (CEILING) 5 MG/M3 TWA 0.02 MG/M3 (RESP.) (AS Mn) NICKEL, METAL AND (AS Ni) TWA 1 MG/M3 ELEMENTAL: 1.5 MG/M3 (IHL); INSOLUBLE COMPOUNDS INSOLUBLE INORGANIC COMPOUNDS: 0.2 MG/M3 (IHL) ZINC OXIDE RESPIRABLE FRACTION: RESPIRABLE FRACTION: 5 MG/M3 2 MG/M3 GRAPHITE RESPIRABLE FRACTION: 2 MG/M3 (ALL FORMS EXCEPT 5 MG/M3 FIBERS) CARBON BLACK 3.5 MG/M3 3.5 MG/M3 (IHL) TWA - TIME WEIGHTED AVERAGE ACGIH TLV: AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS THRESHOLD LIMIT VALUE OSHA PEL: OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION PERMISSIBLE EXPOSURE LIMIT
N.A.
DISPOSE OF BATTERIES ACCORDING TO GOVERNMENT REGULATIONS.
GP PRIMARY CARBON ZINC CYLINDRICAL CELLS/BATTERIES ARE CONSIDERED TO BE "DRY CELL" BATTERIES AND ARE UNREGULATED FOR PURPOSES OF TRANSPORTATION BY THE U.S. DEPARTMENT OF TRANSPORTATION (DOT), INTERNATIONAL CIVIC AVIATION ADMINISTRATION (ICAO), INTERNATIONAL AIR TRANSPORT ASSOCIATION (IATA), THE INTERNATIONAL MARITIME ORGANIZATION (IMO). (CARBON ZINC BATTERIES ARE NOT REGULATED FOR TRANSPORTATION AS "DANGEROUS GOODS" UNDER THE IATA DANGEROUS GOODS REGULATIONS 58TH EDITION 2017.) IATA DGR: SPECIAL PROVISION A123: "EXAMPLE OF SUCH BATTERIES ARE: AKALI-MANGANESE, ZINC CARBON. AND NICKEL-CADMIUM BATTERIES. ANY ELECTRICAL BATTERY...HAVING THE POTENTIAL OF A DANGEROUS EVOLUTION OF HEAT MUST BE PREPARED FOR TRANSPORT AS TO PREVENT (A) A SHORT-CIRCUIT (E.G. IN THE CASE OF BATTERIES, BY THE EFFECTIVE INSULATION OF EXPOSED TERMINALS.) IS FORBIDDEN FROM TRANSPORT; AND (B) ACCIDENTAL ACTIVATION. THE WORDS "NOT RESTRICTED" AND THE SPECIAL PROVISION NUMBER MUST BE INCLUDED IN THE DESCRIPTION OF THE SUBSTANCE ON THE AIR WAYBILL AS REQUIRED BY 8.2.6 WHEN AN AIR WAYBILL IS ISSUED. EU: AS PRIMARY CARBON ZINC CELLS/BATTERIES ARE NOT EXPLICITLY MENTIONED IN RID/ADR, THERE ARE NO SPECIAL DANGEROUS GOODS SHIPMENT REQUIREMENTS FOR THESE PRODUCTS. USA: 49 CFR SUBSECTION 172.102 SPECIAL PROVISION 130: "FOR OTHER THAN DRY BATTERY SPECIFICALLY COVERED BY ANOTHER ENTRY IN THE SUBSECTION 172.101 TABLE, "BATTERIES, DRY" ARE NOT SUBJECT TO THE REQUIREMENTS OF THIS SUBCHAPTER WHEN THEY ARE SECURELY PACKAGED AND OFFERED FOR TRANSPORTATION IN A MANNER THAT PREVENTS THE DANGEROUS EVOLUTION OF HEAT (FOR EXAMPLE, BY THE EFFECTIVE INSULATION OF EXPOSED TERMINALS) AND PROTECTS AGAINST SHORT CIRCUITS."
SPECIAL REQUIREMENT BE ACCORDING TO THE LOCAL REGULATORIES.
THE DATA IN THIS MATERIAL SAFETY DATA SHEET RELATES ONLY TO THE SPECIFIC MATERIAL DESIGNATED HEREIN.
IN CASE OF FIRE, IT IS PERMISSIBLE TO USE ANY CLASS OF EXTINGUISHING MEDIUM ON THESE BATTERIES OR THEIR PACKING MATERIAL. COOL EXTERIOR OF BATTERIES IF EXPOSED TO FIRE TO PREVENT RUPTURE. FIRE FIGHTERS SHOULD WEAR SELF-CONTAINED BREATHING APPARATUS. MEMBER GOLD PEAK GROUP |