SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. DIVERSITECH MATERIAL SAFETY DATA SHEET SCM-707-GRAN TRIPLE "D" GRANULAR UNIVERSAL COIL CLEANER MSDS #: SCM-707-GRAN JANUARY 2008
MANUFACTURED BY: SPECIALTY CHEMICAL MANUFACTURING A DIVERSITECH COMPANY 1633-B HIGH BRIDGE ROAD QUINCY, FL 32351 EMERGENCY PHONE NO.: 1+800.255.3924 CHEM-TEL (CHEMICAL EMERGENCIES ONLY) PHONE NUMBER FOR INFORMATION: 850-875-1716 FAX: 850-627-2699 DATE REVISED: JANUARY 2008 NAME OF PREPARER: ANTHONY JERNIGAN
INGREDIENT CAS NO OSHA ACIGH OTHER % OR PEL TLV STEL RANGE SODIUM METASILICATE 6834-92-0 2 MG/M3 (FOR DUST) 20-40 POTASSIUM CARBONATE 584-08-7 NOT ESTABLISHED 20-40
ROUTES OF ENTRY: INHALATION: YES SKIN: NO INGESTION: YES EYES: YES HEALTH HAZARDS (ACUTE AND CHRONIC): GRAN-UNIV IS MODERATELY TOXIC IF INGESTED. EYE CONTACT CAUSES EXTREME IRRITATION. PROLONGED CONTACT MAY CAUSE SKIN IRRITATION, DRYING AND DERMATITIS. CARCINOGENICITY: NTP: NO IARC MONOGRAPHS: NO OSHA REGULATED: NO SIGNS AND SYMPTOMS OF EXPOSURE: INHALATION: DUST MAY CAUSE CHEMICAL PNEUMONITIS. THIS PRODUCT IS NOT TOXIC BY INHALATION. SKIN: IRRITANT. PROLONGED CONTACT MAY CAUSE DERMATITIS OR DRYING OF SKIN. INGESTION: DO NOT TAKE INTERNALLY. IF INGESTED, IT MAY DAMAGE THROAT AND DIGESTIVE TISSUE. SWALLOWING MAY CAUSE DIARRHEA, NAUSEA, VOMITING OR UNCONSCIOUSNESS EYES: MAY CAUSE SEVERE EYE IRRITATION, PERMANENT DAMAGE OR BLINDNESS. MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE: CONTACT WITH SKIN OR EYES, OR BREATHING DUST CAN CAUSE EYE SKIN OR TISSUE DAMAGE OR AFFECT INDIVIDUALS WITH RESPIRATORY DISORDERS.
EYES: FLUSH WITH WATER FOR 15 MINUTES. CONSULT A PHYSICIAN IF IRRITATION PERSISTS SKIN: REMOVE CONTAMINATED CLOTHING. WASH THE AFFECTED AREA WITH SOAP AND WATER. LAUNDER OR DRY CLEAN CLOTHES BEFORE REUSE. INHALATION: EVACUATE TO A SAFE AREA WITH PLENTY OF FRESH AIR. ALLOW THE AFFECTED INDIVIDUAL TO REST IN A WELL VENTILATED AREA, THEN SEEK MEDICAL AID IMMEDIATELY. INGESTION: DO NOT INDUCE VOMITING. FORCE FLUIDS. CONTACT THE NEAREST POISON CONTROL CENTER, OR CALL THE NATIONAL POISON CONTROL HOTLINE AT: 1-800-222-1212.
FLAMMABILITY: NOT FLAMMABLE EXTINGUISHING MEDIA: USE MEDIA SUITABLE FOR THE PRIMARY SOURCE OF THE FIRE SPECIAL PROCEDURES: IF THIS PRODUCT IS INVOLVED IN A FIRE, FIREFIGHTERS SHOULD WEAR SELF-CONTAINED BREATHING APPARATUS AND FULL TURN-OUT GEAR FLASH POINT (C), METHOD: NONE AUTO IGNITION TEMPERATURE: NONE SPECIAL FIRE FIGHTING PROCEDURES: NONE SUGGESTED UNUSUAL FIRE AND EXPLOSION HAZARDS: THIS PRODUCT MAY EVOLVE TOXIC FUMES (AMMONIA, HYDROGEN CHLORIDE IF HEATED TO DECOMPOSITION.
STEPS TO BE TAKEN IF MATERIAL IS SPILLED OR RELEASED: WEAR RECOMMENDED PROTECTIVE CLOTHING. REMOVE CONTAMINATED GARMENTS PROMPTLY. SWEEP UP MATERIAL AND COLLECT IN A WATERPROOF RECOVERY CONTAINER. UNDAMAGED PRODUCT MAY BE RECOVERED AND USED ACCORDING TO LABEL INSTRUCTIONS. DO NOT CONTAMINATE MUNICIPAL SEWERS OR OTHER OPEN BODIES OF WATER WITH RUNOFF FROM CLEANUP.
AVOID CONTACT WITH SKIN AND EYES. AVOID BREATHING DUST. KEEP CONTAINERS CLOSED WHEN NOT IN USE. STORE IN A DRY, COOL, AREA. EMPTY CONTAINERS MAY RETAIN RESIDUE. ALL CONTAINERS SHOULD BE DISPOSED OF IN AN ENVIRONMENTALLY SAFE MANNER, AND IN ACCORDANCE WITH ALL GOVERNMENTAL REGULATIONS. KEEP THIS AND ALL CHEMICALS OUT OF THE REACH OF CHILDREN.
RESPIRATORY PROTECTION (SPECIFY TYPE): USE IN A WELL-VENTILATED AREA. IF DUST IS BEING GENERATED AND EXCEEDS THE TLV, A RESPIRATORY PROGRAM MEETING OSHA 1910.134 AND ANSI Z88.2 REQUIREMENTS MUST BE FOLLOWED. VENTILATION: LOCAL EXHAUST IS RECOMMENDED WHEN USED IN ENCLOSED AREAS. PROTECTIVE GLOVES: NEOPRENE, LATEX OR OTHER MATERIALS MAY BE USED IF THERE IS DOCUMENTED EVIDENCE OF COMPATIBILITY. EYE PROTECTION: SAFETY GLASSES (ANSI Z87.1) OR APPROVED EQUIVALENT AS NECESSARY TO MINIMIZE EYE CONTACT HAZARDS. OTHER PROTECTIVE CLOTHING: NEOPRENE APRONS, OVERSHOES, OVERSLEEVES OR OTHER IMPERVIOUS CLOTHING AS NECESSARY TO MINIMIZE EXPOSURE. WORK HYGIENIC PRACTICES: USE PROPER INDUSTRIAL HYGIENE PRACTICES TO MINIMIZE HAZARDOUS EXPOSURE. WASH HANDS AFTER HANDLING THIS MATERIAL, AND BEFORE EATING OR SMOKING.
BOILING POINT: NOT APPLICABLE SPECIFIC GRAVITY (H2O = 1): 1.12-1.13 VAPOR PRESSURE (MMHg): NOT APPLICABLE MELTING POINT (POUR POINT): NOT APPLICABLE VAPOR DENSITY (AIR = 1): NOT APPLICABLE EVAPORATION RATE (WATER = 1): NOT APPLICABLE SOLUBILITY IN WATER: 100% APPEARANCE AND ODOR: GRANULAR ORANGE SOLID WITH A LAVENDER ODOR
STABILITY: STABLE CONDITIONS TO AVOID: NONE INCOMPATIBILITY (MATERIALS TO AVOID): STRONG OXIDIZERS, STRONG ACIDS, FORMALDEHYDE HAZARDOUS DECOMPOSITION OR BYPRODUCTS: IF THIS PRODUCT IS INVOLVED IN A FIRE, IT MAY EVOLVE CARBON MONOXIDE, CARBON DIOXIDE, HYDROGEN CHLORIDE, AMMONIA GAS AND OTHER UNIDENTIFIED FRAGMENTS. HAZARDOUS POLYMERIZATION: WILL NOT OCCUR.
EXPOSURE LIMIT: SEE SECTION 02 CARCINOGENIC: NONE KNOWN REPRODUCTIVE EFFECTS: NONE KNOWN IRRITANT: SEE SECTION 03
NO DATA FOR THIS PRODUCT
WASTE DISPOSAL: DISPOSE OF CONTAMINATED MATERIAL IN ACCORDANCE WITH MUNICIPAL, PROVINCIAL AND FEDERAL REGULATIONS.
DOT HAZARD LABEL: ORM-D IN QUANTITIES LESS THAN 2.2 LB OR 1 KG DOT DESCRIPTION: CLEANING COMPOUND, NOI, OTHER THAN LIQUID SHIPPING NAME: CORROSIVE SOLID, BASIC, INORGANIC, NOS (SODIUM METASILICATE AND POTASSIUM CARBONATE) UN NUMBER: UN3262 CLASS: 8 PACKING GROUP: III (LIMITED QUANTITY)
TSCA: ALL INGREDIENTS ARE TSCA LISTED SARA TITLE III REPORTING REQUIREMENTS: SECTION 302: EHS REPORTING NOT REQUIRED SECTION 304: HAZARDOUS RELEASES REPORTING NOT REQUIRED SECTION 311: COMMUNITY RIGHT TO KNOW REPORTING IS REQUIRED IF THE INVENTORY IS ABOVE THE THRESHOLD PLANNING QUANTITY. SECTION 312: RTK INVENTORY DATA REPORTING IS NOT REQUIRED. SECTION 313: EMISSIONS AND RELEASE REPORTING MAY BE REQUIRED FOR USERS OF THIS PRODUCT WITHIN THE MANUFACTURING SECTOR. THIS DOES NOT APPLY TO SERVICE COMPANIES. WHMIS CLASSIFICATION: D2B CPR COMPLIANCE: THIS PRODUCT HAS BEEN CLASSIFIED IN ACCORDANCE WITH THE HAZARD CRITERIA OF THE CPR AND THE MSDS CONTAINS ALL THE INFORMATION REQUIRED BY THE CPR.
HMIS HAZARD RATINGS: HEALTH 2 FIRE 0 REACTIVITY 0 0=MINIMAL 1=SLIGHT 2=MODERATE 3=HIGH 4=EXTREME OSHA PERSONAL PROTECTION INDEX: B 17. MANUFACTURER: SPECIALTY CHEMICAL MANUFACTURING A DIVERSITECH COMPANY 1633-B HIGH BRIDGE ROAD QUINCY, FL 32351 PHONE: 1+678.542.3600 EMERGENCY PHONE NO.: 1+800.255.3924 CHEM-TEL (CHEMICAL EMERGENCIES ONLY) THIS INFORMATION IS, TO THE BEST OF OUR KNOWLEDGE AND BELIEF, ACCURATE AND RELIABLE AS OF THE DATE COMPLETED. HOWEVER NO REPRESENTATION, WARRANTY OR GUARANTEE IS MADE AS TO ITS ACCURACY, RELIABILITY OR COMPLETENESS. IT IS THE USER'S RESPONSIBILITY TO SATISFY HIMSELF AS TO THE COMPLETENESS AND SUITABILITY OF SUCH INFORMATION FOR HIS OWN PARTICULAR USE. WE DO NOT ACCEPT LIABILITY FOR ANY LOSS OR DAMAGE THAT MAY OCCUR FROM THE USE OF THIS INFORMATION, NOR DO WE OFFER ANY WARRANTY AGAINST PATENT INFRINGEMENT. DIVERSITECH CORPORATION 6650 SUGARLOAF PARKWAY DULUTH, GA 30097 CHEMICAL EMERGENCY: P: 800-255-3924 P: 678.542.3600 F: 678.542.3700 |