Common Name: AD-TECH 236
Manufacturer: ADHESIVE TECHNOLOGIES
SDS Revision Date: 10/19/2006
SDS Format: No Format Specified
   
Item Number(s): 2KFJ4, 2KFJ5, 2KFJ6, 2KFJ7, 2KFJ8, 2KFJ9, 2KFK1
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 
SECTION 2 - COMPOSITION / INFORMATION ON INGREDIENTS 
SECTION 3 - PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 4 - FIRE - FIGHTING MEASURES 
SECTION 5 - STABILITY AND REACTIVITY 
SECTION 6 - HEALTH HAZARD INFORMATION 
SECTION 7 - SPILL, LEAK, AND DISPOSAL PROCEDURES 
SECTION 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION 
SECTION 9 - SPECIAL PRECAUTIONS AND COMMENTS 



MATERIAL SAFETY DATA SHEET

AD-TECH 236

MSDS NO.: 236-99

DATE OF PREPARATION: FEB. 10,1999


SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 


PRODUCT/CHEMICAL NAME: AD-TECH 236

PRODUCT DESCRIPTION: HOT MELT ADHESIVE

MANUFACTURER:
ADHESIVE TECHNOLOGIES, INC.
3 MERRILL INDUSTRIAL DRIVE
HAMPTON, N.H. 03842

AND

TAIPEI HSIEN
TAIWAN

PHONE: (603)-926-1616

FAX: (603) 926-1780 (OPEN 8 A.M. TO 4 P.M. EST).

HMIS:
H   0
F   0
R   0
PPE B

+SEC 8

EMERGENCY OVERVIEW:


SECTION 2 - COMPOSITION / INFORMATION ON INGREDIENTS 


INGREDIENT NAME                         CAS NUMBER         % WT OR
                                                           % VOL

THIS PRODUCT IS NOT HAZARDOUS AS        N/A                N/A
DEFINED IN 29 CFR 1910.1200

TOXICITY DATA: CONFORMS TO ASTM D-4236 AS NON TOXIC.


SECTION 3 - PHYSICAL AND CHEMICAL PROPERTIES 


PHYSICAL STATE: 100% SOLIDS.

WATER SOLUBILITY: NIL

APPEARANCE AND ODOR: TRANSLUCENT/CLEAR WITH SLIGHT ODOR.

BOILING POINT: NOT APPLICABLE.

MELTING POINT: 179 DEG. F (82 DEG. C).

VAPOR PRESSURE: NOT APPLICABLE

VISCOSITY: 8,500 CENTIPOISE @ 350 DEG. F

VAPOR DENSITY (AIR=1): NOT APPLICABLE

% VOLATILE: NIL

SPECIFIC GRAVITY (H2O=1, AT 4 DEG. C): .98

EVAPORATION RATE: NOT APPLICABLE.

pH: 8


SECTION 4 - FIRE - FIGHTING MEASURES 


FLASH POINT: >450 DEG. F (>232 DEG. C).

FLASH POINT METHOD: CC.

AUTOIGNITION TEMPERATURE: >800 DEG. F (>427 DEG. C)

EXTINGUISHING MEDIA: CARBON DIOXIDE, FOAM

UNUSUAL FIRE OR EXPLOSION HAZARDS: NONE.

SPECIAL FIRE-FIGHTING INSTRUCTIONS: NONE.

FIRE-FIGHTING EQUIPMENT:
BECAUSE FIRE MAY PRODUCE TOXIC THERMAL DECOMPOSITION PRODUCTS, WEAR A
SELF-CONTAINED BREATHING APPARATUS (SCBA) WITH A FULL FACEPIECE OPERATED
IN PRESSURE-DEMAND OR POSITIVE-PRESSURE MODE.

NFPA:
1
1
0
N/A


SECTION 5 - STABILITY AND REACTIVITY 


STABILITY: STABLE

POLYMERIZATION: HAZARDOUS POLYMERIZATION WILL NOT OCCUR.

INCOMPATIBILITIES - MATERIALS TO AVOID: STRONG OXIDIZING AGENTS.

HAZARDOUS DECOMPOSITION PRODUCTS:
THERMAL OXIDATIVE DECOMPOSITION OF AD-TECH 236 CAN PRODUCE CARBON MONOXIDE
AND/OR CARBON DIOXIDE.


SECTION 6 - HEALTH HAZARD INFORMATION 


POTENTIAL HEALTH EFFECTS:

EYES:
VAPORS AND FUMES RELEASED AT OR ABOVE APPLICATION TEMPERATURE MAY CAUSE
IRRITATION.

INHALATION:
VAPORS AND FUMES RELEASED AT OR ABOVE APPLICATION TEMPERATURE MAY CAUSE
IRRITATION OF THE NOSE, THROAT AND RESPIRATORY TRACT.

SKIN: HOT MOLTEN ADHESIVE WILL BURN AND BLISTER SKIN TISSUE.

INGESTION:
INGESTION IS NOT A LIKELY ROUTE OF EXPOSURE. SMALL AMOUNTS ARE NOT
ANTICIPATED TO BE HARMFUL.

CARCINOGENICITY:
IARC, NTP, AND OSHA DO NOT LIST AD-TECH 236 AS A CARCINOGEN.

MEDICAL CONDITIONS AGGRAVATED BY LONG-TERM EXPOSURE:
NO KNOW EFFECTS ON OTHER ILLNESSES.

CHRONIC EFFECTS: NO ANTICIPATED CHRONIC EFFECTS.

EMERGENCY AND FIRST AID PROCEDURES:

INHALATION: IF IRRITATION OCCURS, REMOVE TO FRESH AIR.

EYE CONTACT:
HOT MOLTEN ADHESIVE WILL ADHERE TO AND BURN EYE AND SURROUNDING SKIN UPON
CONTACT. IMMEDIATELY FLUSH AFFECTED AREA WITH COLD WATER TO COOL ADHESIVE.
DO NOT PULL SOLIDIFIED ADHESIVE FROM EYE. SEEK MEDICAL ATTENTION.

SKIN CONTACT:
HOT MOLTEN ADHESIVE WILL ADHERE TO AND BURN SKIN UPON CONTACT. IMMEDIATELY
IMMERSE AFFECTED AREA IN ICE WATER. DO NOT PULL SOLIDIFIED ADHESIVE FROM
SKIN. SEEK MEDICAL ATTENTION.

INGESTION: IF INGESTED, SEEK MEDICAL ATTENTION.

AFTER FIRST AID, GET APPROPRIATE IN-PLANT, PARAMEDIC, OR COMMUNITY MEDICAL
SUPPORT.

NOTE TO PHYSICIANS:
THIS ADHESIVE WAS DETERMINED BY A TOXICOLOGIST TO BE NON-TOXIC.

SPECIAL PRECAUTIONS/PROCEDURES: NONE.


SECTION 7 - SPILL, LEAK, AND DISPOSAL PROCEDURES 


CLEANUP: NORMAL HOUSEKEEPING AND CLEAN UP (NO SPECIAL PROCEDURES).

REGULATORY REQUIREMENTS: NONE.

DISPOSAL:
FOLLOW APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS FOR PROPER DISPOSAL
PROCEDURES.

EPA REGULATIONS:
RCRA HAZARDOUS WASTE NUMBER: NOT APPLICABLE.

RCRA HAZARDOUS WASTE CLASSIFICATION: NOT APPLICABLE.

CERCLA HAZARDOUS SUBSTANCE (40 CFR 302.4):
UNLISTED, SPECIFIC PER RCRA, SEC. 3001; CWA, SEC. 311 (B)(4); CWA, SEC.
307(A), CAA, SEC. 112

CERCLA REPORTABLE QUANTITY (RQ), NOT APPLICABLE.

SARA 311/312 CODES: NOT APPLICABLE.

SARA TOXIC CHEMICAL (40 CFR 372.65): NOT LISTED

SARA EHS (EXTREMELY HAZARDOUS SUBSTANCE) (40 CFR 355):
NOT APPLICABLE, NON-HAZARDOUS.

OSHA REGULATIONS:
AIR CONTAMINANT (29 CFR 1910.1000, TABLE Z-1, Z-1-A): NOT APPLICABLE.
OSHA SPECIFICALLY REGULATED SUBSTANCE (29 CFR 1910).: NOT APPLICABLE.

STATE REGULATIONS: NONE.


SECTION 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION 


ENGINEERING CONTROLS: LOCAL VENTILATION RECOMMENDED.

VENTILATION:
PROVIDE GENERAL OR LOCAL EXHAUST VENTILATION TO AREAS USING THIS ADHESIVE.
LOCAL EXHAUST VENTILATION IS PREFERRED BECAUSE IT PREVENTS CONTAMINANT
DISPERSION INTO THE WORK AREA BY CONTROLLING IT AT ITS SOURCE.

ADMINISTRATIVE CONTROLS: NOT APPLICABLE.

RESPIRATORY PROTECTION: NOT REQUIRED UNDER NORMAL USE.

PROTECTIVE CLOTHING/EQUIPMENT:
WEAR PROTECTIVE GLOVES AND LONG SLEEVED SHIRT TO PREVENT SKIN CONTACT. WEAR
PROTECTIVE EYEGLASSES OR SAFETY GOGGLES, PER OSHA EYE- AND FACE-PROTECTION
REGULATIONS (29 CFR 1910.133). CONTACT LENSES ARE NOT EYE PROTECTIVE
DEVICES. APPROPRIATE EYE PROTECTION MUST BE WORN INSTEAD OF, OR IN
CONJUNCTION WITH CONTACT LENSES.

SAFETY STATIONS:
MAKE EMERGENCY EYEWASH STATIONS, SAFETY/QUICK-DRENCH SHOWERS, AND WASHING
FACILITIES AVAILABLE IN WORK AREA.

CONTAMINATED EQUIPMENT:
COOLED ADHESIVE MAY BE REMOVED FROM CLOTHING BY FREEZING AFFECTED AREA AND
PICKING OFF.

COMMENTS:
NEVER EAT, DRINK, OR SMOKE IN WORK AREAS. PRACTICE GOOD PERSONAL HYGIENE
AFTER USING THIS MATERIAL, ESPECIALLY BEFORE EATING, DRINKING, SMOKING,
USING THE TOILET, OR APPLYING COSMETICS.


SECTION 9 - SPECIAL PRECAUTIONS AND COMMENTS 


HANDLING PRECAUTIONS: NO SPECIAL HANDLING NECESSARY.

STORAGE REQUIREMENTS: STORE IN COOL DARK AREA.

PREPARED BY: DENNIS FITZMEYER.

REVISION NOTES: REVISED 10/19/06

DISCLAIMER:
THE INFORMATION PROVIDED HERE REPRESENTS OUR CURRENT DATA AND BEST OPINION
AS TO THE PROPER USE IN HANDLING OF THIS MATERIAL UNDER NORMAL CONDITIONS.
ANY USE OF THE MATERIAL WHICH IS NOT IN CONFORMANCE WITH THIS DATA SHEET
OR WHICH INVOLVES USING THE MATERIAL IN COMBINATION WITH ANY OTHER MATERIAL
OR ANY OTHER PROCESS IS THE RESPONSIBILITY OF THE USER.