Common Name: LEAD / ACID BATTERY
Manufacturer: TROJAN BATTERY
SDS Revision Date: 1/9/2013
SDS Format: ANSI-OSHA
   
Item Number(s): 12R946, 12R947, 12R948, 12R949, 12R950, 12R951, 12R952, 12R953, 12R954, 12R955, 12R956, 12R957, 12R958, 14X831, 14X832, 18F650, 18F651, 18F652, 18F653, 18F654, 1AAT1, 21ML57, 21ML58, 2FV46, 2FV48, 2FV50, 2FV51, 31YA62, 31YA63, 31YA64, 31YA65, 48K605, 48K609, 49H330, 49H331, 49H332, 49H333, 49H339, 49H340, 4NEL8, 4VDL6, 4VDL7, 4VDL8, 4VDL9, 4VDN1, 4VDN2, 4VDN3, 4VDN4, 4VDN5, 4VDN6, 4VDN7, 4VDN8, 4VDN9, 4VDP1, 4VDP2, 4VDP3, 4VDP4, 4VDP5, 4VDP6, 4VDP7, 4VDP8, 4VDP9, 4VDR1, 4VDR2, 4VDR4, 4VDR5, 4VDR6, 4VDR7, 4VDR8, 4VDR9, 4VDT1, 4VDT2, 4VDT7, 4VDT8, 4VDT9, 4VDW5, 4VDW6, 4VDW7, 4VDW8, 4VDW9, 4VDX2, 5281571, 5PFT4, 6029862, 6DHH6
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 
SECTION 2 - COMPOSITION/INFORMATION ON INGREDIENTS 
SECTION 3 - HAZARD IDENTIFICATION 
SECTION 4 - FIRST AID MEASURES 
SECTION 5 - FIREFIGHTING MEASURES 
SECTION 6 - ACCIDENTAL RELEASE MEASURES 
SECTION 7 - HANDLING AND STORAGE 
SECTION 8 - EXPOSURE CONTROLS AND PERSONAL PROTECTION 
SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10 - STABILITY AND REACTIVITY 
SECTION 11 - TOXICOLOGICAL INFORMATION 
SECTION 12 - ECOLOGICAL INFORMATION 
SECTION 13 - DISPOSAL CONSIDERATIONS 
SECTION 14 - TRANSPORT INFORMATION 
SECTION 15 - REGULATORY INFORMATION 
SECTION 16 - OTHER INFORMATION 



TROJAN(R*)
BATTERY COMPANY

TROJAN BATTERY COMPANY

LEAD / ACID BATTERY

HAZARD RATING:

NFPA:
H 3
F 1
R 2
CO

MATERIAL SAFETY DATA SHEET


SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION 


MANUFACTURER'S NAME: TROJAN BATTERY COMPANY

ADDRESS:
12380 CLARK ST.
SANTA FE SPRINGS, CA 90670

EMERGENCY TELEPHONE NO.:
CHEMTREC: (800) 424-9300
INTERNATIONAL: (703) 527-3887

OTHER INFORMATION CALLS:
562-236-3000
800-423-6569

REVISION DATE: JANUARY 09, 2013

PERSON RESPONSIBLE FOR PREPARATION: ISMAEL PEDROZA, JR. - DIRECTOR OF EH&S


SECTION 2 - COMPOSITION/INFORMATION ON INGREDIENTS 


C.A.S.        PRINCIPAL HAZARDOUS  HAZARD      %          ACGIH     OSHA
              COMPONENT(S)         CATEGORY               TLV       PEL-TWA
              (CHEMICAL &
              COMMON NAME(S)

7439-92-1     LEAD/LEAD OXIDE/     ACUTE-       60 - 97%  0.05      0.05
              LEAD SULFATE         CHRONIC                MG/M3     MG/M3

7440-36-0     ANTIMONY             CHRONIC     1.5 - 4%   0.5       0.5
                                                          MG/M3     MG/M3

7440-38-2     ARSENIC              ACUTE-      <1%        0.01      0.01
                                   CHRONIC                MG/M3     MG/M3

7664-93-9     SULFURIC ACID        REACTIVE-    10 - 38%  1.0       1.0
              (BATTERY             OXIDIZER               MG/M3     MG/M3
              ELECTROLYTE)         ACUTE-
                                   CHRONIC

7440-70-2     CALCIUM              REACTIVE    <0.15%     NOT       NOT
                                                          ESTAB-    ESTAB-
                                                          LISHED    LISHED

7440-31-5     TIN                  CHRONIC     <0.3%      2.0       NOT
                                                          MG/M3     ESTAB-
                                                                    LISHED

NOTE:
PEL'S FOR INDIVIDUAL STATES MAY DIFFER FROM OSHA PEL'S. CHECK WITH LOCAL
AUTHORITIES FOR THE APPLICABLE STATE PEL'S.

OSHA - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
ACGIH - AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS
NIOSH - NATIONAL INSTITUTE FOR OCCUPATIONAL SAFETY AND HEALTH.

ALL TROJAN BATTERY MODELS DO NOT CONTAIN CADMIUM. TROJAN BATTERY MODELS:
T-105, T-125, T-145, T-875, T-1260, T-1275 DO NOT CONTAIN MERCURY.

COMMON NAME (USED ON LABEL) (TRADE NAME & SYNONYMS):
LEAD/ACID STORAGE BATTERY

CHEMICAL FAMILY: TOXIC AND CORROSIVE MATERIAL MIXTURE

CHEMICAL NAME: LEAD/ACID STORAGE BATTERY

FORMULA: LEAD AND ACID (ELECTROLYTE)


SECTION 3 - HAZARD IDENTIFICATION 


SIGNS AND SYMPTOMS OF EXPOSURE:

1. ACUTE HAZARDS:
DO NOT OPEN BATTERY. AVOID CONTACT WITH INTERNAL COMPONENTS. INTERNAL
COMPONENTS INCLUDE LEAD AND LIQUID ELECTROLYTE.

ELECTROLYTE:
ELECTROLYTE IS CORROSIVE AND CONTACT MAY CAUSE SKIN IRRITATION AND CHEMICAL
BURNS. ELECTROLYTE CAUSES SEVERE IRRITATION AND BURNS OF EYES, NOSE AND
THROAT. INGESTION CAN CAUSE SEVERE BURNS AND VOMITING.

LEAD:
DIRECT SKIN OR EYE CONTACT MAY CAUSE LOCAL IRRITATION. INHALATION OR
INGESTION OF LEAD DUST OR FUMES MAY RESULT IN HEADACHE, NAUSEA, VOMITING,
ABDOMINAL SPASMS, FATIGUE, SLEEP DISTURBANCES, WEIGHT LOSS, ANEMIA AND LEG,
ARM AND JOINT PAIN.

2. SUB-CHRONIC AND CHRONIC HEALTH EFFECTS:

ELECTROLYTE:
REPEATED CONTACT WITH SULFURIC ACID BATTERY ELECTROLYTE FLUID MAY CAUSE
DRYING OF THE SKIN WHICH MAY RESULT IN IRRITATION, DERMATITIS, AND SKIN
BURNS. REPEATED EXPOSURE TO SULFURIC ACID MIST MAY CAUSE EROSION OF TEETH,
CHRONIC EYE IRRITATION AND/OR CHRONIC INFLAMMATION OF THE NOSE, THROAT AND
LUNGS.

LEAD:
PROLONGED EXPOSURE MAY CAUSE CENTRAL NERVOUS SYSTEM DAMAGE,
GASTROINTESTINAL DISTURBANCES, ANEMIA, AND WRIST-DROP AND KIDNEY
DYSFUNCTION. PREGNANT WOMEN SHOULD BE PROTECTED FROM EXCESSIVE EXPOSURE
TO PREVENT LEAD FROM CROSSING THE PLACENTAL BARRIER AND CAUSING INFANT
NEUROLOGICAL DISORDERS.

CALIFORNIA PROPOSITION 65 WARNING:
BATTERY POSTS, TERMINALS, AND RELATED ACCESSORIES CONTAIN LEAD AND LEAD
COMPOUNDS, CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND
REPRODUCTIVE HARM, AND DURING CHARGING, STRONG INORGANIC ACID MISTS
CONTAINING SULFURIC ACID ARE EVOLVED, A CHEMICAL KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER. WASH HANDS AFTER HANDLING.

MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE:

IF BATTERY IS BROKEN OR MATERIAL IS SPILLED, THEN PERSONS WITH THE
FOLLOWING MEDICAL CONDITIONS MUST TAKE PRECAUTIONS:
PULMONARY EDEMA, BRONCHITIS, EMPHYSEMA, DENTAL EROSION AND
TRACHEOBRONCHITIS.

ROUTES OF ENTRY:
INHALATION: YES
EYE CONTACT: YES
INGESTION: YES
SKIN CONTACT: YES

CHEMICAL(S) LISTED AS CARCINOGEN OR POTENTIAL CARCINOGEN:
PROPOSITION 65: YES
NATIONAL TOXICOLOGY PROGRAM: YES
I.A.R.C. MONOGRAPHS: YES
OSHA: NO
EPA CAG: YES
NIOSH: YES


SECTION 4 - FIRST AID MEASURES 


EMERGENCY AND FIRST AID PROCEDURES:
CONTACT WITH INTERNAL COMPONENTS IF BATTERY IS OPENED, BROKEN OR SPILLED.

1. INHALATION:
REMOVE TO FRESH AIR AND PROVIDE MEDICAL OXYGEN/CPR IF NEEDED. OBTAIN
MEDICAL ATTENTION.

2. EYES:
IMMEDIATELY FLUSH WITH WATER FOR AT LEAST 15 MINUTES, HOLD EYELIDS OPEN.
OBTAIN MEDICAL ATTENTION.

3. SKIN:
FLUSH CONTACTED AREA WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
REMOVE CONTAMINATED CLOTHING AND OBTAIN MEDICAL ATTENTION IF NECESSARY.

4. INGESTION:
DO NOT INDUCE VOMITING. IF CONSCIOUS DRINK LARGE AMOUNTS OF WATER/MILK.
OBTAIN MEDICAL ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS
PERSON.


SECTION 5 - FIREFIGHTING MEASURES 


FLASH POINT: NOT APPLICABLE

FLAMMABLE LIMITS IN AIR % BY VOLUME (WHEN CHARGING): HYDROGEN (H2)
LOWER: 4.1%
UPPER: 74.2%

EXTINGUISHER MEDIA: CLASS ABC, CO2, HALON

AUTO-IGNITION TEMPERATURE: POLYPROPYLENE 675 DEG. F

SPECIAL FIRE FIGHTING PROCEDURES:
LEAD-ACID BATTERIES DO NOT BURN OR BURN WITH DIFFICULTY. DO NOT USE WATER
ON FIRES WHERE MOLTEN METAL IS PRESENT. EXTINGUISH FIRE WITH AGENT SUITABLE
FOR SURROUNDING COMBUSTIBLE MATERIALS. COOL EXTERIOR OF BATTERY IF EXPOSED
TO FIRE TO PREVENT RUPTURE. THE ACID MIST AND VAPORS GENERATED BY HEAT OR
FIRE ARE CORROSIVE. USE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS
(SCBA) AND FULL PROTECTIVE EQUIPMENT OPERATED IN POSITIVE-PRESSURE MODE.

UNUSUAL FIRE AND EXPLOSION HAZARDS:

HYDROGEN GAS AND SULFURIC ACID VAPORS ARE GENERATED UPON OVERCHARGE AND
POLYPROPYLENE CASE FAILURE. VENTILATE CHARGING AREAS AS PER ACGIH
INDUSTRIAL VENTILATION:
A MANUAL OF RECOMMENDED PRACTICE AND NATIONAL FIRE CODE, 1980 VOL. 1, P.
12, B-9, 10. HYDROGEN GAS MAY BE FLAMMABLE OR EXPLOSIVE WHEN MIXED WITH
AIR, OXYGEN, CHLORINE. AVOID OPEN FLAMES/SPARKS/OTHER SOURCES OF IGNITION
NEAR BATTERY. TO AVOID RISK OF FIRE OR EXPLOSION, KEEP SPARKS OR OTHER
SOURCES OF IGNITION AWAY FROM BATTERIES AND DO NOT ALLOW METALLIC MATERIALS
TO SIMULTANEOUSLY CONTACT NEGATIVE AND POSITIVE TERMINALS OF CELLS AND
BATTERIES. SULFURIC ACID REACTS VIOLENTLY WITH WATER/ORGANICS.


SECTION 6 - ACCIDENTAL RELEASE MEASURES 


PROCEDURES FOR CLEANUP:
STOP RELEASE, IF POSSIBLE. AVOID CONTACT WITH ANY SPILLED MATERIAL. CONTAIN
SPILL, ISOLATE HAZARD AREA, AND DENY ENTRY. LIMIT SITE ACCESS TO EMERGENCY
RESPONDERS. NEUTRALIZE WITH SODIUM BICARBONATE, SODA ASH, LIME OR OTHER
NEUTRALIZING AGENT. PLACE BATTERY IN SUITABLE CONTAINER FOR DISPOSAL.
DISPOSE OF CONTAMINATED MATERIAL IN ACCORDANCE WITH APPLICABLE LOCAL, STATE
AND FEDERAL REGULATIONS. SODIUM BICARBONATE, SODA ASH, SAND, LIME OR OTHER
NEUTRALIZING AGENT SHOULD BE KEPT ON-SITE FOR SPILL REMEDIATION.

PERSONAL PRECAUTIONS:
ACID RESISTANT APRONS, BOOTS AND PROTECTIVE CLOTHING. ANSI APPROVED SAFETY
GLASSES WITH SIDE SHIELDS/FACE SHIELD RECOMMENDED. VENTILATE ENCLOSED
AREAS.

ENVIRONMENTAL PRECAUTIONS:
LEAD AND ITS COMPOUNDS AND SULFURIC ACID CAN POSE A SEVERE THREAT TO THE
ENVIRONMENT. CONTAMINATION OF WATER, SOIL, AND AIR SHOULD BE PREVENTED.


SECTION 7 - HANDLING AND STORAGE 


PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE:
KEEP AWAY FROM FLAMES DURING AND IMMEDIATELY AFTER CHARGING. COMBUSTION OR
OVERCHARGING MAY CREATE OR LIBERATE TOXIC AND HAZARDOUS GASES AND LIQUIDS
INCLUDING HYDROGEN, SULFURIC ACID MIST, SULFUR DIOXIDE, SULFUR TRIOXIDE,
STIBINE, ARSINE AND SULFURIC ACID. STORE BATTERIES IN COOL, DRY, WELL
VENTILATED AREA. DO NOT SHORT CIRCUIT BATTERY TERMINALS, OR REMOVE VENT
CAPS DURING STORAGE OR RECHARGING. PROTECT BATTERY FROM PHYSICAL DAMAGE.

OTHER PRECAUTIONS:
GOOD PERSONAL HYGIENE AND WORK PRACTICES ARE MANDATORY. REFRAIN FROM
EATING, DRINKING OR SMOKING IN WORK AREAS. THOROUGHLY WASH HANDS, FACE,
NECK, AND ARMS BEFORE EATING, DRINKING OR SMOKING. LAUNDER SOILED CLOTHING
BEFORE REUSE. EMPTIED BATTERIES CONTAIN HAZARDOUS SULFURIC ACID RESIDUE.


SECTION 8 - EXPOSURE CONTROLS AND PERSONAL PROTECTION 


RESPIRATORY PROTECTION (SPECIFY TYPE):
ACID/GAS NIOSH APPROVED RESPIRATOR IS REQUIRED WHEN THE PEL IS EXCEEDED
OR EMPLOYEE EXPERIENCES RESPIRATORY IRRITATION. WHEN EXPOSURE LEVELS ARE
UNKNOWN OR WHEN FIREFIGHTING, WEAR A SELF-CONTAINED BREATHING APPARATUS
WITH A FULL FACE PIECE OPERATED IN A POSITIVE PRESSURE MODE.

VENTILATION:
MUST BE PROVIDED WHEN CHARGING IN AN ENCLOSED AREA. CHANGE AIR EVERY
15 MIN.

LOCAL EXHAUST: WHEN PEL IS EXCEEDED.

MECHANICAL (GENERAL):
NORMAL MECHANICAL VENTILATION RECOMMENDED FOR STATIONARY APPLICATIONS.

PROTECTIVE GLOVES:
WEAR RUBBER OR PLASTIC ACID RESISTANT GLOVES WITH ELBOW LENGTH GAUNTLET
WHEN FILLING BATTERIES.

EYE PROTECTION:
ANSI APPROVED SAFETY GLASSES WITH SIDE SHIELDS/FACE SHIELD RECOMMENDED.
SAFETY GOGGLES.

OTHER PROTECTIVE CLOTHING OR EQUIPMENT:
VENTILATION AS DESCRIBED IN THE INDUSTRIAL VENTILATION MANUAL PRODUCED BY
THE AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS, SHALL BE
PROVIDED IN AREAS WHERE EXPOSURES ARE ABOVE THE PEL OR TLV SPECIFIED BY
OSHA OR OTHER LOCAL, STATE AND FEDERAL REGULATIONS.

ACID-RESISTANT RUBBER OR PLASTIC APRON, BOOTS AND PROTECTIVE CLOTHING.
SAFETY SHOWER AND EYEWASH.


SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES 


BOILING POINT: ELECTROLYTE APPROX. 235 DEG. F

VAPOR PRESSURE: ELECTROLYTE 1 MMHg @ 145.8 DEG. F

SPECIFIC GRAVITY ELECTROLYTE (H2O = 1): 1.250 - 1.320 PH <2

MELTING POINT: POLYPROPYLENE <320 DEG. F

PERCENT VOLATILE BY VOLUME (%): NOT APPLICABLE

VAPOR DENSITY:
HYDROGEN (AIR = 1): 0.069
ELECTROLYTE (AIR = 1): 3.4 AT STP

EVAPORATION RATE: NOT APPLICABLE

SOLUBILITY IN WATER:
ELECTROLYTE: 100% SOLUBLE

REACTIVITY IN WATER:
ELECTROLYTE: WATER REACTIVE (1)

APPEARANCE AND ODOR:
BATTERY: POLYPROPYLENE OR HARD RUBBER CASE, SOLID.
LEAD: GRAY, METALLIC, SOLID

ELECTROLYTE:
LIQUID, COLORLESS, OILY FLUID; NUISANCE ODOR WHEN HOT OR CHARGING BATTERY.


SECTION 10 - STABILITY AND REACTIVITY 


STABILITY:
UNSTABLE ( )
STABLE   (X)

CONDITIONS TO AVOID:
HIGH TEMPERATURES - CASES DECOMPOSE AT <320 DEG. F.
AVOID OVERCHARGING AND SMOKING, OR SPARKS NEAR BATTERY SURFACE AND RAPID
OVERCHARGE.

INCOMPATIBILITY (MATERIALS TO AVOID):
SPARKS, OPEN FLAMES, KEEP BATTERY CASE AWAY FROM STRONG OXIDIZERS.

HAZARDOUS DECOMPOSITION PRODUCTS:
AN EXPLOSIVE HYDROGEN/OXYGEN MIXTURE WITHIN THE BATTERY MAY OCCUR DURING
CHARGING. COMBUSTION CAN PRODUCE CARBON DIOXIDE (CO2) AND CARBON MONOXIDE
(CO). MOLTEN METALS PRODUCE FUMES AND/OR VAPOR THAT MAY BE TOXIC OR
RESPIRATORY IRRITANTS.

HAZARDOUS POLYMERIZATION:
MAY OCCUR      ( )
WILL NOT OCCUR (X)

DO NOT OVERCHARGE.


SECTION 11 - TOXICOLOGICAL INFORMATION 


GENERAL:
THE PRIMARY ROUTES OF EXPOSURE TO LEAD ARE INGESTION OR INHALATION OF DUST
AND FUMES.

ACUTE:

INGESTION/INHALATION:
EXPOSURE TO LEAD AND ITS COMPOUNDS MAY CAUSE HEADACHE, NAUSEA, VOMITING,
ABDOMINAL SPASMS, FATIGUE, SLEEP DISTURBANCES, WEIGHT LOSS, ANEMIA, AND
PAIN IN THE LEGS, ARMS AND JOINTS. KIDNEY DAMAGE, AS WELL AS ANEMIA, CAN
OCCUR FROM ACUTE EXPOSURE.

CHRONIC:

INHALATION/INGESTION:
PROLONGED EXPOSURE TO LEAD AND ITS COMPOUNDS MAY PRODUCE MANY OF THE
SYMPTOMS OF SHORT-TERM EXPOSURE AND MAY ALSO CAUSE CENTRAL NERVOUS SYSTEM
DAMAGE, GASTROINTESTINAL DISTURBANCES, ANEMIA, AND WRIST DROP. SYMPTOMS
OF CENTRAL NERVOUS SYSTEM DAMAGE INCLUDE FATIGUE, HEADACHES, TREMORS,
HYPERTENSION, HALLUCINATIONS, CONVULSIONS AND DELIRIUM. KIDNEY DYSFUNCTION
AND POSSIBLE INJURY HAS ALSO BEEN ASSOCIATED WITH CHRONIC LEAD POISONING.
CHRONIC OVER-EXPOSURE TO LEAD HAS BEEN IMPLICATED AS A CAUSATIVE AGENT FOR
THE IMPAIRMENT OF MALE AND FEMALE REPRODUCTIVE CAPACITY, BUT THERE IS, AT
PRESENT, NO SUBSTANTIATION OF THE IMPLICATION. PREGNANT WOMEN SHOULD BE
PROTECTED FROM EXCESSIVE EXPOSURE. LEAD CAN CROSS THE PLACENTAL BARRIER
AND UNBORN CHILDREN MAY SUFFER NEUROLOGICAL DAMAGE OR DEVELOPMENTAL
PROBLEMS DUE TO EXCESSIVE LEAD EXPOSURE IN PREGNANT WOMEN.


SECTION 12 - ECOLOGICAL INFORMATION 


IN MOST SURFACE WATER AND GROUNDWATER, LEAD FORMS COMPOUNDS WITH ANIONS
SUCH AS HYDROXIDES, CARBONATES, SULFATES, AND PHOSPHATES AND PRECIPITATES
OUT OF THE WATER COLUMN. LEAD MAY OCCUR AS SORBED IONS OR SURFACE COATINGS
ON SEDIMENT MINERAL PARTICLES OR MAY BE CARRIED IN COLLOIDAL PARTICLES IN
SURFACE WATER. MOST LEAD IS STRONGLY RETAINED IN SOIL, RESULTING IN LITTLE
MOBILITY. LEAD MAY BE IMMOBILIZED BY ION EXCHANGE WITH HYDROUS OXIDES OR
CLAYS OR BY CHELATION WITH HUMIC OR FULVIC ACIDS IN THE SOIL. LEAD (WHEN IN
THE DISSOLVED PHASE) IS BIO-ACCUMULATED BY PLANTS AND ANIMALS, BOTH AQUATIC
AND TERRESTRIAL.


SECTION 13 - DISPOSAL CONSIDERATIONS 


WASTE DISPOSAL METHODS:
LEAD-ACID BATTERIES ARE COMPLETELY RECYCLABLE. RETURN WHOLE SCRAP BATTERIES
TO DISTRIBUTOR, MANUFACTURER OR LEAD SMELTER FOR RECYCLING. FOR INFORMATION
ON RETURNING BATTERIES TO TROJAN BATTERY COMPANY FOR RECYCLING CALL
800-423-6569. FOR NEUTRALIZED SPILLS, PLACE RESIDUE IN ACID-RESISTANT
CONTAINERS WITH SORBENT MATERIAL, SAND OR EARTH AND DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS FOR ACID AND LEAD
COMPOUNDS. CONTACT LOCAL AND/OR STATE ENVIRONMENTAL OFFICIALS REGARDING
DISPOSAL INFORMATION.


SECTION 14 - TRANSPORT INFORMATION 


U.S. DOT PROPER SHIPPING NAME:
UN2794, BATTERIES, WET, FILLED WITH ACID, ELECTRIC STORAGE

U.S. DOT HAZARD CLASS: 8
U.S. DOT ID NUMBER: UN 2794
U.S. DOT PACKING GROUP: III
U.S. DOT LABEL: CORROSIVE

IMO PROPER SHIPPING NAME: UN2794, BATTERIES, WET, FILLED WITH ACID
IMO U.N. CLASS: 8
IMO U.N. NUMBER: UN 2794
IMO PACKING GROUP: III
IMO LABEL: CORROSIVE
IMO VESSEL STOWAGE: A

IATA PROPER SHIPPING NAME: UN2794, BATTERIES, WET, FILLED WITH ACID
IATA U.N. CLASS: 8
IATA U.N. NUMBER: UN 2794
IATA PACKING GROUP: III
IATA LABEL: CORROSIVE


SECTION 15 - REGULATORY INFORMATION 


U.S. HAZARDOUS UNDER HAZARD COMMUNICATION STANDARD:
LEAD: YES
SULFURIC ACID: YES
ANTIMONY: YES
ARSENIC: YES

INGREDIENTS LISTED ON TSCA INVENTORY: YES

CERCLA SECTION 304 HAZARDOUS SUBSTANCES:

LEAD: YES
RQ: NA*

SULFURIC ACID: YES
RQ: 1000 POUNDS

ANTIMONY: YES
RQ: 5000 POUNDS

ARSENIC: YES
RQ: 1 POUND

*REPORTING NOT REQUIRED WHEN DIAMETER OF THE PIECES OF SOLID METAL RELEASED
IS EQUAL TO OR EXCEEDS 100 MICROMETERS.

EPCRA SECTION 302 EXTREMELY HAZARDOUS SUBSTANCE:
SULFURIC ACID: YES

EPCRA SECTION 313 TOXIC RELEASE INVENTORY:

LEAD:
CAS NO: 7439-92-1

SULFURIC ACID:
CAS NO: 7664-93-9

ANTIMONY:
CAS NO: 7440-36-0

ARSENIC:
CAS NO: 7440-38-2


SECTION 16 - OTHER INFORMATION 


THE INFORMATION ABOVE IS BELIEVED TO BE ACCURATE AND REPRESENTS THE BEST
INFORMATION CURRENTLY AVAILABLE TO US. HOWEVER, TROJAN BATTERY COMPANY
MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR
IMPLIED, WITH RESPECT TO SUCH INFORMATION, AND WE ASSUME NO LIABILITY
RESULTING FROM ITS USE. USERS SHOULD MAKE THEIR OWN INVESTIGATIONS TO
DETERMINE THE SUITABILITY OF THE INFORMATION FOR THEIR PARTICULAR PURPOSES.
ALTHOUGH REASONABLE PRECAUTIONS HAVE BEEN TAKEN IN THE PREPARATION OF
THE DATA CONTAINED HEREIN, IT IS OFFERED SOLELY FOR YOUR INFORMATION,
CONSIDERATION AND INVESTIGATION. THIS MATERIAL SAFETY DATA SHEET PROVIDES
GUIDELINES FOR THE SAFE HANDLING AND USE OF THIS PRODUCT; IT DOES NOT AND
CANNOT ADVISE ON ALL POSSIBLE SITUATIONS, THEREFORE, YOUR SPECIFIC USE OF
THIS PRODUCT SHOULD BE EVALUATED TO DETERMINE IF ADDITIONAL PRECAUTIONS ARE
REQUIRED.

FORM MSDS REV.: JANUARY 09, 2013