SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. ACMARCA PACER TECHNOLOGY SAFETY DATA SHEET DATE ISSUED: 01/03/2019 MSDS NO: 11711001
PRODUCT DESCRIPTION: SGC TOTAL TECH WHITE CARTRIDGE 290ML (9.8 FL OZ) MANUFACTURER: PACER TECHNOLOGY 3281 E. GUASTI RD., SUITE 260 ONTARIO, CA 91761 EMERGENCY CONTACT: CHEMTREC EMERGENCY PHONE: 800-424-9300 ALTERNATE EMERGENCY PHONE: 703-527-3887 PRODUCT STEWARDSHIP: 909-987-0550 24 HR. EMERGENCY TELEPHONE NUMBERS: CHEMTREC: (800) 424-9300
GHS LABEL ELEMENTS: EXCLAMATION MARK SIGNAL WORD: WARNING HAZARD STATEMENTS: H319: CAUSES SERIOUS EYE IRRITATION. PRECAUTIONARY STATEMENT(S): PREVENTION: P264: WASH HANDS THOROUGHLY AFTER HANDLING. P281: WEAR EYE PROTECTION. RESPONSE: P305+310+P338+351: IF IN EYES: RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES. REMOVE CONTACT LENSES, IF PRESENT AND EASY TO DO. CONTINUE RINSING. IMMEDIATELY CALL A POISON CENTER OR DOCTOR.
CHEMICAL NAME WT.% CAS CALCIUM CARBONATE 20 - 30 471-34-1 CALCIUM CARBONATE (LIMESTONE) <25 1317-65-3 TITANIUM DIOXIDE <5 13463-67-7 3-(TRIMETHOXYSILYL)PROPYLAMINE <1 13822-56-5 BIS (2,2,6,6-TETRAMETHYL-4-PIPERIDYL) SEBACATE <0.5 52829-07-9
EYES: IMMEDIATELY FLUSH EYES WITH LARGE QUANTITIES OF WATER FOR 15 MINUTES, WHILE HOLDING THE EYELIDS APART. REMOVE CONTACT LENSES IF EASY TO DO SO. CONTINUE RINSING. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN: WASH WITH SOAP AND WATER. GET MEDICAL ATTENTION IF IRRITATION OR SYMPTOMS OF EXPOSURE DEVELOP. REMOVE AND LAUNDER CONTAMINATED CLOTHING BEFORE RE-USE. INGESTION: DO NOT INDUCE VOMITING UNLESS DIRECTED TO DO SO BY MEDICAL PERSONNEL. IF IRRITATION OR DISCOMFORT OCCURS, GET MEDICAL ATTENTION. INHALATION: REMOVE VICTIM TO FRESH AIR. GET MEDICAL ATTENTION IF YOU FEEL UNWELL. SIGNS AND SYMPTOMS OF OVEREXPOSURE: EYES: DIRECT CONTACT WITH ADHESIVE MAY CAUSE MODERATE EYE IRRITATION. PROLONGED CONTACT WITH ADHESIVE MAY CAUSE DRYING OF THE SKIN.
GENERAL HAZARD: NOT CLASSIFIED AS FLAMMABLE OR COMBUSTIBLE. COMBUSTION WILL PRODUCE OXIDES OF CARBON AND BLACK SMOKE. EXTINGUISHING MEDIA: USE WATER FOG OR SPRAY, FOAM, CARBON DIOXIDE OR DRY CHEMICAL. FIRE FIGHTING EQUIPMENT: WEAR AN APPROVED, POSITIVE PRESSURE, SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING. USE WATER TO COOL EXPOSED CONTAINERS AND DISPERSE FLAMMABLE VAPORS.
SMALL SPILL: COVER WITH AN INERT ABSORBENT MATERIAL AND COLLECT INTO AN APPROPRIATE CONTAINER FOR DISPOSAL. AVOID RELEASES TO THE ENVIRONMENT. REPORT SPILLS AND RELEASES AS REQUIRED TO APPROPRIATE AUTHORITIES. SPECIAL PROTECTIVE EQUIPMENT: AVOID CONTACT WITH EYES, SKIN OR CLOTHING. WEAR APPROPRIATE PROTECTIVE CLOTHING TO AVOID EYE AND SKIN CONTACT.
HANDLING: AVOID CONTACT WITH THE EYES, SKIN, AND CLOTHING. WEAR APPROPRIATE PROTECTIVE CLOTHING AS DESCRIBED IN SECTION 8. WASH THOROUGHLY AFTER HANDLING. KEEP AWAY FROM FLAMES AND SOURCES OF IGNITION. STORAGE: STORE IN A CONTAINER IN A COOL, DRY, WELL-VENTILATED LOCATION AWAY FROM HEAT, SUNLIGHT AND INCOMPATIBLE MATERIALS. KEEP IN ORIGINAL CONTAINER. PREVENT MOISTURE CONTACT. KEEP CONTAINER TIGHTLY CLOSED WHEN NOT IN USE.
ENGINEERING CONTROLS: USE WITH ADEQUATE GENERAL OR LOCAL EXHAUST VENTILATION TO MAINTAIN EXPOSURE LEVELS BELOW THE OCCUPATIONAL EXPOSURE LIMITS. PERSONAL PROTECTIVE EQUIPMENT: EYES AND FACE: CHEMICAL SAFETY GOGGLES ARE RECOMMENDED IF NEEDED TO AVOID EYE CONTACT. SKIN: IMPERVIOUS GLOVES ARE SUGGESTED TO PREVENT SKIN CONTACT. CONTACT YOUR GLOVE SUPPLIER FOR SELECTION ASSISTANCE. RESPIRATORY: NONE REQUIRED FOR NORMAL USE. RESPIRATOR SELECTION AND USE SHOULD BE BASED ON CONTAMINANT TYPE, FORM, AND CONCENTRATION. FOLLOW APPLICABLE REGULATIONS AND GOOD INDUSTRIAL HYGIENE PRACTICE.
ODOR: ODORLESS ODOR THRESHOLD: NO DATA AVAILABLE APPEARANCE: WHITE PASTE PH: NO DATA AVAILABLE FLASHPOINT AND METHOD: 140C (284F) FLAMMABLE LIMITS: NO DATA AVAILABLE AUTOIGNITION TEMPERATURE: NO DATA AVAILABLE VAPOR PRESSURE: NO DATA AVAILABLE VAPOR DENSITY: NO DATA AVAILABLE BOILING POINT: 732C (1349.6F) FREEZING POINT: NO DATA AVAILABLE MELTING POINT: NO DATA AVAILABLE SOLUBILITY IN WATER: NO DATA AVAILABLE PARTITION COEFFICIENT N-OCTANOL/WATER: NO DATA AVAILABLE SPECIFIC GRAVITY: 1.058
REACTIVITY: NOT REACTIVE HAZARDOUS POLYMERIZATION: HAZARDOUS POLYMERIZATION WILL NOT OCCUR. STABILITY: STABLE UNDER NORMAL CONDITIONS. CONDITIONS TO AVOID: KEEP AWAY FROM HEAT AND OPEN FLAMES. HAZARDOUS DECOMPOSITION PRODUCTS: THERMAL DECOMPOSITION WILL PRODUCE OXIDES OF CARBON AND BLACK SMOKE. INCOMPATIBLE MATERIALS: STRONG OXIDIZING AGENTS, STRONG ACIDS, AND STRONG BASES.
ACUTE TOXICITY: NOTES: CALCIUM CARBONATE: ORAL RAT LD50: >2000 MG/KG LIMESTONE: ORAL RAT LD50: 6450 MG/KG TITANIUM DIOXIDE: ORAL RAT LD50: >2000 MG/KG INHALATION RAT LC50: 3.43 MG/L/4HR (NO MORTALITY) 3-(TRIMETHOXYSILYL)PROPYLAMINE: ORAL RAT LD50: 2.97 ML/KG SKIN RABBIT LD50: 11.3 ML/KG BIS(2,2,6,6-TETRAMETHYL-4-PIPERIDYL) SEBACATE: ORAL RAT LD50: 3700 MG/KG INHALATION RAT LC50: 500 MG/M3/4HR (AS MIST) SKIN RAT LD50: >3170 MG/KG SKIN CORROSION/IRRITATION: PROLONGED SKIN CONTACT MAY CAUSE SKIN IRRITATION WITH REDNESS, ITCHING, AND DRYING OF THE SKIN. SERIOUS EYE DAMAGE/IRRITATION: CONTACT WITH PRODUCT MAY CAUSE MODERATE EYE IRRITATION. RESPIRATORY OR SKIN SENSITISATION: THIS PRODUCT IS NOT EXPECTED TO CAUSE SKIN SENSITIZATION. GERM CELL MUTAGENICITY: THIS PRODUCT IS NOT EXPECTED TO CAUSE GERM CELL MUTAGENICITY. CARCINOGENICITY: NOTES: TITANIUM DIOXIDE IS LISTED AS POSSIBLE CARCINOGEN TO HUMANS (GROUP 2B) BY IARC. HOWEVER, THE TITANIUM DIOXIDE IN THIS PRODUCT IS INEXTRICABLY BOUND IN A MANNER THAT NO EXPOSURE OCCURS DURING NORMAL USE AND HANDLING. THEREFORE, THIS PRODUCT IS NOT CLASSIFIED AS A CARCINOGEN. NONE OF THE OTHER COMPONENTS OF THIS PRODUCT ARE LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN BY IARC, NTP, ACGIH, OSHA, OR EU CLP.
ECOTOXICOLOGICAL INFORMATION: NO DATA AVAILABLE FOR THE MIXTURE. THIS PRODUCT IS EXPECTED TO BE HARMFUL TO THE AQUATIC ENVIRONMENT WITH LONG-TERM ADVERSE EFFECTS. RELEASES TO THE ENVIRONMENT SHOULD BE AVOIDED. BIOACCUMULATION/ACCUMULATION: NO DATA AVAILABLE
DISPOSAL METHOD: DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS.
DOT (DEPARTMENT OF TRANSPORTATION): PROPER SHIPPING NAME: NOT REGULATED AIR (ICAO/IATA): SHIPPING NAME: NOT REGULATED VESSEL (IMO/IMDG): SHIPPING NAME: NOT REGULATED COMMENTS: THE TRANSPORT INFORMATION PROVIDED IN THIS SECTION ONLY APPLIES TO THE MATERIAL FORMULATION/ITSELF, AND IS NOT SPECIFIC TO ANY PACKAGE/ CONFIGURATION. THIS INFORMATION IS NOT INTENDED TO CONVEY ALL SPECIFIC REGULATORY OR OPERATIONAL REQUIREMENTS/INFORMATION RELATING TO THIS PRODUCT. TRANSPORTATION CLASSIFICATIONS MAY VARY BY CONTAINER VOLUME AND MAY BE INFLUENCED BY REGIONAL OR COUNTRY VARIATIONS IN REGULATIONS. IT IS THE RESPONSIBILITY OF THE TRANSPORTING ORGANIZATIONS TO FOLLOW ALL APPLICABLE LAWS, REGULATIONS, AND RULES RELATING TO THE TRANSPORTATION OF THE MATERIAL.
UNITED STATES: SARA TITLE III (SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT): 311/312 HEALTH HAZARDS: SEE OSHA HAZARD CLASSIFICATIONS IN SECTION 2. 313 REPORTABLE INGREDIENTS: NONE CERCLA (COMPREHENSIVE RESPONSE, COMPENSATION, AND LIABILITY ACT): CERCLA RQ: THIS PRODUCT IS NOT SUBJECT TO REPORTING UNDER CERCLA. SOME STATES HAVE MORE STRINGENT REPORTING REQUIREMENTS. REPORT ALL SPILLS IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS. TSCA (TOXIC SUBSTANCE CONTROL ACT): CHEMICAL NAME CAS CALCIUM CARBONATE 471-34-1 CALCIUM CARBONATE (LIMESTONE) 1317-65-3 3-(TRIMETHOXYSILYL)PROPYLAMINE 13822-56-5 TSCA STATUS: ALL OF THE INGREDIENTS OF THIS PRODUCT ARE LISTED ON THE TSCA INVENTORY. CALIFORNIA PROPOSITION 65: WARNING: THIS PRODUCT CAN EXPOSE YOU TO CHEMICALS INCLUDING METHANOL, WHICH IS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. FOR MORE INFORMATION GO TO WWW.P65WARNINGS.CA.GOV. NOTE: THE TITANIUM DIOXIDE IN THIS PRODUCT IS INEXTRICABLY BOUND. REGULATION APPLIES WHEN TITANIUM DIOXIDE IS AIRBORNE AND IN UNBOUND PARTICLES OF RESPIRABLE SIZE.
APPROVED BY: PACER TECHNOLOGY REGULATORY DEPARTMENT PREPARED BY: PACER TECHNOLOGY REGULATORY DEPARTMENT DATE PREPARED: 01/03/2019 HMIS RATING: HEALTH 2 FLAMMABILITY 1 PHYSICAL HAZARD 0 PERSONAL PROTECTION NFPA CODES: 2 1 0 MANUFACTURER DISCLAIMER: TO THE BEST OF OUR KNOWLEDGE, THE INFORMATION CONTAINED HEREIN IS ACCURATE. HOWEVER, PACER TECHNOLOGY DOES NOT ASSUME ANY LIABILITY FOR THE ACCURACY OR COMPLETENESS OF THE INFORMATION CONTAINED HEREIN. FINAL DETERMINATION OF SUITABILITY OF ANY MATERIAL IS THE SOLE RESPONSIBILITY OF THE USER. ALL MATERIALS MAY PRESENT UNKNOWN HAZARDS AND SHOULD BE USED WITH CAUTION. ALTHOUGH CERTAIN HAZARDS ARE DESCRIBED HEREIN, WE CANNOT GUARANTEE THAT THESE ARE THE ONLY HAZARDS WHICH EXIST. |