Common Name: COMPRESSED AIR
Manufacturer: ENERGAS UK
SDS Revision Date: 11/1/2005
SDS Format: No Format Specified
   
Item Number(s): 3EUG6, 3EUG7
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION 
2. COMPOSITION/INFORMATION ON INGREDIENTS 
3. HAZARDOUS PROPERTIES 
4. FIRST AID MEASURES 
5. FIRE FIGHTING MEASURES 
6. ACCIDENTAL RELEASE MEASURES 
7. HANDLING AND STORAGE 
8. EXPOSURE CONTROLS/PERSONAL PROTECTION 
9. PHYSICAL AND CHEMICAL PROPERTIES 
10. STABILITY AND REACTIVITY 
11. TOXICOLOGICAL INFORMATION 
12. ECOLOGICAL INFORMATION 
13. DISPOSAL CONSIDERATIONS 
14. TRANSPORT INFORMATION 
15. REGULATORY INFORMATION 
16. OTHER INFORMATION 
1. GENERAL 
2 HANDLING AND USE 
3 STORAGE 



ENERGAS

3EUG6

MSDS FOR COMPRESSED AIR

REV: 5(11/2005)

010


1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION 

                 AND OF THE COMPANY

PRODUCT NAME: COMPRESSED AIR

COMPANY IDENTIFICATION:
ENERGAS LIMITED
WESTMORLAND STREET
HULL HU2 0HX

EMERGENCY TELEPHONE NO: 01482 329333


2. COMPOSITION/INFORMATION ON INGREDIENTS 


SUBSTANCE/ PREPARATION: SUBSTANCE

COMPONENTS/IMPURITIES:
CONTAINS NO OTHER IMPURITIES WHICH WILL INFLUENCE THE CLASSIFICATION OF THE
PRODUCT.

CAS NUMBER: N/A


3. HAZARDOUS PROPERTIES 


COMPRESSED GAS.


4. FIRST AID MEASURES 


INHALATION: NON-HAZARDOUS.

SKIN/EYE CONTACT:
IF EYES ARE SUBJECTED TO HIGH-PRESSURE BLAST SEEK MEDICAL ASSISTANCE.


5. FIRE FIGHTING MEASURES 


SUITABLE EXTINGUISHING MEDIA: ALL KNOWN EXTINGUISHANTS CAN BE USED.

SPECIFIC HAZARDS:
EXPOSURE TO FIRE MAY CAUSE CONTAINERS TO RUPTURE/EXPLODE. NON-FLAMMABLE.

SPECIFIC METHODS:
IF POSSIBLE STOP FLOW OF PRODUCT.
MOVE CONTAINER AWAY OR COOL WITH WATER FROM A PROTECTED POSITION.

HAZARD COMBUSTION PRODUCTS: NONE.

SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTERS:
IN CONFINED SPACES USE SELF-CONTAINED BREATHING APPARATUS.


6. ACCIDENTAL RELEASE MEASURES 


PERSONAL PRECAUTIONS: NONE.

ENVIRONMENTAL PRECAUTIONS: NONE.

CLEAN UP METHODS: NONE.


7. HANDLING AND STORAGE 


HANDLING:
REFER TO ENERGAS STORAGE AND HANDLING INSTRUCTIONS.
USE ONLY PROPERLY SPECIFIED EQUIPMENT, WHICH IS SUITABLE FOR THIS PRODUCT,
ITS SUPPLY PRESSURE AND TEMPERATURE.

OPEN CYLINDER VALVE SLOWLY TO AVOID PRESSURE SHOCK.
DO NOT ALLOW BACKFEED INTO THE CONTAINER.
SUCK BACK OF WATER INTO THE CONTAINER MUST BE PREVENTED.
CONTACT ENERGAS LIMITED IF IN DOUBT.

STORAGE: KEEP CONTAINER BELOW 50 DEG. C IN A WELL-VENTILATED PLACE.


8. EXPOSURE CONTROLS/PERSONAL PROTECTION 


NONE REQUIRED.


9. PHYSICAL AND CHEMICAL PROPERTIES 


APPEARANCE/COLOR: COLORLESS GAS.

ODOR: ODORLESS

MOLECULAR WEIGHT: 28.96

RELATIVE DENSITY (GAS): 1 (AIR = 1)

SOLUBILITY (WATER): 0.0292 MG/L


10. STABILITY AND REACTIVITY 


STABLE UNDER NORMAL CONDITIONS


11. TOXICOLOGICAL INFORMATION 


NO KNOWN TOXICOLOGICAL EFFECTS FROM THIS PRODUCT.


12. ECOLOGICAL INFORMATION 


NO KNOWN ECOLOGICAL EFFECTS FROM THIS PRODUCT.


13. DISPOSAL CONSIDERATIONS 


VENT TO ATMOSPHERE IN A WELL VENTILATED PLACE.
CONTACT ENERGAS LIMITED IF GUIDANCE IS REQUIRED.


14. TRANSPORT INFORMATION 


UN NO.: 1002

CLASS/DIVISION: 2.2

ADR/RID ITEM: 2.2

EMERGENCY ACTION CODE: 2T

HAZARD IDENTIFICATION NO.: 20

CEFIC TREMCARD NO.: 843

LABELING ADR:
LABEL 2.2: NON-TOXIC, NON-FLAMMABLE GAS.

ENSURE VEHICLE DRIVER IS AWARE OF THE POTENTIAL HAZARDS OF THE LOAD AND
KNOWS WHAT TO DO IN THE EVENT OF AN ACCIDENT OR EMERGENCY.

ENSURE ALL CYLINDER VALVES ARE CLOSED AND NOT LEAKING AND THE LOAD IS
FIRMLY SECURED AND COMPLIES WITH THE APPLICABLE REGULATIONS.


15. REGULATORY INFORMATION 


EC CLASSIFICATION: NOT CLASSIFIED AS A DANGEROUS SUBSTANCE.

SYMBOLS:
ROAD TRANSPORT SYMBOLS ARE USED AND SELECTED TO THE MOST STRINGENT PRODUCT
CLASSIFICATION.

EC OR ADR - LABEL 2.2: NON-TOXIC, NON-FLAMMABLE GAS.

RISK PHRASES: NONE.

SAFETY PHRASES: NONE.


16. OTHER INFORMATION 


VALVE CONNECTION: BS 341 NO. 3

ENSURE ALL USERS OF THIS PRODUCT UNDERSTAND THE HAZARDS OF HIGH-PRESSURE
GAS.

BEFORE USING THIS PRODUCT IN ANY NEW PROCESS OR EXPERIMENT, A THOROUGH
MATERIAL COMPATIBILITY AND SAFETY STUDY SHOULD BE CARRIED OUT.

DETAILS GIVEN IN THIS DOCUMENT ARE BELIEVED CORRECT AT THE TIME OF GOING TO
PRESS.

WHILST PROPER CARE HAS BEEN TAKEN IN THE PREPARATION OF THIS DOCUMENT, NO
LIABILITY FOR INJURY OR DAMAGE RESULTING FROM ITS USE CAN BE ACCEPTED.

REFER TO ENERGAS LIMITED GENERAL SAFETY AND HANDLING DATA SHEET FOR FURTHER
DETAILS.

ENERGAS

MSDS FOR COMPRESSED AIR

REV: 5(11/2005)

010

CYLINDER IDENTIFICATION TO BS EN 1089-3

SHOULDER COLOR: LIGHT BLUE (RAL 5012)

ENERGAS GENERAL SAFETY AND HANDLING DATA


1. GENERAL 


ONLY TRAINED PERSONS SHOULD HANDLE COMPRESSED GASES.

OBSERVE ALL REGULATIONS AND LOCAL REQUIREMENTS REGARDING THE STORAGE OF
CONTAINERS.

DO NOT REMOVE OR DEFACE LABELS PROVIDED BY THE SUPPLIER FOR THE
IDENTIFICATION OF THE CONTAINER CONTENTS.

ASCERTAIN THE IDENTITY OF THE GAS BEFORE USING IT.

KNOW AND UNDERSTAND THE PROPERTIES AND HAZARDS ASSOCIATED WITH EACH GAS
BEFORE USING IT.

WHEN DOUBT EXISTS AS TO THE CORRECT HANDLING PROCEDURE FOR A PARTICULAR GAS
CONTACT THE SUPPLIER.


2 HANDLING AND USE 


WEAR STOUT GLOVES.

NEVER LIFT A CONTAINER BY THE CAP OR GUARD UNLESS THE SUPPLIER STATES IT IS
DESIGNED FOR THAT PURPOSE.

USE A TROLLEY OR OTHER SUITABLE DEVICE OR TECHNIQUE FOR TRANSPORTING HEAVY
CONTAINERS, EVEN FOR A SHORT DISTANCE.

WHERE NECESSARY WEAR SUITABLE EYE AND FACE PROTECTION. THE CHOICE BETWEEN
SAFETY GLASSES, CHEMICAL GOGGLES, OR FULL-FACE SHIELD WILL DEPEND ON THE
PRESSURE AND NATURE OF THE GAS BEING USED.

WHERE NECESSARY FOR TOXIC GASES SEE THAT SELF-CONTAINED POSITIVE PRESSURE
BREATHING APPARATUS OR FULL FACE AIR LINE RESPIRATOR IS AVAILABLE IN THE
VICINITY OF THE WORKING AREA.

EMPLOY SUITABLE PRESSURE REGULATING DEVICES ON ALL CONTAINERS WHEN THE GAS
IS BEING EMITTED TO SYSTEMS WITH A LOWER PRESSURE RATING THAN THAT OF THE
CONTAINER.

ASCERTAIN THAT ALL ELECTRICAL SYSTEMS IN THE AREA ARE SUITABLE FOR SERVICE
WITH EACH GAS.

NEVER USE DIRECT FLAME OR ELECTRICAL HEATING DEVICES TO RAISE THE PRESSURE
OF A CONTAINER. CONTAINERS SHOULD NOT BE SUBJECTED TO TEMPERATURES ABOVE
45 DEG. C.

NEVER RE-COMPRESS A GAS MIXTURE WITHOUT CONSULTING THE SUPPLIER.
NEVER ATTEMPT TO TRANSFER GASES FROM ONE CONTAINER TO ANOTHER.

DO NOT USE CONTAINERS AS ROLLERS OR SUPPORTS, OR FOR ANY OTHER PURPOSE THAN
TO CONTAIN THE GAS AS SUPPLIED.

NEVER PERMIT OIL, GREASE OR OTHER READILY COMBUSTIBLE SUBSTANCES TO COME
INTO CONTACT WITH VALVES OF CONTAINERS CONTAINING OXYGEN OR OTHER OXIDANTS.

KEEP CONTAINER VALVE OUTLETS CLEAN AND FREE FROM CONTAMINANTS, PARTICULARLY
OIL AND WATER.

DO NOT SUBJECT CONTAINERS TO ABNORMAL MECHANICAL SHOCKS WHICH MAY CAUSE
DAMAGE TO THEIR VALVES OR SAFETY DEVICES.

NEVER ATTEMPT TO REPAIR OR MODIFY CONTAINER VALVES OR SAFETY RELIEF
DEVICES. DAMAGED VALVES SHOULD BE REPORTED IMMEDIATELY TO THE SUPPLIER.

CLOSE THE CONTAINER VALVE WHENEVER GAS IS NOT REQUIRED EVEN IF THE
CONTAINER IS STILL CONNECTED TO THE EQUIPMENT.


3 STORAGE 


CONTAINERS SHOULD BE STORED IN A WELL-VENTILATED AREA. SOME GASES WILL
REQUIRE A PURPOSE BUILT AREA.

STORE CONTAINERS IN A LOCATION FREE FROM FIRE RISK AND AWAY FROM SOURCES OF
HEAT AND IGNITION. DESIGNATION AS A NO SMOKING AREA MAY BE DESIRABLE.

GAS CONTAINERS SHOULD BE SEGREGATED IN THE STORAGE AREA ACCORDING TO THE
VARIOUS CATEGORIES.

THE STORAGE AREA SHOULD BE KEPT CLEAR AND ACCESS SHOULD BE RESTRICTED TO
AUTHORIZED PERSONS ONLY, THE AREA SHOULD BE CLEARLY MARKED AS A STORAGE
AREA AND APPROPRIATE HAZARD WARNING SIGNS DISPLAYED (FLAMMABLE TOXIC ETC,).

THE AMOUNT OF FLAMMABLE OR TOXIC GASES SHOULD BE KEPT TO A MINIMUM.

FLAMMABLE GASES SHOULD BE STORED AWAY FROM OTHER COMBUSTIBLE MATERIALS.

CONTAINERS HELD IN STORAGE SHOULD BE PERIODICALLY CHECKED FOR GENERAL
CONDITION AND LEAKAGE.

CONTAINERS IN STORAGE SHOULD BE PROPERLY SECURED TO PREVENT TOPPLING OR
ROLLING.

VERTICAL STORAGE IS RECOMMENDED WHERE THE CONTAINER IS DESIGNED FOR THIS.

CONTAINER VALVES SHOULD BE TIGHTLY CLOSED AND WHERE APPROPRIATE, VALVE
OUTLETS SHOULD BE CAPPED OR PLUGGED. PROTECT CONTAINERS STORED IN THE OPEN
AGAINST RUSTING AND EXTREMES OF WEATHER.

CONTAINERS SHOULD NOT BE STORED IN CONDITIONS LIKELY TO ENCOURAGE
CORROSION.

STORE FULL AND EMPTY CONTAINERS SEPARATELY AND ARRANGE FULL CONTAINERS SO
THAT THE OLDEST STOCK IS USED FIRST.

PRODUCTION SITE ADDRESSES:

ENGINEERING AND WELDING LIMITED
WESTMORLAND STREET
HULL
HU2 0HX

TEL: 01482 329333

FAX: 01482 212335

ENERGAS LIMITED
HASLAMS LANE
ALFRETON ROAD
DERBY, DE22 1EB

TEL: 01332 364121

FAX: 01332 291590

ENERGAS LIMITED
BROWNROYD STREET
OFF THORNTON ROAD
BRADFORD
WEST YORKSHIRE, BD8 9AF

TEL: 01274 549090

FAX: 01274 548181

FOR FURTHER INFORMATION CONTACT YOUR NEAREST DISTRIBUTION CENTRE