SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. PROPANE FUEL THERMADYNE VICTOR7 MATERIAL SAFETY DATA SHEET DATE PREPARED: JANUARY 1, 1991 DATE REVISED: JANUARY 1, 2010 FORM NUMBER: 0056-1297 CORE PART NO: 0916-0004 CHEMTREC PHONE NO.: (800) 424 - 9300 VICTOR EQUIPMENT COMPANY 2800 AIRPORT ROAD DENTON, TEXAS 76207 (940) 566 - 2000 FAX: (940) 381 - 1265 THIS MSDS IS BASED ON AIR/FUEL OR OXY/FUEL PROCESS. THERE MAY BE OTHER CAUTIONS FOR ELECTRIC PROCESS. MATERIAL SAFETY DATA SHEET
PRODUCT NAME: LIQUIFIED PETROLEUM GAS OR PROPANE (0916-0004) PRODUCT USE: HEATING FUEL
OSHA HAZARDOUS COMPONENTS EXPOSURE LIMITS: 8 HR. TWA (29 CFR 1910.1200) OSHA PEL ACGIH TLV PROPANE 100 PPM NOT LISTED (CAS #74-98-6)
EMERGENCY OVERVIEW: FLAMMABLE GAS. MAY CAUSE FLASH FIRE OR EXPLOSION. CONTENTS UNDER PRESSURE. HARMFUL IF INHALED. POTENTIAL HEALTH EFFECTS: INHALATION: MAY CAUSE HEADACHES AND DIZZINESS. MAY CAUSE ASPHYXIATION IN HIGH CONCENTRATIONS. PROLONGED INHALATION MAY BE HARMFUL. EYE CONTACT: DIRECT CONTACT WITH LIQUIFIED GAS CAN RESULT IN EYE BURNS. SKIN CONTACT: NO HAZARD IN NORMAL INDUSTRIAL USE. INGESTION: INGESTION NOT LIKELY, PRODUCT IS A GAS AT ROOM TEMPERATURE. CHRONIC: UNKNOWN. CARCINOGENICITY: LISTED IN NTP?: NO IARC?: NO OSHA REGULATED?: NO
INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION AND/OR GIVE OXYGEN BY TRAINED PERSONNEL. SEEK MEDICAL ATTENTION. EYE CONTACT: IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN CONTACT: WASH WITH SOAP AND WATER. GET MEDICAL ATTENTION IF IRRITATION DEVELOPS OR PERSISTS. INGESTION: NO EMERGENCY CARE ANTICIPATED.
FLASHPOINT (METHOD): -156 DEG. F (ND) FLAMMABLE LIMITS: LOWER: 2.3 UPPER: 9.5 AUTOIGNITION TEMPERATURE: 874 DEG. F GENERAL HAZARD: FLAMMABLE GAS. CAN READILY FORM EXPLOSIVE MIXTURES AT OR ABOVE THE FLASHPOINT. FLASHBACK ALONG VAPOR TRAIL POSSIBLE. FIRE FIGHTING INSTRUCTIONS: EVACUATE AREA AND FIGHT FIRE FROM A SAFE DISTANCE. DO NOT EXTINGUISH A GAS FIRE UNLESS EFFECTIVE IMMEDIATE SHUT-OFF OF GAS FLOW IS POSSIBLE. EXPLOSIVE VAPORS COULD FORM. AS IN ANY FIRE, WEAR SELF-CONTAINED BREATHING APPARATUS PRESSURE-DEMAND, MSHA/NIOSH APPROVED OR EQUIVALENT) AND FULL PROTECTIVE GEAR. EXTINGUISHING MEDIA: DO NOT EXTINGUISH. USE WATER TO COOL CONTAINERS. INCREASE VENTILATION TO PREVENT FLAMMABLE AIR MIXTURE. HAZARDOUS COMBUSTION PRODUCTS: SMOKE, OXIDES OF CARBON.
ELIMINATE ALL IGNITION SOURCES INCLUDING INTERNAL COMBUSTION ENGINES AND POWER TOOLS. VENTILATE AREA. ISOLATE HAZARD AREA. KEEP UNNECESSARY AND UNPROTECTED PERSONNEL FROM ENTERING. AVOID BREATHING VAPORS. AVOID CONTACT WITH EYES, SKIN AND CLOTHING.
USE SPARK-PROOF TOOLS AND EXPLOSION PROOF EQUIPMENT. GROUND AND BOND CONTAINERS WHEN TRANSFERRING MATERIAL. DO NOT REUSE THIS CONTAINER. "EMPTY" CONTAINERS RETAIN PRODUCT RESIDUE (LIQUID AND/OR VAPOR) AND CAN BE DANGEROUS. DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION. THEY MAY EXPLODE AND CAUSE INJURY OR DEATH. EMPTY DRUMS SHOULD BE COMPLETELY DRAINED, PROPERLY SEALED AND PROMPTLY RETURNED TO A DRUM RECONDITIONER, OR DISPOSED OF PROPERLY. KEEP AWAY FROM HEAT, SPARKS AND FLAME. STORE IN A COOL DRY PLACE.
ENGINEERING CONTROLS: USE PROCESS ENCLOSURES, LOCAL EXHAUST VENTILATION, OR OTHER ENGINEERING CONTROLS TO CONTROL AIRBORNE LEVELS BELOW RECOMMENDED EXPOSURE LIMITS. PERSONAL PROTECTION: A RESPIRATORY PROTECTION PROGRAM THAT MEETS OSHA 1910.134 AND ANSI Z88.2 REQUIREMENTS MUST BE FOLLOWED WHENEVER WORKPLACE CONDITIONS WARRANT A RESPIRATOR'S USE. PROTECTIVE CLOTHING: WEAR SAFETY GLASSES WITH SIDE SHIELDS (OR GOGGLES) AND A FACE SHIELD.
VAPOR PRESSURE: 7600 MMHg @ 80 DEG. C VAPOR DENSITY (AIR=1): 1.5 SPECIFIC GRAVITY: 0.50 EVAPORATION RATE (n-BUTYL ACETATE=1): NA SOLUBILITY IN WATER: NEGLIGIBLE pH: NA FREEZING POINT: -306 DEG. F BOILING POINT: -44 DEG. F APPEARANCE & ODOR: COLORLESS GAS WITH NO ODOR. IF ODORIZED, WILL HAVE ROTTEN EGG ODOR.
GENERAL: STABLE INCOMPATIBLE MATERIALS: OXIDIZERS CONDITIONS TO AVOID: HEAT, IGNITION SOURCES. HAZARDOUS POLYMERIZATION: WILL NOT OCCUR.
NO TOXICITY DATA DETERMINED.
NOT APPLICABLE.
DO NOT ATTEMPT TO DISPOSE WASTE OR UNUSED MATERIAL. RETURN IN CONTAINER PROPERLY LABELED, WITH VALVE PROTECTION CAP IN PLACE TO THE SUPPLIER FOR PROPER DISPOSAL. CLASSIFICATION REQUIRED BEFORE DISPOSAL. MATERIAL IS CLASSED AS IGNITABLE WITH A RCRA D001 HAZARDOUS WASTE NUMBER. FOLLOW ALL FEDERAL, STATE AND LOCAL REQUIREMENTS.
PROPER SHIPPING NAME: LIQUIFIED PETROLEUM GAS, 2.1 HAZARD CLASS: FLAMMABLE GAS (2.1) IDENTIFICATION NUMBER: UN 1978 DOT EMERGENCY GUIDE #: 22 REPORTABLE QUANTITY (RQ): 2,000,000 POUNDS (PROPANE) IN A SINGLE CONTAINER.
TSCA (TOXIC SUBSTANCE CONTROL ACT): ALL COMPONENTS ARE LISTED ON THE TSCA INVENTORY. CERCLA (COMPREHENSIVE ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABILITY ACT): 2,000,000 POUNDS. WE RECOMMEND YOU CONTACT LOCAL AUTHORITIES FOR OTHER REPORTING REQUIREMENTS. SARA TITLE III (SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT): 311/312 HAZARD CATEGORIES: ACUTE, IGNITABLE, SUDDEN RELEASE OF PRESSURE. 313 REPORTABLE INGREDIENTS: NONE
PREPARED BY: TALEM, INC. - TECHNICAL SERVICES DIVISION (817) 335 - 1186 FOOTNOTES: NA - NOT APPLICABLE NE - DATA NOT ESTABLISHED CS - CANCER SUSPECT AGENT OX - OXIDIZER ND - NO DATA COR - CORROSIVE CALC - CALCULATED EST - ESTIMATED STEL - SHORT TERM EXPOSURE LIMIT TLV - THRESHOLD LIMIT VALUE PEL - PERMISSIBLE EXPOSURE LIMIT TWA - TIME WEIGHTED AVERAGE, 8 HOURS THE INFORMATION RELATES TO THIS SPECIFIC MATERIAL. IT MAY NOT BE VALID FOR THIS MATERIAL IF USED IN COMBINATION WITH ANY OTHER MATERIALS OR IN ANY PROCESS. IT IS THE USER'S RESPONSIBILITY TO SATISFY ONESELF AS TO THE SUITABILITY AND COMPLETENESS OF THIS INFORMATION FOR HIS OWN PARTICULAR USE. NEITHER THE SELLER NOR PREPARER MAKES ANY WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE INFORMATION PRESENTED. |