Common Name: SCOTCHGARD BONNET CLEANER CONCENTRATE (PRODUCT NO. 11, TWIST 'N FILL SYSTEM)
Manufacturer: 3M
SDS Revision Date: 3/19/2014
SDS Format: GHS-US
   
Item Number(s): 5ND37
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1: IDENTIFICATION 
SECTION 2: HAZARD IDENTIFICATION 
SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION 4: FIRST AID MEASURES 
SECTION 5: FIRE-FIGHTING MEASURES 
SECTION 6: ACCIDENTAL RELEASE MEASURES 
SECTION 7: HANDLING AND STORAGE 
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10: STABILITY AND REACTIVITY 
SECTION 11: TOXICOLOGICAL INFORMATION 
SECTION 12: ECOLOGICAL INFORMATION 
SECTION 13: DISPOSAL CONSIDERATIONS 
SECTION 14: TRANSPORT INFORMATION 
SECTION 15: REGULATORY INFORMATION 
SECTION 16: OTHER INFORMATION 



SCOTCHGARD(TM) BONNET CLEANER CONCENTRATE (PRODUCT NO. 11, TWIST
'N FILL(TM) SYSTEM)

03/19/14

3M

SAFETY DATA SHEET

COPYRIGHT, 2014, 3M COMPANY.

ALL RIGHTS RESERVED. COPYING AND/OR DOWNLOADING OF THIS INFORMATION FOR
THE PURPOSE OF PROPERLY UTILIZING 3M PRODUCTS IS ALLOWED PROVIDED THAT:

(1) THE INFORMATION IS COPIED IN FULL WITH NO CHANGES UNLESS PRIOR WRITTEN
AGREEMENT IS OBTAINED FROM 3M, AND

(2) NEITHER THE COPY NOR THE ORIGINAL IS RESOLD OR OTHERWISE DISTRIBUTED
WITH THE INTENTION OF EARNING A PROFIT THEREON.

DOCUMENT GROUP: 19-0058-8

VERSION NUMBER: 7.01

ISSUE DATE: 03/19/14

SUPERCEDES DATE: 02/11/14


SECTION 1: IDENTIFICATION 


1.1. PRODUCT IDENTIFIER:
SCOTCHGARD(TM) BONNET CLEANER CONCENTRATE (PRODUCT NO. 11, TWIST
'N FILL(TM) SYSTEM)

PRODUCT IDENTIFICATION NUMBERS:

ID NUMBER             UPC

70-0712-8511-1        00-48011-25981-4

70-0716-8305-9        00-48011-25981-4

70-0712-8512-9        00-48011-25982-1

70-0716-8306-7        00-48011-25982-1

1.2. RECOMMENDED USE AND RESTRICTIONS ON USE:
RECOMMENDED USE: CARPET CARE, CARPET CLEANER

1.3. SUPPLIER'S DETAILS:

MANUFACTURER: 3M

DIVISION: COMMERCIAL SOLUTIONS DIVISION

ADDRESS:
3M CENTER
ST. PAUL, MN 55144-1000
USA

TELEPHONE: 1-888-3M HELPS (1-888-364-3577)

1.4. EMERGENCY TELEPHONE NUMBER:
1-800-364-3577 OR (651) 737-6501 (24 HOURS)


SECTION 2: HAZARD IDENTIFICATION 


2.1. HAZARD CLASSIFICATION:
SKIN SENSITIZER: CATEGORY 1.

2.2. LABEL ELEMENTS:

SIGNAL WORD: WARNING

SYMBOLS: EXCLAMATION MARK

PICTOGRAMS: EXCLAMATION MARK

HAZARD STATEMENTS:
MAY CAUSE AN ALLERGIC SKIN REACTION.

PRECAUTIONARY STATEMENTS:

PREVENTION:
AVOID BREATHING DUST/FUME/GAS/MIST/VAPORS/SPRAY.
WEAR PROTECTIVE GLOVES.
CONTAMINATED WORK CLOTHING MUST NOT BE ALLOWED OUT OF THE WORKPLACE.

RESPONSE:
IF ON SKIN: WASH WITH PLENTY OF SOAP AND WATER.

IF SKIN IRRITATION OR RASH OCCURS:
GET MEDICAL ADVICE/ATTENTION.
WASH CONTAMINATED CLOTHING BEFORE REUSE.

DISPOSAL:
DISPOSE OF CONTENTS/CONTAINER IN ACCORDANCE WITH APPLICABLE
LOCAL/REGIONAL/NATIONAL/INTERNATIONAL REGULATIONS.

NOTES TO PHYSICIAN: NOT APPLICABLE

2.3. HAZARDS NOT OTHERWISE CLASSIFIED: NONE.

1% OF THE MIXTURE CONSISTS OF INGREDIENTS OF UNKNOWN ACUTE ORAL TOXICITY.


SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 


INGREDIENT                          C.A.S. NO.     % BY WT

WATER                                7732-18-5      80 - 100 TRADE SECRET *

1-PROPOXY-2-PROPANOL                 1569-01-3       3 - 7 TRADE SECRET *

POLYMER (NJTSRN 04499600-6944)      TRADE SECRET*    1 - 5 TRADE SECRET *

BENZENESULFONIC ACID, DODECYL-,     69227-09-4     0.5 - 1.5 TRADE SECRET *
BRANCHED, SODIUM SALT

SODIUM MONO-C10-16-ALKYL SULFATES   68585-47-7     0.5 - 1.5 TRADE SECRET *

D-LIMONENE                           5989-27-5     <0.5 TRADE SECRET *

NJTS OR NJTSRN: NEW JERSEY TRADE SECRET REGISTRY NUMBER.

*THE SPECIFIC CHEMICAL IDENTITY AND/OR EXACT PERCENTAGE (CONCENTRATION) OF
THIS COMPOSITION HAS BEEN WITHHELD AS A TRADE SECRET.


SECTION 4: FIRST AID MEASURES 


4.1. DESCRIPTION OF FIRST AID MEASURES:

INHALATION:
REMOVE PERSON TO FRESH AIR. IF YOU FEEL UNWELL, GET MEDICAL ATTENTION.

SKIN CONTACT:
IMMEDIATELY WASH WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND
WASH BEFORE REUSE. IF SIGNS/SYMPTOMS DEVELOP, GET MEDICAL ATTENTION.

EYE CONTACT:
FLUSH WITH LARGE AMOUNTS OF WATER. REMOVE CONTACT LENSES IF EASY TO DO.
CONTINUE RINSING. IF SIGNS/SYMPTOMS PERSIST, GET MEDICAL ATTENTION.

IF SWALLOWED: RINSE MOUTH. IF YOU FEEL UNWELL, GET MEDICAL ATTENTION.

4.2. MOST IMPORTANT SYMPTOMS AND EFFECTS, BOTH ACUTE AND DELAYED:
SEE SECTION 11.1. INFORMATION ON TOXICOLOGICAL EFFECTS.

4.3. INDICATION OF ANY IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT
REQUIRED: NOT APPLICABLE


SECTION 5: FIRE-FIGHTING MEASURES 


5.1. SUITABLE EXTINGUISHING MEDIA:

IN CASE OF FIRE:
USE A FIRE FIGHTING AGENT SUITABLE FOR ORDINARY COMBUSTIBLE MATERIAL
SUCH AS WATER OR FOAM TO EXTINGUISH.

5.2. SPECIAL HAZARDS ARISING FROM THE SUBSTANCE OR MIXTURE:
NONE INHERENT IN THIS PRODUCT.

HAZARDOUS DECOMPOSITION OR BY-PRODUCTS:

SUBSTANCE                  CONDITION

CARBON MONOXIDE            DURING COMBUSTION

CARBON DIOXIDE             DURING COMBUSTION

OXIDES OF SULFUR           DURING COMBUSTION

5.3. SPECIAL PROTECTIVE ACTIONS FOR FIRE-FIGHTERS:
NO UNUSUAL FIRE OR EXPLOSION HAZARDS ARE ANTICIPATED.


SECTION 6: ACCIDENTAL RELEASE MEASURES 


6.1. PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:
VENTILATE THE AREA WITH FRESH AIR. FOR LARGE SPILL, OR SPILLS IN CONFINED
SPACES, PROVIDE MECHANICAL VENTILATION TO DISPERSE OR EXHAUST VAPORS, IN
ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE PRACTICE.

WARNING!

A MOTOR COULD BE AN IGNITION SOURCE AND COULD CAUSE FLAMMABLE GASES OR
VAPORS IN THE SPILL AREA TO BURN OR EXPLODE. REFER TO OTHER SECTIONS OF
THIS SDS FOR INFORMATION REGARDING PHYSICAL AND HEALTH HAZARDS, RESPIRATORY
PROTECTION, VENTILATION, AND PERSONAL PROTECTIVE EQUIPMENT.

6.2. ENVIRONMENTAL PRECAUTIONS:
AVOID RELEASE TO THE ENVIRONMENT.

6.3. METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP:
CONTAIN SPILL. WORKING FROM AROUND THE EDGES OF THE SPILL INWARD, COVER
WITH BENTONITE, VERMICULITE, OR COMMERCIALLY AVAILABLE INORGANIC ABSORBENT
MATERIAL. MIX IN SUFFICIENT ABSORBENT UNTIL IT APPEARS DRY. REMEMBER,
ADDING AN ABSORBENT MATERIAL DOES NOT REMOVE A PHYSICAL, HEALTH, OR
ENVIRONMENTAL HAZARD. COLLECT AS MUCH OF THE SPILLED MATERIAL AS POSSIBLE.
PLACE IN A CLOSED CONTAINER APPROVED FOR TRANSPORTATION BY APPROPRIATE
AUTHORITIES. CLEAN UP RESIDUE WITH WATER. SEAL THE CONTAINER. DISPOSE OF
COLLECTED MATERIAL AS SOON AS POSSIBLE.


SECTION 7: HANDLING AND STORAGE 


7.1. PRECAUTIONS FOR SAFE HANDLING:
FOR INDUSTRIAL OR PROFESSIONAL USE ONLY. THIS PRODUCT IS NOT INTENDED TO
BE USED WITHOUT PRIOR DILUTION AS SPECIFIED ON THE PRODUCT LABEL. GROUNDING
OR SAFETY SHOES WITH ELECTROSTATIC DISSIPATING SOLES (ESD) ARE NOT REQUIRED
WITH A CHEMICAL DISPENSING SYSTEM. AVOID BREATHING DUST/FUME/GAS/MIST/
VAPORS/SPRAY. DO NOT GET IN EYES, ON SKIN, OR ON CLOTHING. DO NOT EAT,
DRINK OR SMOKE WHEN USING THIS PRODUCT. WASH THOROUGHLY AFTER HANDLING.
CONTAMINATED WORK CLOTHING SHOULD NOT BE ALLOWED OUT OF THE WORKPLACE.
WASH CONTAMINATED CLOTHING BEFORE REUSE. AVOID CONTACT WITH OXIDIZING
AGENTS (EG. CHLORINE, CHROMIC ACID ETC.)

7.2. CONDITIONS FOR SAFE STORAGE INCLUDING ANY INCOMPATIBILITIES:
STORE AWAY FROM OXIDIZING AGENTS.


SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 


8.1. CONTROL PARAMETERS:

OCCUPATIONAL EXPOSURE LIMITS:
NO OCCUPATIONAL EXPOSURE LIMIT VALUES EXIST FOR ANY OF THE COMPONENTS
LISTED IN SECTION 3 OF THIS SDS.

8.2. EXPOSURE CONTROLS:

8.2.1. ENGINEERING CONTROLS:

NOTE:
WHEN USED WITH A CHEMICAL DISPENSING SYSTEM AS DIRECTED, SPECIAL
VENTILATION IS NOT REQUIRED.

IF PRODUCT IS NOT USED WITH A CHEMICAL DISPENSING SYSTEM OR IF THERE IS AN
ACCIDENTAL RELEASE:
USE GENERAL DILUTION VENTILATION AND/OR LOCAL EXHAUST VENTILATION TO
CONTROL AIRBORNE EXPOSURES TO BELOW RELEVANT EXPOSURE LIMITS AND/OR
CONTROL DUST/FUME/GAS/MIST/VAPORS/SPRAY. IF VENTILATION IS NOT ADEQUATE,
USE RESPIRATORY PROTECTION EQUIPMENT.

8.2.2. PERSONAL PROTECTIVE EQUIPMENT (PPE):

EYE/FACE PROTECTION:

NOTE:
WHEN USED WITH A CHEMICAL DISPENSING SYSTEM AS DIRECTED, EYE CONTACT WITH
THE CONCENTRATE IS NOT EXPECTED TO OCCUR. IF THE PRODUCT IS NOT USED WITH
A CHEMICAL DISPENSING SYSTEM OR IF THERE IS AN ACCIDENTAL RELEASE, WEAR
PROTECTIVE EYE/FACE PROTECTION. SELECT AND USE EYE/FACE PROTECTION TO
PREVENT CONTACT BASED ON THE RESULTS OF AN EXPOSURE ASSESSMENT.

THE FOLLOWING EYE/FACE PROTECTION(S) ARE RECOMMENDED:
SAFETY GLASSES WITH SIDE SHIELDS

SKIN/HAND PROTECTION:

NOTE:
WHEN USED WITH A CHEMICAL DISPENSING SYSTEM AS DIRECTED, SKIN CONTACT WITH
THE CONCENTRATE IS NOT EXPECTED TO OCCUR.

IF PRODUCT IS NOT USED WITH A CHEMICAL DISPENSING SYSTEM OR IF THERE IS AN
ACCIDENTAL RELEASE:
SELECT AND USE GLOVES AND/OR PROTECTIVE CLOTHING APPROVED TO RELEVANT
LOCAL STANDARDS TO PREVENT SKIN CONTACT BASED ON THE RESULTS OF AN
EXPOSURE ASSESSMENT. SELECTION SHOULD BE BASED ON USE FACTORS SUCH AS
EXPOSURE LEVELS, CONCENTRATION OF THE SUBSTANCE OR MIXTURE, FREQUENCY
AND DURATION, PHYSICAL CHALLENGES SUCH AS TEMPERATURE EXTREMES, AND
OTHER USE CONDITIONS. CONSULT WITH YOUR GLOVE AND/OR PROTECTIVE CLOTHING
MANUFACTURER FOR SELECTION OF APPROPRIATE COMPATIBLE GLOVES/PROTECTIVE
CLOTHING.

GLOVES MADE FROM THE FOLLOWING MATERIAL(S) ARE RECOMMENDED:
FLUOROELASTOMER
NITRILE RUBBER
POLYVINYL ALCOHOL (PVA)
POLYMER LAMINATE

IF THIS PRODUCT IS USED IN A MANNER THAT PRESENTS A HIGHER POTENTIAL FOR
EXPOSURE (EG. SPRAYING, HIGH SPLASH POTENTIAL ETC.), THEN USE OF
PROTECTIVE COVERALLS MAY BE NECESSARY. SELECT AND USE BODY PROTECTION
TO PREVENT CONTACT BASED ON THE RESULTS OF AN EXPOSURE ASSESSMENT.

THE FOLLOWING PROTECTIVE CLOTHING MATERIAL(S) ARE RECOMMENDED:
APRON - POLYMER LAMINATE

RESPIRATORY PROTECTION:

NOTE:
WHEN USED WITH A CHEMICAL DISPENSING SYSTEM AS DIRECTED, RESPIRATORY
PROTECTION IS NOT REQUIRED.

IF PRODUCT IS NOT USED WITH A CHEMICAL DISPENSING SYSTEM OR IF THERE IS AN
ACCIDENTAL RELEASE:
AN EXPOSURE ASSESSMENT MAY BE NEEDED TO DECIDE IF A RESPIRATOR IS REQUIRED.
IF A RESPIRATOR IS NEEDED, USE RESPIRATORS AS PART OF A FULL RESPIRATORY
PROTECTION PROGRAM.

BASED ON THE RESULTS OF THE EXPOSURE ASSESSMENT, SELECT FROM THE FOLLOWING
RESPIRATOR TYPE(S) TO REDUCE INHALATION EXPOSURE:
HALF FACEPIECE OR FULL FACEPIECE AIR-PURIFYING RESPIRATOR SUITABLE FOR
ORGANIC VAPORS

FOR QUESTIONS ABOUT SUITABILITY FOR A SPECIFIC APPLICATION, CONSULT WITH
YOUR RESPIRATOR MANUFACTURER.


SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 


9.1. INFORMATION ON BASIC PHYSICAL AND CHEMICAL PROPERTIES:

GENERAL PHYSICAL FORM: LIQUID

SPECIFIC PHYSICAL FORM: LIQUID

ODOR, COLOR, GRADE: CLEAR SLIGHTLY YELLOW. PLEASANT FRAGRANCE.

ODOR THRESHOLD: NO DATA AVAILABLE

PH: 7.7 - 9.7

MELTING POINT: NOT APPLICABLE

BOILING POINT: APPROXIMATELY 212 DEG. F

FLASH POINT: APPROXIMATELY >200 DEG. F [TEST METHOD: CLOSED CUP]

EVAPORATION RATE: APPROXIMATELY 1 [REF STD: WATER=1]

FLAMMABILITY (SOLID, GAS): NOT APPLICABLE

FLAMMABLE LIMITS (LEL): NO DATA AVAILABLE
FLAMMABLE LIMITS (UEL): NO DATA AVAILABLE

VAPOR PRESSURE: <=27 PSIA [@ 131 DEG. F]

VAPOR DENSITY: NO DATA AVAILABLE

DENSITY: 1.01 G/CM3 [REF STD: WATER=1]

SPECIFIC GRAVITY: APPROXIMATELY 1.01 [@ 72 DEG. F] [REF STD: WATER=1]

SOLUBILITY IN WATER: NO DATA AVAILABLE

SOLUBILITY- NON-WATER: NO DATA AVAILABLE

PARTITION COEFFICIENT N-OCTANOL/WATER: NO DATA AVAILABLE

AUTOIGNITION TEMPERATURE: NO DATA AVAILABLE

DECOMPOSITION TEMPERATURE: NO DATA AVAILABLE

VISCOSITY: 14.2 - 15.6 SEC [@ 72 DEG. C ]

AVERAGE PARTICLE SIZE: NOT APPLICABLE

HAZARDOUS AIR POLLUTANTS: NO DATA AVAILABLE

VOLATILE ORGANIC COMPOUNDS:
3 - 7 % [TEST METHOD: CALCULATED PER CARB TITLE 2]

PERCENT VOLATILE: NO DATA AVAILABLE

VOC LESS H2O & EXEMPT SOLVENTS:
<900 G/L [TEST METHOD: CALCULATED PER CARB TITLE 2]


SECTION 10: STABILITY AND REACTIVITY 


10.1. REACTIVITY:
THIS MATERIAL MAY BE REACTIVE WITH CERTAIN AGENTS UNDER CERTAIN
CONDITIONS - SEE THE REMAINING HEADINGS IN THIS SECTION.

10.2. CHEMICAL STABILITY: STABLE.

10.3. POSSIBILITY OF HAZARDOUS REACTIONS:
HAZARDOUS POLYMERIZATION WILL NOT OCCUR.

10.4. CONDITIONS TO AVOID: NOT DETERMINED

10.5. INCOMPATIBLE MATERIALS: STRONG OXIDIZING AGENTS

10.6. HAZARDOUS DECOMPOSITION PRODUCTS:

SUBSTANCE                   CONDITION

NONE KNOWN.

REFER TO SECTION 5.2 FOR HAZARDOUS DECOMPOSITION PRODUCTS DURING
COMBUSTION.


SECTION 11: TOXICOLOGICAL INFORMATION 


THE INFORMATION BELOW MAY NOT BE CONSISTENT WITH THE MATERIAL
CLASSIFICATION IN SECTION 2 IF SPECIFIC INGREDIENT CLASSIFICATIONS ARE
MANDATED BY A COMPETENT AUTHORITY. IN ADDITION, TOXICOLOGICAL DATA ON
INGREDIENTS MAY NOT BE REFLECTED IN THE MATERIAL CLASSIFICATION AND/OR
THE SIGNS AND SYMPTOMS OF EXPOSURE, BECAUSE AN INGREDIENT MAY BE PRESENT
BELOW THE THRESHOLD FOR LABELING, AN INGREDIENT MAY NOT BE AVAILABLE FOR
EXPOSURE, OR THE DATA MAY NOT BE RELEVANT TO THE MATERIAL AS A WHOLE.

11.1. INFORMATION ON TOXICOLOGICAL EFFECTS:

SIGNS AND SYMPTOMS OF EXPOSURE:
BASED ON TEST DATA AND/OR INFORMATION ON THE COMPONENTS, THIS MATERIAL
MAY PRODUCE THE FOLLOWING HEALTH EFFECTS:

INHALATION:

RESPIRATORY TRACT IRRITATION:
SIGNS/SYMPTOMS MAY INCLUDE COUGH, SNEEZING, NASAL DISCHARGE, HEADACHE,
HOARSENESS, AND NOSE AND THROAT PAIN.

SKIN CONTACT:
CONTACT WITH THE SKIN DURING PRODUCT USE IS NOT EXPECTED TO RESULT IN
SIGNIFICANT IRRITATION. ALLERGIC SKIN REACTION (NON-PHOTO INDUCED):
SIGNS/SYMPTOMS MAY INCLUDE REDNESS, SWELLING, BLISTERING, AND ITCHING.

EYE CONTACT:
CONTACT WITH THE EYES DURING PRODUCT USE IS NOT EXPECTED TO RESULT IN
SIGNIFICANT IRRITATION.

INGESTION: NO HEALTH EFFECTS ARE EXPECTED.

TOXICOLOGICAL DATA:
IF A COMPONENT IS DISCLOSED IN SECTION 3 BUT DOES NOT APPEAR IN A TABLE
BELOW, EITHER NO DATA ARE AVAILABLE FOR THAT ENDPOINT OR THE DATA ARE NOT
SUFFICIENT FOR CLASSIFICATION.

ACUTE TOXICITY:

NAME                  ROUTE         SPECIES   VALUE

OVERALL PRODUCT       INGESTION               NO DATA AVAILABLE
                                              CALCULATED ATE:
                                              >5,000 MG/KG

1-PROPOXY-2-PROPANOL  DERMAL        RABBIT    LD50; 2,805 MG/KG

1-PROPOXY-2-PROPANOL  INHALATION-   RAT       LC50: >11.8 MG/L
                      DUST/MIST
                      (4 HOURS)

1-PROPOXY-2-PROPANOL  INGESTION     RAT       LD50: 2,500 MG/KG

POLYMER (NJTSRN       INGESTION               LD50:
04499600-6944)                                ESTIMATED TO BE
                                              2,000 - 5,000 MG/KG

SODIUM MONO-C10-16-   INGESTION     RAT       LD50: >2,000 MG/KG
ALKYL SULFATES

D-LIMONENE            DERMAL        RABBIT    LD50: >5,000 MG/KG

D-LIMONENE            INGESTION     RAT       LD50: 4,400 MG/KG

ATE = ACUTE TOXICITY ESTIMATE

SKIN CORROSION/IRRITATION:

NAME                      SPECIES      VALUE

1-PROPOXY-2-PROPANOL      RABBIT       MINIMAL IRRITATION

D-LIMONENE                RABBIT       MILD IRRITANT

SERIOUS EYE DAMAGE/IRRITATION:

NAME                      SPECIES       VALUE

1-PROPOXY-2-PROPANOL      RABBIT        SEVERE IRRITANT

D-LIMONENE                RABBIT        MILD IRRITANT

SKIN SENSITIZATION:

NAME                      SPECIES       VALUE

D-LIMONENE                MOUSE         SENSITIZING

RESPIRATORY SENSITIZATION:

NAME                      SPECIES       VALUE

GERM CELL MUTAGENICITY:

NAME                     ROUTE         VALUE

1-PROPOXY-2-PROPANOL     IN VITRO      NOT MUTAGENIC

D-LIMONENE               IN VITRO      NOT MUTAGENIC

D-LIMONENE               IN VIVO       NOT MUTAGENIC

CARCINOGENICITY:

NAME           ROUTE       SPECIES    VALUE

D-LIMONENE     INGESTION   RAT        SOME POSITIVE DATA EXIST,
                                      BUT THE DATA ARE NOT
                                      SUFFICIENT FOR CLASSIFICATION

REPRODUCTIVE TOXICITY:

REPRODUCTIVE AND/OR DEVELOPMENTAL EFFECTS:

NAME                    ROUTE        VALUE

1-PROPOXY-2-PROPANOL   INHALATION    SOME POSITIVE DEVELOPMENTAL DATA
                                     EXIST, BUT THE DATA ARE NOT
                                     SUFFICIENT FOR CLASSIFICATION

D-LIMONENE             INGESTION     NOT TOXIC TO MALE REPRODUCTION

D-LIMONENE             INGESTION     SOME POSITIVE FEMALE REPRODUCTIVE
                                     DATA EXIST, BUT THE DATA ARE NOT
                                     SUFFICIENT FOR CLASSIFICATION

D-LIMONENE             INGESTION     SOME POSITIVE DEVELOPMENTAL DATA
                                     EXIST, BUT THE DATA ARE NOT
                                     SUFFICIENT FOR CLASSIFICATION


NAME                  SPECIES    TEST RESULT           EXPOSURE DURATION

1-PROPOXY-2-PROPANOL  RAT        NOAEL: 3.6 MG/L       DURING ORGANOGENESIS

D-LIMONENE            RAT        NOAEL: 150 MG/KG/DAY  103 WEEKS

D-LIMONENE            RAT        NOAEL: 750 MG/KG/DAY  PREMATING & DURING
                                                       GESTATION

D-LIMONENE            MULTIPLE   NOAEL: 591 MG/KG/DAY  DURING ORGANOGENESIS
                      ANIMAL
                      SPECIES

TARGET ORGAN(S):

SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE:

NAME           ROUTE        TARGET ORGAN(S)     VALUE

1-PROPOXY-2-   INHALATION   CENTRAL NERVOUS     MAY CAUSE DROWSINESS OR
PROPANOL                    SYSTEM DEPRESSION   DIZZINESS

1-PROPOXY-2-   INHALATION   RESPIRATORY         SOME POSITIVE DATA EXIST,
PROPANOL                    IRRITATION          BUT THE DATA ARE NOT
                                                SUFFICIENT FOR
                                                CLASSIFICATION

1-PROPOXY-2-   INGESTION    CENTRAL NERVOUS     MAY CAUSE DROWSINESS OR
PROPANOL                                        SYSTEM DEPRESSION
                                                DIZZINESS

D-LIMONENE     INGESTION    NERVOUS SYSTEM      SOME POSITIVE DATA EXIST,
                                                BUT THE DATA ARE NOT
                                                SUFFICIENT FOR
                                                CLASSIFICATION


NAME           SPECIES     TEST RESULT              EXPOSURE DURATION

1-PROPOXY-2-   MULTIPLE    LOAEL: 10.8 MG/L         6 HOURS
               ANIMAL
               SPECIES

1-PROPOXY-2-               NOAEL: NOT AVAILABLE
PROPANOL

1-PROPOXY-2-   RAT         LOAEL: 1,770 MG/KG       NOT APPLICABLE
PROPANOL

D-LIMONENE                 NOAEL: NOT AVAILABLE

SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE:

NAME          ROUTE        TARGET ORGAN(S)   VALUE

1-PROPOXY-2-  INHALATION   LIVER             SOME POSITIVE DATA EXIST, BUT
PROPANOL                   KIDNEY            THE DATA ARE NOT SUFFICIENT
                           AND/OR            FOR CLASSIFICATION
                           BLADDER

D-LIMONENE    INGESTION    KIDNEY AND/OR     SOME POSITIVE DATA EXIST, BUT
                           BLADDER           THE DATA ARE NOT SUFFICIENT
                                             FOR CLASSIFICATION

D-LIMONENE    INGESTION    LIVER             SOME POSITIVE DATA EXIST, BUT
                                             THE DATA ARE NOT SUFFICIENT
                                             FOR CLASSIFICATION

D-LIMONENE    INGESTION    HEART             ALL DATA ARE NEGATIVE
                           ENDOCRINE
                           SYSTEM
                           BONE, TEETH,
                           NAILS, AND/OR
                           HAIR
                           HEMATOPOIETIC
                           SYSTEM
                           IMMUNE SYSTEM
                           MUSCLES
                           NERVOUS SYSTEM
                           RESPIRATORY
                           SYSTEM


NAME                   SPECIES   TEST RESULT              EXPOSURE DURATION

1-PROPOXY-2-PROPANOL   RAT       NOAEL: 9.5 MG/L          11 DAYS

D-LIMONENE             RAT       LOAEL: 75 MG/KG/DAY      103 WEEKS

D-LIMONENE             MOUSE     NOAEL: 1,000 MG/KG/DAY   103 WEEKS

D-LIMONENE             RAT       NOAEL: 600 MG/KG/DAY     103 WEEKS

ASPIRATION HAZARD:

NAME                 VALUE

D-LIMONENE           ASPIRATION HAZARD

PLEASE CONTACT THE ADDRESS OR PHONE NUMBER LISTED IN SECTION 1 OF THIS
SDS FOR ADDITIONAL TOXICOLOGICAL INFORMATION ON THIS MATERIAL AND/OR
ITS COMPONENTS.


SECTION 12: ECOLOGICAL INFORMATION 


ECOTOXICOLOGICAL INFORMATION:
A 3M PRODUCT ENVIRONMENTAL DATA SHEET (PED) IS AVAILABLE.

CHEMICAL FATE INFORMATION:
A 3M PRODUCT ENVIRONMENTAL DATA SHEET (PED) IS AVAILABLE.


SECTION 13: DISPOSAL CONSIDERATIONS 


13.1. DISPOSAL METHODS:
DISPOSE OF CONTENTS/ CONTAINER IN ACCORDANCE WITH THE LOCAL/REGIONAL/
NATIONAL/INTERNATIONAL REGULATIONS. DISPOSE OF WASTE PRODUCT IN A
PERMITTED INDUSTRIAL WASTE FACILITY. EMPTY DRUMS/BARRELS/CONTAINERS USED
FOR TRANSPORTING AND HANDLING HAZARDOUS CHEMICALS (CHEMICAL
SUBSTANCES/MIXTURES/PREPARATIONS CLASSIFIED AS HAZARDOUS AS PER APPLICABLE
REGULATIONS) SHALL BE CONSIDERED, STORED, TREATED & DISPOSED OF AS
HAZARDOUS WASTES UNLESS OTHERWISE DEFINED BY APPLICABLE WASTE REGULATIONS.
CONSULT WITH THE RESPECTIVE REGULATING AUTHORITIES TO DETERMINE THE
AVAILABLE TREATMENT AND DISPOSAL FACILITIES.

EPA HAZARDOUS WASTE NUMBER (RCRA): NOT REGULATED


SECTION 14: TRANSPORT INFORMATION 


FOR TRANSPORT INFORMATION, PLEASE VISIT:
HTTP://3M.COM/TRANSPORTINFO OR CALL 1-800-364-3577 OR 651-737-6501.


SECTION 15: REGULATORY INFORMATION 


15.1. US FEDERAL REGULATIONS:

311/312 HAZARD CATEGORIES:
FIRE HAZARD: NO
PRESSURE HAZARD: NO
REACTIVITY HAZARD: NO
IMMEDIATE HAZARD: YES
DELAYED HAZARD: NO

15.2. STATE REGULATIONS:

15.3. CHEMICAL INVENTORIES:
THE COMPONENTS OF THIS PRODUCT ARE IN COMPLIANCE WITH THE NEW SUBSTANCE
NOTIFICATION REQUIREMENTS OF CEPA.

THE COMPONENTS OF THIS MATERIAL ARE IN COMPLIANCE WITH THE CHINA "MEASURES
ON ENVIRONMENTAL MANAGEMENT OF NEW CHEMICAL SUBSTANCE". CERTAIN
RESTRICTIONS MAY APPLY. CONTACT THE SELLING DIVISION FOR ADDITIONAL
INFORMATION.

THE COMPONENTS OF THIS MATERIAL ARE IN COMPLIANCE WITH THE PROVISIONS OF
THE KOREAN TOXIC CHEMICAL CONTROL LAW. CERTAIN RESTRICTIONS MAY APPLY.
CONTACT THE SELLING DIVISION FOR ADDITIONAL INFORMATION.

THE COMPONENTS OF THIS PRODUCT ARE IN COMPLIANCE WITH THE CHEMICAL
NOTIFICATION REQUIREMENTS OF TSCA.

THIS PRODUCT COMPLIES WITH THE NEW ZEALAND HAZARDOUS SUBSTANCES AND NEW
ORGANISMS ACT (1996).

15.4. INTERNATIONAL REGULATIONS:
THIS SDS HAS BEEN PREPARED TO MEET THE U.S. OSHA HAZARD COMMUNICATION
STANDARD, 29 CFR 1910.1200.


SECTION 16: OTHER INFORMATION 


NFPA HAZARD CLASSIFICATION:
HEALTH          2
FLAMMABILITY    1
INSTABILITY     0
SPECIAL HAZARDS NONE

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) HAZARD RATINGS ARE DESIGNED
FOR USE BY EMERGENCY RESPONSE PERSONNEL TO ADDRESS THE HAZARDS THAT ARE
PRESENTED BY SHORT-TERM, ACUTE EXPOSURE TO A MATERIAL UNDER CONDITIONS OF
FIRE, SPILL, OR SIMILAR EMERGENCIES. HAZARD RATINGS ARE PRIMARILY BASED
ON THE INHERENT PHYSICAL AND TOXIC PROPERTIES OF THE MATERIAL BUT ALSO
INCLUDE THE TOXIC PROPERTIES OF COMBUSTION OR DECOMPOSITION PRODUCTS THAT
ARE KNOWN TO BE GENERATED IN SIGNIFICANT QUANTITIES.

HMIS HAZARD CLASSIFICATION:
HEALTH              2
FLAMMABILITY        1
PHYSICAL HAZARD     0
PERSONAL PROTECTION X - SEE PPE SECTION.

HAZARDOUS MATERIAL IDENTIFICATION SYSTEM (HMIS(R*) III) HAZARD RATINGS
ARE DESIGNED TO INFORM EMPLOYEES OF CHEMICAL HAZARDS IN THE WORKPLACE.
THESE RATINGS ARE BASED ON THE INHERENT PROPERTIES OF THE MATERIAL UNDER
EXPECTED CONDITIONS OF NORMAL USE AND ARE NOT INTENDED FOR USE IN
EMERGENCY SITUATIONS. HMIS(R*) III RATINGS ARE TO BE USED WITH A FULLY
IMPLEMENTED HMIS(R*) III PROGRAM. HMIS(R*)IS A REGISTERED MARK OF THE
AMERICAN COATINGS ASSOCIATION (ACA).

DOCUMENT GROUP: 19-0058-8

VERSION NUMBER: 7.01

ISSUE DATE: 03/19/14

SUPERCEDES DATE: 02/11/14

DISCLAIMER:
THE INFORMATION IN THIS SAFETY DATA SHEET (SDS) IS BELIEVED TO BE CORRECT
AS OF THE DATE ISSUED. 3M MAKES NO WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE OR COURSE OF PERFORMANCE OR USAGE OF
TRADE. USER IS RESPONSIBLE FOR DETERMINING WHETHER THE 3M PRODUCT IS FIT
FOR A PARTICULAR PURPOSE AND SUITABLE FOR USER'S METHOD OF USE OR
APPLICATION. GIVEN THE VARIETY OF FACTORS THAT CAN AFFECT THE USE AND
APPLICATION OF A 3M PRODUCT, SOME OF WHICH ARE UNIQUELY WITHIN THE USER'S
KNOWLEDGE AND CONTROL, IT IS ESSENTIAL THAT THE USER EVALUATE THE 3M
PRODUCT TO DETERMINE WHETHER IT IS FIT FOR A PARTICULAR PURPOSE AND
SUITABLE FOR USER'S METHOD OF USE OR APPLICATION.

3M PROVIDES INFORMATION IN ELECTRONIC FORM AS A SERVICE TO ITS CUSTOMERS.
DUE TO THE REMOTE POSSIBILITY THAT ELECTRONIC TRANSFER MAY HAVE RESULTED
IN ERRORS, OMISSIONS OR ALTERATIONS IN THIS INFORMATION, 3M MAKES NO
REPRESENTATIONS AS TO ITS COMPLETENESS OR ACCURACY. IN ADDITION,
INFORMATION OBTAINED FROM A DATABASE MAY NOT BE AS CURRENT AS THE
INFORMATION IN THE SDS AVAILABLE DIRECTLY FROM 3M

3M USA SDSS ARE AVAILABLE AT WWW.3M.COM