SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. MATERIAL SAFETY DATA SHEET POW-R PATCH(R*) FIBERGLASS REPAIR KIT ATI ACCESS-ABLE TECHNOLOGIES, INC. VERSION: 1 PRINT DATE: 06/01/2008
TRADE NAME: POW-R PATCH(R*) FIBERGLASS REPAIR KIT PRODUCT TYPE: EPOXY ADHESIVE MSDS NUMBER: 5 COMPANY: ACCESS-ABLE TECHNOLOGIES, INC. 1275 BENNETT DRIVE UNIT #115 LONGWOOD, FLORIDA 32750 UNITED STATES TELEPHONE: (407) 834-2999 EMERGENCY TELEPHONE NUMBER: (800) 572-4894
CHEMICAL NAME CAS NO# WEIGHT % EPOXY RESIN 25068-38-6 45 2,4,6 - TRIS(DIMETHYLAMINOMETHY) PHENOL 90-72-2 10 MERCAPTAN TERMINATED POLYMER * 45 * TRADE SECRET
HUMAN HEALTH HAZARDS: MAY BE IRRITATING TO THE EYES AND SKIN. CONTACT WITH HOT MATERIAL CAN CAUSE THERMAL BURNS. MAY CAUSE SKIN SENSITIZATION. SAFETY HAZARDS: MATERIAL WILL NOT BURN UNLESS PREHEATED.
INHALATION: REMOVE VICTIM TO FRESH AIR AND PROVIDE OXYGEN IF BREATHING IS DIFFICULT. GIVE ARTIFICIAL RESPIRATION IF NOT BREATHING. GET MEDICAL ATTENTION. SKIN CONTACT: IN CASE OF CONTACT WITH HOT PRODUCT, IMMEDIATELY FLOOD THE AFFECTED AREA WITH COLD WATER. WIPE EXCESS MATERIAL FROM EXPOSED AREA. FLUSH SKIN WITH WATER AND FOLLOW BY WASHING WITH SOAP IF AVAILABLE. REMOVE CONTAMINATED CLOTHING; IF CLOTHING IS STUCK TO A BURN AREA DO NOT PULL IT OFF, BUT CUT AROUND IT. COVER BURN AREA WITH A CLEAN MATERIAL. TRANSPORT TO NEAREST MEDICAL FACILITY FOR ADDITIONAL TREATMENT. EYE CONTACT: FLUSH EYE WITH PLENTY OF COLD WATER FOR AT LEAST 15 MINUTES. DO NOT RUB EYES. GET MEDICAL ATTENTION IMMEDIATELY. INGESTION: DO NOT INDUCE VOMITING. HAVE VICTIM RINSE OUT MOUTH WITH WATER. DRINK LARGE AMOUNTS OF WATER FOLLOWED BY MILK IF AVAILABLE. OBTAIN MEDICAL ATTENTION. IF VOMITING SHOULD OCCUR SPONTANEOUSLY, KEEP AIRWAY CLEAR, KEEP HEAD ABOVE HIPS TO PREVENT ASPIRATION.
SUITABLE EXTINGUISHING MEDIA: USE WATER FOG, FOAM, DRY CHEMICAL OR CARBON DIOXIDE SPECIFIC HAZARDS DURING FIRE FIGHTING: COOL FIRE-EXPOSED CONTAINERS WITH WATER SPRAY. MATERIAL WILL NOT BURN UNLESS PREHEATED. SPECIAL PROTECTIVE EQUIPMENT FOR FIRE-FIGHTERS: DO NOT ENTER CONFINED FIRE SPACE WITHOUT FULL BUNKER GEAR (HELMET WITH FACE SHIELD, BUNKER COATS, GLOVES AND RUBBER BOOTS), INCLUDING A POSITIVE PRESSURE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS.
PROTECTIVE MEASURES: WEAR SAFETY GLASSES WITH SIDE SHIELDS AND PROTECTIVE CLOTHING. ENGINEERING MEASURES: HANDLE IN THE PRESENCE OF ADEQUATE VENTILATION. SKIN AND BODY PROTECTION: WEAR CHEMICAL RESISTANT GLOVES AND OTHER CLOTHING AS REQUIRED. RESPIRATORY PROTECTION: NO RESPIRATORY PROTECTION IS USUALLY REQUIRED UNDER NORMAL CONDITIONS OF USE. NIOSH/OSHA APPROVED RESPIRATOR IF NECESSARY. EXPOSURE GUIDELINES: COMPONENTS WITH WORKSPACE REGULATIONS EXPOSURE TIME VALUE REMARKS CONTROL PARAMETERS COMPONENTS A & B ACGIH NONE ESTABLISHED
CONDITIONS TO AVOID: AVOID HIGH TEMPERATURES MATERIALS TO AVOID: STRONG OXIDIZING AGENTS. HAZARDOUS REACTIONS: STABLE UNDER NORMAL USE CONDITIONS.
ACUTE ORAL TOXICITY: LOW TOXICITY, LD50: >2000 MG./KG. ACUTE DERMAL TOXICITY: LOW TOXICITY, LD 50: >2000 MG./KG. CHRONIC HEALTH HAZARD: EYE IRRITATION: 16.8 (SCALE 0-110) SKIN IRRITATION: 1.2 (SCALE 0-8) SKIN SENSITIZATION: MAY CAUSE SKIN SENSITIZATION CARCINOGENICITY: THIS PRODUCT IS NOT TO BE A CARCINOGEN BY IARC, ACGIH, NTP, OR OSHA MUTAGENICITY: NONE
PRODUCT DISPOSAL: IF THIS MATERIAL BECOMES A WASTE, IT WOULD NOT BE A HAZARDOUS WASTE BY RCRA (40 CFR 261). PLACE IN AN APPROPRIATE DISPOSAL FACILITY IN COMPLIANCE WITH LOCAL AND FEDERAL REGULATIONS.
DOT: NOT REGULATED AS DANGEROUS GOODS CFR_ROAD: NOT REGULATED FOR TRANSPORTATION IATA_C: NOT REGULATED FOR TRANSPORTATION IMDG: NOT REGULATED FOR TRANSPORTATION CFR_RAIL: NOT REGULATED FOR TRANSPORTATION
HEALTH 2 FIRE 1 REACTIVITY 0 ALL INFORMATION, RECOMMENDATIONS, AND SUGGESTIONS APPEARING HEREIN CONCERNING OUR PRODUCT ARE BASED UPON TESTS AND DATA BELIEVED TO BE RELIABLE. HOWEVER, IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE SAFETY, TOXICITY, AND SUITABILITY FOR HIS OWN USE OF THE PRODUCT DESCRIBED HEREIN. SINCE THE ACTUAL USE BY OTHERS IS BEYOND OUR CONTROL, NO GUARANTEE, EXPRESS OR IMPLIED, IS MADE BY ACCESS-ABLE TECHNOLOGIES, INC. AS TO THE EFFECTS OF SUCH USE, THE RESULTS OBTAINED, OR THE SAFETY AND TOXICITY OF THE PRODUCT NOR DOES ACCESS-ABLE TECHNOLOGIES, INC. ASSUME ANY LIABILITY ARISING OUT OF USE, BY OTHERS, OF THE PRODUCT REFERRED TO HEREIN. THE INFORMATION HEREIN IS NOT TO BE CONSTRUED AS ABSOLUTELY COMPLETE SINCE ADDITIONAL INFORMATION MAY BE NECESSARY OR DESIRABLE WHEN PARTICULAR OR EXCEPTIONAL CONDITIONS OR CIRCUMSTANCES EXIST OR BECAUSE OF APPLICABLE LAWS OR GOVERNMENT REGULATIONS. |