Common Name: MAINTENANCE-FREE SEALED PURE-LEADS
Manufacturer: DUAL-LITE
SDS Revision Date: 1/31/1996
SDS Format: No Format Specified
   
Item Number(s): 006008, 2089050, 2089068, 2394021, 3UVZ1, 3UVZ6, 3WDL5, 4018651, 4508453, 4HX25, 8A869, 8CL38, 9RPV1
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION I 
SECTION II - HAZARDOUS INGREDIENTS/IDENTITY INFORMATION 
SECTION III - PHYSICAL/CHEMICAL CHARACTERISTICS 
SECTION IV - FIRE AND EXPLOSION HAZARD DATA 
SECTION V - REACTIVITY DATA 
SECTION VI - HEALTH HAZARD DATA 
SECTION VII - PRECAUTIONS FOR SAFE HANDLING AND USE 
SECTION VIII - CONTROL MEASURES 
SECTION IX - TRANSPORTATION 
SECTION X - ADDITIONAL INFORMATION 



DUAL LITE

MAINTENANCE-FREE SEALED PURE-LEADS

MATERIAL SAFETY DATA SHEET

IDENTITY (AS USED ON LABEL AND LIST):

NOTE:
BLANK SPACES ARE NOT PERMITTED. IF ANY ITEM IS NOT APPLICABLE, OR NO
INFORMATION IS AVAILABLE, THE SPACE MUST BE MARKED TO INDICATE THAT.


SECTION I 


BATTERY MANUFACTURER'S MSDS DISTRIBUTED BY: DUAL-LITE

MSDS #1

EMERGENCY TELEPHONE NUMBER: NOT APPLICABLE

TELEPHONE NUMBER FOR INFORMATION: NOT APPLICABLE

DATE PREPARED: JAN. 31, 1996

SIGNATURE OF PREPARER (OPTIONAL):


SECTION II - HAZARDOUS INGREDIENTS/IDENTITY INFORMATION 


HAZARDOUS COMPONENTS               OSHA  ACGIH   OTHER LIMITS     %
(SPECIFIC CHEMICAL                 PEL   TLV     RECOMMENDED     (OPTIONAL)
IDENTITY: COMMON NAME(S))

LEAD-LEAD OXIDES                                 50 (MICRO)G/M3   56-67%

SULFURIC ACID ELECTROLYTE                        1.0 MG/M3        6-8%

NON-HAZARDOUS MATERIALS                                          26-37%


SECTION III - PHYSICAL/CHEMICAL CHARACTERISTICS 


BOILING POINT: N/A

SPECIFIC GRAVITY (H2O = 1): N/A

VAPOR PRESSURE (MMHg.): N/A

MELTING POINT: N/A

VAPOR DENSITY (AIR = 1): N/A

EVAPORATION RATE BUTYL ACETATE = 1: N/A

SOLUBILITY IN WATER: N/A

APPEARANCE AND ODOR: N/A


SECTION IV - FIRE AND EXPLOSION HAZARD DATA 


FLASH POINT (METHOD USED): NON-FLAMMABLE

FLAMMABLE LIMITS: N/A
LEL:
UEL:

EXTINGUISHING MEDIA: MULTI-PURPOSE DRY CHEMICAL OR MULTI-PURPOSE CO2.

SPECIAL FIRE FIGHTING PROCEDURES:
COOL BATTERY EXTERIOR TO PREVENT RUPTURE. ACID MISTS AND VAPORS IN A FIRE
ARE TOXIC AND CORROSIVE.

UNUSUAL FIRE AND EXPLOSION HAZARDS:
HYDROGEN GAS MAY BE PRODUCED AND MAY EXPLODE IF IGNITED. REMOVE ALL SOURCES
OF IGNITION. VENTILATE AREA.


SECTION V - REACTIVITY DATA 


STABILITY:
UNSTABLE (  )
STABLE   (XX)

CONDITIONS TO AVOID: AVOID SHORTING. USE ONLY APPROVED CHARGING METHODS.

INCOMPATIBILITY (MATERIALS TO AVOID):
SOLVENTS MAY DISSOLVE BATTERY CAUSE MATERIAL.

HAZARDOUS DECOMPOSITION OR BY-PRODUCTS: HYDROGEN GAS

HAZARDOUS POLYMERIZATION:
MAY OCCUR      (  )
WILL NOT OCCUR (XX)

CONDITIONS TO AVOID:
AVOID TEMPERATURE EXTREMES ABOVE 80 DEG. C AND BELOW 40 DEG. C. DO NOT
PUNCTURE BATTERY CASE.


SECTION VI - HEALTH HAZARD DATA 


ROUTE(S) OF ENTRY:
EYES        (  )
INHALATION? (  )
SKIN?       (XX)
INGESTION?  (XX)

HEALTH HAZARDS (ACUTE AND CHRONIC):
SEVERE BURNS AND EYE DAMAGE FROM SULFURIC ACID ELECTROLYTE. ILLNESS FROM
SULFUR OXIDE FUMES.

CARCINOGENICITY: N/A
NTP?:
IARC MONOGRAPHS?:
OSHA REGULATED?:

SIGNS AND SYMPTOMS OF EXPOSURE:
IRRITATION AND ACID BURNS. PUNGENT ODOR AND RESPIRATORY IRRITATION.

MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: N/A

EMERGENCY AND FIRST AID PROCEDURES:
FOR SULFUR OXIDE FUMES, DISCONNECT BATTERIES, EVACUATE AND VENTILATE.
EXTERNAL, FLUSH AREAS CONTAMINATED BY SULFURIC ACID ELECTROLYTE WITH WATER.
INTERNAL, DRINK LARGE QUANTITIES OF WATER OR MILK, FOLLOWED BY MILK OF
MAGNESIA, BEATEN EGGS OR VEGETABLE OIL.


SECTION VII - PRECAUTIONS FOR SAFE HANDLING AND USE 


STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED:
AVOID CONTACT WITH SULFURIC ACID ELECTROLYTE FROM BATTERY. FLUSH WITH WATER.

WASTE DISPOSAL METHOD:
NEUTRALIZE WITH SOLUTION OF BAKING SODA IN WATER. DISPOSE WITH AUTOMOTIVE
BATTERY SCRAP.

PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING:
BATTERIES WITH RELEASED ELECTROLYTE SHALL BE SEALED IN POLYETHYLENE BAGS.

OTHER PRECAUTIONS:
DO NOT CRACK BATTERY CASES. DO NOT OVERCHARGE. KEEP LIGHTED CIGARETTES,
SPARKS, AND FLAMES AWAY FROM CHARGING BATTERIES.


SECTION VIII - CONTROL MEASURES 


RESPIRATORY PROTECTION (SPECIFY TYPE): N/A

VENTILATION:
LOCAL EXHAUST:
MECHANICAL (GENERAL):
SPECIAL:
OTHER: NATURAL CONVECTION

PROTECTIVE GLOVES: USE RUBBER GLOVES IF CASE IS CRACKED

EYE PROTECTION: RECOMMENDED

OTHER PROTECTIVE CLOTHING OR EQUIPMENT: N/A

WORK/HYGIENIC PRACTICES: N/A


SECTION IX - TRANSPORTATION 


"PURE-LEAD" BATTERIES ARE STARVED ELECTROLYTE BATTERIES WHICH MEANS THE
ELECTROLYTE IS ABSORBED IN THE SEPARATOR MATERIAL. THE BATTERIES ARE ALSO
SEALED. AS OF SEPTEMBER 30, 1995, SEALED "PURE-LEAD" BATTERIES WERE
CLASSIFIED AS "NONSPILLABLE BATTERIES", AND AS SUCH ARE NOT SUBJECT TO THE
FULL REQUIREMENTS OF 49 CFR SUBSECTION 173.159. THE PREVIOUS EXEMPT
CLASSIFICATION. "DRY BATTERIES, NOT RESTRICTED" WAS DISCONTINUED EFFECTIVE
SEPTEMBER 30, 1995. "NONSPILLABLE" BATTERIES ARE EXCEPTED FROM THE
REGULATION'S COMPREHENSIVE PACKAGING REQUIREMENTS IF THE FOLLOWING
CONDITIONS ARE SATISFIED:
(1) THE BATTERY IS PROTECTED AGAINST SHORT CIRCUITS AND IS SECURELY
PACKAGED.
(2) FOR BATTERIES MANUFACTURED AFTER SEPTEMBER 30, 1995, THE BATTERY AND
OUTER PACKAGING MUST BE PLAINLY AND DURABLY MARKED "NONSPILLABLE" OR
"NONSPILLABLE BATTERY" AND
(3) THE BATTERY IS CAPABLE OF WITHSTANDING VIBRATION AND PRESSURE
DIFFERENTIAL TESTS SPECIFIED IN 49 CFR SUBSECTION 173.159(D).

SEALED "PURE-LEAD" BATTERIES HAVE BEEN TESTED BY WYLE SCIENTIFIC SERVICES &
SYSTEMS LABORATORIES GROUP AND DETERMINED TO BE IN COMPLIANCE WITH THE
VIBRATION AND PRESSURE DIFFERENTIAL TESTS CONTAINED IN 49 CFR SUBSECTION
173.159(D), AND THEREFORE AS OF SEPTEMBER 30, 1995, EXCEPTED FROM THE DOT
REQUIREMENTS SET FORTH IN 49 CFR SUBSECTION 173.159, OTHER THAN PARAGRAPH
(D).

BATTERY SHIPMENTS FROM ALL LOCATIONS, WILL BE PROPERLY LABELED IN ACCORDANCE
WITH APPLICABLE DOT REGULATIONS. PACKAGING CHANGES PERFORMED AT OTHER
LOCATIONS MAY REQUIRE ADDITIONAL LABELING, SINCE IN ADDITION TO THE BATTERY
ITSELF CONTAINING THE REQUIRED MARKING, THE OUTER PACKAGING OF THE BATTERY
MUST ALSO CONTAIN THE REQUIRED MARKING: "NONSPILLABLE" OR "NONSPILLABLE
BATTERY". BECAUSE THE BATTERIES ARE CLASSIFIED AS "NONSPILLABLE" AND MEET
THE THREE CONDITIONS ABOVE, (FROM SUBSECTION 173.159 (D)) THEY DO NOT HAVE
AN ASSIGNED UN NUMBER NOR DO THEY REQUIRE ADDITIONAL DOT HAZARD LABELING.

THE REGULATION CHANGE EFFECTIVE SEPTEMBER, 1995, WAS TO CLARIFY AND
DISTINGUISH TO SHIPPERS AND TRANSPORTERS, ALL BATTERIES THAT HAVE BEEN
TESTED AND DETERMINED TO BE IN COMPLIANCE WITH THE DOT HAZARDOUS MATERIAL
REGULATIONS, THE INTERNATIONAL CIVIL AERONAUTICS ORGANIZATION (ICAO), AND
THE INTERNATIONAL AIR TRANSPORT ASSOCIATION (IATA) PACKING INSTRUCTION
806 AND SPECIAL PROVISION A67, AND THEREFORE EXCEPTED FROM ALL OTHER
REQUIREMENTS OF THE REGULATIONS AND CLASSIFIED AS A "NONSPILLABLE BATTERY".


SECTION X - ADDITIONAL INFORMATION 


THE SEALED LEAD ACID BATTERY IS DETERMINED TO BE AN "ARTICLE" ACCORDING TO
THE OSHA HAZARD COMMUNICATION STANDARD AND IS THEREBY EXCLUDED FROM ANY
REQUIREMENTS OF THE STANDARD. THE MATERIAL SAFETY DATA SHEET IS THEREFORE
SUPPLIED FOR INFORMATIONAL PURPOSES ONLY.

THE INFORMATION AND RECOMMENDATIONS CONTAINED HEREIN HAVE BEEN COMPLIED FROM
SOURCES BELIEVED TO BE RELIABLE AND REPRESENT CURRENT OPINION ON THE
SUBJECT. NO WARRANTY, GUARANTEE, OR REPRESENTATION IS MADE AS TO THE
ABSOLUTE CORRECTNESS OR SUFFICIENCY OF ANY REPRESENTATION CONTAINED HEREIN
AND THE MANUFACTURER ASSUMES NO RESPONSIBILITY IN CONNECTION THEREWITH, NOR
CAN IT BE ASSUMED THAT ALL ACCEPTABLE SAFETY MEASURES ARE CONTAINED HEREIN,
OR THAT ADDITIONAL MEASURES MAY NOT BE REQUIRED UNDER PARTICULAR OR
EXCEPTIONAL CONDITIONS OR CIRCUMSTANCES.

N/A OR NOT APPLICABLE - NOT APPLICABLE FOR FINISHED PRODUCT USED IN NORMAL
CONDITIONS.

(REPRODUCE LOCALLY)