Common Name: SUVA 134A AUTO
Manufacturer: DU PONT
SDS Revision Date: 9/12/2011
SDS Format: No Format Specified
   
Item Number(s): 3HY80, 4M599, 5DPW4
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION 
SECTION 2. HAZARDS IDENTIFICATION 
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION 4. FIRST AID MEASURES 
SECTION 5. FIREFIGHTING MEASURES 
SECTION 6. ACCIDENTAL RELEASE MEASURES 
SECTION 7. HANDLING AND STORAGE 
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION 
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10. STABILITY AND REACTIVITY 
SECTION 11. TOXICOLOGICAL INFORMATION 
SECTION 12. ECOLOGICAL INFORMATION 
SECTION 13. DISPOSAL CONSIDERATIONS 
SECTION 14. TRANSPORT INFORMATION 
SECTION 15. REGULATORY INFORMATION 
SECTION 16. OTHER INFORMATION 



DUPONT(R*)

MATERIAL SAFETY DATA SHEET

DUPONT(TM) SUVA(R*) 134A AUTO

VERSION: 2.3

REVISION DATE: 09/12/2011

REF.: 130000024024

THIS SDS ADHERES TO THE STANDARDS AND REGULATORY REQUIREMENTS OF THE UNITED
STATES AND MAY NOT MEET THE REGULATORY REQUIREMENTS IN OTHER COUNTRIES.


SECTION 1. PRODUCT AND COMPANY IDENTIFICATION 


PRODUCT NAME: DUPONT(TM) SUVA(R*) 134A AUTO

TRADE NAME/SYNONYM:
SUVA(R*) 134A AUTO
HFC 134A

MSDS NUMBER: 130000024024

PRODUCT USE: REFRIGERANT

MANUFACTURER:
DUPONT
1007 MARKET STREET
WILMINGTON, DE 19898

PRODUCT INFORMATION: 1-800-441-7515 (OUTSIDE THE U.S. 1-302-774-1000)

MEDICAL EMERGENCY: 1-800-441-3637 (OUTSIDE THE U.S. 1-302-774-1139)

TRANSPORT EMERGENCY:
CHEMTREC: 1-800-424-9300 (OUTSIDE THE U.S. 1-703-527-3887)


SECTION 2. HAZARDS IDENTIFICATION 


EMERGENCY OVERVIEW: RAPID EVAPORATION OF THE LIQUID MAY CAUSE FROSTBITE.

POTENTIAL HEALTH EFFECTS:

SKIN:
1,1,1,2-TETRAFLUOROETHANE:
CONTACT WITH LIQUID OR REFRIGERATED GAS CAN CAUSE COLD BURNS AND FROSTBITE.
MAY CAUSE SKIN IRRITATION.

MAY CAUSE: DISCOMFORT, ITCHING, REDNESS, OR SWELLING.

EYES:
1,1,1,2-TETRAFLUOROETHANE:
CONTACT WITH LIQUID OR REFRIGERATED GAS CAN CAUSE COLD BURNS AND FROSTBITE.
MAY CAUSE EYE IRRITATION.

MAY CAUSE: TEARING, REDNESS, DISCOMFORT.

INHALATION:
1,1,1,2-TETRAFLUOROETHANE:
MISUSE OR INTENTIONAL INHALATION ABUSE MAY CAUSE DEATH WITHOUT WARNING
SYMPTOMS, DUE TO CARDIAC EFFECTS.

OTHER SYMPTOMS POTENTIALLY RELATED TO MISUSE OR INHALATION ABUSE ARE:
ANAESTHETIC EFFECTS, LIGHT-HEADEDNESS, DIZZINESS, CONFUSION,
INCOORDINATION, DROWSINESS, OR UNCONSCIOUSNESS, IRREGULAR HEARTBEAT WITH A
STRANGE SENSATION IN THE CHEST, HEART THUMPING, APPREHENSION, FEELING OF
FAINTING, DIZZINESS OR WEAKNESS.

VAPOURS ARE HEAVIER THAN AIR AND CAN CAUSE SUFFOCATION BY REDUCING OXYGEN
AVAILABLE FOR BREATHING.

CARCINOGENICITY:
NONE OF THE COMPONENTS PRESENT IN THIS MATERIAL AT CONCENTRATIONS EQUAL TO
OR GREATER THAN 0.1% ARE LISTED BY IARC, NTP, OR OSHA, AS A CARCINOGEN.


SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS 


COMPONENT                      CAS-NO.        CONCENTRATION

1,1,1,2-TETRAFLUOROETHANE      811-97-2       100%


SECTION 4. FIRST AID MEASURES 


SKIN CONTACT:
IN CASE OF CONTACT, IMMEDIATELY FLUSH SKIN WITH PLENTY OF WATER FOR AT
LEAST 15 MINUTES. TAKE OFF ALL CONTAMINATED CLOTHING IMMEDIATELY. CONSULT
A PHYSICIAN. WASH CONTAMINATED CLOTHING BEFORE RE-USE. TREAT FOR FROSTBITE
IF NECESSARY BY GENTLY WARMING AFFECTED AREA.

EYE CONTACT:
IN CASE OF CONTACT, IMMEDIATELY FLUSH EYES WITH PLENTY OF WATER FOR AT
LEAST 15 MINUTES. CONSULT A PHYSICIAN IF NECESSARY.

INHALATION:
REMOVE FROM EXPOSURE, LIE DOWN. MOVE TO FRESH AIR. KEEP PATIENT WARM AND
AT REST. ARTIFICIAL RESPIRATION AND/OR OXYGEN MAY BE NECESSARY. CONSULT A
PHYSICIAN.

INGESTION: IS NOT CONSIDERED A POTENTIAL ROUTE OF EXPOSURE.

GENERAL ADVICE:
NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. WHEN SYMPTOMS
PERSIST OR IN ALL CASES OF DOUBT SEEK MEDICAL ADVICE.

NOTES TO PHYSICIAN:
BECAUSE OF POSSIBLE DISTURBANCES OF CARDIAC RHYTHM, CATECHOLAMINE DRUGS,
SUCH AS EPINEPHRINE, THAT MAY BE USED IN SITUATIONS OF EMERGENCY LIFE
SUPPORT SHOULD BE USED WITH SPECIAL CAUTION.


SECTION 5. FIREFIGHTING MEASURES 


FLAMMABLE PROPERTIES:
FLASH POINT: DOES NOT FLASH

LOWER EXPLOSION LIMIT:
METHOD: NONE PER ASTM E681

UPPER EXPLOSION LIMIT:
METHOD: NONE PER ASTM E681

FIRE AND EXPLOSION HAZARD:
HAZARDOUS THERMAL DECOMPOSITION PRODUCTS:
CARBON OXIDES
HYDROGEN FLUORIDE
CARBONYL FLUORIDE

CYLINDERS ARE EQUIPPED WITH PRESSURE AND TEMPERATURE RELIEF DEVICES, BUT
MAY STILL RUPTURE UNDER FIRE CONDITIONS. DECOMPOSITION MAY OCCUR. CONTACT
OF WELDING OR SOLDERING TORCH FLAME WITH HIGH CONCENTRATIONS OF REFRIGERANT
CAN RESULT IN VISIBLE CHANGES IN THE SIZE AND COLOUR OF THE TORCH FLAME.
THIS FLAME EFFECT WILL ONLY OCCUR IN CONCENTRATIONS OF PRODUCT WELL ABOVE
THE RECOMMENDED EXPOSURE LIMIT. THEREFORE STOP ALL WORK AND VENTILATE TO
DISPERSE REFRIGERANT VAPORS FROM THE WORK AREA BEFORE USING ANY OPEN
FLAMES.

HFC-134A IS NOT FLAMMABLE IN AIR AT TEMPERATURES UP TO 100 DEG. C
(212 DEG. F) AT ATMOSPHERIC PRESSURE. HOWEVER, MIXTURES OF HFC-134A WITH
HIGH CONCENTRATIONS OF AIR AT ELEVATED PRESSURE AND/OR TEMPERATURE CAN
BECOME COMBUSTIBLE IN THE PRESENCE OF AN IGNITION SOURCE. HFC-134A CAN
ALSO BECOME COMBUSTIBLE IN AN OXYGEN ENRICHED ENVIRONMENT (OXYGEN
CONCENTRATIONS GREATER THAN THAT IN AIR). WHETHER A MIXTURE CONTAINING
HFC-134A AND AIR, OR HFC-134A IN AN OXYGEN ENRICHED ATMOSPHERE BECOME
COMBUSTIBLE DEPENDS ON THE INTER-RELATIONSHIP OF 1) THE TEMPERATURE 2) THE
PRESSURE, AND 3) THE PROPORTION OF OXYGEN IN THE MIXTURE. IN GENERAL,
HFC-134A SHOULD NOT BE ALLOWED TO EXIST WITH AIR ABOVE ATMOSPHERIC
PRESSURE OR AT HIGH TEMPERATURES; OR IN AN OXYGEN ENRICHED ENVIRONMENT.
FOR EXAMPLE HFC-134A SHOULD NOT BE MIXED WITH AIR UNDER PRESSURE FOR LEAK
TESTING OR OTHER PURPOSES.

EXPERIMENTAL DATA HAVE ALSO BEEN REPORTED WHICH INDICATE COMBUSTIBILITY
OF THIS SUBSTANCE IN THE PRESENCE OF CERTAIN CONCENTRATIONS OF CHLORINE.

FIREFIGHTING INSTRUCTIONS:
IN THE EVENT OF FIRE, WEAR SELF-CONTAINED BREATHING APPARATUS.

USE EXTINGUISHING MEASURES THAT ARE APPROPRIATE TO LOCAL CIRCUMSTANCES AND
THE SURROUNDING ENVIRONMENT. COOL CONTAINERS / TANKS WITH WATER SPRAY.
WATER RUNOFF SHOULD BE CONTAINED AND NEUTRALIZED PRIOR TO RELEASE.


SECTION 6. ACCIDENTAL RELEASE MEASURES 


NOTE:
REVIEW FIRE FIGHTING MEASURES AND HANDLING (PERSONNEL) SECTIONS BEFORE
PROCEEDING WITH CLEANUP. USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT
DURING CLEAN-UP.

SAFEGUARDS (PERSONNEL):
EVACUATE PERSONNEL TO SAFE AREAS. VENTILATE AREA, ESPECIALLY LOW OR
ENCLOSED PLACES WHERE HEAVY VAPOURS MIGHT COLLECT.

ACCIDENTAL RELEASE MEASURES:
SHOULD NOT BE RELEASED INTO THE ENVIRONMENT.

SELF-CONTAINED BREATHING APPARATUS (SCBA) IS REQUIRED IF A LARGE RELEASE
OCCURS. AVOID OPEN FLAMES AND HIGH TEMPERATURES.


SECTION 7. HANDLING AND STORAGE 


HANDLING (PERSONNEL):
USE SUFFICIENT VENTILATION TO KEEP EMPLOYEE EXPOSURE BELOW RECOMMENDED
LIMITS. FOR PERSONAL PROTECTION SEE SECTION 8.

HANDLING (PHYSICAL ASPECTS):
THE PRODUCT SHOULD NOT BE MIXED WITH AIR FOR LEAK TESTING OR USED WITH AIR
FOR ANY OTHER PURPOSE ABOVE ATMOSPHERIC PRESSURE. CONTACT WITH CHLORINE OR
OTHER STRONG OXIDIZING AGENTS SHOULD ALSO BE AVOIDED.

STORAGE:
VALVE PROTECTION CAPS AND VALVE OUTLET THREADED PLUGS MUST REMAIN IN PLACE
UNLESS CONTAINER IS SECURED WITH VALVE OUTLET PIPED TO USE POINT. DO NOT
DRAG, SLIDE OR ROLL CYLINDERS. USE A SUITABLE HAND TRUCK FOR CYLINDER
MOVEMENT. USE A PRESSURE REDUCING REGULATOR WHEN CONNECTING CYLINDER TO
LOWER PRESSURE (>3000 PSIG) PIPING OR SYSTEMS. NEVER ATTEMPT TO LIFT
CYLINDER BY ITS CAP. USE A CHECK VALVE OR TRAP IN THE DISCHARGE LINE TO
PREVENT HAZARDOUS BACK FLOW INTO THE CYLINDER. CYLINDERS SHOULD BE STORED
UPRIGHT AND FIRMLY SECURED TO PREVENT FALLING OR BEING KNOCKED OVER.

SEPARATE FULL CONTAINERS FROM EMPTY CONTAINERS. KEEP AT TEMPERATURE NOT
EXCEEDING 52 DEG. C. DO NOT STORE NEAR COMBUSTIBLE MATERIALS. AVOID AREA
WHERE SALT OR OTHER CORROSIVE MATERIALS ARE PRESENT.

STORAGE TEMPERATURE: <52 DEG. C (<126 DEG. F)


SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION 


ENGINEERING CONTROLS:
NORMAL VENTILATION FOR STANDARD MANUFACTURING PROCEDURES IS GENERALLY
ADEQUATE. LOCAL EXHAUST SHOULD BE USED WHEN LARGE AMOUNTS ARE RELEASED.
MECHANICAL VENTILATION SHOULD BE USED IN LOW OR ENCLOSED PLACES.
REFRIGERANT CONCENTRATION MONITORS MAY BE NECESSARY TO DETERMINE VAPOUR
CONCENTRATIONS IN WORK AREAS PRIOR TO USE OF TORCHES OR OTHER OPEN FLAMES,
OR IF EMPLOYEES ARE ENTERING ENCLOSED AREAS.

PERSONAL PROTECTIVE EQUIPMENT:

RESPIRATORY PROTECTION:
FOR RESCUE AND MAINTENANCE WORK IN STORAGE TANKS USE SELF-CONTAINED
BREATHING APPARATUS. VAPOURS ARE HEAVIER THAN AIR AND CAN CAUSE
SUFFOCATION BY REDUCING OXYGEN AVAILABLE FOR BREATHING.

HAND PROTECTION:
ADDITIONAL PROTECTION: IMPERVIOUS GLOVES

EYE PROTECTION: WEAR COVERALL CHEMICAL SPLASH GOGGLES.

EXPOSURE GUIDELINES:

EXPOSURE LIMIT VALUES:
1,1,1,2-TETRAFLUOROETHANE:
AEL * (DUPONT): 1,000 PPM 8 & 12 HR. TWA

* AEL IS DUPONT'S ACCEPTABLE EXPOSURE LIMIT. WHERE GOVERNMENTALLY IMPOSED
OCCUPATIONAL EXPOSURE LIMITS WHICH ARE LOWER THAN THE AEL ARE IN EFFECT,
SUCH LIMITS SHALL TAKE PRECEDENCE.


SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES 


FORM: LIQUEFIED GAS

COLOR: COLOURLESS

ODOR: SLIGHT, ETHER-LIKE

BOILING POINT/BOILING RANGE: -26.5 DEG. C (-15.7 DEG. F) AT 1,013 HPA

% VOLATILE: 100%

VAPOUR PRESSURE:
6,661 HPA AT 25 DEG. C (77 DEG. F)
13,190 HPA AT 50 DEG. C (122 DEG. F)

DENSITY: 1.206 G/CM3 AT 25 DEG. C (77 DEG. F) (AS LIQUID)

DENSITY: 0.0042 G/CM3 AT 25 DEG. C (77 DEG. F) AT (1,013 HPA)

DENSITY: 0.0053 G/CM3 AT -26.1 DEG. C (-15.0 DEG. F) AT (1,013 HPA)

SPECIFIC GRAVITY: 1.208 AT 25 DEG. C (77 DEG. F)

WATER SOLUBILITY: 1.5 G/L AT 25 DEG. C (77 DEG. F) AT 1,013 HPA

VAPOUR DENSITY: 3.6 AT 25 DEG. C (77 DEG. F) (AIR = 1.0)

EVAPORATION RATE: >1 (CCL4=1.0)


SECTION 10. STABILITY AND REACTIVITY 


CONDITIONS TO AVOID: AVOID OPEN FLAMES AND HIGH TEMPERATURES.

INCOMPATIBILITY:
INCOMPATIBLE PRODUCTS
ALKALI METALS ALKALINE EARTH METALS, POWDERED METALS, POWDERED METAL SALTS

HAZARDOUS DECOMPOSITION PRODUCTS:
DECOMPOSITION PRODUCTS ARE HAZARDOUS., THIS MATERIAL CAN BE DECOMPOSED
BY HIGH TEMPERATURES (OPEN FLAMES, GLOWING METAL SURFACES, ETC.) FORMING
HYDROFLUORIC ACID AND POSSIBLY CARBONYL FLUORIDE.

THESE MATERIALS ARE TOXIC AND IRRITATING., AVOID CONTACT WITH DECOMPOSITION
PRODUCTS

HAZARDOUS REACTIONS: POLYMERIZATION WILL NOT OCCUR.


SECTION 11. TOXICOLOGICAL INFORMATION 


DUPONT(TM) SUVA(R*) 134A AUTO:

FURTHER INFORMATION:
CARDIAC SENSITISATION THRESHOLD LIMIT: 312975 MG/M3
ANAESTHETIC EFFECTS THRESHOLD LIMIT: 834600 MG/M3

DID NOT SHOW CARCINOGENIC OR TERATOGENIC EFFECTS IN ANIMAL EXPERIMENTS.
INHALATION OF DECOMPOSITION PRODUCTS IN HIGH CONCENTRATION MAY CAUSE
SHORTNESS OF BREATH (LUNG OEDEMA).RAPID EVAPORATION OF THE LIQUID MAY
CAUSE FROSTBITE.

1,1,1,2-TETRAFLUOROETHANE:

DERMAL: NOT APPLICABLE

ORAL: NOT APPLICABLE

INHALATION 4 H LC50: 567000 PPM, RAT

INHALATION:
DOG
CARDIAC SENSITIZATION

SKIN IRRITATION:
SLIGHT IRRITATION, RABBIT

NOT EXPECTED TO CAUSE SKIN IRRITATION BASED ON EXPERT REVIEW OF THE
PROPERTIES OF THE SUBSTANCE.

NO SKIN IRRITATION, HUMAN

EYE IRRITATION:

SLIGHT IRRITATION, RABBIT

NOT EXPECTED TO CAUSE EYE IRRITATION BASED ON EXPERT REVIEW OF THE
PROPERTIES OF THE SUBSTANCE.

NO EYE IRRITATION, HUMAN

SKIN SENSITIZATION:
DID NOT CAUSE SENSITIZATION ON LABORATORY ANIMALS., GUINEA PIG NOT
EXPECTED TO CAUSE SENSITIZATION BASED ON EXPERT REVIEW OF THE PROPERTIES
OF THE SUBSTANCE.

DID NOT CAUSE SENSITIZATION ON LABORATORY ANIMALS. THERE ARE NO REPORTS
OF HUMAN RESPIRATORY SENSITIZATION.

REPEATED DOSE TOXICITY:
INHALATION:
RAT
NO TOXICOLOGICALLY SIGNIFICANT EFFECTS WERE FOUND.

CARCINOGENICITY:
OVERALL WEIGHT OF EVIDENCE INDICATES THAT THE SUBSTANCE IS NOT
CARCINOGENIC.

AN INCREASED INCIDENCE OF BENIGN TUMOURS WAS OBSERVED IN LABORATORY
ANIMALS.

MUTAGENICITY:
DID NOT CAUSE GENETIC DAMAGE IN ANIMALS.
DID NOT CAUSE GENETIC DAMAGE IN CULTURED MAMMALIAN CELLS.
DID NOT CAUSE GENETIC DAMAGE IN CULTURED BACTERIAL CELLS.

REPRODUCTIVE TOXICITY: ANIMAL TESTING SHOWED NO REPRODUCTIVE TOXICITY.

TERATOGENICITY:
ANIMAL TESTING SHOWED EFFECTS ON EMBRYO-FETAL DEVELOPMENT AT LEVELS EQUAL
TO OR ABOVE THOSE CAUSING MATERNAL TOXICITY.


SECTION 12. ECOLOGICAL INFORMATION 


AQUATIC TOXICITY:
1,1,1,2-TETRAFLUOROETHANE:

96 H LC50:
ONCORHYNCHUS MYKISS (RAINBOW TROUT): 450 MG/L

72 H EC50:
ALGAE: >118 MG/L
INFORMATION GIVEN IS BASED ON DATA OBTAINED FROM SIMILAR SUBSTANCES.

48 H EC50:
DAPHNIA MAGNA (WATER FLEA): 980 MG/L


SECTION 13. DISPOSAL CONSIDERATIONS 


WASTE DISPOSAL:
CAN BE USED AFTER RE-CONDITIONING. RECOVER BY DISTILLATION OR REMOVE TO A
PERMITTED WASTE DISPOSAL FACILITY. COMPLY WITH APPLICABLE FEDERAL,
STATE/PROVINCIAL AND LOCAL REGULATIONS.

ENVIRONMENTAL HAZARDS:
EMPTY PRESSURE VESSELS SHOULD BE RETURNED TO THE SUPPLIER.


SECTION 14. TRANSPORT INFORMATION 


DOT:
UN NUMBER: 3159
PROPER SHIPPING NAME: 1,1,1,2-TETRAFLUOROETHANE
CLASS: 2.2
LABELLING NO.: 2.2

IATA_C:
UN NUMBER: 3159
PROPER SHIPPING NAME: 1,1,1,2-TETRAFLUOROETHANE
CLASS: 2.2
LABELLING NO.: 2.2

IMDG:
UN NUMBER: 3159
PROPER SHIPPING NAME: 1,1,1,2-TETRAFLUOROETHANE
CLASS: 2.2
LABELLING NO.: 2.2


SECTION 15. REGULATORY INFORMATION 


SARA 313 REGULATED CHEMICAL(S):
SARA 313:
THIS MATERIAL DOES NOT CONTAIN ANY CHEMICAL COMPONENTS WITH KNOWN CAS
NUMBERS THAT EXCEED THE THRESHOLD (DE MINIMIS) REPORTING LEVELS
ESTABLISHED BY SARA TITLE III, SECTION 313.

CALIFORNIA PROP. 65:
CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS
OR ANY OTHER HARM: NONE KNOWN


SECTION 16. OTHER INFORMATION 


HMIS:
HEALTH                     1
FLAMMABILITY               0
REACTIVITY/PHYSICAL HAZARD 1

SUVA(R*) IS A REGISTERED TRADEMARK OF E. I. DU PONT DE NEMOURS AND COMPANY

BEFORE USE READ DUPONT'S SAFETY INFORMATION.

FOR FURTHER INFORMATION CONTACT THE LOCAL DUPONT OFFICE OR DUPONT'S
NOMINATED DISTRIBUTORS.

(R*) DUPONT'S REGISTERED TRADEMARK

THE INFORMATION PROVIDED IN THIS SAFETY DATA SHEET IS CORRECT TO THE BEST
OF OUR KNOWLEDGE, INFORMATION AND BELIEF AT THE DATE OF ITS PUBLICATION.
THE INFORMATION GIVEN IS DESIGNED ONLY AS A GUIDANCE FOR SAFE HANDLING,
USE, PROCESSING, STORAGE, TRANSPORTATION, DISPOSAL AND RELEASE AND IS NOT
TO BE CONSIDERED A WARRANTY OR QUALITY SPECIFICATION. THE INFORMATION
RELATES ONLY TO THE SPECIFIC MATERIAL DESIGNATED AND MAY NOT BE VALID FOR
SUCH MATERIAL USED IN COMBINATION WITH ANY OTHER MATERIALS OR IN ANY
PROCESS, UNLESS SPECIFIED IN THE TEXT.

SIGNIFICANT CHANGE FROM PREVIOUS VERSION IS DENOTED WITH A DOUBLE BAR.