SDS Table of Contents Click the desired link below to jump directly to that section in the SDS. A ANTI-SEIZE TECHNOLOGY A.S.T. INDUSTRIES, INC. H.M.I.S.: H 1 F 0 R 0 P.P. A POLY-TEMP(R*) JOINT SEALANT 100% PTFE GASKET MATERIAL STOCK # ('S): 28001, 28301, 28003, 28303, 28005, 28305, 28007, 28107, 28307, 28010, 28110, 28310, 28014, 28114, 28314, 28017, 28117, 28317, 28020, 28120, 28320, 28025, 28125, 28325 MATERIAL SAFETY DATA SHEET
MANUFACTURE: ANTI-SEIZE TECHNOLOGY 2345 N. 17TH AVE. FRANKLIN PARK, IL 60131 PHONE: 847-455-2300 EMERGENCY PHONE, 24 HR: INFOTRAC @ 1-800-535-5053 OR 352-323-3500
CAS # OSHA PEL, TLV SARA III PROP 65, PERCENT POLYTETRA- 9002-84-0 NOT ESTABLISHED NO NO 100 FLUROETHANE
ROUTES OF ENTRY: SKIN ( ) EYES ( ) INHALATION (X) INGESTION ( ) HEALTH HAZARDS: "TEFLON" IS RELATIVELY NON-TOXIC. THE PRIMARY HEALTH HAZARD ASSOCIATED WITH "PTFE" IS EXTREMELY HIGH TEMPERATURE THERMAL DECOMPOSITION BY PRODUCTS. DO NOT USE THIS PRODUCT IN APPLICATIONS WHERE THE TEMPERATURE IS EXPECTED TO EXCEED 550F. IF TOBACCO PRODUCTS ARE CONTAMINATED WITH "TEFLON" THEN A CONDITION KNOWN AS "POLYMER FUME FEVER" CAN OCCUR. THE EFFECTS ARE REVERSIBLE.
SKIN: WASH WITH SOAP AND WATER, EYES: UNLIKELY INGESTION: IF INGESTED THIS PRODUCT IS NOT EXPECTED TO CAUSE AN ACUTE REACTION. CALL A POISON CONTROL CENTER OR A PHYSICIAN. INHALATION: NOT LIKELY UNDER NORMAL CONDITIONS OF USE. IF USING IN HIGH TEMPERATURE APPLICATIONS WHERE THERMAL DECOMPOSITION IS LIKELY, USE A LOCAL EXHAUST TO REMOVE FUMES. IF DIZZINESS OR IRRITATION OCCURS, SEEK FRESH AIR. CHEMICAL ('S) LISTED AS CARCINOGENS: NPT?: NO I.A.R.C.?: NO OSHA?: NO
FLASH POINT AND METHOD USED: DOES NOT APPLY. DOES NOT BURN FLAMMABLE LIMITS: LEL: NO DATA UEL: NO DATA EXTINGUISHING MEDIA: FOAM, CO2, DRY CHEMICAL SPECIAL FIRE FIGHTING PROCEDURES: MAY EMIT TOXIC FUMES IN A FIRE. UNUSUAL FIRE AND EXPLOSION HAZARDS: DENSE SMOKE AND NOXIOUS OR TOXIC FUMES MAY BE GENERATED IN A FIRE. FIRE FIGHTERS SHOULD WEAR A SELF CONTAINED BREATHING APPARATUS.
SPILL/LEAKAGE PROCEDURES: DOES NOT APPLY
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: NONE REASONABLY FORESEEN. OTHER PRECAUTIONS: KEEP AWAY FROM CHILDREN.
RESPIRATORY PROTECTION: NORMALLY NOT REQUIRED. IF THIS PRODUCT IS BEING USED IN HIGH TEMPERATURE APPLICATIONS WHERE THE PRODUCT "SMOKES", USE A LOCAL EXHAUST OR VENTILATE THE AREA TO MAINTAIN THE AIR QUALITY. A "N.I.O.S.H" APPROVED ORGANIC VAPOR RESPIRATOR IS ALSO ACCEPTABLE. PROTECTIVE GLOVES: NOT REQUIRED. EYE PROTECTION: NOT REQUIRED. WORK/HYGIENIC PRACTICES: USE GOOD STANDARD PRACTICES WHEN USING THIS MATERIAL. DO NOT SMOKE WHILE USING.
BOILING POINT: DOES NOT APPLY MELTING POINT: OVER 500 F VAPOR PRESSURE: 0 EVAPORATION RATE: 0 SOLUBILITY IN WATER: NONE REACTIVITY IN WATER: NONE SPECIFIC GRAVITY: NO DATA PERCENT VOLATILE: 0 APPEARANCE AND ODOR: WHITE PLASTIC LIKE TAPE
STABILITY: STABLE (X) UNSTABLE ( ) CONDITIONS TO AVOID: TEMPERATURE OVER 500F INCOMPARABILITY, (MATERIALS TO AVOID): ALKALI METALS, INTERHALOGEN COMPOUNDS. HAZARDOUS DECOMPOSITION PRODUCTS: IF THE SERVICE TEMPERATURES EXCEEDS 750 F. THEN "TEFLON" WILL BEGIN TO UNDERGO THERMAL DECOMPOSITION. AT THESE TEMPERATURES "TEFLON" CAN EMIT ACUTELY TOXIC VAPORS. THESE VAPORS CAN INCLUDE HEXAFLUOROPROPYLENE, PERFLUOROISOBUTYLENE AND CARBONYL FLUORIDE. HAZARDOUS POLYMERIZATION: WILL NOT OCCUR.
SEE SECTION 2 FOR ADDITIONAL INFORMATION AND EXPOSURE LIMITS
NO ADDITIONAL INFORMATION IS AVAILABLE. THIS PRODUCT IS NOT EXPECTED TO BIOACCUMULATE.
WASTE DISPOSAL: DISPOSE OF IN A RESPONSIBLE MANNER. FOLLOW LOCAL, STATE AND FEDERAL GUIDELINES. DO NOT DISCHARGE INTO SEWERS OR WATERWAYS. INCINERATION IS THE PREFERRED METHOD OF DISPOSAL, ALTHOUGH IT MAY BE LANDFILLED AT AN APPROVED FACILITY.
TRANSPORTATION BY LAND (49CFR): NOT REGULATED TRANSPORTATION BY AIR (ICAO/IATA): NOT REGULATED TRANSPORTATION BY SHIP (IMO/IMDG): NOT REGULATED WHMIS: NOT REGULATED.
CALIFORNIA PROPOSITION 65: NO RCRA: NO OZONE DEPLETING SUBSTANCES: NONE DOT SHIPPING CLASS: NOT HAZARDOUS SARA TITLE III: NO TASCA INVENTORY: ALL INGREDIENTS LISTED CERCLA: NO N.F.P.A. RATING: H 0 F 2 AND R 0
THE INFORMATION CONTAINED HEREIN IS BASED ON DATA CONSIDERED ACCURATE, HOWEVER, NO WARRANTY IS EXPRESSED OR IMPLIED REGARDING THE ACCURACY OF THE DATA OR THE RESULTS OBTAINED FROM THE USE OF HIS PRODUCT. THEREFORE, BECAUSE THE PRODUCT MAY BE USED UNDER CONDITIONS BEYOND OUR CONTROL, WE ASSUME NO LIABILITY FOR ITS USE. DATE: 04/19/2012 POLY TEMP JOINT, 16 PART ISO MSDS |