Common Name: METHANE 0.0001% TO 3.0% IN AIR
Manufacturer: NORLAB
SDS Revision Date: 5/15/2018
SDS Format: GHS-US
   
Item Number(s): 9JA87
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1 PRODUCT AND COMPANY IDENTIFICATION 
2 HAZARDS IDENTIFICATION 
3 COMPOSITION/INFORMATION ON INGREDIENTS 
4 FIRST AID MEASURES 
5 FIRE FIGHTING MEASURES 
6 ACCIDENTAL RELEASE MEASURES 
7 HANDLING AND STORAGE 
8 EXPOSURE CONTROLS/PERSONAL PROTECTION 
9 PHYSICAL AND CHEMICAL PROPERTIES 
10 STABILITY AND REACTIVITY 
11 TOXICOLOGICAL INFORMATION 
12 ECOLOGICAL INFORMATION 
13 DISPOSAL CONSIDERATIONS 
14 TRANSPORT INFORMATION 
15 REGULATORY INFORMATION 
16 OTHER INFORMATION 



NOR LAB
A DIVISION OF NORCO, INC.

SAFETY DATA SHEET

SDS

METHANE 0.0001% TO 3.0% IN AIR


1 PRODUCT AND COMPANY IDENTIFICATION 


PRODUCT IDENTIFIER: METHANE 0.0001% TO 3.0% IN AIR

SYNONYMS: METHANE IN AIR, CALIBRATION GAS

COMMON NAME: METHANE IN AIR

SDS NUMBER: NLB 2120

REVISION DATE: 5/15/2018

VERSION: 2

CAS NUMBER: NOT AVAILABLE - GAS MIXTURE

EPA NUMBER: NOT AVAILABLE

RCRA NUMBER: NOT APPLICABLE

CHEMICAL FAMILY: GAS MIXTURE

CHEMICAL FORMULA: CH4 IN AIR

PRODUCT USE: CALIBRATION OF ANALYITICAL INSTRUMENTATION

SUPPLIER DETAILS:
NORLAB A DIVISION OF NORCO
898 W. GOWEN RD.
BOISE, ID 83705

CONTACT: QUALITY DEPT.

PHONE: 208-336-1643

FAX: 208-433-6160

INTERNET: WWW.NORLAB-GAS.COM

FOR TRANSPORTATION EMERGENCY CONTACT CHEMTREC: 800-424-9300


2 HAZARDS IDENTIFICATION 


CLASSIFICATION OF SUBSTANCE:

GHS CLASSIFICATION IN ACCORDANCE WITH 29 CFR 1910 (OSHA HCS):
PHYSICAL, GASES UNDER PRESSURE, COMPRESSED GAS

GHS LABEL ELEMENTS, INCLUDING PRECAUTIONARY STATEMENTS:

GHS SIGNAL WORD: WARNING

GHS HAZARD PICTOGRAMS: GAS CYLINDER

GHS HAZARD STATEMENTS:
H280: CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED

CGA-HG24: SUPPORTS COMBUSTION.

GHS PRECAUTIONARY STATEMENTS:
P202:
DO NOT HANDLE UNTIL ALL SAFETY PRECAUTIONS HAVE BEEN READ AND UNDERSTOOD.

P260: DO NOT BREATHE GAS.

P403: STORE AND USE IN A WELL VENTILATED PLACE.

P309: IF EXPOSED OR IF YOU FEEL UNWELL

P340: REMOVE PERSON TO FRESH AIR AND KEEP COMFORTABLE FOR BREATHING.

CGA-PG02:
PROTECT FROM SUNLIGHT WHEN AMBIENT TEMPERATURE EXCEEDS 52 DEG. C
(125 DEG. F).

CGA-PG06: CLOSE VALVE AFTER EACH USE AND WHEN EMPTY.

CGA-PG10: USE ONLY WITH EQUIPMENT RATED FOR CYLINDER PRESSURE.

CGA-PG11:
NEVER PUT CYLINDERS INTO UNVENTILATED AREAS OF PASSENGER VEHICLES.

CGA-PG20: USE ONLY EQUIPMENT OF COMPATIBLE MATERIALS OF CONSTRUCTION.

CGA-PG05: USE A BACK FLOW PREVENTIVE DEVICE IN THE PIPING.

HAZARDS NOT OTHERWISE CLASSIFIED (HNOC) OR NOT COVERED BY GHS:

ROUTE OF ENTRY: SKIN; EYES; INHALATION

TARGET ORGANS: RESPIRATORY SYSTEM

INHALATION:
GAS MIXTURE CONTAINS SUFFICIENT OXYGEN TO SUPPORT LIFE. INHALATION OF HIGH
METHANE CONCENTRATIONS MAY CAUSE CENTRAL NERVOUS SYSTEM DEPRESSION WITH
DIZZINESS, DISORIENTATION, IN-COORDINATION, NAUSEA, AND NARCOSIS. HIGH
CONCENTRATIONS MAY ALSO CAUSE CARDIAC SENSITIZATION RESULTING IN IRREGULAR
HEARTBEAT AND MAY MAKE THE INDIVIDUAL MORE SUSCEPTIBLE TO CARDIAC EFFECTS
OF SUBSTANCES SUCH AS EPINEPHRINE AND ADRENALINE.

SKIN CONTACT:
CONTACT WITH RAPIDLY EXPANDING GAS NEAR THE POINT OF RELEASE MAY CAUSE
FROSTBITE WITH REDNESS, SKIN COLOR CHANGE TO GRAY OR WHITE, AND BLISTERING.

EYE CONTACT:
CONTACT WITH RAPIDLY EXPANDING GAS NEAR THE POINT OF RELEASE MAY CAUSE
FROSTBITE.

INGESTION: NOT ANTICIPATED. PRODUCT IS A GAS AT NORMAL CONDITIONS.


3 COMPOSITION/INFORMATION ON INGREDIENTS 


CHEMICAL INGREDIENTS:

CAS#               %                        CHEMICAL NAME

74-82-8             0.0001 - 3.0%           METHANE

7782-44-7             20.9%                 OXYGEN

7727-37-9             76.1 - 79.0999%       NITROGEN

AIR BALANCE = 20.9% OXYGEN IN NITROGEN


4 FIRST AID MEASURES 


INHALATION:
PROMPT MEDICAL ATTENTION IS MANDATORY IN ALL CASES OF OVEREXPOSURE TO
PRODUCT. RESCUE PERSONNEL SHOULD BE EQUIPPED WITH SELF-CONTAINED BREATHING
APPARATUS. CONSCIOUS PERSONS SHOULD BE ASSISTED TO AN UNCONTAMINATED AREA
AND INHALE FRESH AIR. QUICK REMOVAL FROM THE CONTAMINATED AREA IS MOST
IMPORTANT. UNCONSCIOUS PERSONS SHOULD BE MOVED TO AN UNCONTAMINATED AREA,
GIVEN ASSISTED (ARTIFICIAL) RESPIRATION AND SUPPLEMENTAL OXYGEN. FURTHER
TREATMENT SHOULD BE SYMPTOMATIC AND SUPPORTIVE.

SKIN CONTACT:
NONE REQUIRED FOR GAS. FOR FROSTBITE, IMMERSE SKIN IN LUKEWARM WATER. DO
NOT USE HOT WATER. OBTAIN MEDICAL ATTENTION.

EYE CONTACT:
NONE REQUIRED FOR GAS. IF FROSTBITE IS SUSPECTED, FLUSH EYES WITH COOL
WATER FOR 15 MINUTES AND OBTAIN IMMEDIATE MEDICAL ATTENTION.

INGESTION: NOT A DIRECT HAZARD.


5 FIRE FIGHTING MEASURES 


FLAMMABILITY: NOT FLAMMABLE

FLASH POINT: NONE
FLASH POINT METHOD: NOT APPLICABLE

AUTOIGNITION TEMPERATURE: NONE

LOWER EXPLOSIVE LIMIT: 5.0% (METHANE)
UPPER EXPLOSIVE LIMIT: 15.0% (METHANE)

FIRE AND EXPLOSION HAZARDS:
NONFLAMMABLE. CYLINDERS MAY RUPTURE VIOLENTLY OR VENT RAPIDLY FROM PRESSURE
WHEN INVOLVED IN A FIRE SITUATION.

EXTINGUISHING MEDIA:
NONE REQUIRED. USE AS APPROPRIATE FOR SURROUNDING MATERIALS

FIRE FIGHTING INSTRUCTIONS:
USE WATER SPRAY TO COOL ADJACENT CYLINDERS AND AREAS. FIREFIGHTERS SHOULD
WEAR RESPIRATORY PROTECTION (SCBA) AND FULL TURNOUT OR BUNKER GEAR.
CONTINUE TO COOL FIRE-EXPOSED CYLINDERS UNTIL WELL AFTER FLAMES ARE
EXTINGUISHED.


6 ACCIDENTAL RELEASE MEASURES 


EVACUATE ALL PERSONNEL FROM AFFECTED AREA. USE APPROPRIATE PROTECTIVE
EQUIPMENT. IF LEAK IS IN USER'S EQUIPMENT, BE CERTAIN TO PURGE PIPING WITH
INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN CONTAINER OR VALVE,
CONTACT THE APPROPRIATE EMERGENCY TELEPHONE NUMBER LISTED IN SECTION 1, OR
CALL YOUR CLOSEST NORCO/NORLAB LOCATION.


7 HANDLING AND STORAGE 


HANDLING PRECAUTIONS:
USE ONLY IN WELL-VENTILATED AREAS. VALVE PROTECTION CAPS MUST REMAIN IN
PLACE UNLESS THE CYLINDER IS SECURED WITH VALVE OUTLET PIPED TO USE POINT.
DO NOT DRAG, SLIDE OR ROLL CYLINDERS. USE A SUITABLE HAND TRUCK FOR
CYLINDER MOVEMENT. USE A PRESSURE REGULATOR WHEN CONNECTING CYLINDER TO
LOWER PRESSURE (<3000 PSIG) PIPING OR SYSTEMS. DO NOT HEAT CYLINDER BY ANY
MEANS TO INCREASE THE DISCHARGE RATE OF PRODUCT FROM THE CYLINDER. USE A
CHECK VALVE OR TRAP IN THE DISCHARGE LINE TO PREVENT HAZARDOUS BACKFLOW
INTO THE CYLINDER.

FOR ADDITIONAL RECOMMENDATIONS, CONSULT COMPRESSED GAS ASSOCIATION
PAMPHLETS P-1.

NEVER CARRY A COMPRESSED GAS CYLINDER OR A CONTAINER OF A GAS IN CRYOGENIC
LIQUID FROM IN AN ENCLOSED SPACE SUCH AS A CAR TRUNK, VAN OR STATION WAGON.

STORAGE REQUIREMENTS:
PROTECT CYLINDERS FROM PHYSICAL DAMAGE. STORE IN COOL, DRY, WELL-VENTILATED
AREA AWAY FROM HEAVY TRAFFIC AREAS AND EMERGENCY EXITS. DO NOT ALLOW THE
TEMPERATURE WHERE CYLINDERS ARE STORED TO EXCEED 125 DEGREES F
(52 DEGREES C). CYLINDERS SHOULD BE STORED UPRIGHT AND FIRMLY SECURED TO
PREVENT FALLING OR BEING KNOCKED OVER. FULL AND EMPTY CYLINDERS SHOULD BE
SEGREGATED. USE A "FIRST IN-FIRST OUT" INVENTORY SYSTEM TO PREVENT FULL
CYLINDERS FROM BEING STORED FOR EXCESSIVE PERIODS OF TIME.


8 EXPOSURE CONTROLS/PERSONAL PROTECTION 


ENGINEERING CONTROLS:
LOCAL EXHAUST VENTILATION AS NECESSARY TO LIMIT EXPOSURE BELOW THE
ACCEPTABLE EXPOSURE LIMITS.

PERSONAL PROTECTIVE EQUIPMENT:

METHANE:
CAS#: (74-82-8) [0.0001-3.0%]

OXYGEN:
CAS#: (7782-44-7) [20.9%]

NITROGEN:
CAS#: (7727-37-9) [76.1-79.0999%]

PERSONAL PROTECTIVE EQUIPMENT:

RESPIRATORY PROTECTION:
WHERE RISK ASSESSMENT SHOWS AIR-PURIFYING RESPIRATORS ARE APPROPRIATE USE
A FULL-FACE RESPIRATOR WITH MULTI-PURPOSE COMBINATION (US) OR TYPE AXBEK
(EN 14387) RESPIRATOR CARTRIDGES AS A BACKUP TO ENGINEERING CONTROLS. IF
THE RESPIRATOR IS THE SOLE MEANS OF PROTECTION, USE A FULL-FACE SUPPLIED
AIR RESPIRATOR. USE RESPIRATORS AND COMPONENTS TESTED AND APPROVED UNDER
APPROPRIATE GOVERNMENT STANDARDS SUCH AS NIOSH (US) OR CEN (EU).

HAND PROTECTION:
HANDLE WITH GLOVES. GLOVES MUST BE INSPECTED PRIOR TO USE. USE PROPER GLOVE
REMOVAL TECHNIQUE (WITHOUT TOUCHING GLOVES OUTER SURFACE) TO AVOID SKIN
CONTACT WITH THIS PRODUCT. DISPOSE OF CONTAMINATED GLOVES AFTER USE IN
ACCORDANCE WITH APPLICABLE LAWS AND GOOD LABORATORY PRACTICES. WASH AND
DRY HANDS.

FULL CONTACT MATERIAL:
FLUORINATED RUBBER MINIMUM LAYER THICKNESS: 0.7 MM
BREAK THROUGH TIME: 480 MIN
MATERIAL TESTED: VITOJECT (KCL 890 / ALDRICH Z677698, SIZE M)

SPLASH PROTECTION:

MATERIAL:
NITRILE RUBBER MINIMUM LAYER THICKNESS: 0.4 MM
BREAK THROUGH TIME: 60 MIN
MATERIAL TESTED: CAMATRIL (KCL 730 / ALDRICH Z677442, SIZE M)

DATA SOURCE:
KCL GMBH, D-36124 EICHENZELL, PHONE +49 (0)6659 87300, E-MAIL SALES@KCL.DE,

TEST METHOD:
EN374 IF USED IN SOLUTION, OR MIXED WITH OTHER SUBSTANCES, AND UNDER
CONDITIONS WHICH DIFFER FROM EN 374, CONTACT THE SUPPLIER OF THE CE
APPROVED GLOVES. THIS RECOMMENDATION IS ADVISORY ONLY AND MUST BE EVALUATED
BY AN INDUSTRIAL HYGIENIST FAMILIAR WITH THE SPECIFIC SITUATION OF
ANTICIPATED USE BY OUR CUSTOMERS. IT SHOULD NOT BE CONSTRUED AS OFFERING
AN APPROVAL FOR ANY SPECIFIC USE SCENARIO.

EYE PROTECTION:
USE EQUIPMENT FOR EYE PROTECTION TESTED AND APPROVED UNDER APPROPRIATE
GOVERNMENT STANDARDS SUCH AS NIOSH (US) OR EN 166(EU).

SKIN AND BODY PROTECTION:
IMPERVIOUS CLOTHING, THE TYPE OF PROTECTIVE EQUIPMENT MUST BE SELECTED
ACCORDING TO THE CONCENTRATION AND AMOUNT OF THE DANGEROUS SUBSTANCE AT
THE SPECIFIC WORKPLACE.

HYGIENE MEASURES: GENERAL INDUSTRIAL HYGIENE PRACTICE.

METHANE:
CAS#: (74-82-8) [0.0001-3.0%]

COMPONENTS WITH WORKPLACE CONTROL PARAMETERS:
TWA: 1,000 PPM USA. ACGIH THRESHOLD LIMIT VALUES (TLV)

CENTRAL NERVOUS SYSTEM IMPAIRMENT CARDIAC SENSITIZATION:

OXYGEN:
CAS#: (7782-44-7) [20.9%]

NITROGEN:
CAS#: (7727-37-9) [76.1-79.0999%]


9 PHYSICAL AND CHEMICAL PROPERTIES 


APPEARANCE: COLORLESS GAS

PHYSICAL STATE: GAS

ODOR: ODORLESS

ODOR THRESHOLD: NOT AVAILABLE

MOLECULAR FORMULA: CH4 IN AIR

SPECIFIC GRAVITY OR DENSITY: NOT AVAILABLE

SOLUBILITY: NEGLIGIBLE

BOILING POINT: NOT DETERMINED

PERCENT VOLATILE: 100%

FLAMMABILITY: NOT FLAMMABLE

FREEZING OR MELTING POINT: NOT DETERMINED

FLASH POINT: NOT DETERMINED

UPPER FLAMMABILITY LIMIT AND LOWER FLAMMABILITY LIMIT:
15.0% / 5.0% (METHANE)


10 STABILITY AND REACTIVITY 


CHEMICAL STABILITY: STABLE

CONDITIONS TO AVOID IDENTIFICATION: NONE KNOWN

MATERIALS TO AVOID IDENTIFICATION: NONE

HAZARDOUS DECOMPOSITION:
COMBUSTION WILL PRODUCE CARBON DIOXIDE AND, POSSIBLY TOXIC CHEMICALS SUCH
AS CARBON MONOXIDE.

HAZARDOUS POLYMERIZATION: WILL NOT OCCUR.


11 TOXICOLOGICAL INFORMATION 


METHANE:
CAS#: (74-82-8) [0.0001-3.0%]

INFORMATION ON TOXICOLOGICAL EFFECTS:

ACUTE TOXICITY:
ORAL LD50: NO DATA AVAILABLE
INHALATION LC50:
DERMAL LD50:

OTHER INFORMATION ON ACUTE TOXICITY:
SKIN CORROSION/IRRITATION: NO DATA AVAILABLE
SERIOUS EYE DAMAGE/EYE IRRITATION: NO DATA AVAILABLE
RESPIRATORY OR SKIN SENSITIZATION: NO DATA AVAILABLE
GERM CELL MUTAGENICITY: NO DATA AVAILABLE

CARCINOGENICITY:

IARC:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS PROBABLE, POSSIBLE OR CONFIRMED HUMAN CARCINOGEN BY
IARC.

ACGIH:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY ACGIH.

NTP:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A KNOWN OR ANTICIPATED CARCINOGEN BY NTP.

OSHA:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY OSHA.

REPRODUCTIVE TOXICITY: NO DATA AVAILABLE

TERATOGENICITY: NO DATA AVAILABLE

SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE (GLOBALLY HARMONIZED
SYSTEM): NO DATA AVAILABLE

SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE (GLOBALLY HARMONIZED
SYSTEM): NO DATA AVAILABLE

ASPIRATION HAZARD: NO DATA AVAILABLE

POTENTIAL HEALTH EFFECTS:
INHALATION MAY BE HARMFUL IF INHALED. MAY CAUSE RESPIRATORY TRACT
IRRITATION. INGESTION MAY BE HARMFUL IF SWALLOWED. SKIN MAY BE HARMFUL
IF ABSORBED THROUGH SKIN. MAY CAUSE SKIN IRRITATION. EYES MAY CAUSE EYE
IRRITATION.

SIGNS AND SYMPTOMS OF EXPOSURE:
TO THE BEST OF OUR KNOWLEDGE, THE CHEMICAL, PHYSICAL, AND TOXICOLOGICAL
PROPERTIES HAVE NOT BEEN THOROUGHLY INVESTIGATED.

SYNERGISTIC EFFECTS: NO DATA AVAILABLE

ADDITIONAL INFORMATION:
RTECS: PA1490000

OXYGEN:
CAS#: (7782-44-7) [20.9%]

INFORMATION ON TOXICOLOGICAL EFFECTS:

ACUTE TOXICITY:
ORAL LD50: NO DATA AVAILABLE
INHALATION LC50:
DERMAL LD50:

OTHER INFORMATION ON ACUTE TOXICITY:
SKIN CORROSION/IRRITATION: NO DATA AVAILABLE
SERIOUS EYE DAMAGE/EYE IRRITATION: NO DATA AVAILABLE
RESPIRATORY OR SKIN SENSITIZATION: NO DATA AVAILABLE
GERM CELL MUTAGENICITY: NO DATA AVAILABLE

CARCINOGENICITY:

IARC:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS PROBABLE, POSSIBLE OR CONFIRMED HUMAN CARCINOGEN
BY IARC.

ACGIH:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY ACGIH.

NTP:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A KNOWN OR ANTICIPATED CARCINOGEN BY NTP.

OSHA:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY OSHA.

REPRODUCTIVE TOXICITY: NO DATA AVAILABLE

TERATOGENICITY: NO DATA AVAILABLE

SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE (GLOBALLY HARMONIZED
SYSTEM): NO DATA AVAILABLE

SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE (GLOBALLY HARMONIZED
SYSTEM): NO DATA AVAILABLE

ASPIRATION HAZARD: NO DATA AVAILABLE

POTENTIAL HEALTH EFFECTS:
INHALATION MAY BE HARMFUL IF INHALED. MAY CAUSE RESPIRATORY TRACT
IRRITATION. INGESTION MAY BE HARMFUL IF SWALLOWED. SKIN MAY BE HARMFUL
IF ABSORBED THROUGH SKIN. MAY CAUSE SKIN IRRITATION. EYES MAY CAUSE EYE
IRRITATION.

SIGNS AND SYMPTOMS OF EXPOSURE:
NAUSEA, DIZZINESS, UNCONSCIOUSNESS, MAY BE HARMFUL.

SYNERGISTIC EFFECTS: NO DATA AVAILABLE

ADDITIONAL INFORMATION:
RTECS: RS2060000

NITROGEN:
CAS#: (7727-37-9) [76.1-79.0999%]

INFORMATION ON TOXICOLOGICAL EFFECTS:

ACUTE TOXICITY:
ORAL LD50: NO DATA AVAILABLE
INHALATION LC50:
DERMAL LD50:

OTHER INFORMATION ON ACUTE TOXICITY:
SKIN CORROSION/IRRITATION: NO DATA AVAILABLE
SERIOUS EYE DAMAGE/EYE IRRITATION: NO DATA AVAILABLE
RESPIRATORY OR SKIN SENSITIZATION: NO DATA AVAILABLE
GERM CELL MUTAGENICITY: NO DATA AVAILABLE

CARCINOGENICITY:

IARC:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS PROBABLE, POSSIBLE OR CONFIRMED HUMAN CARCINOGEN
BY IARC.

ACGIH:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY ACGIH.

NTP:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A KNOWN OR ANTICIPATED CARCINOGEN BY NTP.

OSHA:
NO COMPONENT OF THIS PRODUCT PRESENT AT LEVELS GREATER THAN OR EQUAL TO
0.1% IS IDENTIFIED AS A CARCINOGEN OR POTENTIAL CARCINOGEN BY OSHA.

REPRODUCTIVE TOXICITY: NO DATA AVAILABLE

TERATOGENICITY: NO DATA AVAILABLE

SPECIFIC TARGET ORGAN TOXICITY - SINGLE EXPOSURE (GLOBALLY HARMONIZED
SYSTEM): NO DATA AVAILABLE

SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE (GLOBALLY HARMONIZED
SYSTEM): NO DATA AVAILABLE

ASPIRATION HAZARD: NO DATA AVAILABLE

POTENTIAL HEALTH EFFECTS:
INHALATION MAY BE HARMFUL IF INHALED. MAY CAUSE RESPIRATORY TRACT
IRRITATION. INGESTION MAY BE HARMFUL IF SWALLOWED. SKIN MAY BE HARMFUL
IF ABSORBED THROUGH SKIN. MAY CAUSE SKIN IRRITATION. EYES MAY CAUSE EYE
IRRITATION.

SIGNS AND SYMPTOMS OF EXPOSURE: MAY BE HARMFUL., NAUSEA, HEADACHE, VOMITING

SYNERGISTIC EFFECTS: NO DATA AVAILABLE

ADDITIONAL INFORMATION:
RTECS: QW9700000


12 ECOLOGICAL INFORMATION 


METHANE:
CAS#: (74-82-8) [0.0001-3.0%]

INFORMATION ON ECOLOGICAL EFFECTS:

TOXICITY: NO DATA AVAILABLE

PERSISTENCE AND DEGRADABILITY: NO DATA AVAILABLE

BIOACCUMULATIVE POTENTIAL: NO DATA AVAILABLE

MOBILITY IN SOIL: NO DATA AVAILABLE

PBT AND VPVB ASSESSMENT: NO DATA AVAILABLE

OTHER ADVERSE EFFECTS: NO DATA AVAILABLE

OXYGEN:
CAS#: (7782-44-7) [20.9%]

INFORMATION ON ECOLOGICAL EFFECTS:

TOXICITY: NO DATA AVAILABLE

PERSISTENCE AND DEGRADABILITY: NO DATA AVAILABLE

BIOACCUMULATIVE POTENTIAL: NO DATA AVAILABLE

MOBILITY IN SOIL: NO DATA AVAILABLE

PBT AND VPVB ASSESSMENT: NO DATA AVAILABLE

OTHER ADVERSE EFFECTS: NO DATA AVAILABLE

NITROGEN:
CAS#: (7727-37-9) [76.1-79.0999%]

INFORMATION ON ECOLOGICAL EFFECTS:

TOXICITY: NO DATA AVAILABLE

PERSISTENCE AND DEGRADABILITY: NO DATA AVAILABLE

BIOACCUMULATIVE POTENTIAL: NO DATA AVAILABLE

MOBILITY IN SOIL: NO DATA AVAILABLE

PBT AND VPVB ASSESSMENT: NO DATA AVAILABLE

OTHER ADVERSE EFFECTS: NO DATA AVAILABLE


13 DISPOSAL CONSIDERATIONS 


DISPOSE OF IN ACCORDANCE WITH LOCAL REGULATIONS. DO NOT ATTEMPT TO DISPOSE
OF WASTE OR UNUSED QUANTITIES IN RETURNABLE CYLINDERS. RETURN IN THE
SHIPPING CONTAINER, PROPERLY LABELED, WITH ANY VALVE OUTLET PLUGS OR CAPS
SECURE AND VALVE PROTECTION CAP IN PLACE TO NORLAB FOR PROPER DISPOSAL.
NON-REFILLABLE CONTAINERS SHOULD BE VENTED IN A WELL-VENTILATED AREA THEN
DISPOSED OF IN COMPLIANCE WITH LOCAL REGULATIONS, OR RETURNED TO NORLAB.


14 TRANSPORT INFORMATION 


UN1956, COMPRESSED GAS, N.O.S., 2.2

PROPER SHIPPING NAME US:
UN 1956, COMPRESSED GAS N.O.S., (METHANE, AIR), 2.2

PROPER SHIPPING NAME CANADA:
UN1956, COMPRESSED GAS, N.O.S., (METHANE, AIR), 2.2

CLASS 2.2, NON-FLAMMABLE AND NON-TOXIC GASES


15 REGULATORY INFORMATION 


COMPONENT     (CAS#)         [%]                CODES

METHANE         (74-82-8)    [0.0001-3.0%]      MASS, NJHS, PA, TSCA, TXAIR

OXYGEN        (7782-44-7)    [20.9%]            MASS, PA, TSCA

NITROGEN      (7727-37-9)    [76.1-79.0999%]    MASS, PA, TSCA

REGULATORY CODE DESCRIPTIONS:
MASS = MA MASSACHUSETTS HAZARDOUS SUBSTANCES LIST
NJHS = NJ RIGHT-TO-KNOW HAZARDOUS SUBSTANCES
PA = PA RIGHT-TO-KNOW LIST OF HAZARDOUS SUBSTANCES
TSCA = TOXIC SUBSTANCES CONTROL ACT
TXAIR = TX AIR CONTAMINANTS WITH HEALTH EFFECTS SCREENING LEVEL


16 OTHER INFORMATION 


NFPA:
HEALTH          0
FIRE            0
REACTIVITY      0
SPECIFIC HAZARD N/A

HMIS III:
HEALTH          0
FIRE            0
PHYSICAL HAZARD 3
HMIS PPE        B - SAFETY GLASSES, GLOVES

NFPA:
HEALTH          0
FIRE HAZARD     0
REACTIVITY      0
SPECIFIC HAZARD

HMIS:
HEALTH              0
FLAMMABILITY        0
PHYSICAL HAZARD     3
PERSONAL PROTECTION B

PPE:
CHEMICAL GOGGLES
GLOVES

DISCLAIMER:
ALTHOUGH REASONABLE CARE HAS BEEN TAKEN IN THE PREPARATION OF THIS
DOCUMENT, WE EXTEND NO WARRANTIES AND MAKE NO REPRESENTATIONS AS TO THE
ACCURACY OR COMPLETENESS OF THE INFORMATION CONTAINED HEREIN, AND ASSUME
NO RESPONSIBILITY REGARDING THE SUITABILITY OF THIS INFORMATION FOR THE
USER'S INTENDED PURPOSES OR FOR THE CONSEQUENCES OF ITS USE. EACH
INDIVIDUAL SHOULD MAKE A DETERMINATION AS TO THE SUITABILITY OF THE
INFORMATION FOR THEIR PARTICULAR PURPOSE(S).

REVISION DATE: 5/15/2018