SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. LOCTITE(R*) MATERIAL SAFETY DATA SHEET HENKEL REVISION NUMBER: 001.1 ISSUE DATE: 07/07/2009
PRODUCT NAME: LOCTITE FM SLF LVL CRK FIL PT A PRODUCT TYPE: EPOXY RESIN IDH NUMBER: 1292743 ITEM NUMBER: 1291113_210517 REGION: UNITED STATES COMPANY ADDRESS: HENKEL CORPORATION 1001 TROUT BROOK CROSSING ROCKY HILL, CONNECTICUT 06067 CONTACT INFORMATION: TELEPHONE: 860.571.5100 EMERGENCY TELEPHONE: 860.571.5100 INTERNET: WWW.HENKELNA.COM
EMERGENCY OVERVIEW: PHYSICAL STATE: LIQUID COLOR: AMBER ODOR: SLIGHT HMIS: HEALTH 2* FLAMMABILITY 1 PHYSICAL HAZARD 1 PERSONAL PROTECTION SEE MSDS SECTION 8 WARNING: HARMFUL IF INHALED. MAY CAUSE ALLERGIC SKIN AND RESPIRATORY REACTION. MAY CAUSE EYE, SKIN AND RESPIRATORY TRACT IRRITATION. MAY CAUSE LUNG DAMAGE. RELEVANT ROUTES OF EXPOSURE: SKIN, INHALATION, EYES, INGESTION, AEROSOLS OR VAPORS CAN BE FORMED DURING HEATING, FOAMING, OR SPRAYING. POTENTIAL HEALTH EFFECTS: INHALATION: METHYLENE BISPHENYL ISOCYANATE (MDI) VAPORS OR MIST AT CONCENTRATIONS ABOVE THE TLV CAN IRRITATE THE MUCOUS MEMBRANES IN THE RESPIRATORY TRACT (NOSE, THROAT, LUNGS) CAUSING RUNNY NOSE, SORE THROAT, COUGHING, CHEST DISCOMFORT, SHORTNESS OF BREATH AND REDUCED LUNG FUNCTION (BREATHING OBSTRUCTION). PERSONS WITH PREEXISTING, NONSPECIFIC BRONCHIAL HYPER-REACTIVITY CAN RESPOND TO CONCENTRATIONS BELOW THE TLV WITH SIMILAR SYMPTOMS AS WELL AS LEAD TO BRONCHITIS, BRONCHIAL SPASM AND PULMONARY EDEMA (FLUID IN LUNGS). CHRONIC: AS A RESULT OF PREVIOUS REPEATED OVEREXPOSURES OR A SINGLE LARGE DOSE, CERTAIN INDIVIDUALS WILL DEVELOP ISOCYANATE SENSITIZATION (CHEMICAL ASTHMA) WHICH WILL CAUSE THEM TO REACT TO A LATER EXPOSURE TO ISOCYANATE AT LEVELS WELL BELOW THE TLV. CHRONIC OVEREXPOSURE TO ISOCYANATES HAS BEEN REPORTED TO CAUSE LUNG DAMAGE. THESE SYMPTOMS, WHICH CAN INCLUDE CHEST TIGHTNESS, WHEEZING, COUGH, SHORTNESS OF BREATH OR ASTHMA ATTACK, COULD BE IMMEDIATE OR DELAYED (UP TO SEVERAL HOURS AFTER EXPOSURE). SIMILAR TO MANY NON-SPECIFIC ASTHMATIC RESPONSES, THERE ARE REPORTS THAT ONCE SENSITIZED AN INDIVIDUAL CAN EXPERIENCE THESE SYMPTOMS UPON EXPOSURE TO DUST, COLD AIR, OR OTHER IRRITANTS. THIS INCREASED LUNG SENSITIVITY CAN PERSIST FOR WEEKS AND IN SEVERE CASES FOR SEVERAL YEARS. OVER EXPOSURE TO ISOCYANATES HAS ALSO BEEN REPORTED TO CAUSE LUNG DAMAGE (INCLUDING DECREASE IN LUNG FUNCTION) WHICH MAY BE PERMANENT. SENSITIZATION CAN EITHER BE TEMPORARY OR PERMANENT. SKIN CONTACT: ISOCYANATES REACT WITH SKIN PROTEIN AND MOISTURE AND CAN CAUSE IRRITATION WHICH MAY INCLUDE THE FOLLOWING SYMPTOMS: REDDENING, SWELLING, RASH, SCALING OR BLISTERING. CURED MATERIAL IS DIFFICULT TO REMOVE. CHRONIC: PROLONGED CONTACT CAN CAUSE REDDENING, SWELLING, RASH, SCALING, BLISTERING AND IN SOME CASES, SKIN SENSITIZATION. INDIVIDUALS WHO HAVE SKIN SENSITIZATION CAN DEVELOP THESE SYMPTOMS FROM CONTACT WITH LIQUID OR VAPOR. ANIMAL TESTS HAVE INDICATED THAT RESPIRATORY SENSITIZATION CAN RESULT FROM SKIN CONTACT WITH MDI. THESE DATA REINFORCE THE NEED TO PREVENT DIRECT SKIN CONTACT WITH MDI. EYE CONTACT: LIQUID, AEROSOLS OR VAPOR ARE IRRITATING AND CAN CAUSE TEARING, REDDENING AND SWELLING. IF LEFT UNTREATED, CORNEAL DAMAGE CAN OCCUR AND INJURY IS SLOW TO HEAL. DAMAGE HOWEVER IS USUALLY REVERSIBLE. SEE SECTION 4 FOR FIRST AID MEASURES. INGESTION: IRRITATION AND CORROSIVE ACTION CAN OCCUR IN THE MOUTH, STOMACH TISSUE AND DIGESTIVE TRACT IF SWALLOWED. SYMPTOMS CAN INCLUDE SORE THROAT, ABDOMINAL PAIN, NAUSEA, VOMITING AND DIARRHEA. EXISTING CONDITIONS AGGRAVATED BY EXPOSURE: ASTHMA. OTHER RESPIRATORY DISORDERS (BRONCHITIS, EMPHYSEMA, BRONCHIAL HYPERREACTIVITY). SKIN ALLERGIES. ECZEMA. THIS MATERIAL IS CONSIDERED HAZARDOUS BY THE OSHA HAZARD COMMUNICATION STANDARD (29 CFR 1910.1200). SEE SECTION 11 FOR ADDITIONAL TOXICOLOGICAL INFORMATION.
HAZARDOUS COMPONENTS CAS NUMBER % UNKNOWN 60 - 100 METHYLENEBIS(PHENYLISOCYANATE) 101-68-8 10 - 30
INHALATION: MOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. GET MEDICAL ATTENTION. SKIN CONTACT: REMOVE CONTAMINATED CLOTHING AND FOOTWEAR. WASH WITH SOAP AND WATER. WASH CLOTHING BEFORE REUSE. FOR SEVERE EXPOSURES, GET UNDER SAFETY SHOWER AFTER REMOVING CLOTHING, THEN GET MEDICAL ATTENTION. FOR LESSER EXPOSURE, SEEK MEDICAL ATTENTION IF IRRITATION DEVELOPS OR PERSISTS AFTER AREA IS WASHED. EYE CONTACT: FLUSH WITH COPIOUS AMOUNTS OF WATER, PREFERABLY, LUKEWARM WATER FOR AT LEAST 15 MINUTES, HOLDING EYELIDS OPEN ALL THE TIME. GET MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. KEEP INDIVIDUAL CALM. GET MEDICAL ATTENTION. NOTES TO PHYSICIAN: EYES: STAIN FOR EVIDENCE OF CORNEAL INJURY. IF CORNEA IS BURNED, INSTILL ANTIBIOTIC STEROID PREPARATION FREQUENTLY. WORKPLACE VAPORS HAVE PRODUCED REVERSIBLE CORNEAL EPITHELIAL EDEMA IMPAIRING VISION. SKIN: TREAT SYMPTOMATICALLY AS FOR CONTACT DERMATITIS OR THERMAL BURNS. THIS COMPOUND IS A KNOWN SKIN SENSITIZER. INGESTION: TREAT SYMPTOMATICALLY. THERE IS NO SPECIFIC ANTIDOTE. INDUCING VOMITING IS CONTRAINDICATED BECAUSE OF THE IRRITATING NATURE OF THIS COMPOUND. RESPIRATORY: THIS COMPOUND IS A KNOWN PULMONARY SENSITIZER.
FLASH POINT: >93 DEG. C (>199.4 DEG. F) AUTOIGNITION TEMPERATURE: NOT AVAILABLE FLAMMABLE/EXPLOSIVE LIMITS - LOWER: NOT AVAILABLE FLAMMABLE/EXPLOSIVE LIMITS - UPPER: NOT AVAILABLE EXTINGUISHING MEDIA: WATER SPRAY (FOG), FOAM, DRY CHEMICAL OR CARBON DIOXIDE. SPECIAL FIREFIGHTING PROCEDURES: WEAR SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING, SUCH AS TURN-OUT GEAR. DURING A FIRE, MDI VAPORS AND OTHER IRRITATING, HIGHLY TOXIC GASES MAY BE GENERATED BY THERMAL DECOMPOSITION OR COMBUSTION. AT TEMPERATURES ABOVE 204.4 DEG. C (400 DEG. F), POLYMERIC MDI CAN POLYMERIZE AND DECOMPOSE WHICH CAN CAUSE PRESSURE BUILD-UP IN CLOSED CONTAINERS. EXPLOSIVE RUPTURE IS POSSIBLE. UNUSUAL FIRE OR EXPLOSION HAZARDS: IN CASE OF FIRE, KEEP CONTAINERS COOL WITH WATER SPRAY. HAZARDOUS COMBUSTION PRODUCTS: OXIDES OF CARBON. OXIDES OF NITROGEN. HYDROGEN CYANIDE. METHYLENE BISPHENYL ISOCYANATE.
USE PERSONAL PROTECTION RECOMMENDED IN SECTION 8, ISOLATE THE HAZARD AREA AND DENY ENTRY TO UNNECESSARY AND UNPROTECTED PERSONNEL. ENVIRONMENTAL PRECAUTIONS: DO NOT ALLOW PRODUCT TO ENTER SEWER OR WATERWAYS. CLEAN-UP METHODS: EVACUATE AND VENTILATE SPILL AREA; DIKE SPILL TO PREVENT ENTRY INTO WATER SYSTEM; WEAR FULL PROTECTIVE EQUIPMENT DURING CLEAN-UP. IF TEMPORARY CONTROL OF ISOCYANATE VAPOR IS REQUIRED, A BLANKET OF PROTEIN FOAM (AVAILABLE AT MOST FIRE DEPARTMENTS) MAY BE PLACED OVER SPILL. LARGE QUANTITIES MAY BE PUMPED INTO CLOSED, BUT NOT SEALED CONTAINERS FOR DISPOSAL. FOR MINOR SPILLS, ABSORB ISOCYANATES WITH SAWDUST OR OTHER ABSORBENT, SHOVEL INTO SUITABLE UNSEALED CONTAINERS, TRANSPORT TO WELL VENTILATED AREA (OUTSIDE) AND TREAT WITH NEUTRALIZING SOLUTION: MIXTURE OF 80% WATER AND 20% NON-IONIC SURFACTANT TERGITOL TMN-10; OR 90% WATER, 3-8% CONCENTRATED AMMONIA AND 2% DETERGENT. ADD ABOUT TEN PARTS OF NEUTRALIZER PER PART OF ISOCYANATE, WITH MIXING. ALLOW TO STAND UNCOVERED FOR 48 HOURS TO LET CARBON DIOXIDE ESCAPE. DECONTAMINATE FLOOR WITH DECONTAMINATION SOLUTION LETTING STAND FOR AT LEAST 15 MINUTES.
HANDLING: AVOID CONTACT WITH EYES, SKIN AND CLOTHING. AVOID BREATHING VAPORS OR MISTS OF THIS PRODUCT. EXPOSURE TO VAPORS OF HEATED MDI CAN BE EXTREMELY DANGEROUS. WASH THOROUGHLY AFTER HANDLING. PROTECT FROM MOISTURE. STORAGE: STORE IN TIGHTLY CLOSED CONTAINERS TO PREVENT MOISTURE CONTAMINATION. DO NOT RESEAL IF CONTAMINATION IS SUSPECTED. MDI REACTS SLOWLY WITH WATER TO FORM CARBON DIOXIDE GAS. THIS GAS CAN CAUSE SEALED CONTAINERS TO EXPAND AND POSSIBLY RUPTURE. IF CONTAINER IS EXPOSED TO HIGH HEAT (204.4 DEG. C (400 DEG. F)), IT CAN BE PRESSURIZED AND POSSIBLY RUPTURE. FOR INFORMATION ON PRODUCT SHELF LIFE CONTACT HENKEL CUSTOMER SERVICE AT (800) 243-4874.
EMPLOYERS SHOULD COMPLETE AN ASSESSMENT OF ALL WORKPLACES TO DETERMINE THE NEED FOR, AND SELECTION OF, PROPER EXPOSURE CONTROLS AND PROTECTIVE EQUIPMENT FOR EACH TASK PERFORMED. HAZARDOUS COMPONENTS ACGIH TLV OSHA PEL AIHA WEEL OTHER NONE NONE NONE NONE METHYLENEBIS 0.005 PPM TWA 0.02 PPM NONE NONE (PHENYLISOCYANATE) (0.2 MG/M3) CEILING ENGINEERING CONTROLS: LOCAL EXHAUST SHOULD BE USED TO MAINTAIN LEVELS BELOW THE TLV WHENEVER MDI IS PROCESSED, HEATED OR SPRAY APPLIED. STANDARD REFERENCE SOURCES REGARDING INDUSTRIAL VENTILATION (I.E., ACGIH INDUSTRIAL VENTILATION) SHOULD BE CONSULTED FOR GUIDANCE ABOUT ADEQUATE VENTILATION. AIR MONITORING: MONITORING OF AIRBORNE ISOCYANATES IN THE BREATHING ZONE OF INDIVIDUALS SHOULD BECOME PART OF THE OVERALL EMPLOYEE EXPOSURE CHARACTERIZATION PROGRAM. ISOCYANATE EXPOSURE LEVELS MUST BE MONITORED. MONITORING TECHNIQUES HAVE BEEN DEVELOPED BY NIOSH AND OSHA. MEDICAL SURVEILLANCE: MEDICAL SUPERVISION OF ALL EMPLOYEES WHO HANDLE OR COME IN CONTACT WITH ISOCYANATES IS RECOMMENDED. THESE SHOULD INCLUDE PREEMPLOYMENT AND PERIODIC MEDICAL EXAMINATIONS WITH PULMONARY FUNCTION TESTS (FEV, FVC AS A MINIMUM). PERSONS WITH ASTHMATIC-TYPE CONDITIONS, CHRONIC BRONCHITIS, OTHER CHRONIC RESPIRATORY DISEASES OR RECURRENT SKIN ECZEMA OR SENSITIZATION SHOULD BE EXCLUDED FROM WORKING WITH ISOCYANATES. ONCE A PERSON IS DIAGNOSED AS SENSITIZED TO AN ISOCYANATE, NO FURTHER EXPOSURE CAN BE PERMITTED. RESPIRATORY PROTECTION: CONCENTRATIONS GREATER THAN THE TLV CAN OCCUR WHEN MDI IS SPRAYED, HEATED OR USED IN A POORLY VENTILATED AREA. IN SUCH CASES, OR WHENEVER CONCENTRATIONS OF MDI EXCEED THE TLV, RESPIRATORY PROTECTION MUST BE WORN. A POSITIVE PRESSURE, SUPPLIED-AIR RESPIRATOR OR A SELF-CONTAINED BREATHING APPARATUS IS RECOMMENDED. IN SITUATIONS WHERE MDI IS NOT SPRAYED, HEATED, OR USED IN A POORLY VENTILATED AREA, AND A SUPPLIED-AIR OR SELF-CONTAINED BREATHING APPARATUS IS UNAVAILABLE OR ITS USE IMPRACTICAL, AT LEAST AN AIR-PURIFYING CARTRIDGE AND PARTICULATE PRE-FILTERS MUST BE WORN. HOWEVER, THIS SHOULD BE PERMITTED ONLY FOR SHORT PERIODS OF TIME (LESS THAN ONE HOUR) AT RELATIVELY LOW CONCENTRATIONS (AT OR NEAR THE TLV). HOWEVER, DUE TO THE POOR WARNING PROPERTIES OF MDI, PROPER FIT AND TIMELY REPLACEMENT OF FILTER ELEMENTS MUST BE ENSURED. OBSERVE OSHA REGULATIONS FOR RESPIRATORY USE (29 CFR 1910.134). EYE/FACE PROTECTION: SAFETY GLASSES WITH SIDESHIELDS OR CHEMICAL SAFETY GOGGLES SHOULD BE WORN IF THERE IS A RISK OF SPLASHING. FULL FACE PROTECTION SHOULD BE USED IF THE POTENTIAL FOR SPLASHING OR SPRAYING OF PRODUCT EXISTS. SKIN PROTECTION: PERMEATION RESISTANT GLOVES (BUTYL RUBBER, NITRILE RUBBER, POLYVINYL ALCOHOL). HOWEVER, PLEASE NOTE THAT POLYVINYL ALCOHOL DEGRADES IN WATER. COVER AS MUCH OF THE EXPOSED SKIN AREA AS POSSIBLE WITH APPROPRIATE CLOTHING. IF SKIN CREAMS ARE USED, KEEP THE AREA COVERED BY THE CREAM TO A MINIMUM.
PHYSICAL STATE: LIQUID COLOR: AMBER ODOR: SLIGHT ODOR THRESHOLD: NOT AVAILABLE pH: NOT AVAILABLE VAPOR PRESSURE: NOT AVAILABLE BOILING POINT/RANGE: 207 DEG. C (404.6 DEG. F) MELTING POINT/RANGE: NOT AVAILABLE SPECIFIC GRAVITY: 1.09 VAPOR DENSITY: NOT AVAILABLE FLASH POINT: >93 DEG. C (>199.4 DEG. F) FLAMMABLE/EXPLOSIVE LIMITS - LOWER: NOT AVAILABLE FLAMMABLE/EXPLOSIVE LIMITS - UPPER: NOT AVAILABLE AUTOIGNITION TEMPERATURE: NOT AVAILABLE EVAPORATION RATE: NOT AVAILABLE SOLUBILITY IN WATER: REACTS SLOWLY WITH WATER TO LIBERATE CARBON DIOXIDE GAS. PARTITION COEFFICIENT (n-OCTANOL/WATER): NOT AVAILABLE VOC CONTENT: 7.84 G/L (VALUE AS MIXED FOR USE)
STABILITY: STABLE HAZARDOUS REACTIONS: CONTACT WITH MOISTURE, OTHER MATERIALS WHICH CAN REACT WITH ISOCYANATES, OR TEMPERATURES ABOVE 204.4 DEG. C (400 DEG. F), MAY CAUSE POLYMERIZATION. HAZARDOUS DECOMPOSITION PRODUCTS: THERMAL DECOMPOSITION CAN LEAD TO RELEASE OF IRRITATING GASES AND VAPORS. OXIDES OF CARBON. OXIDES OF NITROGEN. HYDROGEN CYANIDE. MDI VAPORS AND AEROSOLS. INCOMPATIBLE MATERIALS: WATER. ALCOHOLS. AMINES. AMMONIA. ACIDS. CONDITIONS TO AVOID: CONTAMINATION WITH WATER. HEAT.
HAZARDOUS COMPONENTS NTP CARCINOGEN IARC CARCINOGEN OSHA CARCINOGEN (SPECIFICALLY REGULATED) NO NO NO METHYLENEBIS NO NO NO (PHENYLISOCYANATE) HAZARDOUS COMPONENTS HEALTH EFFECTS/TARGET ORGANS NO DATA METHYLENEBIS(PHENYLISOCYANATE) IRRITANT, RESPIRATORY, ALLERGEN
ECOLOGICAL INFORMATION: FOR BOTH POLYMERIC AND MONOMERIC MDI: AQUATIC TOXICITY - LC50 - 24 HOUR (STATIC): GREATER THAN 500 MG/L FOR DAPHNIA MAGNA, LIMNEA STAGNALIS, AND ZEBRA FISH (BRACHYDANIO RERIO).
INFORMATION PROVIDED IS FOR UNUSED PRODUCT ONLY. RECOMMENDED METHOD OF DISPOSAL: FOLLOW ALL LOCAL, STATE, FEDERAL AND PROVINCIAL REGULATIONS FOR DISPOSAL. HAZARDOUS WASTE NUMBER: NOT A RCRA HAZARDOUS WASTE.
THE SHIPPING CLASSIFICATIONS IN THIS SECTIONS ARE FOR NON-BULK PACKAGING ONLY (UNLESS OTHERWISE SPECIFIED). SHIPPING CLASSIFICATION MAY BE DIFFERENT FOR BULK PACKAGING. U.S. DEPARTMENT OF TRANSPORTATION GROUND (49 CFR): PROPER SHIPPING NAME: NOT REGULATED HAZARD CLASS OR DIVISION: NONE IDENTIFICATION NUMBER: NONE PACKING GROUP: NONE INTERNATIONAL AIR TRANSPORTATION (ICAO/IATA): PROPER SHIPPING NAME: NOT REGULATED HAZARD CLASS OR DIVISION: NONE IDENTIFICATION NUMBER: NONE PACKING GROUP: NONE WATER TRANSPORTATION (IMO/IMDG): PROPER SHIPPING NAME: NOT REGULATED HAZARD CLASS OR DIVISION: NONE IDENTIFICATION NUMBER: NONE PACKING GROUP: NONE
UNITED STATES REGULATORY INFORMATION: TSCA 8(B) INVENTORY STATUS: ALL COMPONENTS ARE LISTED OR ARE EXEMPT FROM LISTING ON THE TOXIC SUBSTANCES CONTROL ACT INVENTORY. TSCA 12(B) EXPORT NOTIFICATION: NONE ABOVE REPORTING DE MINIMUS CERCLA/SARA SECTION 302 EHS: NONE ABOVE REPORTING DE MINIMUS CERCLA/SARA SECTION 311/312: IMMEDIATE HEALTH, DELAYED HEALTH CERCLA/SARA 313: THIS PRODUCT CONTAINS THE FOLLOWING TOXIC CHEMICALS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW ACT OF 1986 (40 CFR 372). METHYLENEBIS (PHENYLISOCYANATE) (CAS# 101-68-8). CALIFORNIA PROPOSITION 65: NO CALIFORNIA PROPOSITION 65 LISTED CHEMICALS ARE KNOWN TO BE PRESENT. CANADA REGULATORY INFORMATION: CEPA DSL/NDSL STATUS: ALL COMPONENTS ARE LISTED ON OR ARE EXEMPT FROM LISTING ON THE CANADIAN DOMESTIC SUBSTANCES LIST. WHMIS HAZARD CLASS: D.1.A, D.2.A, D.2.B
THIS MATERIAL SAFETY DATA SHEET CONTAINS CHANGES FROM THE PREVIOUS VERSION IN SECTIONS: NEW MATERIAL SAFETY DATA SHEET FORMAT. PREPARED BY: GARY PIERSON, SR. REGULATORY AFFAIRS SPECIALIST DISCLAIMER: THE DATA CONTAINED HEREIN ARE FURNISHED FOR INFORMATION ONLY AND ARE BELIEVED TO BE RELIABLE. HOWEVER, HENKEL CORPORATION DOES NOT ASSUME RESPONSIBILITY FOR ANY RESULTS OBTAINED BY PERSONS OVER WHOSE METHODS HENKEL CORPORATION HAS NO CONTROL. IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE SUITABILITY OF HENKEL'S PRODUCTS OR ANY PRODUCTION METHODS MENTIONED HEREIN FOR A PARTICULAR PURPOSE, AND TO ADOPT SUCH PRECAUTIONS AS MAY BE ADVISABLE FOR THE PROTECTION OF PROPERTY AND PERSONS AGAINST ANY HAZARDS THAT MAY BE INVOLVED IN THE HANDLING AND USE OF ANY OF HENKEL CORPORATION'S PRODUCTS. IN LIGHT OF THE FOREGOING, HENKEL CORPORATION SPECIFICALLY DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARISING FROM SALE OR USE OF HENKEL CORPORATION'S PRODUCTS. HENKEL CORPORATION FURTHER DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY KIND, INCLUDING LOST PROFITS. |