Common Name: AST-RTV SILICONE HI-TEMP RED 8 OZ SELF DISPENSING CAN
Manufacturer: ANTI-SEIZE TECHNOLOGY
SDS Revision Date: 1/28/2015
SDS Format: GHS-US
   
Item Number(s): 5E144
Manufacturer Model Number(s):



SDS Table of Contents
Click the desired link below to jump directly to that section in the SDS.
SECTION 1 - PRODUCT AND COMPANY IDENTIFICATION 
SECTION 2 - HAZARD IDENTIFICATION 
SECTION 3 - COMPOSITION / INFORMATION ON INGREDIENTS 
SECTION 4 - FIRST AID MEASURES 
SECTION 5 - FIRE FIGHTING MEASURES 
SECTION 6 - ACCIDENTAL RELEASE MEASURES 
SECTION 7 - HANDLING AND STORAGE 
SECTION 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION 
SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES 
SECTION 10 - STABILITY AND REACTIVITY 
SECTION 11 - TOXICOLOGICAL INFORMATION 
SECTION 12 - ECOLOGICAL INFORMATION 
SECTION 13 - DISPOSAL CONSIDERATION 
SECTION 14 - TRANSPORT INFORMATION 
SECTION 15 - REGULATORY INFORMATION 
SECTION 16 - OTHER INFORMATION 



A
ANTI-SEIZE TECHNOLOGY
A.S.T. INDUSTRIES, INC.

AST-RTV(TM) SILICONE HI-TEMP RED 8 OZ SELF DISPENSING CAN

SAFETY DATA SHEET


SECTION 1 - PRODUCT AND COMPANY IDENTIFICATION 


PRODUCT TYPE: SILICONE ELASTOMERIC, RTV

SUPPLIER:
ANTI-SEIZE TECHNOLOGY
2345 N. 17TH AVE.
FRANKLIN PARK, IL 60131

PHONE: 847-455-2300

FAX: 847-455-2371

WEB: ANTISEIZE.COM

EMERGENCY PHONE, 24 HR:
INFOTRAC @ 1-800-535-5053 (US & CANADA)
1-352-323-3500 (INTERNATIONAL)

DATE: JAN 28, 2015


SECTION 2 - HAZARD IDENTIFICATION 


GHS CLASSIFICATION (HAZCOM 2012):

LABEL ELEMENTS: EXCLAMATION MARK

SIGNAL WORD: WARNING

HAZARD PHRASES:
CONTENT UNDER PRESSURE
CAUSES SKIN IRRITATION CATEGORY 2
CAUSES SERIOUS EYE IRRITATION. CATEGORY 2A
CAUSES SKIN SENSITIZATION CATEGORY 1

PRECAUTIONARY PHRASES:
WASH THOROUGHLY AFTER HANDLING.
WEAR PROTECTIVE GLOVES, EYE AND FACE PROTECTION.
USE IN A WELL-VENTILATED AREA.
TAKE OFF CONTAMINATED CLOTHING AND WASH IT BEFORE REUSE.
KEEP AWAY FROM HEAT, SPARKS, OPEN FLAMES OR HOT SURFACES.
PRESSURIZED CONTAINER: DO NOT PIERCE OR BURN, EVEN AFTER USE.

RESPONSE:

SKIN:
WASH WITH SOAP AND WATER, USING A NAIL BRUSH. PAY PARTICULAR ATTENTION TO
FINGER NAILS AND OPEN WOUNDS.

EYES:
FLUSH EYE WITH WATER FOR 15 MINUTES, LIFTING THE EYELIDS. IF IRRITATION
PERSISTS CONSULT A PHYSICIAN.

INGESTION:
NOT A LIKELY ROUTE OF EXPOSURE, DO NOT INDUCE VOMITING. USE A GASTRIC
LAVAGE, AND CALL A POISON CONTROL CENTER OR A PHYSICIAN.

INHALATION:
AVOID OVEREXPOSURE. DIZZINESS OR RESPIRATORY IRRITATION ARE SIGNS OF
OVEREXPOSURE. SEEK FRESH AIR. OR FOLLOW OTHER STANDARD MEDICAL PRACTICES.

STORAGE:
WHEN NOT IN USE KEEP CONTAINER CLOSED
KEEP AWAY FROM CHILDREN

OTHER HAZARDS:
DURING THE CURING PROCESS ACETIC ACID VAPORS WILL BE GENERATED WHICH CAN
IRRITATE THE RESPIRATORY TRACT. USE WITH ADEQUATE VENTILATION.


SECTION 3 - COMPOSITION / INFORMATION ON INGREDIENTS 


INGREDIENT               CAS #        %

METHYLTRIACETOXYSILANE    4253-34-3    1 - 5

ETHYLTRIACETOXYSILANE    17689-77-9    1 - 5

SILICON DIOXIDE           7631-86-9   10 - 30

NON-HAZARDOUS POLYMER    70131-67-8   60 - 80

ACETIC ACID                 64-19-7    1 - 5

RED IRON OXIDE            1309-37-1    1 - 5

ACETIC ACID FUMES ARE FORMED DURING THE CURING PROCESS. THESE FUMES MAY BE
IRRITATING TO THE RESPIRATORY TRACT.

THE SPECIFIC IDENTITY AND/OR EXACT PERCENTAGE OF COMPOSITION HAS BEEN
WITHHELD AS A TRADE SECRET


SECTION 4 - FIRST AID MEASURES 


EYE:
RINSE OPENED EYE FOR SEVERAL MINUTES UNDER RUNNING WATER. IF SYMPTOMS
PERSIST, GET MEDICAL ATTENTION.

SKIN: REMOVE CONTAMINATED CLOTHING. WASH EXPOSED AREA WITH SOAP AND WATER.

INHALATION: SUPPLY FRESH AIR; CONSULT DOCTOR IN CASE OF COMPLAINTS.

INGESTION: RINSE MOUTH WITH WATER. DO NOT INDUCE VOMITING.

MOST IMPORTANT SYMPTOMS AND EFFECTS, BOTH ACUTE AND DELAYED:
RESPIRATORY TRACT IRRITATION, EYE IRRITATION.


SECTION 5 - FIRE FIGHTING MEASURES 


EXTINGUISHING MEDIA:
USE WATER SPRAY OR FOG, FOAM, CARBON DIOXIDE OR DRY CHEMICAL. DRY CHEMICAL
IS PREFERRED.

SPECIAL HAZARDS ARISING FROM THE PRODUCT: NONE ANTICIPATED.

SPECIAL EQUIPMENT AND PRECAUTIONS FOR FIRE-FIGHTERS:
WEAR NIOSH APPROVED POSITIVE PRESSURE, SELF-CONTAINED BREATHING APPARATUS
AND FULL PROTECTIVE CLOTHING. COOL FIRE EXPOSED CONTAINERS WITH WATER
SPRAY.


SECTION 6 - ACCIDENTAL RELEASE MEASURES 


PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES:

USE APPROPRIATE PERSONAL PROTECTION EQUIPMENT. IF FUMES ARE PRESENT, WEAR A
NIOSH APPROVED RESPIRATOR. WEAR PROTECTIVE GLOVES.

WIPE UP OR SCRAPE UP AND CONTAIN FOR DISPOSAL. DISPOSE OF SATURATED
ABSORBENT OR CLEANING MATERIALS APPROPRIATELY, SINCE SPONTANEOUS HEATING
MAY OCCUR.

ENVIRONMENTAL HAZARDS:
SPILLED MATERIAL, EVEN IN SMALL QUANTITIES, MAY PRESENT A SLIP HAZARD.
SCRAPE US AS MUCH MATERIAL AS POSSIBLE. SPILLED MATERIALS WILL SOLIDIFY
OVER TIME. DISPOSE OF IN ACCORDANCE WITH APPROPRIATE LOCAL, STATE AND
FEDERAL GUIDELINES.

METHODS AND MATERIALS FOR CONTAINMENT AND CLEAN UP.:
USE ABSORBENT MATERIALS, SCRAPE UP EXCESS MATERIAL FOR PROPER DISPOSAL.


SECTION 7 - HANDLING AND STORAGE 


PRECAUTIONS FOR SAFE HANDLING:
USE WITH ADEQUATE VENTILATION. AVOID EYE CONTACT. AVOID SKIN CONTACT. DO
NOT TAKE INTERNALLY. DO NOT HANDLE CONTACT LENSES UNTIL ALL MATERIALS ARE
REMOVED FROM HANDS.

CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES.
USE REASONABLE CARE AND STORE SWAY FROM OXIDIZING MATERIALS. STORE AWAY
FROM HEAT, SPARKS OR OPEN FLAMES. STORE AT TEMPERATURES BELOW 90 DEG. F.
KEEP CONTAINER CLOSED WHEN NOT IN USE.


SECTION 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION 


HAZARDOUS COMPONENT      ACGIH TLV         OSHA PEL          OTHER

METHYLTRIACETOXYSILANE   NOT ESTABLISHED   NOT ESTABLISHED

ETHYLTRIACETOXYSILANE    NOT ESTABLISHED   NOT ESTABLISHED

SILICON DIOXIDE          6 MG/M3 TWA       20 MPPCF TWA,
                                           0.8 MG/M3 TWA

ACETIC ACID              15 PPM STEL       10 PPM
                         10 PPM TWA        25 MG/M3 PEL

ENGINEERING CONTROLS:
USE WITH ADEQUATE VENTILATION, ESPECIALLY IN CONFINED SPACES. USE LOCAL
VENTILATION IF AIR MOVEMENT IS NOT ADEQUATE TO MAINTAIN AIR QUALITY BELOW
ESTABLISHED EXPOSURE LIMITS.

INDIVIDUAL PROTECTION MEASURES:

RESPIRATORY PROTECTION:
NORMALLY NOT REQUIRED UNLESS LARGE QUANTITIES OF THIS PRODUCT ARE BEING
USED OR IF WORKING IN CONFINED SPACES. ACETIC ACID VAPORS (VINEGAR LIKE
ODOR) CAN IRRITATE EYES, SKIN OR RESPIRATORY TRACT. IF NEED USE A NIOSH
APPROVED ORGANIC VAPOR RESPIRATOR.

EYE/FACE PROTECTION:
SAFETY GLASSES WITH SIDE SPLASH SHIELDS ARE RECOMMENDED.

SKIN PROTECTION:
IF PROLONGED OR REPEATED EXPOSURE IS EXPECTED, WEAR CHEMICAL RESISTANT
GLOVES SUCH AS VINYL OR NEOPRENE.


SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES 


APPEARANCE: CLEAR, VISCOUS SEALANT

ODOR: MILD VINEGAR LIKE ODOR

ODOR THRESHOLD: NOT ESTABLISHED

PH: NO DATA

MELTING POINT/FREEZING POINT: NOT AVAILABLE

BOILING POINT: NO DATA

FLASH POINT: NOT FLAMMABLE

EVAPORATION RATE: NOT AVAILABLE

FLAMMABLE LIMITS:
LEL: NOT ESTABLISHED
UEL: NOT ESTABLISHED

VAPOR PRESSURE: NOT ESTABLISHED

VOC CONTENT: <3%

VAPOR DENSITY (AIR = 1): NOT AVAILABLE

SPECIFIC GRAVITY: 1.04

WATER SOLUBILITY: NOT SOLUBLE

OCTANOL/WATER PARTITION COEFFICIENT: NOT AVAILABLE

AUTOIGNITION TEMPERATURE: NOT AVAILABLE

DECOMPOSITION TEMPERATURE: NOT AVAILABLE

VISCOSITY: NOT AVAILABLE

EXPLOSION PROPERTIES: NONE

OXIDIZING PROPERTIES: NOT OXIDIZING

AEROSOL FIRE PROTECTION LEVEL: NOT APPLICABLE

FLAMMABILITY (SOLID, GAS): NOT AVAILABLE


SECTION 10 - STABILITY AND REACTIVITY 


REACTIVITY: NO DATA

CHEMICAL STABILITY: STABLE UNDER NORMAL STORAGE AND HANDLING CONDITIONS.

CONDITIONS TO AVOID: APPLICATION TO HOT SURFACES.

INCOMPATIBLE MATERIALS: STRONG OXIDIZING AGENTS AND ACIDS

HAZARDOUS DECOMPOSITION PRODUCTS:
ACETIC ACID FUMES ARE SLOWLY GENERATED IN THE CURING PROCESS. SILICA MIST,
ACRID SMOKE AND FUMES IN EXTREME TEMPERATURES OR FIRE.


SECTION 11 - TOXICOLOGICAL INFORMATION 


POTENTIAL HEALTH EFFECTS:

EYE:
MAY CAUSE SERIOUS EYE IRRITATION IF LARGE QUANTITIES ARE BEING USED. THE
ACETIC ACID VAPORS LIBERATED DURING THE CURING PROCESS CAN IRRITATED EYES.

SKIN:
MAY CAUSE SKIN IRRITATION IF THIS MATERIAL IS ALLOWED TO REMAIN ON SKIN FOR
PROLONGED PERIODS.

INHALATION:
ACETIC ACID (VINEGAR LIKE ODOR) MAY IRRITATE NOSE, THROAT, RESPIRATORY
TRACT. WHEN HEATED TO TEMPERATURES EXCEEDING 300 DEG. F (150 DEG. C) IN THE
PRESENCE OF AIR, CURED SILICONES MAY FORM FORMALDEHYDE VAPORS. FORMALDEHYDE
IS A POTENTIAL CARCINOGEN AND IS A KNOWN SKIN AND RESPIRATORY TRACT
IRRITANT.

INGESTION: NOT EXPECTED TO BE HARMFUL BY INGESTION.

CARCINOGEN STATUS: NO

ACUTE TOXICITY VALUES:

SILICON DIOXIDE, AS DUST OR FUME, ORAL, RAT, LD50 >22,000 MG/KG

ACETIC ACID, ORAL, RAT, LD50 3.50 G/KG, DERMAL, RABBIT, LD50, 1,060 MG/KG,
INHALATION, RAT, LC50 (4 HR) 11.4MG/L


SECTION 12 - ECOLOGICAL INFORMATION 


NOT AVAILABLE


SECTION 13 - DISPOSAL CONSIDERATION 


WASTE DISPOSAL:
DISPOSE OF IN A RESPONSIBLE MANNER. FOLLOW LOCAL, STATE AND FEDERAL
GUIDELINES. DO NOT DISCHARGE INTO SEWERS OR WATERWAYS. INCINERATION IS THE
PREFERRED METHOD OF DISPOSAL, ALTHOUGH IT MAY BE LAND FILLED AT AN APPROVED
FACILITY.


SECTION 14 - TRANSPORT INFORMATION 


DOT:
PROPER SHIPPING NAME: AEROSOLS
DOT HAZARD CLASS: 2.2
UN NUMBER: UN 1950
PACKING GROUP: NONE

IMDG:
SHIPPING DESCRIPTION: AEROSOLS
HAZARD CLASS: 2.2
IDENTIFICATION NUMBER: UN 1950
PACKING GROUP: NONE

ICAO/IATA:
SHIPPING DESCRIPTION: AEROSOLS, NON-FLAMMABLE
ID NUMBER: UN 1950
HAZARD CLASS: 2.2
PACKING GROUP: NONE


SECTION 15 - REGULATORY INFORMATION 


SAFETY, HEALTH, AND ENVIRONMENTAL REGULATIONS SPECIFIC FOR THE PRODUCT IN
QUESTION.

CERCLA HAZARDOUS SUBSTANCES (SECTION 103)/RQ:
THIS PRODUCT IS NOT SUBJECT TO REPORTING REQUIREMENTS UNDER CERCLA.
HOWEVER, MANY STATES HAVE MORE STRINGENT RELEASE REPORTING REQUIREMENTS.
REPORT SPILLS REQUIRED UNDER FEDERAL, STATE AND LOCAL REGULATIONS.

SARA HAZARD CATEGORY (311/312): NOT HAZARDOUS

SARA 313:
THIS PRODUCT CONTAINS THE FOLLOWING CHEMICALS REGULATED UNDER SARA TITLE
III, SECTION 313: NONE

EPA TSCA INVENTORY:
ALL OF THE COMPONENTS OF THIS PRODUCT ARE LISTED ON THE TSCA INVENTORY.

CALIFORNIA PROPOSITION 65:
THIS PRODUCT IS NOT KNOWN TO CONTAIN LISTED CHEMICALS.


SECTION 16 - OTHER INFORMATION 


THE INFORMATION CONTAINED HEREIN IS BASED ON DATA CONSIDERED ACCURATE,
HOWEVER, NO WARRANTY IS EXPRESSED OR IMPLIED REGARDING THE ACCURACY OF
THE DATA OR THE RESULTS OBTAINED FROM THE USE OF HIS PRODUCT. THEREFORE,
BECAUSE THE PRODUCT MAY BE USED UNDER CONDITIONS BEYOND OUR CONTROL, WE
ASSUME NO LIABILITY FOR ITS USE.