SDS Table of Contents Click the desired link below to jump directly to that section in the SDS.
MAINTENANCE-FREE SEALED LEAD-ACID BATTERY MANUFACTURER'S MSDS DISTRIBUTED BY: DUAL-LITE MSDS #: 4 MATERIAL SAFETY DATA SHEET DATE: MARCH 19, 2010 PRODUCT NAME: PRC SEALED MAINTENANCE FREE BATTERIES HAZARDOUS COMPONENTS: LEAD, SULFURIC ACID TELEPHONE NO.: NOT APPLICABLE
COMPONENT NO. CAS % WEIGHT LEAD (Pb, PbO2, PbSO4) 7439-92-1 65-75% SULFURIC ACID 7664-93-9 17-30% COMPONENT OSHA PEL(TLV) LD50 LD50 LD50 ORAL INHALATION CONTACT LEAD (Pb, PbO2, PbSO4) 0.050 MG/M3 500 MG/KG 20 MG/M3 N/A SULFURIC ACID 1 MG/M3 2.140 KG/KG 18 MG/M3 135 MG/KG
COMPONENT DENSITY MELTING POINT SOLUBILITY ODOR APPEARANCE (BOILING) IN WATER LEAD 11.34 GM/CM3 621.5 DEG. F NONE NONE SILVER-GRAY METAL LEAD SULFATE 6.2 GM/CM3 2132 DEG. F .43 MG/L NONE WHITE POWDER LEAD DIOXIDE 9.375 GM/CM3 D. 554 DEG. F NONE NONE BROWN POWDER SULFURIC 1.290 GM/CM5 235 DEG. F 100% NONE CLEAR ACID COLORLESS LIQUID
COMPONENT FLASH POINT EXPLOSIVE COMMENTS LIMITS LEAD NONE NONE USE "ABC" TYPE FIRE EXTINGUISHER FOR BATTERY FIRES. SULFURIC ACID NONE NONE HYDROGEN <0 DEG. F 4%-74.2% PRC SEALED BATTERIES CAN EMIT HYDROGEN ONLY IF OVER CHARGED (FLOAT VOLTAGE 2.40 VPC OR GREATER).
LEAD: THE TOXIC EFFECTS OF LEAD ARE ACCUMULATIVE, AND SLOW TO APPEAR. IT AFFECTS THE KIDNEYS, REPRODUCTIVE, AND CENTRAL NERVOUS SYSTEMS. THE SYMPTOMS OF LEAD OVER EXPOSURE ARE ANEMIA, VOMITING, HEADACHE, STOMACH PAIN (LEAD COLIC), DIZZINESS, LOSS OF APPETITE AND MUSCLES AND JOINTS PAIN. EXPOSURE TO LEAD FROM A BATTERY MOST OFTEN OCCURS DURING LEAD RECLAIM OPERATION THROUGH THE BREATHING OR INGESTION OF LEAD DUSTS AND FUMES. THIS SHEET MUST BE PASSED TO ANY SCRAP DEALER OR SMELTER WHEN THE BATTERY IS RESOLD. SULFURIC ACID: SULFURIC ACID IS A STRONG CORROSIVE CONTACT WITH THE ACID CAN CAUSE SEVERE BURNS TO THE SKIN AND EYES. INGESTION OF SULFURIC ACID WILL CAUSE GASTRO INTESTINAL TRACT BURNS. SEE OTHER SIDE FOR FIRST AID INSTRUCTIONS.
COMPONENT: SULFURIC ACID STABILITY: STABLE AT ALL TEMPERATURES POLYMERIZATION: WILL NOT POLYMERIZE INCOMPATIBILITY: REACTIVE METALS, STRONG BASES, MOST ORGANIC COMPOUNDS DECOMPOSITION PRODUCTS: SULFURIC DIOXIDE, SULPHER TRIOXIDE, HYDROGEN SULFIDE, HYDROGEN CONDITIONS TO AVOID: PROHIBIT SMOKING, SPARKS, FLAMES, ETC. FROM BATTERY CHARGING AREA. AVOID MIXING ACID WITH OTHER CHEMICALS.
STEPS TO TAKE IN CASE OF LEAK OR SPILL: IF SULFURIC ACID IS SPILLED FROM A BATTERY, NEUTRALIZE THE ACID WITH SODIUM BICARBONATE (BAKING SODA), SODIUM CARBONATE (SODA ASH) OR CALCIUM OXIDE (LIME). FLUSH THE AREA WITH WATER, AND DISPOSE OF AS HAZARDOUS WASTE WASTE DISPOSAL METHOD: 1) SPENT LEAD ACID BATTERIES ARE DISPOSED OF USING THREE (3) ACCEPTABLE METHODS: SEND THE BATTERIES TO: (A) LICENSED SECONDARY LEAD SMELTERS FOR RECYCLING (B) REPUTABLE BATTERY HANDLERS (C) REPUTABLE SCRAP DEALERS. 2) IF THE USER HAS TO TRANSPORT THESE BATTERIES TO THE SMELTERS, THE USER MUST FOLLOW DEPARTMENT OF TRANSPORTATION (DOT) REGULATIONS. A COPY OF THIS MATERIAL SAFETY DATA SHEET MUST BE SUPPLIED TO ANY SCRAP DEALER OR SECONDARY LEAD SMELTER. FOLLOW APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS.
EXPOSURE SITE: PROTECTION SKIN: RUBBER GLOVES, APRON RESPIRATORY: PROTECTIVE EQUIPMENT MUST BE WORN IF THE BATTERY IS CRACKED OR OTHERWISE DAMAGED. HEPA RESPIRATOR SHOULD BE WORN DURING RECLAIM OPERATIONS, IF THE OSHA PEL IS EXCEEDED. EYES: SAFETY GOGGLES, FACE SHIELD
DUE TO THE PRC BATTERY'S LOW INTERNAL RESISTANCE AND HIGH POWER DENSITY, HIGH LEVELS OF SHORT CIRCUIT CURRENT CAN BE DEVELOPED ACROSS THE BATTERY TERMINALS. DO NOT REST TOOLS OR CABLES ON THE BATTERY. USE INSULATED TOOLS ONLY. FOLLOW ALL INSTALLATION INSTRUCTIONS AND DIAGRAMS WHEN INSTALLING OR MAINTAINING BATTERY SYSTEMS.
SULFURIC ACID: SKIN CONTACT: FLUSH WITH WATER, SEE PHYSICIAN IF CONTACT AREA IS LARGE, OR IF BLISTERS FORM. EYE CONTACT: CALL PHYSICIAN IMMEDIATELY, FLUSH WITH WATER UNTIL PHYSICIAN ARRIVES. INGESTION: CALL PHYSICIAN. DO NOT INDUCE VOMITING. DO NOT GIVE ANYTHING TO AN UNCONSCIOUS PERSON. FAX DOC: 5303 |