Common Name: SEALED LEAD ACID BATTERY
Manufacturer: FIRSTPOWER TECHNOLOGY CHINA
SDS Revision Date: 1/5/2013
SDS Format: No Format Specified
   
Item Number(s): 15Y007, 15Y008, 15Y011, 15Y026, 15Y027, 15Y028, 15Y029, 15Y030, 15Y031, 15Y032, 15Y033, 15Y034, 15Y035, 15Y036, 15Y037, 15Y038, 15Y039, 15Y040, 15Y041, 15Y042, 15Y043, 15Y044, 15Y045, 15Y046, 15Y047, 1VAP3, 26WC24, 5PVN6, 5PVN8, 5YNJ0, 5YNJ1
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 
SECTION 2: HAZARDS IDENTIFICATION 
SECTION 3: COMPOSITION / INFORMATION ON INGREDIENTS 
SECTION 4: FIRST AID PROCEDURES 
SECTION 5: FIRE FIGHTING MEASURES 
SECTION 6: ACCIDENTAL RELEASE MEASURES 
SECTION 7: HANDLING AND STORAGE 
SECTION 8: EXPOSURE CONTROLS / PERSONAL PROTECTION 
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10: CHEMICAL STABILITY AND REACTIVITY INFORMATION 
SECTION 11: TOXICOLOGICAL INFORMATION 
SECTION 12: ECOLOGICAL INFORMATION 
SECTION 13: DISPOSAL CONSIDERATIONS 
SECTION 14: TRANSPORTATION INFORMATION 
SECTION 15: REGULATORY INFORMATION 
SECTION 16: OTHER INFORMATION 



MATERIAL SAFETY DATA SHEET


SECTION 1: CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 


UPDATED: JAN. 5, 2013

UN NO.: 2800

CHEMICAL/TRADE NAME (AS USED ON LABEL): SEALED LEAD ACID BATTERY

CHEMICAL FAMILY/CLASSIFICATION: ELECTRIC STORAGE BATTERY

MANUFACTURER'S NAME: FIRSTPOWER TECHNOLOGY CO, LTD

ADDRESS:
RM,L,M&N,15/F,BUILDING A
FORTUNE PLAZA
SHENZHEN, 518034
CHINA

CONTACT:
FIRSTPOWER SAFETY DEPARTMENT: 0086-755-83021393


SECTION 2: HAZARDS IDENTIFICATION 


PRODUCT CONTAINS TOXIC CHEMICALS THAT ARE SUBJECT TO THE REPORTING
REQUIREMENTS OF SECTION 302 AND 313 OF THE EMERGENCY PLANNING AND
COMMUNITY RIGHT-TO-KNOW ACT OF 1986).


SECTION 3: COMPOSITION / INFORMATION ON INGREDIENTS 


EXPOSURE LIMITS:

MATERIAL      % BY WT.   CAS NUMBER     AIR EXPOSURE LIMITS ((MICRO)G/M3)
                                        OSHA       AGGIH       NIOSH

LEAD          57         7439-92-1      50         150         100

LEAD OXIDE    22         1309-60-0      50         150         100

ELECTROLYTE   14         7664-93-9      1          1           1
(SULFURIC
ACID)


SECTION 4: FIRST AID PROCEDURES 


INHALATION:
REMOVE FROM EXPOSURE AND APPLY OXYGEN IF BREATHING IS DIFFICULT.

SKIN: WASH WITH PLENTY OF SOAP AND WATER. REMOVE ANY CONTAMINATED CLOTHING.

EYES:
FLUSH WITH PLENTY OF WATER IMMEDIATELY FOR AT LEAST 15 MINUTES. CONSULT A
PHYSICIAN.

INGESTION: CONSULT A PHYSICIAN IMMEDIATELY.


SECTION 5: FIRE FIGHTING MEASURES 


FLASH POINT:
HYDROGEN: 259 DEG. C

AUTO IGNITION TEMPERATURE:
HYDROGEN: 580 DEG. C

EXTINGUISHING MEDIA: DRY CHEMICAL, FOAM, CO2

UNUSUAL FIRE AND EXPLOSION HAZARDS:
HYDROGEN AND OXYGEN GASES ARE PRODUCED IN THE CELLS DURING NORMAL BATTERY
OPERATION (HYDROGEN IS FLAMMABLE AND OXYGEN SUPPORTS COMBUSTION).
THESE GASES ENTER THE AIR THROUGH THE VENT CAPS. TO AVOID THE CHANCE OF A
FIRE OR EXPLOSION, KEEP SPARKS AND OTHER SOURCES OF IGNITION AWAY FROM THE
BATTERY.


SECTION 6: ACCIDENTAL RELEASE MEASURES 


A.:
REMOVE COMBUSTIBLE MATERIALS AND ALL SOURCES OF IGNITION. COVER SILLS WITH
SODA ASH (SODIUM CARBONATE) OR QUICKLIME (CALCIUM OXIDE). MIX WELL. MAKE
CERTAIN MIXTURE IS NEUTRAL THEN COLLECT RESIDUE AND PLACE IN A DRUM OR
OTHER SUITABLE CONTAINER. DISPOSE OF A HAZARDOUS WASTE.

B.:
WEAR ACID-RESISTANT BOOTS, CHEMICAL FACE SHIELD, CHEMICAL SPLASH GOGGLES,
AND ACID-RESISTANT GLOVES.

DO NOT RELEASE UN-NEUTRALIZED ACID.


SECTION 7: HANDLING AND STORAGE 


HYGIENE PRACTICES:
FOLLOWING CONTACT WITH INTERNAL BATTERY COMPONENTS, WASH HAND THOROUGHLY
BEFORE EATING, DRINKING, OR SMOKING.

RESPIRATORY PROTECTION:
WEAR SAFETY GLASSES. DO NOT PERMIT FLAMES OR SPARKS IN THE VICINITY OF
BATTERY(S). IF BATTERY ELECTROLYTE (ACID) COMES IN CONTACT WITH CLOTHING,
DISCARD CLOTHING.

OTHER HANDLING AND STORAGE PRECAUTIONS: NONE REQUIRED.


SECTION 8: EXPOSURE CONTROLS / PERSONAL PROTECTION 


ENGINEERING CONTROLS:
STORE LEAD/ACID BATTERIES WITH ADEQUATE VENTILATION. ROOM VENTILATION IS
REQUIRED FOR BATTERIES UTILIZED FOR STANDBY POWER GENERATION. NEVER
RECHARGE BATTERIES IN AN UNVENTILATED, ENCLOSED SPACE.

WORK PRACTICES:
DO NOT REMOVE VENT CAPS. FOLLOW SHIPPING AND HANDLING INSTRUCTIONS THAT ARE
APPLICABLE TO THE BATTERY TYPE. TO AVOID DAMAGE TO TERMINALS AND SEALS, DO
NOT DOUBLE-STACK INDUSTRIAL BATTERIES.

RESPIRATORY PROTECTION:
NONE REQUIRED UNDER NORMAL HANDLING CONDITIONS. DURING BATTERY FORMATION
(HIGH-RATE CHARGE CONDITION), ACID MIST CAN BE GENERATED WHICH MAY CAUSE
RESPIRATORY IRRITATION. ALSO, IF ACID SPILLAGE OCCURS IN A CONFINED SPACE,
EXPOSURE MAY OCCUR. IF IRRITATION OCCURS, WEAR A RESPIRATOR SUITABLE FOR
PROTECTION AGAINST ACID MIST.

EYES AND FACE:
CHEMICAL SPLASH GOGGLES ARE PREFERRED. ALSO ACCEPTABLE ARE "VISOR-GOGS"
OR A CHEMICAL FACE SHIELD WORN OVER SAFETY GLASSES.

HANDS, ARMS, BODY:
VINYL COATED, VC, GAUNTIET TYPE GLOVES WITH ROUGH FINISH ARE PREFERRED.

OTHER SPECIAL CLOTHING AND EQUIPMENT:
SAFETY SHOES ARE RECOMMENDED WHEN HANDLING BATTERIES. ALL FOOTWEAR MUST
MEET REQUIREMENTS OF


SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES 


MATERIAL IS SOLID AT NORMAL TEMPERATURES.

ELECTROLYTE:

BOILING POINT: 230 DEG. F / 110 DEG. C

MELTING POINT: LEAD 327.4 DEG. C

SPECIFIC GRAVITY: 1.215 - 1.350

VAPOR DENSITY: NOT DETERMINED

% VOLATILES BY WEIGHT: NOT APPLICABLE

VAPOR PRESSURE: NOT DETERMINED

SOLUBILITY IN WATER: 100% (ELECTROLYTE)

EVAPORATION RATE: NOT DETERMINED

APPEARANCE AND ODOR: ELECTROLYTE IS A CLEAR LIQUID WITH A ACIDIC ODOR


SECTION 10: CHEMICAL STABILITY AND REACTIVITY INFORMATION 


STABILITY: STABLE

CONDITIONS TO AVOID: SPARKS AND OTHER SOURCES OF IGNITION

INCOMPATIBILITY (MATERIALS TO AVOID):

1. LEAD/LEAD COMPOUNDS:
POTASSIUM, CARBIDES, SULFIDES, PEROXIDES, PHOSPHORUS, SULFUR.

2. BATTERY ELECTROLYTE (ACID):
COMBUSTIBLE MATERIALS, STRONG REDUCING AGENTS, MOST METALS, CARBIDES,
ORGANIC MATERIALS, CHLORATES, NITRATES, PICRATES, AND FULMINATES.

HAZARDOUS DECOMPOSITION PRODUCTS:

1. LEAD/LEAD COMPOUNDS: OXIDES OF LEAD AND SULFUR.

2. BATTERY ELECTROLYTE (ACID):
HYDROGEN, SULFUR DIOXIDE, AND SULFUR TRIOXIDE.

CONDITIONS TO AVOID:
HIGH TEMPERATURE. BATTERY ELECTROLYTE (ACID) WILL REACT WITH WATER TO
PRODUCE HEAT. CAN REACT WITH OXIDIZING OR REDUCING AGENTS.


SECTION 11: TOXICOLOGICAL INFORMATION 


UNDER NORMAL OPERATING CONDITIONS, THE INTERNAL MATERIAL WILL NOT BE
HAZARDOUS TO YOUR HEALTH. ONLY INTERNALLY EXPOSED MATERIAL DURING
PRODUCTION OR CASE BREAKAGE OR EXTREME HEAT (FIRE) MAY BE HAZARDOUS TO
YOUR HEALTH.

ROUTES OF ENTRY:

INSTALLATION:
ACID MIST FROM FORMATION PROCESS MAY CAUSE RESPIRATORY IRRITATION.

SKIN CONTACT: ACID MAY CAUSE IRRITATION, BURNS AND/OR ULCERATION.

SKIN ABSORPTION: NOT A SIGNIFICANT ROUTE OF ENTRY.

EYE CONTACT:
ACID MAY CAUSE SEVER IRRITATION, BURNS, CORNEA DAMAGE AND/OR BLINDNESS.

INGESTION:
ACID MAY CAUSE IRRITATION OF MOUTH, THROAT, ESOPHAGUS AND STOMACH.

SIGN AND SYMPTOMS OF OVER EXPOSURE:

ACUTE EFFECTS:
OVER EXPOSURE TO LEAD MAY LEAD TO LOSS OF APPETITE, CONSTIPATION,
SLEEPLESSNESS AND FATIGUE. OVER EXPOSURE TO ACID MAY LEAD TO SKIN
IRRITATION, CORNEAL DAMAGE OF THE EYES AND UPPER RESPIRATORY SYSTEM.

CHRONIC EFFECTS:
LEAD AND ITS COMPONENTS MAY CAUSE DAMAGE TO KIDNEYS AND NERVOUS SYSTEM.
ACID AND ITS COMPONENTS MAY CAUSE LUNG DAMAGE AND PULMONARY CONDITIONS.

POTENTIAL TO CAUSE CANCER:
THE INTERNATIONAL AGENCY FOR RESEARCH ON CANCER HAS CLASSIFIED "STRONG
INORGANIC ACID MIST CONTAINING SULFURIC ACID" AS A CATEGORY 1 CARCINOGEN,
A SUBSTANCE THAT IS CARCINOGENIC TO HUMANS. THIS CLASSIFICATION DOES NOT
APPLY TO LIQUID FORMS OF SULFURIC ACID OR SULFURIC ACID SOLUTIONS
CONTAINED WITHIN A BATTERY. INORGANIC ACID MIST IS NOT GENERATED UNDER
NORMAL USE OF THIS PRODUCT. MISUSE OF THE PRODUCT, SUCH AS OVERCHARGING,
MAY HOWEVER RESULT IN THE GENERATION OF SULFURIC ACID MIST.


SECTION 12: ECOLOGICAL INFORMATION 


CALIFORNIA PROPOSITION 65:
THE STATE OF CALIFORNIA HAS DETERMINED THAT CERTAIN BATTERY TERMINALS AND
RELATED ACCESSORIES CONTAIN LEAD AND LEAD COMPOUNDS, CHEMICALS KNOWN TO THE
STATE OF CALIFORNIA TO CAUSE CANCER AND REPRODUCTIVE HARM.

WARMING: WASH HANDS THOROUGHLY AFTER HANDLING BATTERIES.


SECTION 13: DISPOSAL CONSIDERATIONS 


WASTE DISPOSAL METHOD:

BATTERY ELECTROLYTE (ACID):
NEUTRALIZE AS ABOVE FOR A SPILL, COLLECT RESIDUE, AND PLACE IN A DRUM OR
SUITABLE CONTAINER. DISPOSE OF AS HAZARDOUS WASTE. DO NOT FLUSH LEAD
CONTAMINATED ACID TO SEWER.

BATTERIES:
SEND TO LEAD SMELTER FOR RECLAMATION FOLLOWING APPLICABLE FEDERAL, STATE
AND LOCAL REGULATIONS. PRODUCT CAN BE RECYCLED ALONG WITH AUTOMOTIVE (SLI)
LEAD ACID BATTERIES.


SECTION 14: TRANSPORTATION INFORMATION 


TO TRANSPORT THESE BATTERIES AS "NON-SPILLABLE" THEY MUST BE SHIPPED IN A
CONDITION THAT WOULD PROTECT THEM FROM SHORT-CIRCUITS AND BE SECURELY
PACKAGED SO AS TO WITH STAND CONDITIONS NORMAL TO TRANSPORTATION BY A
CONSUMER, IN OR OUT OF A DEVICE, THEY ARE UNREGULATED THUS REQUIRING NO
ADDITIONAL SPECIAL HANDLING OR PACKAGING AND BATTERIES IS PACKED TO COMPLY
WITH IMDG DG SPECIAL PROVISION


SECTION 15: REGULATORY INFORMATION 


PROPER SHIPPING NAME: BATTERIES, NON-SPILLABLE, ELECTRIC STORAGE

U. S. DOT(US DEPARTMENT OF TRANSPORTATION):
UNREGULATED, MEETS THE REQUIREMENT OF 49 CFR 173.159(D)

IATA (INTERNATIONAL AIR TRANSPORTATION ASSOCIATION)/ ICAO (INTERNATIONAL
CIVIL AVIATION ADMINISTRATION):
UNREGULATED, MEETS THE REQUIREMENTS OF SPECIAL REVISIONS A67

IMO (INTERNATIONAL MARITIME DANGEROUS GOODS): UNREGULATED


SECTION 16: OTHER INFORMATION 


FIRSTPOWER SEAL LEAD-ACID BATTERIES ARE CLASSIFIED AS "NON-SPILLABLE" FOR
THE PURPOSE OF TRANSPORTATION BY DOT, AND IATA/ICAO AS RESULT OF PASSING
THE VIBRATION AND PRESSURE DIFFERENTIAL TEST DESCRIBED IN DOT[49 CFR
173.159(D) AND IATA/ICAO [SPECIAL PROVISION A67].

FIRSTPOWER SEAL LEAD-ACID BATTERIES CAN BE SAFELY TRANSPORTED ON DECK, OR
UNDER DECK STORED ON EITHER A PASSENGER OR CARGO VESSEL AS RESULT OF
PASSING THE VIBRATION AND PRESSURE DIFFERENTIAL TESTS AS DESCRIBED IN THE
REGULATIONS.