Common Name: ABRASIVE PRODUCTS, 341D BELTS
Manufacturer: 3M
SDS Revision Date: 3/14/2014
SDS Format: GHS-US
   
Item Number(s): 4ZR52, 6RX76
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1: IDENTIFICATION 
SECTION 2: HAZARD IDENTIFICATION 
SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION 4: FIRST AID MEASURES 
SECTION 5: FIRE-FIGHTING MEASURES 
SECTION 6: ACCIDENTAL RELEASE MEASURES 
SECTION 7: HANDLING AND STORAGE 
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10: STABILITY AND REACTIVITY 
SECTION 11: TOXICOLOGICAL INFORMATION 
SECTION 12: ECOLOGICAL INFORMATION 
SECTION 13: DISPOSAL CONSIDERATIONS 
SECTION 14: TRANSPORT INFORMATION 
SECTION 15: REGULATORY INFORMATION 
SECTION 16: OTHER INFORMATION 



3M(TM) ABRASIVE PRODUCTS, 341D BELTS

03/14/14

3M

SAFETY DATA SHEET

COPYRIGHT, 2014, 3M COMPANY.

ALL RIGHTS RESERVED. COPYING AND/OR DOWNLOADING OF THIS INFORMATION FOR THE
PURPOSE OF PROPERLY UTILIZING 3M PRODUCTS IS ALLOWED PROVIDED THAT:
(1) THE INFORMATION IS COPIED IN FULL WITH NO CHANGES UNLESS PRIOR WRITTEN
AGREEMENT IS OBTAINED FROM 3M, AND

(2) NEITHER THE COPY NOR THE ORIGINAL IS RESOLD OR OTHERWISE DISTRIBUTED
WITH THE INTENTION OF EARNING A PROFIT THEREON.

DOCUMENT GROUP: 25-8517-2

VERSION NUMBER: 2.02

ISSUE DATE: 03/14/14

SUPERCEDES DATE: 03/22/13


SECTION 1: IDENTIFICATION 


1.1. PRODUCT IDENTIFIER: 3M(TM) ABRASIVE PRODUCTS, 341D BELTS

1.2. RECOMMENDED USE AND RESTRICTIONS ON USE:

RECOMMENDED USE: ABRASIVE PRODUCT

1.3. SUPPLIER'S DETAILS:

MANUFACTURER: 3M

DIVISION: ABRASIVE SYSTEMS DIVISION

ADDRESS:
3M CENTER
ST. PAUL, MN 55144-1000
USA

TELEPHONE: 1-888-3M HELPS (1-888-364-3577)

1.4. EMERGENCY TELEPHONE NUMBER:
1-800-364-3577 OR (651) 737-6501 (24 HOURS)


SECTION 2: HAZARD IDENTIFICATION 


2.1. HAZARD CLASSIFICATION:
NOT CLASSIFIED AS HAZARDOUS ACCORDING TO OSHA HAZARD COMMUNICATION
STANDARD, 29 CFR 1910.1200.

2.2. LABEL ELEMENTS:
SIGNAL WORD: NOT APPLICABLE.
SYMBOLS: NOT APPLICABLE.

PICTOGRAMS: NOT APPLICABLE.

NOTES TO PHYSICIAN: NOT APPLICABLE

2.3. HAZARDS NOT OTHERWISE CLASSIFIED: NONE.

24% OF THE MIXTURE CONSISTS OF INGREDIENTS OF UNKNOWN ACUTE ORAL TOXICITY.


SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 


INGREDIENT                               C.A.S. NO.           % BY WT

ALUMINUM OXIDE MINERAL (NON-FIBROUS)      1344-28-1            25 - 50

FILLER                                   13983-17-0             5 - 15

FILLER                                    1317-65-3           0.1 - 10

INORGANIC FLUORIDE                       15096-52-3             2 - 15

TITANIUM DIOXIDE                         13463-67-7           0.5 - 2

CURED RESIN                              MIXTURE               10 - 25

CLOTH BACKING                            NONE                   5 - 60


SECTION 4: FIRST AID MEASURES 


4.1. DESCRIPTION OF FIRST AID MEASURES:

INHALATION:
REMOVE PERSON TO FRESH AIR. IF YOU FEEL UNWELL, GET MEDICAL ATTENTION.

SKIN CONTACT:
WASH WITH SOAP AND WATER. IF SIGNS/SYMPTOMS DEVELOP, GET MEDICAL ATTENTION.

EYE CONTACT:
FLUSH WITH LARGE AMOUNTS OF WATER. REMOVE CONTACT LENSES IF EASY TO DO.
CONTINUE RINSING. IF SIGNS/SYMPTOMS PERSIST, GET MEDICAL ATTENTION.

IF SWALLOWED: NO NEED FOR FIRST AID IS ANTICIPATED.

4.2. MOST IMPORTANT SYMPTOMS AND EFFECTS, BOTH ACUTE AND DELAYED:
SEE SECTION 11.1. INFORMATION ON TOXICOLOGICAL EFFECTS.

4.3. INDICATION OF ANY IMMEDIATE MEDICAL ATTENTION AND SPECIAL TREATMENT
REQUIRED: NOT APPLICABLE


SECTION 5: FIRE-FIGHTING MEASURES 


5.1. SUITABLE EXTINGUISHING MEDIA:

IN CASE OF FIRE:
USE A FIRE FIGHTING AGENT SUITABLE FOR ORDINARY COMBUSTIBLE MATERIAL SUCH
AS WATER OR FOAM TO EXTINGUISH.

5.2. SPECIAL HAZARDS ARISING FROM THE SUBSTANCE OR MIXTURE:
EXPOSURE TO EXTREME HEAT CAN GIVE RISE TO THERMAL DECOMPOSITION.

HAZARDOUS DECOMPOSITION OR BY-PRODUCTS:

SUBSTANCE                CONDITION

CARBON MONOXIDE          DURING COMBUSTION

CARBON DIOXIDE           DURING COMBUSTION

HYDROGEN FLUORIDE        DURING COMBUSTION

5.3. SPECIAL PROTECTIVE ACTIONS FOR FIRE-FIGHTERS:
WHEN FIRE FIGHTING CONDITIONS ARE SEVERE AND TOTAL THERMAL DECOMPOSITION OF
THE PRODUCT IS POSSIBLE, WEAR FULL PROTECTIVE CLOTHING, INCLUDING HELMET,
SELF-CONTAINED, POSITIVE PRESSURE OR PRESSURE DEMAND BREATHING APPARATUS,
BUNKER COAT AND PANTS, BANDS AROUND ARMS, WAIST AND LEGS, FACE MASK, AND
PROTECTIVE COVERING FOR EXPOSED AREAS OF THE HEAD.


SECTION 6: ACCIDENTAL RELEASE MEASURES 


6.1. PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:
OBSERVE PRECAUTIONS FROM OTHER SECTIONS.

6.2. ENVIRONMENTAL PRECAUTIONS: AVOID RELEASE TO THE ENVIRONMENT.

6.3. METHODS AND MATERIAL FOR CONTAINMENT AND CLEANING UP: NOT APPLICABLE.


SECTION 7: HANDLING AND STORAGE 


7.1. PRECAUTIONS FOR SAFE HANDLING:
DO NOT BREATHE THERMAL DECOMPOSITION PRODUCTS. FOR INDUSTRIAL OR
PROFESSIONAL USE ONLY. DO NOT USE IN A CONFINED AREA WITH MINIMAL AIR
EXCHANGE. AVOID BREATHING OF DUST CREATED BY SANDING, GRINDING OR
MACHINING. DAMAGED PRODUCT CAN BREAK APART DURING USE AND CAUSE SERIOUS
INJURY TO FACE OR EYES. CHECK PRODUCT FOR DAMAGE SUCH AS CRACKS OR NICKS
PRIOR TO USE. REPLACE IF DAMAGED. ALWAYS WEAR EYE AND FACE PROTECTION WHEN
WORKING AT SANDING OR GRINDING OPERATIONS OR WHEN NEAR SUCH OPERATIONS.
AVOID RELEASE TO THE ENVIRONMENT. COMBUSTIBLE DUST MAY FORM BY ACTION OF
THIS PRODUCT ON ANOTHER MATERIAL (SUBSTRATE). DUST GENERATED FROM THE
SUBSTRATE DURING USE OF THIS PRODUCT MAY BE EXPLOSIVE IF IN SUFFICIENT
CONCENTRATION WITH AN IGNITION SOURCE. DUST DEPOSITS SHOULD NOT BE ALLOWED
TO ACCUMULATE ON SURFACES BECAUSE OF THE POTENTIAL FOR SECONDARY
EXPLOSIONS.

7.2. CONDITIONS FOR SAFE STORAGE INCLUDING ANY INCOMPATIBILITIES:
NO SPECIAL STORAGE REQUIREMENTS.


SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION 


8.1. CONTROL PARAMETERS:

OCCUPATIONAL EXPOSURE LIMITS:

INGREDIENT        C.A.S. NO.  AGENCY         LIMIT TYPE         ADDITIONAL
                                                                COMMENTS

FILLER             1317-65-3  US DEPT OF     TWA (AS TOTAL
                              LABOR - OSHA   DUST): 15 MG/M3

                                             TWA (RESPIRABLE
                                             FRACTION):
                                             5 MG/M3

ALUMINUM OXIDE     1344-28-1  CHEMICAL       TWA: 1 FIBER/CC
MINERAL (NON-                 MANUFACTURER
FIBROUS)                      REC GUID

ALUMINUM OXIDE     1344-28-1  US DEPT OF     TWA (AS TOTAL
MINERAL (NON-                 LABOR - OSHA   DUST): 15 MG/M3
FIBROUS)
                                             TWA (RESPIRABLE
                                             FRACTION):
                                             5 MG/M3

ALUMINUM,          1344-28-1  AMER CONF OF   TWA (RESPIRABLE
INSOLUBLE                     GOV. INDUST.   FRACTION):
COMPOUNDS                     HYG.           1 MG/M3

TITANIUM DIOXIDE  13463-67-7  AMER CONF OF   TWA: 10 MG/M3
                              GOV. INDUST.
                              HYG.

TITANIUM DIOXIDE  13463-67-7  CHEMICAL       TWA (AS
                              MANUFACTURER   RESPIRABLE DUST):
                              REC GUID       5 MG/M3

TITANIUM DIOXIDE  13463-67-7  US DEPT OF     TWA (AS TOTAL
                              LABOR - OSHA   DUST): 15 MG/M3

ALUMINUM,         15096-52-3  AMER CONF OF   TWA (RESPIRABLE
INSOLUBLE                     GOV. INDUST.   FRACTION):
COMPOUNDS                     HYG.           1 MG/M3

FLUORIDES         15096-52-3  AMER CONF OF   TWA (AS F):
                              GOV. INDUST.   2.5 MG/M3
                              HYG.

FLUORIDES         15096-52-3  US DEPT OF     TWA (AS DUST):
                              LABOR - OSHA   2.5 MG/M3

                                             TWA (AS F):
                                             2.5 MG/M3

AMER CONF OF GOV. INDUST. HYG.:
AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS

AMERICAN INDUST. HYGIENE ASSOC: AMERICAN INDUSTRIAL HYGIENE ASSOCIATION

CHEMICAL MANUFACTURER REC GUID:
CHEMICAL MANUFACTURER'S RECOMMENDED GUIDELINES

US DEPT OF LABOR - OSHA:
UNITED STATES DEPARTMENT OF LABOR - OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION

TWA: TIME-WEIGHTED-AVERAGE

STEL: SHORT TERM EXPOSURE LIMIT

CEIL: CEILING

8.2. EXPOSURE CONTROLS:

8.2.1. ENGINEERING CONTROLS:
FOR THOSE SITUATIONS WHERE THE MATERIAL MIGHT BE EXPOSED TO EXTREME
OVERHEATING DUE TO MISUSE OR EQUIPMENT FAILURE, USE WITH APPROPRIATE LOCAL
EXHAUST VENTILATION SUFFICIENT TO MAINTAIN LEVELS OF THERMAL DECOMPOSITION
PRODUCTS BELOW THEIR EXPOSURE GUIDELINES. PROVIDE APPROPRIATE LOCAL EXHAUST
VENTILATION FOR SANDING, GRINDING OR MACHINING. USE GENERAL DILUTION
VENTILATION AND/OR LOCAL EXHAUST VENTILATION TO CONTROL AIRBORNE EXPOSURES
TO BELOW RELEVANT EXPOSURE LIMITS AND/OR CONTROL
DUST/FUME/GAS/MIST/VAPORS/SPRAY. IF VENTILATION IS NOT ADEQUATE, USE
RESPIRATORY PROTECTION EQUIPMENT. PROVIDE LOCAL EXHAUST AT PROCESS EMISSION
SOURCES TO CONTROL EXPOSURE NEAR THE SOURCE AND TO PREVENT THE ESCAPE OF
DUST INTO THE WORK AREA. ENSURE THAT DUST-HANDLING SYSTEMS (SUCH AS EXHAUST
DUCTS, DUST COLLECTORS, VESSELS, AND PROCESSING EQUIPMENT) ARE DESIGNED IN
A MANNER TO PREVENT THE ESCAPE OF DUST INTO THE WORK AREA (I.E., THERE IS
NO LEAKAGE FROM THE EQUIPMENT).

8.2.2. PERSONAL PROTECTIVE EQUIPMENT (PPE):

EYE/FACE PROTECTION:
TO MINIMIZE THE RISK OF INJURY TO FACE AND EYES, ALWAYS WEAR EYE AND FACE
PROTECTION WHEN WORKING AT SANDING OR GRINDING OPERATIONS OR WHEN NEAR SUCH
OPERATIONS. SELECT AND USE EYE/FACE PROTECTION TO PREVENT CONTACT BASED ON
THE RESULTS OF AN EXPOSURE ASSESSMENT. THE FOLLOWING EYE/FACE PROTECTION(S)
ARE RECOMMENDED: SAFETY GLASSES WITH SIDE SHIELDS

SKIN/HAND PROTECTION:
WEAR APPROPRIATE GLOVES TO MINIMIZE RISK OF INJURY TO SKIN FROM CONTACT
WITH DUST OR PHYSICAL ABRASION FROM GRINDING OR SANDING.

RESPIRATORY PROTECTION:
ASSESS EXPOSURE CONCENTRATIONS OF ALL MATERIALS INVOLVED IN THE WORK
PROCESS. CONSIDER MATERIAL BEING ABRADED WHEN DETERMINING THE APPROPRIATE
RESPIRATORY PROTECTION. SELECT AND USE APPROPRIATE RESPIRATORS TO PREVENT
INHALATION OVEREXPOSURE. AN EXPOSURE ASSESSMENT MAY BE NEEDED TO DECIDE IF
A RESPIRATOR IS REQUIRED. IF A RESPIRATOR IS NEEDED, USE RESPIRATORS AS
PART OF A FULL RESPIRATORY PROTECTION PROGRAM. BASED ON THE RESULTS OF THE
EXPOSURE ASSESSMENT, SELECT FROM THE FOLLOWING RESPIRATOR TYPE(S) TO REDUCE
INHALATION EXPOSURE:
HALF FACEPIECE OR FULL FACEPIECE AIR-PURIFYING RESPIRATOR SUITABLE FOR
PARTICULATES

FOR QUESTIONS ABOUT SUITABILITY FOR A SPECIFIC APPLICATION, CONSULT WITH
YOUR RESPIRATOR MANUFACTURER.


SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 


9.1. INFORMATION ON BASIC PHYSICAL AND CHEMICAL PROPERTIES:

GENERAL PHYSICAL FORM: SOLID

ODOR, COLOR, GRADE: SOLID ABRASIVE PRODUCT

ODOR THRESHOLD: NOT APPLICABLE

PH: NOT APPLICABLE

MELTING POINT: NOT APPLICABLE

BOILING POINT: NOT APPLICABLE

FLASH POINT: NOT APPLICABLE

EVAPORATION RATE: NOT APPLICABLE

FLAMMABILITY (SOLID, GAS): NOT CLASSIFIED

FLAMMABLE LIMITS (LEL): NOT APPLICABLE
FLAMMABLE LIMITS (UEL): NOT APPLICABLE

VAPOR PRESSURE: NOT APPLICABLE

VAPOR DENSITY: NOT APPLICABLE

SPECIFIC GRAVITY: NOT APPLICABLE

SOLUBILITY IN WATER: NOT APPLICABLE

SOLUBILITY- NON-WATER: NOT APPLICABLE

AUTOIGNITION TEMPERATURE: NOT APPLICABLE

DECOMPOSITION TEMPERATURE: NOT APPLICABLE

VISCOSITY: NOT APPLICABLE


SECTION 10: STABILITY AND REACTIVITY 


10.1. REACTIVITY:
THIS MATERIAL IS CONSIDERED TO BE NON REACTIVE UNDER NORMAL USE CONDITIONS.

10.2. CHEMICAL STABILITY: STABLE.

10.3. POSSIBILITY OF HAZARDOUS REACTIONS:
HAZARDOUS POLYMERIZATION WILL NOT OCCUR.

10.4. CONDITIONS TO AVOID: NONE KNOWN.

10.5. INCOMPATIBLE MATERIALS: NONE KNOWN.

10.6. HAZARDOUS DECOMPOSITION PRODUCTS:

SUBSTANCE         CONDITION

NONE KNOWN.

REFER TO SECTION 5.2 FOR HAZARDOUS DECOMPOSITION PRODUCTS DURING
COMBUSTION.

IF THE PRODUCT IS EXPOSED TO EXTREME CONDITION OF HEAT FROM MISUSE OR
EQUIPMENT FAILURE, TOXIC DECOMPOSITION PRODUCTS THAT INCLUDE HYDROGEN
FLUORIDE AND PERFLUOROISOBUTYLENE CAN OCCUR. EXTREME HEAT ARISING FROM
SITUATIONS SUCH AS MISUSE OR EQUIPMENT FAILURE CAN GENERATE HYDROGEN
FLUORIDE AS A DECOMPOSITION PRODUCT.


SECTION 11: TOXICOLOGICAL INFORMATION 


THE INFORMATION BELOW MAY NOT BE CONSISTENT WITH THE MATERIAL
CLASSIFICATION IN SECTION 2 IF SPECIFIC INGREDIENT CLASSIFICATIONS ARE
MANDATED BY A COMPETENT AUTHORITY. IN ADDITION, TOXICOLOGICAL DATA ON
INGREDIENTS MAY NOT BE REFLECTED IN THE MATERIAL CLASSIFICATION AND/OR THE
SIGNS AND SYMPTOMS OF EXPOSURE, BECAUSE AN INGREDIENT MAY BE PRESENT BELOW
THE THRESHOLD FOR LABELING, AN INGREDIENT MAY NOT BE AVAILABLE FOR
EXPOSURE, OR THE DATA MAY NOT BE RELEVANT TO THE MATERIAL AS A WHOLE.

11.1. INFORMATION ON TOXICOLOGICAL EFFECTS:

SIGNS AND SYMPTOMS OF EXPOSURE:

BASED ON TEST DATA AND/OR INFORMATION ON THE COMPONENTS, THIS MATERIAL MAY
PRODUCE THE FOLLOWING HEALTH EFFECTS:

INHALATION:
DUST FROM GRINDING, SANDING OR MACHINING MAY CAUSE IRRITATION OF THE
RESPIRATORY SYSTEM. SIGNS/SYMPTOMS MAY INCLUDE COUGH, SNEEZING, NASAL
DISCHARGE, HEADACHE, HOARSENESS, AND NOSE AND THROAT PAIN.

SKIN CONTACT:

MECHANICAL SKIN IRRITATION:
SIGNS/SYMPTOMS MAY INCLUDE ABRASION, REDNESS, PAIN, AND ITCHING.

EYE CONTACT:

MECHANICAL EYE IRRITATION:
SIGNS/SYMPTOMS MAY INCLUDE PAIN, REDNESS, TEARING AND CORNEAL ABRASION.

DUST CREATED BY GRINDING, SANDING, OR MACHINING MAY CAUSE EYE IRRITATION.
SIGNS/SYMPTOMS MAY INCLUDE REDNESS, SWELLING, PAIN, TEARING, AND BLURRED OR
HAZY VISION.

INGESTION: NO HEALTH EFFECTS ARE EXPECTED.

CARCINOGENICITY:

INGREDIENT        C.A.S. NO.   CLASS DESCRIPTION     REGULATION

TITANIUM DIOXIDE  13463-67-7   GRP. 2B:              INTERNATIONAL AGENCY
                               POSSIBLE HUMAN CARC.  FOR RESEARCH ON CANCER

ADDITIONAL INFORMATION:
THIS DOCUMENT COVERS ONLY THE 3M PRODUCT. FOR COMPLETE ASSESSMENT, WHEN
DETERMINING THE DEGREE OF HAZARD, THE MATERIAL BEING ABRADED MUST ALSO BE
CONSIDERED.

THIS PRODUCT CONTAINS TITANIUM DIOXIDE. CANCER OF THE LUNGS HAS BEEN
OBSERVED IN RATS THAT INHALED HIGH LEVELS OF TITANIUM DIOXIDE. NO EXPOSURE
TO INHALED TITANIUM DIOXIDE IS EXPECTED DURING THE NORMAL HANDLING AND USE
OF THIS PRODUCT. TITANIUM DIOXIDE WAS NOT DETECTED WHEN AIR SAMPLING WAS
CONDUCTED DURING SIMULATED USE OF SIMILAR PRODUCTS CONTAINING TITANIUM
DIOXIDE. THEREFORE, THE HEALTH EFFECTS ASSOCIATED WITH TITANIUM DIOXIDE ARE
NOT EXPECTED DURING THE NORMAL USE OF THIS PRODUCT.

TOXICOLOGICAL DATA:
IF A COMPONENT IS DISCLOSED IN SECTION 3 BUT DOES NOT APPEAR IN A TABLE
BELOW, EITHER NO DATA ARE AVAILABLE FOR THAT ENDPOINT OR THE DATA ARE NOT
SUFFICIENT FOR CLASSIFICATION.

ACUTE TOXICITY:

NAME                          ROUTE         SPECIES     VALUE

OVERALL PRODUCT               INGESTION                 NO DATA AVAILABLE;
                                                        CALCULATED ATE:
                                                        >5,000 MG/KG

ALUMINUM OXIDE MINERAL        DERMAL                    LD50:
(NON-FIBROUS)                                           ESTIMATED TO BE
                                                        >5,000 MG/KG

ALUMINUM OXIDE MINERAL        INHALATION-   RAT         LC50: >2.3 MG/L
(NON-FIBROUS)                 DUST/MIST
                              (4 HOURS)

ALUMINUM OXIDE MINERAL        INGESTION     RAT         LD50: >5,000 MG/KG
(NON-FIBROUS)

FILLER                        DERMAL                    LD50:
                                                        ESTIMATED TO BE
                                                        >5,000 MG/KG

FILLER                        INGESTION                 LD50:
                                                        ESTIMATED TO BE
                                                        2,000 - 5,000 MG/KG

INORGANIC FLUORIDE            DERMAL        RABBIT      LD50: >2,100 MG/KG

INORGANIC FLUORIDE            INHALATION-   RAT         LC50: 4.5 MG/L
                              DUST/MIST
                              (4 HOURS)

INORGANIC FLUORIDE            INGESTION     RAT         LD50: 5,000 MG/KG

TITANIUM DIOXIDE              DERMAL        RABBIT      LD50: >10,000 MG/KG

TITANIUM DIOXIDE              INHALATION-   RAT         LC50: >6.82 MG/L
                              DUST/MIST
                              (4 HOURS)

TITANIUM DIOXIDE              INGESTION     RAT         LD50: >10,000 MG/KG

FILLER                        DERMAL        RAT         LD50: >2,000 MG/KG

FILLER                        INHALATION-   RAT         LC50: 3.0 MG/L
                              DUST/MIST
                              (4 HOURS)

FILLER                        INGESTION     RAT         LD50: 6,450 MG/KG

ATE = ACUTE TOXICITY ESTIMATE

SKIN CORROSION/IRRITATION:

NAME                             SPECIES        VALUE

ALUMINUM OXIDE MINERAL           RABBIT         NO SIGNIFICANT IRRITATION
(NON-FIBROUS)

INORGANIC FLUORIDE                              MINIMAL IRRITATION

TITANIUM DIOXIDE                 RABBIT         NO SIGNIFICANT IRRITATION

FILLER                           RABBIT         NO SIGNIFICANT IRRITATION

SERIOUS EYE DAMAGE/IRRITATION:

NAME                             SPECIES        VALUE

ALUMINUM OXIDE MINERAL           RABBIT         NO SIGNIFICANT IRRITATION
(NON-FIBROUS)

INORGANIC FLUORIDE                              MODERATE IRRITANT

TITANIUM DIOXIDE                 RABBIT         NO SIGNIFICANT IRRITATION

FILLER                           RABBIT         NO SIGNIFICANT IRRITATION

SKIN SENSITIZATION:

NAME                             SPECIES        VALUE

TITANIUM DIOXIDE                 HUMAN          NOT SENSITIZING
                                 AND
                                 ANIMAL

RESPIRATORY SENSITIZATION:

NAME                             SPECIES        VALUE

GERM CELL MUTAGENICITY:

NAME                             ROUTE          VALUE

ALUMINUM OXIDE MINERAL           IN VITRO       NOT MUTAGENIC
(NON-FIBROUS)

FILLER                           IN VITRO       NOT MUTAGENIC

TITANIUM DIOXIDE                 IN VITRO       NOT MUTAGENIC

TITANIUM DIOXIDE                 IN VIVO        NOT MUTAGENIC

CARCINOGENICITY:

NAME                         ROUTE        SPECIES      VALUE

ALUMINUM OXIDE MINERAL       INHALATION   RAT          NOT CARCINOGENIC
(NON-FIBROUS)

TITANIUM DIOXIDE             INGESTION    MULTIPLE     NOT CARCINOGENIC
                                          ANIMAL
                                          SPECIES

TITANIUM DIOXIDE             INHALATION   RAT          CARCINOGENIC

REPRODUCTIVE TOXICITY:

REPRODUCTIVE AND/OR DEVELOPMENTAL EFFECTS:

NAME         ROUTE            VALUE

FILLER       INGESTION        NOT TOXIC TO DEVELOPMENT


NAME         SPECIES       TEST RESULT              EXPOSURE DURATION

FILLER       RAT           NOAEL: 625 MG/KG/DAY     PREMATING & DURING
                                                    GESTATION

TARGET ORGAN(S):

SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE:

NAME        ROUTE          TARGET ORGAN(S)      VALUE

FILLER      INHALATION     RESPIRATORY SYSTEM   ALL DATA ARE NEGATIVE


NAME        SPECIES      TEST RESULT              EXPOSURE DURATION

FILLER      RAT          NOAEL: 0.812 MG/L        90 MINUTES

SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE:

NAME                   ROUTE       TARGET ORGAN(S)      VALUE

ALUMINUM OXIDE         INHALATION  PNEUMOCONIOSIS       SOME POSITIVE DATA
MINERAL (NON-FIBROUS)              PULMONARY FIBROSIS   EXIST, BUT THE DATA
                                                        ARE NOT SUFFICIENT
                                                        FOR CLASSIFICATION

FILLER                 INHALATION  RESPIRATORY SYSTEM   SOME POSITIVE DATA
                                                        EXIST, BUT THE DATA
                                                        ARE NOT SUFFICIENT
                                                        FOR CLASSIFICATION

FILLER                 INHALATION  PULMONARY FIBROSIS   ALL DATA ARE
                                                        NEGATIVE

INORGANIC FLUORIDE     INHALATION  BONE, TEETH, NAILS,  SOME POSITIVE DATA
                                   AND/OR HAIR          EXIST, BUT THE DATA
                                                        ARE NOT SUFFICIENT
                                                        FOR CLASSIFICATION

TITANIUM DIOXIDE       INHALATION  RESPIRATORY SYSTEM   SOME POSITIVE DATA
                                                        EXIST, BUT THE DATA
                                                        ARE NOT SUFFICIENT
                                                        FOR CLASSIFICATION

TITANIUM DIOXIDE       INHALATION  PULMONARY FIBROSIS   ALL DATA ARE
                                                        NEGATIVE

FILLER                 INHALATION  RESPIRATORY SYSTEM   SOME POSITIVE DATA
                                                        EXIST, BUT THE DATA
                                                        ARE NOT SUFFICIENT
                                                        FOR CLASSIFICATION


NAME               SPECIES    TEST RESULT                 EXPOSURE DURATION

ALUMINUM OXIDE     HUMAN      NOAEL: NOT AVAILABLE        OCCUPATIONAL
MINERAL                                                   EXPOSURE
(NON-FIBROUS)

FILLER             HUMAN      NOAEL: NOT AVAILABLE        OCCUPATIONAL
                                                          EXPOSURE

FILLER             HUMAN      NOAEL: NOT AVAILABLE
                   AND
                   ANIMAL

INORGANIC                     HHA
FLUORIDE

TITANIUM DIOXIDE   RAT        LOAEL: 0.010 MG/L           2 YEARS

TITANIUM DIOXIDE   HUMAN      NOAEL: NOT AVAILABLE        OCCUPATIONAL
                                                          EXPOSURE

FILLER             HUMAN      NOAEL: NOT AVAILABLE        OCCUPATIONAL
                                                          EXPOSURE

ASPIRATION HAZARD:

NAME                  VALUE

PLEASE CONTACT THE ADDRESS OR PHONE NUMBER LISTED IN SECTION 1 OF THIS
SDS FOR ADDITIONAL TOXICOLOGICAL INFORMATION ON THIS MATERIAL AND/OR ITS
COMPONENTS.


SECTION 12: ECOLOGICAL INFORMATION 


ECOTOXICOLOGICAL INFORMATION:
PLEASE CONTACT THE ADDRESS OR PHONE NUMBER LISTED IN SECTION 1 OF THIS
SDS FOR ADDITIONAL ECOTOXICOLOGICAL INFORMATION ON THIS MATERIAL AND/OR ITS
COMPONENTS.

CHEMICAL FATE INFORMATION:
PLEASE CONTACT THE ADDRESS OR PHONE NUMBER LISTED IN SECTION 1 OF THIS
SDS FOR ADDITIONAL CHEMICAL FATE INFORMATION ON THIS MATERIAL AND/OR ITS
COMPONENTS.


SECTION 13: DISPOSAL CONSIDERATIONS 


13.1. DISPOSAL METHODS:
DISPOSE OF CONTENTS/ CONTAINER IN ACCORDANCE WITH THE
LOCAL/REGIONAL/NATIONAL/INTERNATIONAL REGULATIONS.

THE SUBSTRATE THAT WAS ABRADED MUST BE CONSIDERED AS A FACTOR IN THE
DISPOSAL METHOD FOR THIS PRODUCT. DISPOSE OF WASTE PRODUCT IN A PERMITTED
INDUSTRIAL WASTE FACILITY. AS A DISPOSAL ALTERNATIVE, INCINERATE IN A
PERMITTED WASTE INCINERATION FACILITY. PROPER DESTRUCTION MAY REQUIRE THE
USE OF ADDITIONAL FUEL DURING INCINERATION PROCESSES. COMBUSTION PRODUCTS
WILL INCLUDE HALOGEN ACID (HCL/HF/HBR). FACILITY MUST BE CAPABLE OF
HANDLING HALOGENATED MATERIALS.

EPA HAZARDOUS WASTE NUMBER (RCRA): NOT REGULATED


SECTION 14: TRANSPORT INFORMATION 


NOT REGULATED PER U.S. DOT, IATA OR IMO.

THESE TRANSPORTATION CLASSIFICATIONS ARE PROVIDED AS A CUSTOMER SERVICE. AS
THE SHIPPER YOU REMAIN RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE LAWS
AND REGULATIONS, INCLUDING PROPER TRANSPORTATION CLASSIFICATION AND
PACKAGING. 3M TRANSPORTATION CLASSIFICATIONS ARE BASED ON PRODUCT
FORMULATION, PACKAGING, 3M POLICIES AND 3M UNDERSTANDING OF APPLICABLE
CURRENT REGULATIONS. 3M DOES NOT GUARANTEE THE ACCURACY OF THIS
CLASSIFICATION INFORMATION. THIS INFORMATION APPLIES ONLY TO TRANSPORTATION
CLASSIFICATION AND NOT THE PACKAGING, LABELING, OR MARKING REQUIREMENTS.
THE ORIGINAL 3M PACKAGE IS CERTIFIED FOR U.S. GROUND SHIPMENT ONLY. IF YOU
ARE SHIPPING BY AIR OR OCEAN, THE PACKAGE MAY NOT MEET APPLICABLE
REGULATORY REQUIREMENTS.


SECTION 15: REGULATORY INFORMATION 


15.1. US FEDERAL REGULATIONS: CONTACT 3M FOR MORE INFORMATION.

311/312 HAZARD CATEGORIES:
FIRE HAZARD: NO
PRESSURE HAZARD: NO
REACTIVITY HAZARD: NO
IMMEDIATE HAZARD: NO
DELAYED HAZARD: NO

15.2. STATE REGULATIONS: CONTACT 3M FOR MORE INFORMATION.

15.3. CHEMICAL INVENTORIES:
THIS PRODUCT IS AN ARTICLE AS DEFINED BY TSCA REGULATIONS, AND IS EXEMPT
FROM TSCA INVENTORY LISTING REQUIREMENTS.

CONTACT 3M FOR MORE INFORMATION.

15.4. INTERNATIONAL REGULATIONS: CONTACT 3M FOR MORE INFORMATION.

THIS SDS HAS BEEN PREPARED TO MEET THE U.S. OSHA HAZARD COMMUNICATION
STANDARD, 29 CFR 1910.1200.


SECTION 16: OTHER INFORMATION 


NFPA HAZARD CLASSIFICATION:
HEALTH          0
FLAMMABILITY    1
INSTABILITY     0
SPECIAL HAZARDS NONE

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) HAZARD RATINGS ARE DESIGNED FOR
USE BY EMERGENCY RESPONSE PERSONNEL TO ADDRESS THE HAZARDS THAT ARE
PRESENTED BY SHORT-TERM, ACUTE EXPOSURE TO A MATERIAL UNDER CONDITIONS OF
FIRE, SPILL, OR SIMILAR EMERGENCIES. HAZARD RATINGS ARE PRIMARILY BASED ON
THE INHERENT PHYSICAL AND TOXIC PROPERTIES OF THE MATERIAL BUT ALSO INCLUDE
THE TOXIC PROPERTIES OF COMBUSTION OR DECOMPOSITION PRODUCTS THAT ARE KNOWN
TO BE GENERATED IN SIGNIFICANT QUANTITIES.

HMIS HAZARD CLASSIFICATION:
HEALTH              0
FLAMMABILITY        1
PHYSICAL HAZARD     0
PERSONAL PROTECTION X - SEE PPE SECTION.

HAZARDOUS MATERIAL IDENTIFICATION SYSTEM (HMIS(R*) III) HAZARD RATINGS ARE
DESIGNED TO INFORM EMPLOYEES OF CHEMICAL HAZARDS IN THE WORKPLACE. THESE
RATINGS ARE BASED ON THE INHERENT PROPERTIES OF THE MATERIAL UNDER EXPECTED
CONDITIONS OF NORMAL USE AND ARE NOT INTENDED FOR USE IN EMERGENCY
SITUATIONS. HMIS(R*) III RATINGS ARE TO BE USED WITH A FULLY IMPLEMENTED
HMIS(R*) III PROGRAM. HMIS(R*) IS A REGISTERED MARK OF THE AMERICAN
COATINGS ASSOCIATION (ACA).

DOCUMENT GROUP: 25-8517-2

VERSION NUMBER: 2.02

ISSUE DATE: 03/14/14

SUPERCEDES DATE: 03/22/13

DISCLAIMER:
THE INFORMATION IN THIS SAFETY DATA SHEET (SDS) IS BELIEVED TO BE CORRECT
AS OF THE DATE ISSUED. 3M MAKES NO WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE OR COURSE OF PERFORMANCE OR USAGE OF
TRADE. USER IS RESPONSIBLE FOR DETERMINING WHETHER THE 3M PRODUCT IS FIT
FOR A PARTICULAR PURPOSE AND SUITABLE FOR USER'S METHOD OF USE OR
APPLICATION. GIVEN THE VARIETY OF FACTORS THAT CAN AFFECT THE USE AND
APPLICATION OF A 3M PRODUCT, SOME OF WHICH ARE UNIQUELY WITHIN THE USER'S
KNOWLEDGE AND CONTROL, IT IS ESSENTIAL THAT THE USER EVALUATE THE 3M
PRODUCT TO DETERMINE WHETHER IT IS FIT FOR A PARTICULAR PURPOSE AND
SUITABLE FOR USER'S METHOD OF USE OR APPLICATION.

3M PROVIDES INFORMATION IN ELECTRONIC FORM AS A SERVICE TO ITS CUSTOMERS.
DUE TO THE REMOTE POSSIBILITY THAT ELECTRONIC TRANSFER MAY HAVE RESULTED IN
ERRORS, OMISSIONS OR ALTERATIONS IN THIS INFORMATION, 3M MAKES NO
REPRESENTATIONS AS TO ITS COMPLETENESS OR ACCURACY. IN ADDITION,
INFORMATION OBTAINED FROM A DATABASE MAY NOT BE AS CURRENT AS THE
INFORMATION IN THE SDS AVAILABLE DIRECTLY FROM 3M

3M USA SDSS ARE AVAILABLE AT WWW.3M.COM