SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. CITY TECHNOLOGY ENGINEERING SAFETY PSDS SENSORIC HYDROUS ELECTROLYTE PRODUCT SAFETY DATASHEET
ELECTROCHEMICAL SENSORS FOR DETECTION OF TOXIC GAS. Cl2 3E 10 Cl2 3E 50 NO2 3E 50 NH3 3E 100 SE NH3 3E 500 SE NH3 3E 1000 SE NH3 3E 5000 SE HF 3E 10 S HF 3E 10 SE MANUFACTURER: SENSORIC GAS SENSORS - A DIVISION OF LIFE SAFETY GERMANY GMBH JUSTUS-VON-LIEBIG-STR. 22, 53121 BONN GERMANY PHONE: +49 (0)228 52 66 40 FAX: +49 (0)228 62 40 76 EMAIL: SALES EUROPE@CITYTECH.COM WEBSITE: WWW.CITYTECH.COM
ABS PLASTIC HOUSINGS, PROPRIETARY NOBLE METAL CATALYST ELECTRODES, HALOGEN FREE ORGANIC SOLVENTS, ACRYLAMIDE (Cl2 AND NO2 SENSORS), INORGANIC NON TOXIC SALTS.
THE ELECTROLYTE INSIDE THE SENSOR CONSTITUTES THE MAIN POTENTIAL HAZARD. THIS MAY LEAK OUT SHOULD THE HOUSING BE DAMAGED OR TAMPERED WITH. 3.1. INHALATION OF ELECTROLYTE: INHALATION IS NOT AN EXPECTED HAZARD UNLESS HEATED TO HIGH TEMPERATURES. HARMFUL IF INHALED. 3.2. INGESTION ELECTROLYTE: HARMFUL IF SWALLOWED. INGESTION OF Cl2 AND NO2 ELECTROLYTE MAY CAUSE NERVOUS SYSTEM DISTURBANCES. 3.3. SKIN OR EYE CONTACT OF ELECTROLYTE: MAY CAUSE SKIN IRRITATION. 3.4 AGGRAVATION OF PRE-EXISTING CONDITIONS: PERSONS WITH PRE-EXISTING SKIN DISORDERS, EYE PROBLEMS OR CENTRAL OR PERIPHERAL NERVOUS SYSTEM CONDITIONS MAY BE MORE SUSCEPTIBLE TO THE EFFECTS OF THIS SUBSTANCE. 3.5 CHRONIC HEALTH HAZARDS: PROLONGED OR REPEATED EXPOSURE TO Cl2 AND NO2 ELECTROLYTE MAY CASE REPRODUCTIVE DISORDERS AND /OR CANCER. RISK OF CANCER DEPENDS ON LEVEL AND DURATION OF EXPOSURE.
IN CASE OF LEAKAGE AND: 4.1. EYE CONTACT WITH ELECTROLYTE: IRRIGATE THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES. OBTAIN MEDICAL ADVICE. 4.2. INHALATION OF ELECTROLYTE: REMOVE TO FRESH AIR. REST AND KEEP WARM. OBTAIN MEDICAL ADVICE IF APPLICABLE. 4.3. SKIN CONTACT WITH ELECTROLYTE: IMMEDIATELY FLUSH THE SKIN THOROUGHLY WITH SOAP AND COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. REMOVE CONTAMINATED CLOTHING AND WASH BEFORE RE-USE. OBTAIN MEDICAL ADVICE IF CONTINUED IRRITATION. 4.4. INGESTION OF ELECTROLYTE: IF SWALLOWED DO NOT INDUCE VOMITING. WASH OUT MOUTH THOROUGHLY WITH WATER AND GIVE PLENTY OF WATER TO DRINK. OBTAIN MEDICAL ADVICE.
5.1. FIRE: NOT CONSIDERED TO BE A ARE HAZARD. 5.2. EXPLOSION: NOT CONSIDERED TO BE AN EXPLOSION HAZARD. 5.3. FIRE EXTINGUISHING MEDIA: USE ANY MEANS SUITABLE FOR EXTINGUISHING SURROUNDING ARE.
DAMAGE: SHOULD ANY SENSORIC GAS SENSOR BE SO SEVERELY DAMAGED OR TAMPERED WITH THAT THE LEAKAGE OF THE CONTENTS OCCURS THEN THE FOLLOWING PROCEDURES SHOULD BE ADOPTED: AVOID SKIN CONTACT WITH ANY LIQUID OR INTERNAL COMPONENT THROUGH THE USE OF PROTECTIVE GLOVES. DISCONNECT SENSORIC GAS SENSOR IF IT IS ATTACHED TO ANY EQUIPMENT. USE COPIOUS AMOUNTS OF CLEAN WATER TO WASH AWAY ANY SPILT ELECTROLYTE, PARTICULARLY IMPORTANT IN EQUIPMENT BECAUSE OF THE CORROSIVE NATURE OF THE ELECTROLYTE. OBSERVE FIRST AID MEASURES IN CASE OF EYE CONTACT, INHALATION, SKIN CONTACT OR INGESTION OF ELECTROLYTE.
MUST NOT BE EXPOSED TO TEMPERATURES OUTSIDE THE RANGE SPECIFIED ON THE SPECIFICATION SHEET. SHOULD NOT BE EXPOSED TO ORGANIC VAPORS, WHICH MAY CAUSE PHYSICAL DAMAGE TO THE BODY OF THE SENSOR. MUST NOT BE STORED IN AREAS CONTAINING ORGANIC SOLVENTS OR IN FLAMMABLE LIQUID STORES.
NONE IN NORMAL OPERATION
COLOUR CODED SENSORS IN PLASTIC HOUSING WITH CONNECTION PINS OR FLYING LEADS SENSOR IS A SEALED UNIT
N/A
TO THE BEST MANUFACTURER'S KNOWLEDGE, THE TOXICOLOGICAL PROPERTIES HAVE NOT BEEN THOROUGHLY INVESTIGATED.
HARMFUL TO AQUATIC LIFE.
CONTAINS TOXIC COMPOUNDS IRRESPECTIVE OF PHYSICAL CONDITION. SHOULD BE DISPOSED OF ACCORDING TO LOCAL WASTE MANAGEMENT REQUIREMENTS AND ENVIRONMENTAL LEGISLATION. SHOULD NOT BE BURNT SINCE THEY MAY EVOLVE TOXIC FUMES.
SENSORIC GAS SENSORS ARE CLASSIFIED AS "BATTERIES WET NON-SPILLABLE" (UN2800). THEY ARE TRANSPORTED AS PER IATA PI 872 AND 49 CFR 173.159A, AND NEED NO SPECIAL PACKAGING, LABELS ETC. AS THEY ARE NOT RESTRICTED AS PER IATA SPECIAL PROVISION A67.
HAZARD STATEMENTS: H302: HARMFUL IF SWALLOWED. H412: HARMFUL TO AQUATIC LIFE WITH LONG LASTING EFFECTS. PRECAUTIONARY STATEMENT: P273: AVOID RELEASE TO THE ENVIRONMENT. THE FOLLOWING HAZARD AND PRECAUTIONARY STATEMENTS ARE EXCLUSIVE FOR Cl2 AND NO2 ELECTROLYTE. HAZARD STATEMENTS: H302 + H332: HARMFUL IF SWALLOWED OR IF INHALED H315: CAUSES SKIN IRRITATION. H317: MAY CAUSE AN ALLERGIC SKIN REACTION. H319: CAUSES SERIOUS EYE IRRITATION. H340: MAY CAUSE GENETIC DEFECTS. H350: MAY CAUSE CANCER. H361F: SUSPECTED OF DAMAGING FERTILITY. H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE. PRECAUTIONARY STATEMENT: P201: OBTAIN SPECIAL INSTRUCTIONS BEFORE USE. P280: WEAR PROTECTIVE GLOVES. P305 + P351 + P338: IF IN EYES: RINSE CAUTIOUSLY WITH WATER FOR SEVERAL MINUTES. REMOVE CONTACT LENSES, IF PRESENT AND EASY TO DO. CONTINUE RINSING. P308 + P313: IF EXPOSED OR CONCERNED: GET MEDICAL ADVICE/ATTENTION.
ISSUE 1: NEW ISSUE CITY TECHNOLOGY ENGINEERING SAFETY DOC. REF. PSDS SENSORIC - HYDROUS.INDD ISSUE 1 ECN 150527C APRIL 2015 THE RIGHT SENSOR CAN SAVE A LIFE WEB: WWW.CITYTECH.COM EMAIL: SALES_EUROPE@CITYTECH.COM CALL: +49(0) 228 52 66 40 |