Common Name: TUNGSTEN HALOGEN LAMPS
Manufacturer: WESTINGHOUSE LIGHTING
SDS Revision Date: 2/16/2009
SDS Format: No Format Specified
   
Item Number(s): 2CUZ5, 2CUZ6, 2CUZ7, 2CUZ8, 2CUZ9, 2CVA1, 2CVA2, 2CVA3, 2CVA4, 2CVA5, 2CVA6, 2CVA7, 2CVA8, 2CVA9, 2CVB1, 2CVB2, 2CVB3, 2CVB4, 2CVB6, 2CVB7, 2CVB8, 2CVB9, 2PGW8, 2PGW9, 2PGX1, 2PGX2, 2PGX3, 2PGX4, 2PGX5, 2PGX6, 2PGX7, 2PGX8, 4RZZ5, 4RZZ6, 4RZZ8, 4RZZ9, 4TAA1, 4TAA3, 4TAA5, 4TAA6, 4TAA8, 4TAC1, 4TAC2, 4TAC4, 4TAC7
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
PRODUCT AND COMPANY IDENTIFICATION 
HAZARDOUS INGREDIENTS 
CHEMICAL/PHYSICAL DATA 
FIRE AND EXPLOSION DATA 
REACTIVITY DATA 
EMERGENCY FIRST AID 
PRECAUTIONS FOR SAFE HANDLING AND USE 
CONTROL MEASURES 



W
WESTINGHOUSE

TUNGSTEN HALOGEN LAMP

MATERIAL SAFETY DATA SHEET (MSDS)

TUNGSTEN HALOGEN LAMPS

INFORMATION AND APPLICABILITY:
WESTINGHOUSE LIGHTING CORPORATION BELIEVES THAT UNDER THE OCCUPATIONAL
SAFETY AND HEALTH ADMINISTRATION (OSHA) HAZARDS COMMUNICATIONS STANDARD,
A LAMP (LIGHT BULB) IS EXEMPTED AS AN "ARTICLE" SO IT DOES NOT REQUIRE AN
MSDS. THE ORIGINAL OSHA STANDARD DEFINED AN ARTICLE AS SOMETHING THAT:
1) IS FORMED TO A SPECIFIC SHAPE AND DESIGN 2) HAS END USE FUNCTIONS
DEPENDENT UPON ITS SHAPE AND DESIGN, AND 3) DOES NOT RELEASE OR OTHERWISE
RESULT IN AN EXPOSURE TO A HAZARDOUS CHEMICAL UNDER NORMAL
CONDITIONS OF USE.

IN FEBRUARY, 1994, OSHA AMENDED THE HAZARD COMMUNICATION STANDARD AND
MODIFIED PART 3 OF THE ABOVE TO READ:
3) DOES NOT RELEASE MORE THAN VERY SMALL QUANTITIES OF A HAZARDOUS CHEMICAL
UNDER NORMAL CONDITIONS OF USE. STATE AND LOCAL REGULATIONS ALSO CONTAIN
SIMILAR EXEMPTIONS FOR SUCH ARTICLES.

HAZARDOUS MATERIALS ARE NOT RELEASED DURING NORMAL USE AND OPERATION OF
THESE LAMPS.


PRODUCT AND COMPANY IDENTIFICATION 


MANUFACTURER:
WESTINGHOUSE LIGHTING CORPORATION
12401 MCNULTY ROAD
PHILADELPHIA, PA 19154
1-800-248-6900.


HAZARDOUS INGREDIENTS 


THERE ARE NO KNOWN HEALTH HAZARDS FROM EXPOSURE TO LAMPS THAT ARE INTACT.
IF LAMP IS BROKEN, SOME OF THE FOLLOWING MATERIALS MAY BE RELEASED:

CHEMICAL NAME      CAS NUMBER    % BY WT.     EXPOSURE LIMITS IN AIR
                                              (MG/CUBIC M)
                                              ACGIH (TLV)     OSHA (PEL)

HYDROGEN BROMIDE   10035-10-6       0-<1.0    10.0 CEILING    10.0

METHYL BROMIDE        74-83-9       0-<1.0    20.0            80.0 CEILING

(1) METHYL IODIDE     74-88-4       0-<0.05   10.0            28.0

TUNGSTEN            7440-33-7    0.05-1.0

(INSOLUBLE                                    5.0
COMPOUNDS)

MOLYBDENUM          7439-98-7    0.02-1.0

(INSOLUBLE                                    10              15
COMPOUNDS)

GLASS(ALKALINE                      0-95      10 (2)          15 (2)
EARTH
ALUMINOSILICATE)

QUARTZ. FUSED      60676-86-0       0-95      0.1 RESP. DUST  0.1

(1) THESE CHEMICALS ARE SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION
313 OF TITLE III OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF
1986 AND 40 CFR PART 372.

(2) LIMITS AS NUISANCE PARTICULATE.


CHEMICAL/PHYSICAL DATA 


NOT APPLICABLE TO INTACT LAMP.


FIRE AND EXPLOSION DATA 


FLAMMABILITY: NON-COMBUSTIBLE

FIRE EXTINGUISHING MATERIALS:
USE EXTINGUISHING AGENTS SUITABLE FOR SURROUNDING FIRE.

SPECIAL FIREFIGHTING PROCEDURE:
USE A SELF-CONTAINED BREATHING APPARATUS TO PREVENT INHALATION OF DUST
AND/OR FUMES THAT MAY BE GENERATED FROM BROKEN LAMPS DURING FIREFIGHTING
ACTIVITIES.

UNUSUAL FIRE AND EXPLOSION HAZARDS:
WHEN EXPOSED TO HIGH TEMPERATURE, TOXIC FUMES MAY BE RELEASED FROM BROKEN
LAMPS.


REACTIVITY DATA 


STABILITY: LAMP IS STABLE.

CONDITIONS TO AVOID: NONE FOR INTACT LAMPS

INCOMPATIBILITY (MATERIALS TO AVOID): NONE FOR INTACT LAMPS

HAZARDOUS DECOMPOSITION PRODUCTS: NONE FOR INTACT LAMPS

HAZARDOUS POLYMERIZATION PRODUCTS: WILL NOT OCCUR.

HEALTH CONCERNS:
THERE ARE NO KNOWN HEALTH HAZARDS FROM EXPOSURE TO LAMPS THAT ARE INTACT.
NO ADVERSE EFFECTS ARE EXPECTED FROM OCCASIONAL EXPOSURE TO BROKEN LAMPS.
AS A MATTER OF GOOD PRACTICE, AVOID PROLONGED OR FREQUENT EXPOSURE TO
BROKEN LAMPS UNLESS THERE IS ADEQUATE VENTILATION. THE MAJOR HAZARD FROM
BROKEN LAMPS IS THE POSSIBILITY OF BEING CUT BY THE BROKEN GLASS.

EFFECTS OF OVEREXPOSURE TO BROKEN LAMPS BY INHALATION, INGESTION, OR
CONTACT (SKIN OR EYE):

HYDROGEN BROMIDE:
SHORT-TERM EXPOSURE TO HYDROGEN BROMIDE MAY CAUSE IRRITATION OF THE EYES,
NOSE AND THROAT. IT WILL CAUSE A BURN WHEN A SOLUTION IS SPLASHED ONTO SKIN
OR INTO EYES. REPEATED OR PROLONGED EXPOSURE TO HYDROGEN BROMIDE MAY CAUSE
IRRITATION OF THE NOSE AND THROAT WITH MUCOUS PRODUCTION AND INDIGESTION.

METHYL BROMIDE:
SHORT-TERM EXPOSURE TO METHYL BROMIDE MAY CAUSE HEADACHE, DIZZINESS,
NAUSEA, VOMITING, BLURRED VISION, SLURRED SPEECH, AND CONVULSIONS. HIGH
CONCENTRATIONS MAY ALSO CAUSE UNCONSCIOUSNESS AND DEATH. HIGH
CONCENTRATIONS MAY ALSO CAUSE LUNG IRRITATION RESULTING IN CONGESTION WITH
COUGHING, CHEST PAINS, AND SHORTNESS OF BREATH; KIDNEY DAMAGE IS ALSO
POSSIBLE. LUNG EFFECTS MAY BE DELAYED IN ONSET. PROLONGED OR REPEATED
EXPOSURE TO METHYL BROMIDE MAY CAUSE A VARIETY OF SYMPTOMS DUE TO INJURY TO
THE CENTRAL NERVOUS SYSTEM; INCLUDING VISUAL DISTURBANCES, SLURRED SPEECH,
NUMBNESS OF LIMBS, CONFUSION, SHAKING, AND UNCONSCIOUSNESS.

METHYL IODIDE:
EXPOSURE TO METHYL IODIDE MAY CAUSE NAUSEA AND VOMITING, DIARRHEA,
DIZZINESS, SLURRED SPEECH, VISUAL DISTURBANCES, STAGGERING, SHAKING,
IRRITABILITY, DROWSINESS, COMA, AND DEATH. IT MAY IRRITATE THE EYES AND
LUNGS. PROLONGED EXPOSURE TO METHYL IODIDE MAY CAUSE SKIN IRRITATION.

QUARTZ FUSED:
FIBROSIS OF THE LUNGS CAUSING SHORTNESS OF BREATH AND COUGHING HAS BEEN
ASSOCIATED WITH SILICA EXPOSURE.

GLASS:
GLASS DUST IS CONSIDERED TO BE PHYSIOLOGICALLY INERT AND AS SUCH HAS AN
OSHA EXPOSURE LIMIT OF 15 MG/CUBIC METER FOR TOTAL DUST AND 5 MG/CUBIC
METER FOR RESPIRABLE DUST.

TUNGSTEN:
INHALATION OF DUST MAY CAUSE MILD IRRITATION OF NOSE AND THROAT. CONTACT
MAY CAUSE MECHANICAL IRRITATION OF SKIN AND EYES

MOLYBDENUM:
OXIDES HAVE CAUSED IRRITATION TO THE EYES, NOSE, AND THREAT; WEIGHT LOSS
AND DIGESTIVE DISTURBANCES IN EXPERIMENTAL ANIMALS.


EMERGENCY FIRST AID 


GLASS CUTS:
PERFORM NORMAL FIRST AID PROCEDURES. SEEK MEDICAL ATTENTION AS REQUIRED.

INHALATION:
IF DISCOMFORT, IRRITATION OR SYMPTOMS OF PULMONARY INVOLVEMENT DEVELOP,
REMOVE FROM EXPOSURE AND SEEK MEDICAL ATTENTION.

INGESTION:
IN THE UNLIKELY EVENT OF INGESTING A LARGE QUANTITY OF MATERIAL, SEEK
MEDICAL ATTENTION IMMEDIATELY.

CONTACT SKIN:
THOROUGHLY WASH AFFECTED AREA WITH MILD SOAP OR DETERGENT AND WATER AND
PREVENT FURTHER CONTACT. SEEK MEDICAL ATTENTION AS NEEDED.

CONTACT EYE:
WASH EYES, INCLUDING UNDER EYELIDS, IMMEDIATELY WITH COPIOUS AMOUNT OF
WATER FOR 15 MINUTES. SEEK MEDICAL ATTENTION.

CARCINOGENIC ASSESSMENT (NTP ANNUAL REPORT. IARC MONOGRAPHS, OTHER): NONE


PRECAUTIONS FOR SAFE HANDLING AND USE 


IF LAMPS ARE BROKEN, VENTILATE AREA WHERE BREAKAGE OCCURRED. CLEAN-UP BY
VACUUMING OR OTHER METHOD THAT AVOIDS DUST GENERATION. TAKE USUAL
PRECAUTIONS FOR COLLECTION OF BROKEN GLASS. PLACE MATERIALS IN CLOSED
CONTAINERS TO AVOID GENERATING DUST.

IT IS THE RESPONSIBILITY OF THE WASTE GENERATOR TO ENSURE PROPER
CLASSIFICATION OF WASTE PRODUCTS. TO THAT END, TCLP TESTS SHOULD BE
CONDUCTED ON ALL WASTE PRODUCTS, INCLUDING THIS ONE, TO DETERMINE THE
ULTIMATE DISPOSITION IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND
LOCAL REGULATIONS.


CONTROL MEASURES 


VENTILATION:
USE ADEQUATE GENERAL AND LOCAL EXHAUST VENTILATION TO MAINTAIN EXPOSURE
LEVELS BELOW THE PEL OR TLV LIMITS. IF SUCH VENTILATION IS UNAVAILABLE,
USE RESPIRATORS AS SPECIFIED BELOW.

RESPIRATORY PROTECTION:
USE APPROPRIATE NIOSH APPROVED RESPIRATOR IF AIRBORNE DUST CONCENTRATIONS
EXCEED THE PERTINENT PEL OR TLV LIMITS. ALL APPROPRIATE REQUIREMENTS SET
FORTH IN 29 CFR 1910.134 SHOULD BE MET.

EYE PROTECTION:
OSHA SPECIFIED SAFETY GLASSES, GOGGLES OR FACE SHIELD ARE RECOMMENDED FOR
DEALING WITH BROKEN LAMPS.

PROTECTIVE CLOTHING:
OSHA SPECIFIED GLOVES ARE RECOMMENDED FOR DEALING WITH BROKEN LAMPS.

HYGIENIC PRACTICES:
AFTER HANDLING BROKEN LAMPS, WASH THOROUGHLY BEFORE EATING, SMOKING OR
USING TOILET FACILITIES.

ISSUE DATE: FEBRUARY 16, 2009

CALL 1-800-999-2226 OR VISIT WWW.WESTINGHOUSELIGHTING.COM

WESTINGHOUSE LIGHTING CORPORATION
PHILADELPHIA, PA 19154-1029
U.S.A.

WESTINGHOUSE LIGHTING CORPORATION, A WESTINGHOUSE ELECTRIC CORPORATION
LICENSEE

W
"WESTINGHOUSE" AND "YOU CAN BE SURE...IF IT'S WESTINGHOUSE" ARE ALL
REGISTERED TRADEMARKS OF WESTINGHOUSE ELECTRIC CORPORATION

YOU CAN BE SURE...IF IT'S WESTINGHOUSE
W

(C)2012 WESTINGHOUSE LIGHTING CORPORATION/WLC/1012/102342