SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. B BAK SHENZHEN BAK BATTERY CO., LTD. MATERIAL SAFETY DATA SHEET FOR LITHIUM ION CELLS
TRADE NAME: LITHIUM ION CELLS MODEL: ALL 18650 MODELS MANUFACTURED BY SHENZHEN BAK WITH CAPACITY LESS THAN OR EQUAL TO 3 AHR. NOMINAL VOLTAGE: 3.7V MANUFACTURER: SHENZHEN BAK BATTERY CO., LTD. ADDRESS: BAK INDUSTRY PARK KUI CHONG STREET LONG GANG DISTRICT, SHENZHEN CITY, GUANGDONG PROVINCE CHINA TELEPHONE: +86-755-89770161
CHEMICAL NAME MOLECULAR CAS NO. CLASSIFICATION FORMULA LITHIUM TRANSITION METAL OXIDE(2) LixMO2 PROPRIETARY CARBON (GRAPHITE) C 7440-44-0 ALUMINUM Al 7429-90-5 COPPER Cu 7440-50-8 STEEL Fe 7439-89-6 ELECTROLYTE PROPRIETARY FLAMMABLE LIQUID NOTES: 1) NOT EVERY PRODUCT CONTAINS ALL OF THESE MATERIALS 2) M MEANS A COMBINATION OF Co, Ni OR Mn. THIS COMPONENT MAY CONSIST OF A MIXTURE OF COMPOUNDS, EACH OF WHICH MAY CONTAIN THESE ELEMENTS.
LITHIUM ION CELLS ARE NOT HAZARDOUS WHEN USED ACCORDING TO THE INSTRUCTIONS OF THE MANUFACTURER UNDER NORMAL CONDITIONS. IN CASE OF ABUSE, THERE IS A RISK OF RUPTURE, FIRE, HEAT, OR LEAKAGE OF INTERNAL COMPONENTS, WHICH COULD RELEASE HAZARDOUS MATERIALS.
LITHIUM ION CELLS ARE NOT HAZARDOUS UNDER NORMAL CIRCUMSTANCES. IN CASE OF FIRE OR RUPTURE, THE LEAKAGE OF INTERNAL HAZARDOUS SUBSTANCE AND FORMATION OF HAZARDOUS SUBSTANCE MAY OCCUR, AND THE FOLLOWING MEASURES SHOULD BE TAKEN IN CASE OF CONTACT WITH THESE: EYES: CHECK FOR AND REMOVE ANY CONTACT LENSES. IMMEDIATELY FLUSH WITH PLENTY OF CLEAN WATER FOR AT LEST 15 MINUTES, SEEK MEDICAL ASSISTANCE. SKIN: IMMEDIATELY FLUSH WITH PLENTY OF CLEAN WATER FOR 15 MINUTES; SEEK MEDICAL ASSISTANCE IF REACTION IS SEVERE. INHALATION: REMOVE TO FRESH AIR IMMEDIATELY, SEEK MEDICAL ASSISTANCE, AND VENTILATE THE CONTAMINATED AREA. INGESTION: RINSE MOUTH WITH CLEAN WATER IMMEDIATELY. MAKE THE VICTIM VOMIT AND SEEK MEDICAL ASSISTANCE.
EXTINGUISH WITH PLENTY OF WATER, DRY POWDER EXTINGUISHERS, SANDS OR EARTH. COMBUSTION" PRODUCTS AND DECOMPOSITION PRODUCTS INCLUDE: CARBON MONOXIDE, CARBON DIOXIDE, HYDROGEN FLUORIDE, PHOSPHORUS FLUORIDE.
WHEN LEAKAGE OF CELLS HAPPENS, LIQUID COULD BE ABSORBED WITH SANDS, EARTH OR OTHER INERT SUBSTANCE, AND THE CONTAMINATED AREA SHOULD BE VENTILATED.
HANDLING PRECAUTIONS: DO NOT SHORT POSITIVE AND NEGATIVE TERMINALS BY CONTACT WITH CONDUCTORS. DO NOT OVERHEAT OR INCINERATE. DO NOT OPEN, PUNCTURE, CRUSH OR DEFORM CELLS STORAGE: STORE AND USE AWAY FROM HEAT, SPARKS, OPEN FLAME, OR ANY OTHER IGNITION SOURCE. STORE IN A COOL, DRY ENVIRONMENT (LESS THAN 35 DEG. C, LESS THAN 85% RH).
THERE IS NO PROTECTION REQUIRED UNDER NORMAL CONDITIONS. IN CASE OF LEAKAGE VENTILATION IS REQUIRED. RESPIRATOR, EYE PROTECTION, PROTECTIVE GLOVES AND PROTECTIVE CLOTHES ARE REQUIRED WHEN DEALING WITH FIRE AND LEAKAGE.
CELLS ARE NOT SINGLE CHEMICAL MATERIAL; THERE ARE NO SPECIFIC PHYSICAL AND CHEMICAL PROPERTIES SUCH AS MELTING POINT AND BOILING POINT.
CELLS ARE STABLE UNDER NORMAL CONDITIONS. THE FOLLOWING SUBSTANCE MAY APPEAR IN CASE OF FIRE OR LEAKAGE: ORGANIC CARBONATE, HYDROGEN FLUORIDE, CARBON MONOXIDE, CARBON DIOXIDE, PHOSPHORUS FLUORIDE.
CELLS ARE NOT HAZARDOUS WHEN USED PROPERLY. IN CASE OF FIRE OR LEAKAGE COMBUSTION AND DECOMPOSITION PRODUCTS MAY CAUSE IRRITATION AND TOXICITY TO SKIN, EYE AND RESPIRATORY SYSTEMS. TOXICITY DATA OF SOME SUBSTANCE IS LISTED: HYDROGEN FLUORIDE: EXTREMELY TOXIC, MAY BE FATAL IF INHALED OR INGESTED. READILY ABSORBED THROUGH THE SKIN CONTACT MAY BE FATAL. POSSIBLE MUTAGEN. LCLO: 50 PPM/30M (HUMAN BEINGS) LC50: 1276 PPM/1H (RATS). CARBON AND GRAPHITE: SLIGHTLY HAZARDS IN CASE OF SKIN CONTACT (IRRITANT), INGESTION, INHALATION, WHICH WILL CAUSE CHRONIC DAMAGE TO UPPER RESPIRATORY TRACT AND CARDIOVASCULAR SYSTEM. COPPER: DUST MAY. CAUSE RESPIRATORY IRRITATION. LD50: 3.5 MG KG(-1) (MOUSE).
THERE IS NO INFLUENCE ON ECOLOGY OR ENVIRONMENT WHEN USED AND DISPOSED OF PROPERLY.
DISCARDED CELLS SHOULD NOT BE TREATED AS ORDINARY TRASH. RECYCLING IS RECOMMENDED AND IS REQUIRED BY LAW IN MANY JURISDICTIONS. DO NOT INCINERATE. LEAKING OR DAMAGED CELLS SHOULD BE TREATED AS CHEMICAL WASTE; PACKAGING IS NORMALLY NOT CONTAMINATED BY CEILS.
THE FOLLOWING REGULATIONS APPLY TO THE TRANSPORT OF LITHIUM ION CELLS WORLDWIDE: 1) UN RECOMMENDATIONS ON THE TRANSPORT OF DANGEROUS GOODS ACCORDING TO WHICH LITHIUM ION CELLS ARE ASSIGNED UN ID#3480, CLASS 9, PACKING GROUP II 2) INTERNATIONAL AIR TRANSPORT ASSOCIATION (IATA) DANGEROUS GOODS REGULATIONS (DGR) 3) INTERNATIONAL MARITIME ORGANIZATION (IMO) INTERNATIONAL MARITIME DANGEROUS GOODS (IMDG) CODE 4) IATA DGR 54TH EDITION FOR TRANSPORTATION 5) TRANSPORT FASHION: BY AIR, BY SEA LITHIUM ION BATTERIES CONTAINING NO MORE THAN 1.5 G/CELL AND 8 G/BATTERY PACK EQUIVALENT LITHIUM CAN BE SHIPPED AS 'NON-DANGEROUS GOODS' PROVIDING THE CELLS HAVE PASSED THE REQUIRED TESTS ACCORDING TO UN38.3 (UN MANUAL OF TESTS AND CRITERIA, PART III, SUBSECTION 38.3). IN THIS CASE" PACKING INSTRUCTION 965-967 OF IATA-DGR AND SPECIAL PROVISIONS 188 OF IMO-IMDG CODE ALSO APPLY.
FOR SHIPPING REGULATIONS SEE SECTION 14.
THIS DOCUMENT IS PROVIDED FOR TECHNICAL INFORMATION ONLY. THE INFORMATION IS PROVIDED IN GOOD FAITH AND IS BELIEVED TO BE ACCURATE AS OF THE DATE OF PREPARATION. BAK MAKES NO WARRANTY, EITHER EXPRESS OR IMPLIED, WITH RESPECT TO THIS INFORMATION AND DISCLAIMS ALL LEGAL RESPONSIBILITY FROM RELIANCE ON IT. PREPARED/DATE: 2012-12-27 AUDITED/DATE: APPROVED/DATE: FILE NO./REV.: MSDS-163/ |