Common Name: CORDLESS FUEL CELL
Manufacturer: PASLODE
SDS Revision Date: 9/14/2010
SDS Format: EU
   
Item Number(s): 2HNW2, 2HNW3, 2HNW8, 2HNW9, 2HNX1, 2HNX2, 2HNX3, 2HNX4, 31EE19, 36N563, 36N564, 36N565, 3FRN6, 3FRR7, 3FRR8, 3FRR9, 3FRT1, 3FRT2, 3FRT3, 3FRT4, 3FRT5, 3FRT6, 4WL18, 4WL24, 4WL32, 4WL45, 4WL46, 5VK14, 6HKX4, 6KVX5, 6KVX6
Manufacturer Model Number(s): 650039, 816000, 816001



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
1. PRODUCT AND COMPANY IDENTIFICATION 
2. COMPOSITION / INFORMATION ON INGREDIENTS 
3. HAZARDS IDENTIFICATION 
4. FIRST AID MEASURES 
5. FIRE FIGHTING MEASURES 
6. ACCIDENTAL RELEASE MEASURES 
7. HANDLING AND STORAGE 
8. EXPOSURE CONTROL/PERSONAL PROTECTION 
9. PHYSICAL AND CHEMICAL PROPERTIES 
10. REACTIVITY 
11. TOXICOLOGICAL INFORMATION 
12. ECOLOGICAL INFORMATION 
13. DISPOSAL CONSIDERATIONS 
14. TRANSPORT INFORMATION 
15. REGULATORY INFORMATION 
16. OTHER INFORMATION 



MATERIAL SAFETY DATA SHEET


1. PRODUCT AND COMPANY IDENTIFICATION 


PRODUCT NAME: CORDLESS FUEL CELL

CHEMICAL FAMILY: HYDROCARBONS

CHEMICAL NAME: COMPRESSED, EXTREMELY FLAMMABLE, LIQUIFIED GAS

MANUFACTURER:
PASLODE
888 FOREST EDGE DRIVE
VERNON HILLS, ILLINOIS 60061-3105

INFORMATION TELEPHONE NUMBER: 847-634-1900

EMERGENCY TELEPHONE NUMBER: 800-424-9300 (CHEMTREC)


2. COMPOSITION / INFORMATION ON INGREDIENTS 


(FUEL AND PROPELLANT)

HAZARDOUS INGREDIENTS    CAS NUMBER   CONCENTRATION (% BY WEIGHT)

1-BUTENE (BUTYLENE)      106-98-9     25-80

PROPENE (PROPYLENE)      115-07-1     20-75

EU CLASSIFICATION:
F+, R12: EXTREMELY FLAMMABLE.

EU RISK AND SAFETY PHRASES:
R12: EXTREMELY FLAMMABLE.
S2: KEEP OUT OF THE REACH OF CHILDREN.
S9: KEEP CONTAINER IN A WELL-VENTILATED PLACE.
S16: KEEP AWAY FROM SOURCES OF IGNITION - NO SMOKING.
S33: TAKE PRECAUTIONARY MEASURES AGAINST STATIC DISCHARGES.


3. HAZARDS IDENTIFICATION 


EMERGENCY OVERVIEW:
SELF-PRESSURIZED CONTAINER OF EXTREMELY FLAMMABLE, LIQUIFIED GAS.
STORAGE AT TEMPERATURES ABOVE 120 DEG. F MAY CREATE A FIRE HAZARD.

PRIMARY ROUTES OF ENTRY: RESPIRATORY SYSTEM, EYES AND SKIN.

POTENTIAL HEALTH EFFECTS:

EYE CONTACT:
DIRECT CONTACT WITH LIQUEFIED GAS CAN RESULT IN FROSTBITE ("COLD BURN").

SKIN CONTACT:
EXPOSURE TO EXPANDING GAS OR VAPORIZING LIQUID MAY CAUSE FROSTBITE.

INGESTION:
EXPOSURE TO EXPANDING GAS OR VAPORIZING LIQUID MAY CAUSE FROSTBITE TO
INTERNALORGANS AND TISSUE. INGESTION NOT ANTICIPATED SINCE COMPONENTS OF
FUEL GAS AND PROPELLANT ARE GASEOUS AT AMBIENT PRESSURE AND TEMPERATURE.

INHALATION:
MAY CAUSE ASPHYXIATION IN HIGH CONCENTRATIONS. REPEATED OR PROLONGED
INHALATION MAY CAUSE TOXIC EFFECTS. SEE MSDS SECTION 11 FOR MORE
INFORMATION.

4. FIRST AID MEASURES 


EYE:
IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER. GET IMMEDIATE MEDICAL
ATTENTION.

SKIN:
IN CASE OF FROSTBITE, DO NOT REMOVE CLOTHES. GET IMMEDIATE MEDICAL
ATTENTION.

INGESTION: GET IMMEDIATE MEDICAL ATTENTION.

INHALATION:
REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF
BREATHING IS DIFFICULT, GIVE OXYGEN. GET IMMEDIATE MEDICAL ATTENTION.


5. FIRE FIGHTING MEASURES 


FLASH POINT: APPROXIMATELY -160 DEG. F

FLAMMABILITY LIMITS (% IN AIR BY VOLUME): APPROXIMATELY 2 TO 10

EXTINGUISHING MEDIA: DRY CHEMICAL; CARBON DIOXIDE; FOAM; WATER

SPECIAL FIRE FIGHTING PROCEDURES:
FUEL CELLS MAY RELEASE CONTENTS IF NOT SUFFICIENTLY COOLED WITH WATER SPRAY.
ISOLATE HAZARD AREA AND EVACUATE UNPROTECTED PERSONNEL. FULL EMERGENCY
EQUIPMENT WITH SELF CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE
CLOTHING SHOULD BE WORN BY FIREFIGHTERS.


6. ACCIDENTAL RELEASE MEASURES 


SPILL OR LEAK PROCEDURES:
ELIMINATE SOURCES OF IGNITION.
ISOLATE HAZARD AREA.
VENTILATE HAZARD AREA.


7. HANDLING AND STORAGE 


RECOMMENDED STORAGE TEMPERATURE: BELOW 120 DEG. F

SHELF LIFE:
FOR MAXIMUM NUMBER OF TOOL CYCLES, USE BEFORE DATE CODE ON FUEL CELL.

HANDLING AND STORAGE PRECAUTIONS:
IN ADDITION TO LIMITATIONS ON STORAGE TEMPERATURE, FUEL CELLS SHOULD BE
HANDLED AND STORED SO AS TO AVOID PUNCTURE. EVEN AFTER USE, DO NOT PUNCTURE
FUEL CELL OR EXPOSE FUEL CELL TO HIGH TEMPERATURE. DO NOT ATTEMPT TO REFILL
THE FUEL CELL.


8. EXPOSURE CONTROL/PERSONAL PROTECTION 


EYE PROTECTION REQUIREMENTS:
EYE PROTECTION MUST BE WORN WHEN HANDLING FUEL CELLS.

SKIN PROTECTION REQUIREMENTS:
GLOVES ARE RECOMMENDED WHEN HANDLING FUEL CELLS.

RESPIRATORY/VENTILATION REQUIREMENTS:
USE IN A WELL VENTILATED ENVIRONMENT.

EXPOSURE LIMITS               OSHA PEL          ACGIH
                              (PPM)             (PPM)

1-BUTENE (BUTYLENE)           NE                NE

PROPENE (PROPYLENE)           NE                NE


9. PHYSICAL AND CHEMICAL PROPERTIES 


(FUEL AND PROPELLANT)

PHYSICAL FORM: LIQUIFIED GAS

COLOR: COLORLESS

ODOR: FAINTLY OLEFINIC

BOILING POINT: APPROXIMATELY -50 DEG. F

MELT POINT/FREEZE POINT: APPROXIMATELY -300 DEG. F

pH: NOT APPLICABLE

SOLUBILITY IN WATER: SLIGHTLY

SPECIFIC GRAVITY: APPROXIMATELY 0.6 FOR LIQUEFIED GAS

% VOLATILE BY WEIGHT: 100%

VAPOR PRESSURE: APPROXIMATELY 50 - 150 LB/IN(2) AT 70 DEG. F

VAPOR DENSITY: APPROXIMATELY 1.5 (AIR = 1)


10. REACTIVITY 


STABILITY: PRODUCT IS STABLE.

HAZARDOUS POLYMERIZATION: WILL NOT OCCUR.

INCOMPATIBILITIES: OXIDIZING AGENTS, HALOGENS AND ACIDS.

DECOMPOSITION PRODUCTS:
THERMAL DECOMPOSITION OR BURNING MAY PRODUCE CARBON MONOXIDE OR CARBON
DIOXIDE FROM FUEL GAS COMBUSTION.


11. TOXICOLOGICAL INFORMATION 


ACUTE INHALATION:
LOW TOXICITY - LC50: >5 MG/L (RAT).

COMPONENTS OF FUEL CELL GASES AND PROPELLANT ARE SIMPLE ASPHYXIANTS.
EXPOSURE TO HIGH CONCENTRATIONS OF PROPYLENE HAS BEEN ASSOCIATED WITH
IRREGULAR HEARTBEAT.

CHRONIC INHALATION:
NO SIGNIFICANT EFFECTS HAVE BEEN DEMONSTRATED FOR ANY COMPONENTS EXCEPT
PROPYLENE. CHRONIC EXPOSURE TO PROPYLENE HAS BEEN ASSOCIATED WITH LIVER
DAMAGE.

ACUTE EYE OR SKIN CONTACT:
FROSTBITE ("COLD BURN") CAN RESULT FROM EXPOSURE TO EXPANDING GAS OR
VAPORIZING LIQUID. COMPONENTS OF FUEL CELL GAS AND PROPELLANT AT AMBIENT
PRESSURE AND TEMPERATURE PRODUCE LITTLE OR NO IRRITATION.

CHRONIC EYE OR SKIN CONTACT:
NO SIGNIFICANT EFFECTS HAVE BEEN DEMONSTRATED FOR COMPONENTS OF FUEL CELL
GAS AND PROPELLANT AT AMBIENT PRESSURE AND TEMPERATURE.

CARCINOGENCITY:
NO COMPONENTS OF FUEL CELL GAS OR PROPELLANT ARE CLASSIFIED AS CARCINOGENS
BY IARC, NTP OR OSHA.


12. ECOLOGICAL INFORMATION 


ECOTOXICOLOGICAL AND ENVIRONMENTAL FATE DATA HAVE NOT BEEN DETERMINED
SPECIFICALLY FOR THIS PRODUCT. INFORMATION IS BASED ON INTERNATIONAL UNIFORM
CHEMICAL INFORMATION DATABASE (IUCLID) ENTRIES FOR COMPONENTS OF FUEL CELL
GAS AND PROPELLANT.

ECOTOXICOLOGIAL INFORMATION:
ANAESTHETIC TO ANIMALS AND INSECTS AT HIGH CONCENTRATIONS. NOT EXPECTED TO
POSE HAZARDS TO AQUATIC LIFE. NOT INHIBITORY TO PLANT GROWTH AT AMBIENT
CONCENTRATIONS. BIOACCUMULATION IS NOT EXPECTED.

ENVIRONMENTAL FATE INFORMATION:
VOLATILIZATION IS EXPECTED TO BE PRIMARY FATE PROCESS. COMPONENTS OF FUEL
CELL GAS AND PROPELLANT HAVE PHOTOCHEMICAL REACTIVITY.


13. DISPOSAL CONSIDERATIONS 


WASTE DISPOSAL METHOD:
WASTE MUST BE DISPOSED OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
ENVIRONMENTAL REGULATIONS. SEE RCRA DISCUSSION IN MSDS SECTION 15.


14. TRANSPORT INFORMATION 


U.S. DOT INFORMATION (GROUND SHIPMENT):
PROPER SHIPPING NAME: CONSUMER COMMODITY
HAZARD CLASS: ORM-D
PRODUCT RQ (LBS): NONE
UN NUMBER: NONE
LABEL: NONE

IMDG INFORMATION (VESSEL SHIPMENT):
PROPER SHIPPING NAME: AEROSOLS, LTD QTY
HAZARD CLASS: 2.1
PRODUCT RQ (LBS): NONE
UN NUMBER: UN1950
LABEL: FLAMMABLE GAS


15. REGULATORY INFORMATION 


TSCA STATUS: ALL COMPONENTS ARE INCLUDED IN THE TSCA CHEMICAL INVENTORY.

CERCLA REPORTABLE QUANTITY: NONE

SARA TITLE III:

SECTION 302 EXTREMELY HAZARDOUS SUBSTANCES: NONE

SECTION 311/312 HAZARD CATEGORIES:
ACUTE HEALTH: YES
CHRONIC HEALTH: YES
FIRE: YES
REACTIVE: NO
SUDDEN RELEASE OF PRESSURE: YES

SECTION 313 TOXIC CHEMICALS:

PROPENE (PROPYLENE):
CAS NO. 115-07-1
20-75% BY WEIGHT

RCRA STATUS:
IF DISCARDED IN ITS PURCHASED FORM, THIS PRODUCT MAY BE CLASSIFIED AS A D001
(IGNITABLE) HAZARDOUS WASTE. EVEN AFTER USE, THE FUEL CELL REMAINS
PRESSURIZED BY AN EXTREMELY FLAMMABLE PROPELLANT AND MAY RETAIN THESE
HAZARDOUS WASTE CHARACTERISTICS. WASTE GENERATORS MUST CONSIDER FEDERAL,
STATE AND LOCAL HAZARDOUS WASTE REGULATIONS TO DETERMINE A PROPER DISPOSAL
METHOD BASED ON THEIR STATUS AS A CONDITIONALLY EXEMPT, SMALL QUANTITY OR
LARGE QUANTITY GENERATOR.

CANADIAN STATUS: ALL COMPONENTS LISTED ON DOMESTIC SUBSTANCES LIST (DSL).

EUROPEAN UNION:

ALL COMPONENTS LISTED ON EUROPEAN INVENTORY OF EXISTING COMMERCIAL CHEMICAL
SUBSTANCES (EINECS):

COMPONENT                                   EINECS NO.

1-BUTENE                                    203-449-2

PROPENE                                     204-062-1

STATE REGULATORY INFORMATION:
NO COMPONENT OF FUEL GAS OR PROPELLANT IS INCLUDED ON CALIFORNIA
PROPOSITION 65 LISTS AS A CARCINOGEN OR REPRODUCTIVE TOXIN.


16. OTHER INFORMATION 


HMIS CLASSIFICATION:
HEALTH       1
FLAMMABILITY 4
REACTIVITY   0
PPE          *

* TO BE DETERMINED BY USER UNDER SPECIFIC CONDITIONS.

REASON FOR ISSUE: ADDED VESSEL INFORMATION IN SECTION 14

PREPARED BY: KEN BROWN, CHMM

ISSUE DATE: 9/14/10

SUPERCEDES VERSION DATED: 7/29/10

THE INFORMATION CONTAINED IN THIS MATERIAL SAFETY DATA SHEET IS PROVIDED
WITHOUT WARRANTY, EXPRESSED OR IMPLIED, EXCEPT THAT IT IS ACCURATE TO THE
BEST KNOWLEDGE OF PASLODE. THE DATA ON THIS SHEET RELATE ONLY TO THE
CORDLESS FUEL CELL. PASLODE ASSUMES NO LEGAL RESPONSIBILITY FOR USE OR
RELIANCE UPON THESE DATA.