SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. HENKEL SAFETY DATA SHEET REVISION NUMBER: 009.1 ISSUE DATE: 05/19/2022
PRODUCT NAME: LOCTITE SI 5920 RTV SILICONE COPPER KNOWN AS LOCTITE CO RTV SIL 70ML EN PRODUCT TYPE/USE: SILICONE RESTRICTION OF USE: NONE IDENTIFIED IDH NUMBER: 198818 ITEM NUMBER: 30542 REGION: UNITED STATES COMPANY ADDRESS: HENKEL CORPORATION ONE HENKEL WAY ROCKY HILL, CONNECTICUT 06067 CONTACT INFORMATION: TELEPHONE: +1 (860) 571-5100 MEDICAL EMERGENCY PHONE: POISON CONTROL CENTER 1-877-671-4608 (TOLL FREE) OR 1-303-592-1711 TRANSPORT EMERGENCY PHONE: CHEMTREC: 1-800-424-9300 (TOLL FREE) OR 1-703-527-3887 INTERNET: WWW.HENKELNA.COM
EMERGENCY OVERVIEW: WARNING MAY CAUSE AN ALLERGIC SKIN REACTION. CAUSES SERIOUS EYE IRRITATION. SUSPECTED OF CAUSING CANCER. MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE. HAZARD CLASS HAZARD CATEGORY EYE IRRITATION 2A SKIN SENSITIZATION 1 CARCINOGENICITY 2 SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE 2 PICTOGRAM(S): HEALTH HAZARD EXCLAMATION MARK PRECAUTIONARY STATEMENTS: PREVENTION: OBTAIN SPECIAL INSTRUCTIONS BEFORE USE. DO NOT HANDLE UNTIL ALL SAFETY PRECAUTIONS HAVE BEEN READ AND UNDERSTOOD. DO NOT BREATHE DUST OR FUMES. WASH AFFECTED AREA THOROUGHLY AFTER HANDLING. CONTAMINATED WORK CLOTHING SHOULD NOT BE ALLOWED OUT OF THE WORKPLACE. WEAR PROTECTIVE GLOVES, CLOTHING, EYE AND FACE PROTECTION. RESPONSE: IF ON SKIN: WASH WITH PLENTY OF WATER. IF IN EYES: RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES. REMOVE CONTACT LENSES, IF PRESENT AND EASY TO DO. CONTINUE RINSING. IF EXPOSED OR CONCERNED: GET MEDICAL ATTENTION. IF SKIN IRRITATION OR RASH OCCURS: GET MEDICAL ATTENTION. IF EYE IRRITATION PERSISTS: GET MEDICAL ATTENTION. WASH CONTAMINATED CLOTHING BEFORE REUSE. STORAGE: STORE LOCKED UP. DISPOSAL: DISPOSE OF CONTENTS AND/OR CONTAINER ACCORDING TO FEDERAL, STATE/PROVINCIAL AND LOCAL GOVERNMENTAL REGULATIONS. CLASSIFICATION COMPLIES WITH OSHA HAZARD COMMUNICATION STANDARD (29 CFR 1910.1200) AND IS CONSISTENT WITH THE PROVISIONS OF THE UNITED NATIONS GLOBALLY HARMONIZED SYSTEM OF CLASSIFICATION AND LABELING OF CHEMICALS (GHS). SEE SECTION 11 FOR ADDITIONAL TOXICOLOGICAL INFORMATION.
HAZARDOUS COMPONENT(S) CAS NUMBER PERCENTAGE* SILANE, DICHLORODIMETHYL-, REACTION 68611-44-9 5 - 10 PRODUCTS WITH SILICA BUTAN-2-ONE O,O',O''- 2224-33-1 1 - 5 (VINYLSILYLIDYNE)TRIOXIME DIIRON TRIOXIDE 1309-37-1 1 - 5 MICA 12001-26-2 1 - 5 2-BUTANONE OXIME 96-29-7 1 - 5 * EXACT PERCENTAGES MAY VARY OR ARE TRADE SECRET. CONCENTRATION RANGE IS PROVIDED TO ASSIST USERS IN PROVIDING APPROPRIATE PROTECTIONS.
INHALATION: MOVE TO FRESH AIR. IF SYMPTOMS DEVELOP AND PERSIST, GET MEDICAL ATTENTION. SKIN CONTACT: WIPE OFF PASTE WITH PAPER TOWEL OR CLOTH. WASH WITH SOAP AND WATER. IF SYMPTOMS DEVELOP AND PERSIST, GET MEDICAL ATTENTION. EYE CONTACT: RINSE IMMEDIATELY WITH PLENTY OF WATER, ALSO UNDER THE EYELIDS, FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. IF SYMPTOMS DEVELOP AND PERSIST, GET MEDICAL ATTENTION. SYMPTOMS: SEE SECTION 11.
EXTINGUISHING MEDIA: WATER SPRAY (FOG), FOAM, DRY CHEMICAL OR CARBON DIOXIDE. DO NOT USE HIGH VOLUME WATER JET. SPECIAL FIREFIGHTING PROCEDURES: WEAR SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING, SUCH AS TURN-OUT GEAR. UNUSUAL FIRE OR EXPLOSION HAZARDS: IN CASE OF FIRE, KEEP CONTAINERS COOL WITH WATER SPRAY. HAZARDOUS COMBUSTION PRODUCTS: OXIDES OF CARBON. OXIDES OF SILICON. OXIDES OF NITROGEN. HYDROCARBONS. FORMALDEHYDE. IRRITATING ORGANIC VAPOURS.
USE PERSONAL PROTECTION RECOMMENDED IN SECTION 8, ISOLATE THE HAZARD AREA AND DENY ENTRY TO UNNECESSARY AND UNPROTECTED PERSONNEL. ENVIRONMENTAL PRECAUTIONS: DO NOT ALLOW PRODUCT TO ENTER SEWER OR WATERWAYS. CLEAN-UP METHODS: SCRAPE UP AS MUCH MATERIAL AS POSSIBLE. MAINTAIN GOOD VENTILATION FOR LARGE SPILLS. PLACE SCRAP MATERIAL IN A WELL VENTILATED AREA AND ALLOW TO CURE TO RUBBER.
HANDLING: PREVENT CONTACT WITH EYES, SKIN AND CLOTHING. DO NOT BREATHE VAPOR AND MIST. WASH THOROUGHLY AFTER HANDLING. DO NOT HANDLE CONTACT LENSES UNTIL ALL SEALANT HAS BEEN REMOVED FROM HANDS. RESIDUAL SEALANT MAY TRANSFER TO LENSES AND CAUSE EYE IRRITATION. STORAGE: FOR SAFE STORAGE, STORE BETWEEN 8 DEG. C (46.4 DEG. F) AND 28 DEG. C (82.4 DEG. F) STORE IN A DRY AREA BELOW 90 DEG. F. KEEP CONTAINER CLOSED.
EMPLOYERS SHOULD COMPLETE AN ASSESSMENT OF ALL WORKPLACES TO DETERMINE THE NEED FOR, AND SELECTION OF, PROPER EXPOSURE CONTROLS AND PROTECTIVE EQUIPMENT FOR EACH TASK PERFORMED. HAZARDOUS COMPONENT(S) ACGIH TLV OSHA PEL SILANE, DICHLORODIMETHYL-, 3 MG/M3 TWA 0.8 MG/M3 TWA REACTION PRODUCTS WITH SILICA RESPIRABLE PARTICLES. 20 MPPCF TWA 10 MG/M3 TWA INHALABLE PARTICLES. 50 MPPCF TWA TOTAL DUST. 15 MG/M3 TWA TOTAL DUST. 5 MG/M3 TWA RESPIRABLE FRACTION. 15 MPPCF TWA RESPIRABLE FRACTION. BUTAN-2-ONE O,O',O''- NONE NONE (VINYLSILYLIDYNE)TRIOXIME DIIRON TRIOXIDE 5 MG/M3 TWA 10 MG/M3 PEL FUME. RESPIRABLE FRACTION. 50 MPPCF TWA TOTAL DUST. 5 MG/M3 TWA RESPIRABLE FRACTION. 15 MG/M3 TWA TOTAL DUST. 15 MPPCF TWA RESPIRABLE FRACTION. MICA 0.1 MG/M3 TWA 20 MPPCF TWA RESPIRABLE FRACTION. 15 MG/M3 PEL TOTAL DUST. 5 MG/M3 PEL RESPIRABLE FRACTION. 2-BUTANONE OXIME NONE NONE HAZARDOUS COMPONENT(S) AIHA WEEL OTHER SILANE, DICHLORODIMETHYL-, REACTION NONE NONE PRODUCTS WITH SILICA BUTAN-2-ONE O,O',O''- NONE NONE (VINYLSILYLIDYNE)TRIOXIME DIIRON TRIOXIDE NONE NONE MICA NONE NONE 2-BUTANONE OXIME 10 PPM NONE (36 MG/M3) TWA (SKIN SENSITIZER.) ENGINEERING CONTROLS: PROVIDE ADEQUATE LOCAL EXHAUST VENTILATION TO MAINTAIN WORKER EXPOSURE BELOW EXPOSURE LIMITS. RESPIRATORY PROTECTION: USE A NIOSH APPROVED AIR-PURIFYING RESPIRATOR IF THE POTENTIAL TO EXCEED ESTABLISHED EXPOSURE LIMITS EXISTS. EYE/FACE PROTECTION: SAFETY GOGGLES OR SAFETY GLASSES WITH SIDE SHIELDS. SAFETY SHOWERS AND EYE WASH STATIONS SHOULD BE AVAILABLE. SKIN PROTECTION: CHEMICAL RESISTANT, IMPERMEABLE GLOVES. IMPERVIOUS CLOTHING.
PHYSICAL STATE: PASTE COLOR: COPPER ODOR: MILD ODOR THRESHOLD: NOT AVAILABLE. PH: NOT APPLICABLE VAPOR PRESSURE: <5 MM Hg (20 DEG. C (68 DEG. F)) BOILING POINT/RANGE: NOT APPLICABLE MELTING POINT/ RANGE: NOT AVAILABLE. SPECIFIC GRAVITY: 1.31 AT 20 DEG. C (68 DEG. F) VAPOR DENSITY: HEAVIER THAN AIR. FLASH POINT: >93 DEG. C (>199.4 DEG. F) TAGLIABUE CLOSED CUP FLAMMABLE/EXPLOSIVE LIMITS - LOWER: NOT APPLICABLE NOT APPLICABLE FLAMMABLE/EXPLOSIVE LIMITS - UPPER: NOT APPLICABLE NOT APPLICABLE AUTOIGNITION TEMPERATURE: NOT AVAILABLE. FLAMMABILITY: NOT APPLICABLE EVAPORATION RATE: NOT AVAILABLE. SOLUBILITY IN WATER: POLYMERISES IN PRESENCE OF WATER. PARTITION COEFFICIENT (N-OCTANOL/WATER): NOT AVAILABLE. VOC CONTENT: 0.59 % VISCOSITY: NOT AVAILABLE. DECOMPOSITION TEMPERATURE: NOT AVAILABLE.
STABILITY: STABLE AT NORMAL CONDITIONS. HAZARDOUS REACTIONS: NONE UNDER NORMAL PROCESSING. HAZARDOUS DECOMPOSITION PRODUCTS: METHYL ETHYL KETOXIME FORMED DURING CURE. OXIDES OF CARBON. OXIDES OF SILICON. OXIDES OF NITROGEN. IRRITATING VAPORS. HYDROCARBONS. FORMALDEHYDE. INCOMPATIBLE MATERIALS: POLYMERIZES ON CONTACT WITH WATER. OXIDIZING AGENTS. ACIDS AND BASES. REACTIVITY: NOT AVAILABLE. CONDITIONS TO AVOID: MOISTURE.
RELEVANT ROUTES OF EXPOSURE: SKIN, INHALATION, EYES, INGESTION POTENTIAL HEALTH EFFECTS/SYMPTOMS: INHALATION: INHALATION OF VAPORS OR MISTS OF THE PRODUCT MAY BE IRRITATING TO THE RESPIRATORY SYSTEM. WHEN HEATED TO TEMPERATURES EXCEEDING 300 DEG. F (150 DEG. C) IN THE PRESENCE OF AIR, SILICONES MAY FORM FORMALDEHYDE VAPORS. FORMALDEHYDE IS A POTENTIAL CANCER HAZARD AND A KNOWN SKIN AND RESPIRATORY SENSITIZER. VAPORS IRRITATE THE EYES, NOSE AND THROAT. SAFE HANDLING CONDITIONS MAY BE MAINTAINED BY KEEPING FORMALDEHYDE VAPOR CONCENTRATIONS BELOW THE OSHA PERMISSIBLE LIMIT. SKIN CONTACT: MAY CAUSE SKIN IRRITATION. MAY CAUSE ALLERGIC SKIN REACTION. EYE CONTACT: MAY CAUSE EYE IRRITATION. INGESTION: MAY BE HARMFUL IF SWALLOWED. NOT EXPECTED UNDER NORMAL CONDITIONS OF USE. HAZARDOUS COMPONENT(S) LD50S AND LC50S IMMEDIATE AND DELAYED HEALTH EFFECTS SILANE, DICHLORODIMETHYL-, NONE NO DATA REACTION PRODUCTS WITH SILICA BUTAN-2-ONE O,O',O''- NONE IRRITANT, ALLERGEN (VINYLSILYLIDYNE)TRIOXIME DIIRON TRIOXIDE NONE ALLERGEN, CARDIAC, CENTRAL NERVOUS SYSTEM, IRRITANT, KIDNEY, LIVER, LUNG MICA NONE LUNG 2-BUTANONE OXIME INHALATION ALLERGEN, BLOOD, CENTRAL LC50 (RAT, 4 H): NERVOUS SYSTEM, EYES, >4.83 MG/L IRRITANT, SOME EVIDENCE OF CARCINOGENICITY HAZARDOUS COMPONENT(S) NTP IARC OSHA CARCINOGEN CARCINOGEN CARCINOGEN (SPECIFICALLY REGULATED) SILANE, DICHLORODIMETHYL-, NO NO NO REACTION PRODUCTS WITH SILICA BUTAN-2-ONE O,O',O''- NO NO NO (VINYLSILYLIDYNE)TRIOXIME DIIRON TRIOXIDE NO NO NO MICA NO NO NO 2-BUTANONE OXIME NO NO NO
ECOLOGICAL INFORMATION: NOT AVAILABLE.
INFORMATION PROVIDED IS FOR UNUSED PRODUCT ONLY. RECOMMENDED METHOD OF DISPOSAL: CURED RUBBER CAN BE INCINERATED OR LANDFILLED FOLLOWING EPA AND LOCAL REGULATIONS. FOLLOW ALL LOCAL, STATE, FEDERAL AND PROVINCIAL REGULATIONS FOR DISPOSAL.
THE TRANSPORT INFORMATION PROVIDED IN THIS SECTION ONLY APPLIES TO THE MATERIAL/FORMULATION ITSELF, AND IS NOT SPECIFIC TO ANY PACKAGE/CONFIGURATION. U.S. DEPARTMENT OF TRANSPORTATION GROUND (49 CFR): PROPER SHIPPING NAME: NOT REGULATED HAZARD CLASS OR DIVISION: NONE IDENTIFICATION NUMBER: NONE PACKING GROUP: NONE INTERNATIONAL AIR TRANSPORTATION (ICAO/IATA): PROPER SHIPPING NAME: NOT REGULATED HAZARD CLASS OR DIVISION: NONE IDENTIFICATION NUMBER: NONE PACKING GROUP: NONE WATER TRANSPORTATION (IMO/IMDG): PROPER SHIPPING NAME: NOT REGULATED HAZARD CLASS OR DIVISION: NONE IDENTIFICATION NUMBER: NONE PACKING GROUP: NONE
UNITED STATES REGULATORY INFORMATION: TSCA 8 (B) INVENTORY STATUS: ALL COMPONENTS ARE LISTED AS ACTIVE OR ARE EXEMPT FROM LISTING ON THE TOXIC SUBSTANCES CONTROL ACT (TSCA) INVENTORY. TSCA 12 (B) EXPORT NOTIFICATION: NONE ABOVE REPORTING DE MINIMIS CERCLA/SARA SECTION 302 EHS: NONE ABOVE REPORTING DE MINIMIS. CERCLA/SARA SECTION 311/312: IMMEDIATE HEALTH, DELAYED HEALTH CERCLA/SARA SECTION 313: NONE ABOVE REPORTING DE MINIMIS. CALIFORNIA PROPOSITION 65: THIS PRODUCT CONTAINS A CHEMICAL KNOWN IN THE STATE OF CALIFORNIA TO CAUSE CANCER. THIS PRODUCT CONTAINS A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. CANADA REGULATORY INFORMATION: CEPA DSL/NDSL STATUS: CONTAINS ONE OR MORE COMPONENTS LISTED ON THE NON-DOMESTIC SUBSTANCES LIST. ALL OTHER COMPONENTS ARE LISTED ON OR ARE EXEMPT FROM LISTING ON THE DOMESTIC SUBSTANCES LIST. COMPONENTS LISTED ON THE NDSL MUST BE TRACKED BY ALL CANADIAN IMPORTERS OF RECORD AS REQUIRED BY ENVIRONMENT CANADA. THEY MAY BE IMPORTED INTO CANADA IN LIMITED QUANTITIES. PLEASE CONTACT REGULATORY AFFAIRS FOR ADDITIONAL DETAILS.
THIS SAFETY DATA SHEET CONTAINS CHANGES FROM THE PREVIOUS VERSION IN SECTIONS: 9 PREPARED BY: PRODUCT SAFETY AND REGULATORY AFFAIRS ISSUE DATE: 05/19/2022 DISCLAIMER: THE DATA CONTAINED HEREIN ARE FURNISHED FOR INFORMATION ONLY AND ARE BELIEVED TO BE RELIABLE. HOWEVER, HENKEL CORPORATION AND ITS AFFILIATES ("HENKEL") DOES NOT ASSUME RESPONSIBILITY FOR ANY RESULTS OBTAINED BY PERSONS OVER WHOSE METHODS HENKEL HAS NO CONTROL. IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE SUITABILITY OF HENKEL'S PRODUCTS OR ANY PRODUCTION METHODS MENTIONED HEREIN FOR A PARTICULAR PURPOSE, AND TO ADOPT SUCH PRECAUTIONS AS MAY BE ADVISABLE FOR THE PROTECTION OF PROPERTY AND PERSONS AGAINST ANY HAZARDS THAT MAY BE INVOLVED IN THE HANDLING AND USE OF ANY HENKEL'S PRODUCTS. IN LIGHT OF THE FOREGOING, HENKEL SPECIFICALLY DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARISING FROM SALE OR USE OF HENKEL'S PRODUCTS. HENKEL FURTHER DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING LOST PROFITS. THIS SAFETY DATA SHEET HAS BEEN GENERATED BASED ON OSHA HAZARD COMMUNICATION STANDARD (29 CFR 1910.1200) AND PROVIDES INFORMATION IN ACCORDANCE WITH U.S. FEDERAL LAW ONLY. NO WARRANTY OR REPRESENTATION OF ANY KIND IS GIVEN WITH RESPECT TO THE SUBSTANTIVE OR EXPORT LAWS OF ANY OTHER JURISDICTION OR COUNTRY. PLEASE CONFIRM THAT THE INFORMATION PROVIDED HEREIN CONFORMS TO THE SUBSTANTIVE EXPORT OR OTHER LAW OF ANY OTHER JURISDICTION PRIOR TO EXPORT. PLEASE CONTACT HENKEL PRODUCT SAFETY AND REGULATORY AFFAIRS FOR ADDITIONAL ASSISTANCE. |