SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. RAYOVAC(R*) SPECTRUM BRANDS, INC. RAYOVAC DIVISION 3001 DEMING WAY MIDDLETON, WI 53562-1431 PHONE: (608) 275-3340 FAX: (608) 275-4577 HTTP://WWW.RAYOVAC.COM SAFETY DATA SHEET THE SAFETY DATA SHEET IS SUPPLIED AS A SERVICE TO YOU. FOR OTHER RELATED INFORMATION, PLEASE VISIT: HTTP://WWW.RAYOVAC.COM/LEARNING/TECHNICAL- OEM/SAFETY-DATA-SHEETS.ASPX
PRODUCT NAME: ZINC CHLORIDE BATTERY SIZES: ALL SIZES EMERGENCY HOTLINE: 800-424-9300 (24 HR, CHEMTREC)
WE WOULD LIKE TO INFORM OUR CUSTOMERS THAT THESE BATTERIES ARE EXEMPT ARTICLES AND ARE NOT SUBJECT TO THE 29 CFR 1910.1200 OSHA REQUIREMENTS, CANADIAN WHMIS REQUIREMENTS OR GHS REQUIREMENTS. EMERGENCY OVERVIEW: OSHA HAZARDS: NOT APPLICABLE TARGET ORGANS: NOT APPLICABLE GHS CLASSIFICATION: NOT APPLICABLE GHS LABEL ELEMENTS, INCLUDING PRECAUTIONARY STATEMENT: NOT APPLICABLE PICTOGRAM: NOT APPLICABLE SIGNAL WORDS: NOT APPLICABLE HAZARD STATEMENTS: NOT APPLICABLE PRECAUTIONARY STATEMENTS: NOT APPLICABLE
INGREDIENT NAME CAS # % TLV*/**TWA STEEL 7439-89-6 8-14 NOT LISTED MANGANESE DIOXIDE 1313-13-9 28-32 C5.0 MG/M3 (TWA) ZINC 7440-66-6 16-20 5.0 MG/M3 (ZnO AS FUME) ACETYLENE BLACK 1333-86-4 7-13 3.5 MG/M3 (CARBON BLACK, TWA) AMMONIUM CHLORIDE 12125-02-9 1-3 NOT LISTED ZINC CHLORIDE 7646-85-7 6-10 NOT LISTED LEAD 7439-92-1 <0.02 50 UG/M3 (TWA) WATER, PAPER, PLASTIC, BALANCE OTHER *SOURCE: OSHA 29 CFR 1910.1000 TABLE Z-1, 2 OR 3 11-01-2012
THRESHOLD LIMIT VALUE (TLV) AND SOURCE: NA EFFECTS OF OVEREXPOSURE: NONE (SEE SECTION 2 AND 4 FOR FIRE OR RUPTURE SITUATIONS) EMERGENCY FIRST AID PROCEDURES: SKIN AND EYES: IN THE EVENT THAT BATTERY RUPTURES, FLUSH EXPOSED SKIN WITH FLOWING LUKEWARM WATER FOR A MINIMUM OF 15 MINUTES. GET IMMEDIATE MEDICAL ATTENTION FOR EYES. WASH SKIN WITH SOAP AND WATER. SWALLOWING: IF YOU OR YOUR DOCTOR SUSPECTS THAT A BATTERY HAS BEEN INGESTED-FOR ASSISTANCE IN THE US CALL THE NATIONAL BATTERY INGESTION HOTLINE ANY TIME AT (202) 625-3333: IN CANADA CALL: 416-813-5900. FOR MORE INFORMATION, PLEASE VISIT: HTTP://WWW.NEMA.ORG/POLICY/ENVIRONMENTAL-STEWARDSHIP/DOCUMENTS/ BATTERYINGEST.PDF
FLASH POINT: NA LOWER (LEL): NA FLAMMABLE LIMITS IN AIR (%): NA UPPER (UEL): NA EXTINGUISHING MEDIA: USE WATER, FOAM, OR DRY POWDER AS APPROPRIATE. AUTO-IGNITION: NA SPECIAL FIRE FIGHTING PROCEDURES: AS WITH ANY FIRE, WEAR SELF-CONTAINED BREATHING APPARATUS TO AVOID INHALATION OF HAZARDOUS DECOMPOSITION PRODUCTS (SEE SECTION 2). SPECIAL FIRE OR EXPLOSION HAZARDS: LIKE ANY SEALED CONTAINER, BATTERY CELLS MAY RUPTURE WHEN EXPOSED TO EXCESSIVE HEAT; THIS COULD RESULT IN THE RELEASE OF CORROSIVE MATERIALS.
TO CONTAIN AND CLEAN UP LEAKS OR SPILLS: IN THE EVENT OF A BATTERY RUPTURE, PREVENT SKIN CONTACT AND COLLECT ALL RELEASED MATERIAL IN A PLASTIC LINED METAL CONTAINER. REPORTING PROCEDURE: REPORT ALL SPILLS IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REPORTING REQUIREMENTS.
STORE BATTERIES IN A DRY PLACE. STORING UNPACKAGED CELLS TOGETHER COULD RESULT IN CELL SHORTING AND HEAT BUILD-UP. DO NOT RECHARGE. DO NOT PUNCTURE OR ABUSE.
RESPIRATORY PROTECTION (SPECIFY TYPE): NA VENTILATION: LOCAL EXHAUST: NA MECHANICAL (GENERAL): NA SPECIAL: NA OTHER: NA PROTECTIVE GLOVES: NA EYE PROTECTION: NA OTHER PROTECTIVE CLOTHING: NA
BOILING POINT @ 760 MMHg (DEG. C): NA PERCENT VOLATILE BY VOLUME (%): NA VAPOR PRESSURE (MMHg @ 25 DEG. C): NA EVAPORATION RATE (BUTYL ACETATE = 1): NA VAPOR DENSITY (AIR = 1): NA PHYSICAL STATE: NA DENSITY (GRAMS/CC): NA SOLUBILITY IN WATER (% BY WEIGHT): NA PH: NA APPEARANCE AND ODOR: GEOMETRIC SOLID OBJECT
STABLE OR UNSTABLE: STABLE INCOMPATIBILITY (MATERIALS TO AVOID): NA HAZARDOUS DECOMPOSITION PRODUCTS: NA DECOMPOSITION TEMPERATURE (0 DEG. F): NA HAZARDOUS POLYMERIZATION: WILL NOT OCCUR CONDITIONS TO AVOID: AVOID ELECTRICAL SHORTING, PUNCTURING OR DEFORMING
INGREDIENT NAME CAS # % TLV*/**TWA STEEL 7439-89-6 8-14 NOT LISTED MANGANESE DIOXIDE 1313-13-9 28-32 C5.0 MG/M3 (TWA) ZINC 7440-66-6 16-20 5.0 MG/M3 (ZnO AS FUME) ACETYLENE BLACK 1333-86-4 7-13 3.5 MG/M3 (CARBON BLACK, TWA) AMMONIUM CHLORIDE 12125-02-9 1-3 NOT LISTED ZINC CHLORIDE 7646-85-7 6-10 NOT LISTED LEAD 7439-92-1 <0.02 50 UG/M3 (TWA) WATER, PAPER, PLASTIC, BALANCE OTHER *SOURCE: OSHA 29 CFR 1910.1000 TABLE Z-1, 2 OR 3 11-01-2012
UNDER NORMAL USE THESE BATTERIES DO NOT RELEASE THEIR INGREDIENTS INTO THE ENVIRONMENT. DAMAGED OR ABUSED BATTERIES CAN RELEASE SMALL AMOUNTS OF ZINC, AND MANGANESE. DAMAGED BATTERIES CARELESSLY DISCARDED COULD RELEASE SMALL AMOUNTS OF ZINC TO STORM OR SURFACE WATER. DO NOT PLACE IN FIRE. DISPOSE OF PROPERLY WHEN DISCHARGED. USE A RECYCLING OUTLET IF AVAILABLE. THOSE COLLECTING BATTERIES SHOULD FOLLOW STATE AND FEDERAL REGULATIONS. PARTIALLY DISCHARGED DAMAGED BATTERIES CAN OVERHEAT AND CAUSE FIRES IN THE PRESENCE OF OTHER COMBUSTIBLE MATERIALS.
ALWAYS COMPLY WITH FEDERAL, STATE OR LOCAL REQUIREMENTS. IF YOU CHOOSE TO RETAIN DISCHARGED BATTERIES AND RECYCLE BE SURE TO STORE THEM OUT OF THE REACH OF CHILDREN AND PETS. DO NOT STORE WITH ADULT MEDICATIONS OF SIMILAR SIZE OR SHAPE. FOR ADDITIONAL INFORMATION ON DISPOSAL/RECLAIM OPTIONS, VISIT: HTTP://WWW.NEMA.ORG/POLICY/ENVIRONMENTAL- STEWARDSHIP/DOCUMENTS/COMPANIES%20CLAIMING%20TO%20RECYCLE.MARCH2005.PDF
TRANSPORTATION-SHIPPING: THESE ARE CONSIDERED DRY-CELL BATTERIES AND THEY ARE NON-DANGEROUS GOODS FOR TRANSPORTATION. THESE BATTERIES MUST BE PACKED IN A WAY TO PREVENT SHORT CIRCUITS OR GENERATION OF A DANGEROUS QUANTITY OF HEAT. USDOT: SEE SPECIAL PROVISION 130. IMDG/OCEAN: NOT LISTED. ICAO/IATA: SEE SPECIAL PROVISION A123. THIS SPECIAL PROVISION ALSO STATES TO PUT THE WORDS "NOT RESTRICTED" AND "SPECIAL PROVISION A123" ON THE AIR WAYBILL WHEN AN AIR WAYBILL IS ISSUED.
SARA 313: NOTIFICATION IS NOT REQUIRED BECAUSE THESE PRODUCTS ARE ARTICLE(S) THAT DO NOT RELEASE A COVERED TOXIC CHEMICAL UNDER THE NORMAL CONDITIONS OF STORAGE, USE, OR HANDLING. NOTICE: THE INFORMATION AND RECOMMENDATIONS SET FORTH ARE MADE IN GOOD FAITH AND ARE BELIEVED TO BE ACCURATE AT THE DATE OF PREPARATION. SPECTRUM BRANDS INC. (RAYOVAC) MAKES NO WARRANTY EXPRESSED OR IMPLIED. NA = NOT APPLICABLE SAFETY DATA SHEET INFORMATION (800) 237-7000 APPROVED BY: KEVIN J. DOMACK 01-03-2014 |